953 resultados para pupil filter
Resumo:
The mis-evaluation of risk in securitized financial products is central to understanding the global financial crisis. This paper characterizes the evolution of risk factors affecting collateralized debt obligations (CDOs) based on subprime mortgages. A key feature of subprime mortgage-backed indices is that they are distinct in their vintage of issuance. Using a latent factor framework that incorporates this vintage effect, we show the increasing importance of common factors on more senior tranches during the crisis. An innovation of the paper is that we use the unbalanced panel structure of the data to identify the vintage, credit, common and idiosyncratic effects from a state-space specification.
Resumo:
OBJETIVES: To detect anti-Giardia lamblia serum antibodies in healthy children attending public day care centers and to assess serological tests as tools for estimating the prevalence of G. lamblia in endemic areas. METHODS: Three separate stool specimens and filter paper blood samples were collected from 147 children ranging from 0 to 6 years old. Each stool sample was processed using spontaneous sedimentation and zinc sulfate flotation methods. Blood samples were tested by indirect immunofluorescence (IIF) and enzyme-linked immunosorbent assay (ELISA) for Giardia IgG. RESULTS AND CONCLUSIONS: Of 147 individuals tested, 93 (63.3%) showed Giardia cysts in their feces. Using IIF and ELISA, serum antibodies were detected in 93 (63.3%) and 100 (68%) samples , respectively. Sensitivity of IIF and ELISA was 82% and 72%, respectively. However, ELISA revealed to be less specific (39%) than IIF (70%). IIF also showed a higher concordance with microscopic examination than ELISA.
Resumo:
This paper addresses the voltage droop compensation associated with long pulses generated by solid-stated based high-voltage Marx topologies. In particular a novel design scheme for voltage droop compensation in solid-state based bipolar Marx generators, using low-cost circuitry design and control, is described. The compensation consists of adding one auxiliary PWM stage to the existing Marx stages, without changing the modularity and topology of the circuit, which controls the output voltage and a LC filter that smoothes the voltage droop in both the positive and negative output pulses. Simulation results are presented for 5 stages Marx circuit using 1 kV per stage, with 1 kHz repetition rate and 10% duty cycle.
Resumo:
Characteristics of tunable wavelength filters based on a-SiC:H multi-layered stacked cells are studied both theoretically and experimentally. Results show that the light-activated photonic device combines the demultiplexing operation with the simultaneous photodetection and self amplification of an optical signal. The sensor is a bias wavelength current-controlled device that make use of changes in the wavelength of the background to control the power delivered to the load, acting a photonic active filter. Its gain depends on the background wavelength that controls the electrical field profile across the device.
Resumo:
Characteristics of tunable wavelength pi'n/pin filters based on a-SiC:H multilayered stacked cells are studied both experimental and theoretically. Results show that the device combines the demultiplexing operation with the simultaneous photodetection and self amplification of the signal. An algorithm to decode the multiplex signal is established. A capacitive active band-pass filter model is presented and supported by an electrical simulation of the state variable filter circuit. Experimental and simulated results show that the device acts as a state variable filter. It combines the properties of active high-pass and low-pass filter sections into a capacitive active band-pass filter using a changing photo capacitance to control the power delivered to the load.
Resumo:
Objectivo: O objectivo deste estudo foi avaliar a eficácia de um plano de rotatividade de postos de trabalho, específico, na prevalência de sintomatologia músculo-esquelética auto-referida, de operadoras de costura. Metodologia: Realizou-se um estudo quantitativo, observacional e analítico longitudinal, onde se avaliou o efeito de uma intervenção, em 25 operadoras que se voluntariaram para o estudo, de acordo com o interesse da empresa. Foram utilizados como instrumentos de avaliação o Risk Filter, o Questionário Nórdico Músculo-Esquelético e o Rapid Upper Limbs Assessment (RULA). O projecto englobou uma análise de factores de risco e classificação dos respectivos postos de trabalho de modo a estruturar uma (re)organização do trabalho (Plano de rotatividade de postos de trabalho). Resultados: A implementação do projecto reduziu significativamente (p<0,05) a sintomatologia músculo-esquelética auto-referida, sobretudo ao nível da cervical, tornozelos e pés, punhos e mãos, tendo sido estas últimas as áreas de maior prevalência referida. Verificou-se também uma diminuição da média da intensidade de dor reportada, pelas operadoras. Conclusões: O resultado deste estudo reforça a recomendação e implementação da variação do gesto (variação biomecânica da exposição), através da implementação de um plano de rotatividade de postos de trabalho, específico, tornando-se eficaz como intervenção preventiva e promotora de saúde, no que refere às lesões musculesqueléticas relacionadas com o trabalho.
