988 resultados para Static volumetric method


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nucleic Acid Testing (NAT) as a tool for primary screening of blood donors became a reality in the end of the 1990 decade. We report here the development of an "in-house" RT-PCR method that allows the simultaneous (multiplex) detection of HCV and HIV-RNA in addition to an artificial RNA employed as an external control. This method detects all HIV group M subtypes, plus group N and O, with a detection threshold of 500 IU/mL. After validation, the method replaced p24 Ag testing, in use for blood donation screening since 1996 at our services. From July 2001 to February 2006, 102,469 donations were tested and 41 (0.04%) were found HIV-RNA reactive. One NAT-only reactive donation (antibody non-reactive) was observed, with subsequent seroconversion of the implied donor, giving a yield of 1:102,469. This rate is in contrast to the international experience that reports a detection of approximately 1:600,000 - 1:3,100,000 of isolated HIV-RNA donations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An "in-house" RT-PCR method was developed that allows the simultaneous detection of the RNA of the Hepatitis C Virus (HCV) and an artificial RNA employed as an external control. Samples were analyzed in pools of 6-12 donations, each donation included in two pools, one horizontal and one vertical, permitting the immediate identification of a reactive donation, obviating the need for pool dismembering. The whole process took 6-8 hours per day and results were issued in parallel to serology. The method was shown to detect all six HCV genotypes and a sensitivity of 500 IU/mL was achieved (95% hit rate). Until July 2005, 139,678 donations were tested and 315 (0.23%) were found reactive for HCV-RNA. Except for five false-positives, all 310 presented the corresponding antibody as well, so the yield of NAT-only donations was zero, presenting a specificity of 99.83%. Detection of a window period donation, in the population studied, will probably demand testing of a larger number of donations. International experience is showing a rate of 1:200,000 - 1:500,000 of isolated HCV-RNA reactive donations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study a citrate-buffered version of QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method for determination of 14 organochlorine pesticides (OCPs) residues in tamarind peel, fruit and commercial pulp was optimized using gas chromatography (GC) coupled with electron-capture detector (ECD) and confirmation by GC tandem mass spectrometry (GC–MS/MS). Five procedures were tested based on the original QuEChERS method. The best one was achieved with increased time in ultrasonic bath. For the extract clean-up, primary secondary amine (PSA), octadecyl-bonded silica (C18) and magnesium sulphate (MgSO4) were used as sorbents for tamarind fruit and commercial pulp and for peel was also added graphitized carbon black (GCB). The samples mass was optimized according to the best recoveries (1.0 g for peel and fruit; 0.5 g for pulp). The method results showed the matrix-matched calibration curve linearity was r2 > 0.99 for all target analytes in all samples. The overall average recoveries (spiked at 20, 40 and 60 μg kg−1) have been considered satisfactory presenting values between 70 and 115% with RSD of 2–15 % (n = 3) for all analytes, with the exception of HCB (in peel sample). The ranges of limits of detection (LOD) and quantification (LOQ) for OCPs were for peel (LOD: 8.0–21 μg kg−1; LOQ: 27–98 μg kg−1); for fruit (LOD: 4–10 μg kg−1; LOQ: 15–49 μg kg−1) and for commercial pulp (LOD: 2–5 μg kg−1; LOQ: 7–27 μg kg−1). The method was successfully applied in tamarind samples being considered a rapid, sensitive and reliable procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thirty Candida albicans isolated from oral candidosis patients and 30 C. albicans isolated from control individuals were studied. In vitro susceptibility tests were performed for amphotericin B, fluconazole, 5-flucytosine and itraconazole through the Clinical and Laboratorial Standards Institute (CLSI) reference method and E test system. The results obtained were analyzed and compared. MIC values were similar for the strains isolated from oral candidosis patients and control individuals. The agreement rate for the two methods was 66.67% for amphotericin B, 53.33% for fluconazole, 65% for flucytosine and 45% for itraconazole. According to our data, E test method could be an alternative to trial routine susceptibility testing due to its simplicity. However, it can not be considered a substitute for the CLSI reference method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To evaluate the feasibility and acceptability of an exergame intervention as a tool to promote physical activity in outpatients with schizophrenia. Design Feasibility/Acceptability Study and Quasi-Experimental Trial. Method Sixteen