852 resultados para Whole-Body Counting
Resumo:
The comparability of information collected through telephone interviews and information collected through mailed questionnaires has not been well studied. As part of the first phase of a randomized controlled trial of population screening for melanoma in Queensland, Australia, the authors compared histories of skin examination reported in telephone interviews and self-administered mailed questionnaires. A total of 1,270 subjects each completed a telephone interview and a mailed questionnaire 1 month apart in 1999; 564 subjects received the interview first, and 706 received the mailed questionnaire first. Agreement between the two methods was 91.2% and 88.6% for whole-body skin examination by a physician in the last 12 months and the last 3 years, respectively, and 81.9% for whole-body skin self-examination in the last 12 months. Agreement was lower for any skin self-examination. Agreement between the two methods was similar regardless of whether the interview or the questionnaire was administered first. Missing data were less frequent for interviews (0.5%) than for mailed questionnaires (3.8%). Costs were estimated at A$9.55 (US$6.21) per completed interview and A$3.01 (US$1.96) per questionnaire. The similarity of results obtained using telephone interviews and mailed questionnaires, coupled with the substantially higher cost of telephone interviews, suggests that self-administered mailed questionnaires are an appropriate method of assessing this health behavior.
Resumo:
Screening by whole-body clinical skin examination may improve early diagnosis of melanoma and reduce mortality, but objective scientific evidence of this is lacking. As part of a randomized controlled trial of population screening for melanoma in Queensland, Australia, the authors assessed the validity of self-reported history of whole-body skin examination and factors associated with accuracy of recall among 2,704 participants in 2001. Approximately half of the participants were known to have undergone whole-body skin examination within the past 3 years at skin screening clinics conducted as part of the randomized trial. All positive and negative self-reports were compared with screening clinic records. Where possible, reports of skin examinations conducted outside the clinics were compared with private medical records. The validity of self-reports of whole-body skin examination in the past 3 years was high: Concordance between self-reports and medical records was 93.7%, sensitivity was 92.0%, and specificity was 96.3%. Concordance was lower (74.3%) for self-reports of examinations conducted in the past 12 months, and there was evidence of telescoping in recall for this more recent time frame. In multivariate analysis, women and younger participants more accurately recalled their history of skin examinations. Participants with a history of melanoma did not differ from other participants in their accuracy of recall.
Resumo:
Most magnetic resonance imaging (MRI) spatial encoding techniques employ low-frequency pulsed magnetic field gradients that undesirably induce multiexponentially decaying eddy currents in nearby conducting structures of the MRI system. The eddy currents degrade the switching performance of the gradient system, distort the MRI image, and introduce thermal loads in the cryostat vessel and superconducting MRI components. Heating of superconducting magnets due to induced eddy currents is particularly problematic as it offsets the superconducting operating point, which can cause a system quench. A numerical characterization of transient eddy current effects is vital for their compensation/control and further advancement of the MRI technology as a whole. However, transient eddy current calculations are particularly computationally intensive. In large-scale problems, such as gradient switching in MRI, conventional finite-element method (FEM)-based routines impose very large computational loads during generation/solving of the system equations. Therefore, other computational alternatives need to be explored. This paper outlines a three-dimensional finite-difference time-domain (FDTD) method in cylindrical coordinates for the modeling of low-frequency transient eddy currents in MRI, as an extension to the recently proposed time-harmonic scheme. The weakly coupled Maxwell's equations are adapted to the low-frequency regime by downscaling the speed of light constant, which permits the use of larger FDTD time steps while maintaining the validity of the Courant-Friedrich-Levy stability condition. The principal hypothesis of this work is that the modified FDTD routine can be employed to analyze pulsed-gradient-induced, transient eddy currents in superconducting MRI system models. The hypothesis is supported through a verification of the numerical scheme on a canonical problem and by analyzing undesired temporal eddy current effects such as the B-0-shift caused by actively shielded symmetric/asymmetric transverse x-gradient head and unshielded z-gradient whole-body coils operating in proximity to a superconducting MRI magnet.
