930 resultados para Modellazione 3D,Blender,Leap Motion,Leap Aided Modelling,NURBS,Computer Grafica
Resumo:
Notified cases of dengue infections in Singapore reached historical highs in 2004 (9459 cases) and 2005 (13 817 cases) and the reason for such all increase is still to be established. We apply a mathematical model for dengue infection that takes into account the seasonal variation in incidence, characteristic of dengue fever, and which mimics the 2004-2005 epidemics in Singapore. We simulated a set of possible control strategies and confirmed the intuitive belief that killing adult mosquitoes is the most effective strategy to control an ongoing epidemic. On the other hand, the control of immature forms was very efficient ill preventing the resurgence of dengue epidemics. Since the control of immature forms allows the reduction of adulticide, it seems that the best strategy is to combine both adulticide and larvicide control measures during an outbreak, followed by the maintenance of larvicide methods after the epidemic has subsided. In addition, the model showed that the mixed strategy of adulticide and larvicide methods introduced by the government seems to be very effective in reducing the number of cases in the first weeks after the start of control.
Resumo:
Objective: The Purpose of this study was to determine whether handedness influences bilateral shoulder range of motion in nonathlete adult women. Methods: This was an observational Study. Shoulder range of motion (flexion, abduction, horizontal adduction, extension, external and internal rotation) was passively and bilaterally measured in 50 female, right-handed, and healthy university students, ranging from 20 to 29 years of age, who were not practicing repetitive activities with the upper limbs at the time Of this study. The assessment was performed with a universal goniometer, twice for each subject by the same examiner. irst and second measurements were correlated using the intraclass correlation coefficient, which was high for all movements and ranged from 0.80 to 0.97. The Student t test and Wilcoxon test were used to compare the range of motion between the dominant and nondominant shoulders and the mean differences between the 2 sides. The effect of size vias alpha = .05. Results: There is statistically significance difference between the 2 sides when the rotational range of motion is compared the dominant shoulder presented increased external rotation (mean, 4.74 degrees; 95% confidence interval, 1.61-7.87) and decreased internal rotation (mean, 3.52 degrees; 95% confidence interval, 1.64-5.4) compared to the opposite Shoulder. Conclusion: Dominance should be considered when shoulder rotation is evaluated even in nonathlete adult women. (J Manipulative Physiol Ther 2009;32:149-153)
Resumo:
In this work, we take advantage of association rule mining to support two types of medical systems: the Content-based Image Retrieval (CBIR) systems and the Computer-Aided Diagnosis (CAD) systems. For content-based retrieval, association rules are employed to reduce the dimensionality of the feature vectors that represent the images and to improve the precision of the similarity queries. We refer to the association rule-based method to improve CBIR systems proposed here as Feature selection through Association Rules (FAR). To improve CAD systems, we propose the Image Diagnosis Enhancement through Association rules (IDEA) method. Association rules are employed to suggest a second opinion to the radiologist or a preliminary diagnosis of a new image. A second opinion automatically obtained can either accelerate the process of diagnosing or to strengthen a hypothesis, increasing the probability of a prescribed treatment be successful. Two new algorithms are proposed to support the IDEA method: to pre-process low-level features and to propose a preliminary diagnosis based on association rules. We performed several experiments to validate the proposed methods. The results indicate that association rules can be successfully applied to improve CBIR and CAD systems, empowering the arsenal of techniques to support medical image analysis in medical systems. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Purpose: To describe the use of 3.0-T magnetic resonance imaging (MRI) for the evaluation of chronic liver diseases. Materials and Methods: Two groups of patients who had chronic liver diseases and underwent 3.0-T MRI for evaluation of the liver were included in the study. The first group of patients included 66 consecutive patients (33 male, 33 female; mean age +/- standard deviation, 56 +/- 11). The second group of patients included 30 consecutive patients (18 males, 12 females; mean age +/- standard deviation, 53 +/- 10) in whom Variable-Rate Selective Excitation (VERSE) pulses and improved adjustments procedure were used during the acquisitions. Imaging findings of chronic liver diseases, predetermined artifacts and image quality of all individual sequences in the first group and predetermined artifacts and image quality of T2-weighted sequences in the second group were reviewed retrospectively and independently by two reviewers. chi-Square tests were used to compare the findings between two groups of patients and individual sequences. Kappa statistics were used to determine the extent of agreement between the reviewers. Results: Fifteen dysplastic nodules in 6 of 66 (9%) patients and 12 hepatocellular carcinomas in 11 of 66 (17%) patients were detected. Excluding motion artifacts, three-dimensional (313) T1-weighted gradient-echo (GE) sequence was the least affected sequence by the artifacts. Image quality of T1-weighted 3D-GE sequences was excellent in 43 of 66 (65%) patients. In-phase and out-of-phase T1-weighted spoiled GE (SGE) images were fair in 62 of 66 (94%) and 61 of 66 (92%) patients, respectively. The image quality of short tau inversion recovery (STIR) and half-Fourier rapid acquisition with relaxation enhancement (RARE) sequences were fair in 31 of 66 (47%) and 53 of 66 (80%) patients. STIR and half-Fourier RARE sequences in the second group demonstrated significantly better image quality (P=.03 and P<.0001). Conclusion: 3.0-T MRI allows the acquisition of very high quality postgadolinium 3D-GE sequence, which permitted the detection and characterization of lesions in the setting of chronic liver diseases. The use of VERSE pulses and improved adjustments procedure improved the image quality of T2-weighted sequences. In-phase/out-of-phase SGE sequences are at present of fair quality. (C) 2008 Elsevier Inc. All rights reserved.