outpatients with schizophrenia received treatment as usual and they all completed an 8-week exergame intervention using Microsoft Kinect® (20 min sessions, biweekly). Participants completed pre and post treatment assessments regarding functional mobility (Timed Up and Go Test), functional fitness performance (Senior Fitness Test), motor neurological soft signs (Brief Motor Scale), hand grip strength (digital dynamometer), static balance (force plate), speed of processing (Trail Making Test), schizophrenia-related symptoms (Positive and Negative Syndrome Scale) and functioning (Personal and Social Performance Scale). The EG group completed an acceptability questionnaire after the intervention. Results Attrition rate was 18.75% and 69.23% of the participants completed the intervention within the proposed schedule. Baseline clinical traits were not related to game performance indicators. Over 90% of the participants rated the intervention as satisfactory and interactive. Most participants (76.9%) agreed that this intervention promotes healthier lifestyles and is an acceptable alternative to perform physical activity. Repeated-measures MANOVA analyses found no significant multivariate effects for combined outcomes. Conclusion This study established the feasibility and acceptability of an exergame intervention for outpatients with schizophrenia. The intervention proved to be an appealing alternative to physical activity. Future trials should include larger sample sizes, explore patients' adherence to home-based exergames and consider greater intervention dosage (length, session duration, and/or frequency) in order to achieve potential effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

According to the new KDIGO (Kidney Disease Improving Global Outcomes) guidelines, the term of renal osteodystrophy, should be used exclusively in reference to the invasive diagnosis of bone abnormalities. Due to the low sensitivity and specificity of biochemical serum markers of bone remodelling,the performance of bone biopsies is highly stimulated in dialysis patients and after kidney transplantation. The tartrate-resistant acid phosphatase (TRACP) is an iso-enzyme of the group of acid phosphatases, which is highly expressed by activated osteoclasts and macrophages. TRACP in osteoclasts is in intracytoplasmic vesicles that transport the products of bone matrix degradation. Being present in activated osteoclasts, the identification of this enzyme by histochemistry in undecalcified bone biopsies is an excellent method to quantify the resorption of bone. Since it is an enzymatic histochemical method for a thermolabile enzyme, the temperature at which it is performed is particularly relevant. This study aimed to determine the optimal temperature for identification of TRACP in activated osteoclasts in undecalcified bone biopsies embedded in methylmethacrylate. We selected 10 cases of undecalcified bone biopsies from hemodialysis patients with the diagnosis of secondary hyperparathyroidism. Sections of 5 μm were stained to identify TRACP at different incubation temperatures (37º, 45º, 60º, 70º and 80ºC) for 30 minutes. Activated osteoclasts stained red and trabecular bone (mineralized bone) was contrasted with toluidine blue. This approach also increased the visibility of the trabecular bone resorption areas (Howship lacunae). Unlike what is suggested in the literature and in several international protocols, we found that the best results were obtained with temperatures between 60ºC and 70ºC. For technical reasons and according to the results of the present study, we recommended that, for an incubation time of 30 minutes, the reaction should be carried out at 60ºC. As active osteoclasts are usually scarce in a bone section, the standardization of the histochemistry method is of great relevance, to optimize the identification of these cells and increase the accuracy of the histomosphometric results. Our results, allowing an increase in osteoclasts contrast, also support the use of semi-automatic histomorphometric measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The antifungal activities of fluconazole, itraconazole, ketoconazole, terbinafine and griseofulvin were tested by broth microdilution technique, against 60 dermatophytes isolated from nail or skin specimens from Goiania city patients, Brazil. In this study, the microtiter plates were incubated at 28 ºC allowing a reading of the minimal inhibitory concentration (MIC) after four days of incubation for Trichophyton mentagrophytes and five days for T. rubrum and Microsporum canis. Most of the dermatophytes had uniform patterns of susceptibility to the antifungal agents tested. Low MIC values as 0.03 µg/mL were found for 33.3%, 31.6% and 15% of isolates for itraconazole, ketoconazole and terbinafine, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Internet of Things (IoT) has emerged as a paradigm over the last few years as a result of the tight integration