Resumo:
Background : Within a randomized trial of population screening for melanoma, primary care physicians conducted whole-body skin examinations and referred all patients with suspect lesions to their own doctor for further treatment. Objective: Our aim was to describe characteristics of skin screening participants, clinical screening diagnoses, management following referral, and specificity and yield of screening examinations. Methods: Information collected from consent forms, referral forms, and histopathological reports of lesions that had been excised or undergone biopsy was analyzed by means of descriptive statistics. Results: A total of 16,383 whole-body skin examinations resulted in 2302 referrals (14.1% overall; 15.5% men, 18.2% >= 50 years of age) for 4129 suspect lesions (including 222 suspected melanoma, 1101 suspected basal cell carcinomas [BCCs], 265 suspected squamous cell carcinomas [SCCs]). Histopathologic results were available for 94.8% of 1417 lesions excised and confirmed 33 melanomas (23 in men; 24 in participants ? 50 years of age), 259 BCCs, and 97 SCCs. The probability of detecting skin cancer of any type within the program was 2.4%. The estimated specificity of whole-body skin examinations for melanoma was 86.1% (95% confidence interval = 85.6-86.6). The positive predictive value (number of confirmed/number of lesions excised or biopsied x 100) for melanoma was 2.5%, 19.3% for BCC, and 7.2% for SCC (overall positive predictive value for skin cancer, 28.9%). Limitations: Follow-up of participants with a negative screening examination has not been conducted for the present investigation. Conclusions: The rate of skin cancer detected per 100 patients screened was higher than previously reported and men and attendees older than 50 years more frequently received a referral and diagnosis of melanoma. The specificity for detection of melanoma through whole-body skin examination by a primary care physician was comparable to that of other screening tests, including mammography.
Resumo:
Survival from cutaneous melanoma is mainly dependent on the thickness of the lesion at diagnosis. Skin screening may increase detection of thin lesions and hence improve survival. Within a community-based randomized controlled trial of a population screening program for melanoma in Queensland, Australia, 9 communities were randomly assigned to the 3-year intervention and 9 communities to the control group. Skin screening prevalence was monitored by cross-sectional surveys at baseline, 1, 2 and 3 years into the intervention and 2 years later. At baseline, prevalence of whole-body clinical skin examination was similar in intervention and control communities. In intervention communities, the prevalence of whole-body skin examinations increased to 29.2%, an absolute difference of 18% from baseline, with a peak of 34.8% 2 years after baseline, and began to decline again at the end of the intervention period. The largest increases were seen in men and women ≥50 years. Uptake of screening did not differ according to melanoma risk factors; however, the decline in screening was less in participants who reported a number of melanoma risk factors. The prevalence of skin self-examination remained stable during the intervention program. No changes were observed in the control communities. These results indicate that the intervention program significantly increased the prevalence of whole-body clinical skin examinations in intervention communities. Once the intervention program ceased, and particularly after skin clinics ceased, levels of skin screening began to decline. The provision of specialized skin screening clinics may be needed to achieve sufficient screening rates should population based screening for skin cancer be considered. © 2005 Wiley-Liss, Inc.
Resumo:
Reasons for performing study: Obtaining magnetic resonance images of the inner hoof wall tissue at the microscopic level would enable early accurate diagnosis of laminitis and therefore more effective therapy. Objectives: To optimise magnetic resonance imaging (MRI) parameters in order to obtain the highest possible resolution of the structures beneath the equine hoof wall. Methods: Magnetic resonance microscopy (MRM) was performed in front feet from 6 cadaver horses using T-2-weighted fast spin echo (FSE-T-2), and T-1-weighted gradient echo (GRE-T-1) sequences. Results: In T-2 weighted FSE images most of the stratum medium showed no signal, however the coronary, terminal and sole papillae were visible. The stratum lamellatum was clearly visible and primary epidermal lamellae could be differentiated from dermal lamellae. Conclusion: Most structures beneath the hoof wall were differentiated. Conventional scanners for diagnostic MRI in horses are low or high field. However this study used ultra-high field scanners currently not available for clinical use. Signal-to-noise ratio (SIN) increases as a function of field strength. An increase of spatial resolution of the image results in a decreased SIN. SIN can also be improved with better coils and the resolution of high field MRI scanners will increase as technology develops and surface array coils become more readily available. Potential relevance: Although MR images with microscopic resolution were obtained ex vivo, this study demonstrates the potential for detection of lamellar pathology as it occurs. Early recognition of the development of laminitis to instigate effective therapy at an earlier stage and may improve the outcome for laminitic horses. Clinical MR is now readily available at 3 T, while 4 T, 7 T and 9 T systems are being used for human whole body applications.
Resumo:
Purpose: To examine the effect of progressive resistance training on muscle function, functional performance, balance, body composition, and muscle thickness in men receiving androgen deprivation for prostate cancer. Methods: Ten men aged 59-82 yr on androgen deprivation for localized prostate cancer undertook progressive resistance training for 20 wk at 6- to 12-repetition maximum (RM) for 12 upper- and lower-body exercises in a university exercise rehabilitation clinic. Outcome measures included muscle strength and muscle endurance for the upper and lower body, functional performance (repeated chair rise, usual and fast 6-m walk, 6-m backwards walk, stair climb, and 400-m walk time), and balance by sensory organization test. Body composition was measured by dual-energy x-ray absorptiometry and muscle thickness at four anatomical sites by B-mode ultrasound. Blood samples were assessed for prostate specific antigen (PSA), testosterone, growth hormone (GH), cortisol, and hemoglobin. Results: Muscle strength (chest press, 40.5%; seated row, 41.9%; leg press, 96.3%; P < 0.001) and muscle endurance (chest press, 114.9%; leg press, 167.1%; P < 0.001) increased significantly after training. Significant improvement (P < 0.05) occurred in the 6-m usual walk (14.1%), 6-m backwards walk (22.3%), chair rise (26.8%), stair climbing (10.4%), 400-m walk (7.4%), and balance (7.8%). Muscle thickness increased (P < 0.05) by 15.7% at the quadriceps site. Whole-body lean mass was preserved with no change in fat mass. There were no significant changes in PSA, testosterone, GH, cortisol, or hemoglobin. Conclusions: Progressive resistance exercise has beneficial effects on muscle strength, functional performance and balance in older men receiving androgen deprivation for prostate cancer and should be considered to preserve body composition and reduce treatment side effects.
Resumo:
Patellofemoral pain (PFP) may be related to unfavorable knee joint loading. Delayed and/or reduced activity of vastus medialis obliquus (VMO) and different movement patterns have been identified in individuals with PFP in some studies, whereas other studies have failed to show a difference compared to non-affected controls. The discrepancy between study results may depend on the different tasks that have been investigated. No previous study has investigated these variables in postural responses to unpredictable perturbations in PFP. Whole body three dimensional kinematics and surface EMG of quadriceps muscles activation was studied in postural responses to unpredictable support surface translations in 17 women with PFP who were pain free at the time of testing, and 17 matched healthy controls. The results of the present study showed earlier onset of VMO activity and associated changes in kinematics to anterior platform translation in the PFP subjects. We suggest that the relative timing between the portions quadriceps muscles may be task specific and part of an adapted response in attempt to reduce knee joint loading. This learned response appears to remain even when the pain is no longer present.
Resumo:
It is well known that resistance training improves muscle strength in older adults and may enhance or preserve functional performance. However, it is unclear if the volume of work undertaken in the elderly alters the response in functional performance. PURPOSE: To investigate the effect of a high- versus low-volume resistance training program on functional performance in older adults. METHODS: Thirty-two healthy men and women aged 65-78 years were randomly assigned to either a single-set (SS, n = 16) or 3-set (MS, n = 16) progressive resistance training program for 20 weeks. Groups trained 2 days per week using machine weights at 8 repetitions maximum (8-RM) for 7 upper and lower body exercises. Muscle strength was assessed by the 1-RM and functional performance by a battery of tests (repeated chair rise, usual and fast 6-m walk, 6-m backwards walk, floor rise to standing, stair climb, and 400-m walk time). RESULTS: Twenty-eight subjects completed the study. There was no difference between groups at baseline in muscle strength or functional performance. Whole body muscle strength significantly increased in both groups with greater gains in the 3-set group (MS 32.9 ± 3.1%; SS 18.6 ± 2.7%, mean ± SE; P < 0.01). Significant improvement (time effect, P < 0.01) occurred for both groups in the chair rise (MS 13.6 ± 3.2%; SS 10.2 ± 3.0%), 6-m backwards walk (MS 14.9 ± 3.3%; SS 14.3 ± 4.2%), stair climb (MS 6.4 ± 2.8%; SS 7.7 ± 3.1%) and 400-m walk (MS 7.4 ± 1.4%; SS 3.9 ± 1.2%). There were no interaction (group × time) effects for functional performance and no differences by sex. CONCLUSION: Resistance training that utilizes either a singleset or 3-set regimen may significantly and similarly improve functional performance in community-dwelling older adults. Enhancement of functional performance may prolong independence and improve quality of life. ©2004The American College of Sports Medicine
Resumo:
We have recently introduced the concept of whole-body asymmetric MRI systems [1]. In this theoretical study, we investigate the PNS characteristics of whole-body asymmetric gradient systems as compared to conventional symmetric systems. Recent experimental evidence [2] supports the hypothesis of transverse gradients being the largest contributor of PNS due to induced electric currents. Asymmetric head gradient coils have demonstrated benefits in the past [3]. The numerical results are based on an anatomically-accurate 2mm-human voxel-phantom NORMAN [4]. The results of this study can facilitate the optimization of whole-body asymmetric gradients in terms of patient comfort/safety (less PNS), while prospering the use of asymmetric MRI systems for in-vivo medical interventions.