of the computing and the physical world. The requirement of remote sensing makes low-power wireless sensor networks one of the key enabling technologies of IoT. These networks encompass several challenges, especially in communication and networking, due to their inherent constraints of low-power features, deployment in harsh and lossy environments, and limited computing and storage resources. The IPv6 Routing Protocol for Low Power and Lossy Networks (RPL) [1] was proposed by the IETF ROLL (Routing Over Low-power Lossy links) working group and is currently adopted as an IETF standard in the RFC 6550 since March 2012. Although RPL greatly satisfied the requirements of low-power and lossy sensor networks, several issues remain open for improvement and specification, in particular with respect to Quality of Service (QoS) guarantees and support for mobility. In this paper, we focus mainly on the RPL routing protocol. We propose some enhancements to the standard specification in order to provide QoS guarantees for static as well as mobile LLNs. For this purpose, we propose OF-FL (Objective Function based on Fuzzy Logic), a new objective function that overcomes the limitations of the standardized objective functions that were designed for RPL by considering important link and node metrics, namely end-to-end delay, number of hops, ETX (Expected transmission count) and LQL (Link Quality Level). In addition, we present the design of Co-RPL, an extension to RPL based on the corona mechanism that supports mobility in order to overcome the problem of slow reactivity to frequent topology changes and thus providing a better quality of service mainly in dynamic networks application. Performance evaluation results show that both OF-FL and Co-RPL allow a great improvement when compared to the standard specification, mainly in terms of packet loss ratio and average network latency. 2015 Elsevier B.V. Al

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new iterative algorithm based on the inexact-restoration (IR) approach combined with the filter strategy to solve nonlinear constrained optimization problems is presented. The high level algorithm is suggested by Gonzaga et al. (SIAM J. Optim. 14:646–669, 2003) but not yet implement—the internal algorithms are not proposed. The filter, a new concept introduced by Fletcher and Leyffer (Math. Program. Ser. A 91:239–269, 2002), replaces the merit function avoiding the penalty parameter estimation and the difficulties related to the nondifferentiability. In the IR approach two independent phases are performed in each iteration, the feasibility and the optimality phases. The line search filter is combined with the first one phase to generate a “more feasible” point, and then it is used in the optimality phase to reach an “optimal” point. Numerical experiences with a collection of AMPL problems and a performance comparison with IPOPT are provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este documento apresenta uma avaliação sobre o uso dos simuladores fisiológicos como padrão para avaliação metrológica dos esfigmomanómetros automáticos na estimação da pressão sanguínea pelo método não invasivo (PNI). O presente estudo procurou avaliar o enquadramento destes equipamentos com os procedimentos das normas e recomendações usadas para apreciação metrológica dos esfigmomanómetros digitais. No contexto da prática metrológica existente determinou-se a existência de uma oportunidade de melhoria nos processos relacionados. O trabalho procurou obter resposta a diversas questões, relacionando a medição da pressão pelo método não invasivo, com o uso dos simuladores fisiológicos, o contexto em que estes podem ser usados, as formas de simulação, as medições e os resultados, procurando a perspetiva metrológica como enquadramento. As recomendações existentes [1] [2] [3] [4] [5] [6] [7] [8], são muito claras nos procedimentos, validação e nos desvios permitidos para os monitores da tensão arterial (MTA), equipamento que permite a avaliação dos parâmetros fisiológicos do paciente, no entanto, quando se pretende avançar para outro domínio, como o do uso dos simuladores, em particular para a simulação da PNI, não existem recomendações ou normas tão claras, e não existe sobretudo um padrão de referência que imite a natureza dinâmica que caracteriza a pressão sanguínea. O trabalho procurou ainda estabelecer a ligação entre o método clássico de auscultação (o principio de determinação da PS), a técnica digital de medição e os simuladores, para uma melhor compreensão do que é a pressão sanguínea, e como relacionar a problemática da simulação e a de um padrão de referência. Neste trabalho estão ainda presentes abordagens a diversos tópicos, como as validações clínicas, acessórios, ou a metrologia e que influenciam no final os equipamentos e o contexto que se pretende avaliar. Os diversos equipamentos testados procuraram conter amostras diversificadas, quer para os MTA de uso profissional