Resumo:
A new passive shim design method is presented which is based on a magnetization mapping approach. Well defined regions with similar magnetization values define the optimal number of passive shims, their shape and position. The new design method is applied in a shimming process without prior-axial shim localization; this reduces the possibility of introducing new errors. The new shim design methodology reduces the number of iterations and the quantity of material required to shim a magnet. Only a few iterations (1-5) are required to shim a whole body horizontal bore magnet with a manufacturing error tolerance larger than 0.1 mm and smaller than 0.5 mm. One numerical example is presented
Resumo:
Antisense technology is a novel drug discovery method, which provides an essential tool for directly using gene sequence information to rationally design specific inhibitions of mRNA, to treat a wide range of diseases. The efficacy of naked oligodeoxynucleotides (ODNs) is relatively short lived due to rapid degradation in vivo. The entrapment of ODNs within biodegradable sustained-release delivery systems may improve ODN stability and reduce dose required for efficacy. Biodegradable polymer microspheres were evaluated as delivery devices for ODNs and ribozymes. Poly(lactide-co-glycolide) polymers were used due to their biocompatibility and non toxic degradation products. Microspheres were prepared using a double emulsion-deposition method and the formulations characterised. In vitro release profiles were characterised by an initial burst effect during the first 48 hours of release followed by a more sustained release. The release profiles were influenced by microsphere size, copolymer molecular weight, copolymer ratio, ODN loading, ODN length, and ODN chemistry. The serum stability of ODNs was significantly improved when entrapped within polymer microspheres. The cellular association of ODNs entrapped within small spheres (1-2μm) was improved by approximately 20-fold in A431 carcinoma cells compared with free ODNs. Fluorescence microscopy studies showed a more diffuse subcellular distribution when delivered as a microsphere formulation compared with free ODNs, which exhibited the characteristic punctate periplasmic distribution. For in vivo evaluation, polymer microspheres containing fluorescently-labelled ODNs were stereo-taxically administered to the neostriatum of the rat brain. Free ODN resulted in a punctate cellular distribution after 24 hours. In comparison ODN delivered using polymer microspheres were intensely visible in cells 48 hours post administration, and fluorescence appeared to be diffuse covering both cytosolic and nuclear regions. Whole-body autoradiography was also used to evaluate the biodistribution of free tritium labelled ODN and ODN entrapped microspheres, following subcutaneous administration to Balb-C mice. Polymer entrapped ODN gave a similar biodistribution to free ODN. Free ODN was distributed within 24 hours, whereas polymer released ODN was observed still presented in organs and at the site of administration seven days post administration.
Resumo:
Treatment of ex-breeder male NMRI mice with lipid mobilising factor isolated from the urine of cachectic cancer patients, caused a significant increase in glucose oxidation to CO2, compared with control mice receiving phosphate buffered saline. Glucose utilisation by various tissues was determined by the 2-deoxyglucose tracer technique and shown to be elevated in brain, heart, brown adipose tissue and gastrocnemius muscle. The tissue glucose metabolic rate was increased almost three-fold in brain, accounting for the ability of lipid mobilising factor to decrease blood glucose levels. Lipid mobilising factor also increased overall lipid oxidation, as determined by the production of 14CO2 from [14C carboxy] triolein, being 67% greater than phosphate buffered saline controls over a 24 h period. There was a significant increase in [14C] lipid accumulation in plasma, liver and white and brown adipose tissue after administration of lipid mobilising factor. These results suggest that changes in carbohydrate metabolism and loss of adipose tissue, together with an increased whole body fatty acid oxidation in cachectic cancer patients, may arise from tumour production of lipid mobilising factor. © 2002 Cancer Research UK.
Resumo:
The aim of this study is to highlight the relationship between muscle motion, generated by whole body vibration, and the correspondent electromyographic (EMG) activity and to suggest a new method to customize the stimulation frequency. Simultaneous recordings of EMG and tri-axial accelerations of quadriceps rectus femoris from fifteen subjects undergoing vibration treatments were collected. Vibrations were delivered via a sinusoidal oscillating platform at different frequencies (10-45 Hz). Muscle motion was estimated by processing the accelerometer data. Large EMG motion artifacts were removed using sharp notch filters centred at the vibration frequency and its superior harmonics. EMG-RMS values were computed and analyzed before and after artifact suppression to assess muscular activity. Muscles acceleration amplitude increased with frequency. Muscle displacements revealed a mechanical resonant-like behaviour of the muscle. Resonance frequencies and dumping factors depended on subject. Moreover, RMS of artifact-free EMG was found well correlated (R 2 = 0.82) to the actual muscle displacement, while the maximum of the EMG response was found related to the mechanical resonance frequency of muscle. Results showed that maximum muscular activity was found in correspondence to the mechanical resonance of the muscle itself. Assuming the hypothesis that muscle activation is proportional to muscle displacement, treatment optimization (i.e. to choose the best stimulation frequency) could be obtained by simply monitoring local acceleration (resonance), leading to a more effective muscle stimulation. Motion artifact produced an overestimation of muscle activity, therefore its removal was essential. © 2009 IPEM.