ou doméstico, assim como para os simuladores. A avaliação dos simuladores foi realizada contra um grupo de MTAs. Foi testada a influência na medição, causada pela mudança de acessórios, ou seja, nos resultados, merecendo consideração pela perspetiva metrológica. No resumo dos testes e do estudo sobre este tema, verificou-se que esta tipologia de equipamentos pode contribuir como complemento do processo de calibração típico (estático). Não constitui por si só um método alternativo, mas permitiu estimar possíveis limites de erro e desvio padrão a partir da observação dos resultados práticos, limites esses inferiores aos processos de validação clínica. Atendendo às particularidades, estimou-se como desvio aceitável um erro mais desvio padrão de 5 + 3 mmHg para o processo de simulação. Contudo considera-se ainda importante os testes adicionais em que o simulador permite, ao verificar as medidas de segurança implementadas no equipamento e a condição dos acessórios, que como verificado afetam os resultados. No entanto nem todos os simuladores se mostram adequados a este processo pelo que a qualidade da seleção do equipamento para este fim pode eventualmente reduzir ainda mais os possíveis limites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho pretende abordar aspectos relacionados com o controlo de compactação em aterros, com base na avaliação de parâmetros “in situ”, tais como: pesos volúmicos, teores em água, graus de compactação e módulos de deformabilidade. Recorrendo aos métodos correntes no controlo de compactação, como o ensaio de carga em placa, gamadensímetro, garrafa e ao ensaio de deflectómetro de impacto portátil. Visa-se comparar os resultados obtidos, nas diferentes condições, de modo a possibilitar alcançar correlações entre os ensaios, bem como determinar aqueles que apresentam maior grau de confiança técnico e vantagens operacionais e económicas. De modo a garantir os índices de qualidade da obra é necessário fazer cumprir os critérios exigidos pelo caderno de encargos, nomeadamente nos parâmetros de avaliação do controlo de compactação, para que estas satisfaçam o seu estado funcional e estrutural. Neste tipo de obras os cadernos de encargos de referência em Portugal são os das Estradas de Portigal (EP) e da Brisa, Auto-estradas de Portugal (Brisa), os quais se baseiam em recomendações de classificações de solos. No contexto experimental, foram efectuados dois estudos com condições e materiais diferentes, em obras pertencentes à empresa Mota-Engil Engenharia e Construções, S.A. Nas campanhas de ensaios foram realizados ensaios “in situ” na obra da Subconcessão do Douro Interior – Lote 6 – IC5 – Troço Murça/ Nó de Pombal nas camadas de sub-base e base num agregado de granulometria extensa, e na obra de modernização do troço ferroviário Bombel e Vidigal a Évora, em solos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Informática

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Lógica Computacional

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The method used by YAGYU et al. for the subtype-specific polymerase chain reaction (PCR) amplification of the gp41 transmembrane region of the human immunodeficiency virus type-1 (HIV-1) env gene, was tested. HIV-1 proviral DNA from 100 infected individuals in Itajaí, South Brazil was used to analyze this method. Seventy individuals were determined according to this method as having PCR products at the expected size for subtypes B, C, D and F. Of these individuals, 26 (37.1%) were observed as having the expected amplification for subtype C, and 42 (60%) were observed as having the expected products for subtypes B and D. Of the subtype B and D amplicons, 16 (22.9%) were classified as subtype D, and 26 (37.1%) were classified as subtype B. Two individuals (2.9%) had amplicons that were observed after subtype F-specific amplification was performed. Sequencing and comparing the patient sequences to reference sequences confirmed the classification of sequences of subtypes C and B. However, sequences that were falsely determined as being D and F in the PCR assay were determined as being subtypes C and B, respectively, by sequence analysis. For those individuals from whom no amplified products were obtained, a low viral load that was indicated in their patient history may explain the difficulty in subtyping by PCR methods. This issue was demonstrated by the results of ANOVA when testing the effect of viral load on the success of PCR amplification. The alignment of the obtained sequences with HIV-1 reference sequences demonstrated that there is high intra-subtype diversity. This indicates that the subtype-specific primer binding sites were not conserved or representative of the subtypes that are observed in the Brazilian populations, and that they did not allow the correct classification of HIV-1 subtypes. Therefore, the proposed method by YAGYU et al. is not applicable for the classification of Brazilian HIV-1 subtypes.