Resumo:
A água é um recurso escasso e indispensável à vida, podendo ser um importante veículo de microrganismos patogénicos com origem fecal. A matéria fecal é também uma fonte de microrganismos resistentes a antimicrobianos e contribui para a sua disseminação e dos seus genes de resistência no ambiente e entre as comunidades microbianas comensais e microrganismos patogénicos humanos e animais. A qualidade microbiológica da água é monitorizada recorrendo à utilização de bioindicadores como Escherichia coli, enterococos e microrganismos totais. O presente estudo apresentou como principal objetivo determinar a prevalência de ESBLs e AmpCs e ainda avaliar a prevalência de estirpes de enterococos com resistência à vancomicina (VRE) em águas do rio Douro e da orla costeira da cidade do Porto. As amostragens de água foram realizadas em quatro locais localizados no estuário do rio Douro e orla costeira da cidade do Porto entre o mês de Abril e Julho. A deteção e quantificação dos bioindicadores foram realizadas pelo método de filtração por membrana. A suscetibilidade das estirpes de E. coli e enterococos foi testada pelo método de difusão em disco relativamente a várias classes de antimicrobianos. As contagens microbianas mais elevadas foram determinadas entre Abril e Junho e em amostras de água doce. Foram isoladas 62 estirpes de E. coli e 49 estirpes de enterococos que apresentaram prevalências de resistência a antimicrobianos de 90,3% (56/62) e 83,7% (41/49), respetivamente. As estirpes de E. coli apresentaram altas frequências de resistência à ampicilina (74,2%) e tetraciclina (61,3%). Nestas estirpes verificou-se ainda fenótipos associados a multirresistência a um mínimo de três classes de antimicrobianos em 56,5% (35/62) dos isolados. Verificou-se que as estirpes de enterococos apresentaram altos níveis de resistência à rifampicina (34,7%) e azitromicina (40,8%), detetando-se ainda a manifestação de fenótipo de resistência à vancomicina em 26,5% das estirpes. Observou-se uma prevalência de 36,7% (18/49) de estirpes de enterococos associadas a fenómenos de multirresistência antimicrobiana. Ana Martins vi Os resultados obtidos sugerem que o rio Douro e orla costeira, bem como os ambientes aquáticos, constituem reservatórios de bactérias e genes de resistência a antimicrobianos e possuem um papel preponderante na sua disseminação.
Resumo:
Fluorescence confocal microscopy (FCM) is now one of the most important tools in biomedicine research. In fact, it makes it possible to accurately study the dynamic processes occurring inside the cell and its nucleus by following the motion of fluorescent molecules over time. Due to the small amount of acquired radiation and the huge optical and electronics amplification, the FCM images are usually corrupted by a severe type of Poisson noise. This noise may be even more damaging when very low intensity incident radiation is used to avoid phototoxicity. In this paper, a Bayesian algorithm is proposed to remove the Poisson intensity dependent noise corrupting the FCM image sequences. The observations are organized in a 3-D tensor where each plane is one of the images acquired along the time of a cell nucleus using the fluorescence loss in photobleaching (FLIP) technique. The method removes simultaneously the noise by considering different spatial and temporal correlations. This is accomplished by using an anisotropic 3-D filter that may be separately tuned in space and in time dimensions. Tests using synthetic and real data are described and presented to illustrate the application of the algorithm. A comparison with several state-of-the-art algorithms is also presented.
Resumo:
This paper presents a direct power control (DPC) for three-phase matrix converters operating as unified power flow controllers (UPFCs). Matrix converters (MCs) allow the direct ac/ac power conversion without dc energy storage links; therefore, the MC-based UPFC (MC-UPFC) has reduced volume and cost, reduced capacitor power losses, together with higher reliability. Theoretical principles of direct power control (DPC) based on sliding mode control techniques are established for an MC-UPFC dynamic model including the input filter. As a result, line active and reactive power, together with ac supply reactive power, can be directly controlled by selecting an appropriate matrix converter switching state guaranteeing good steady-state and dynamic responses. Experimental results of DPC controllers for MC-UPFC show decoupled active and reactive power control, zero steady-state tracking error, and fast response times. Compared to an MC-UPFC using active and reactive power linear controllers based on a modified Venturini high-frequency PWM modulator, the experimental results of the advanced DPC-MC guarantee faster responses without overshoot and no steady-state error, presenting no cross-coupling in dynamic and steady-state responses.
Resumo:
The characteristics of tunable wavelength filters based on a-SiC:H multilayered stacked pin cells are studied both theoretically and experimentally. The optical transducers were produced by PECVD and tested for a proper fine tuning of the cyan and yellow fluorescent proteins emission. The active device consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructures sandwiched between two transparent contacts. Experimental data on spectral response analysis, current-voltage characteristics and color and transmission rate discrimination are reported. Cyan and yellow fluorescent input channels were transmitted together, each one with a specific transmission rate and different intensities. The multiplexed optical signal was analyzed by reading out, under positive and negative applied voltages, the generated photocurrents. Results show that the optimized optical transducer has the capability of combining the transient fluorescent signals onto a single output signal without losing any specificity (color and intensity). It acts as a voltage controlled optical filter: when the applied voltages are chosen appropriately the transducer can select separately the cyan and yellow channel emissions (wavelength and frequency) and also to quantify their relative intensities. A theoretical analysis supported by a numerical simulation is presented.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Imagem Digital com Radiação X.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Proteção contra Radiações.
Resumo:
A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). Methods: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. Results: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. Conclusion: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.
Resumo:
The objectives of this study were to (1) conduct an elemental characterization of airborne particles sampled in Cape Verde and (2) assess the influence of Sahara desert on local suspended particles. Particulate matter (PM10) was collected in Praia city (14°94'N; 23°49'W) with a low-volume sampler in order to characterize its chemical composition by k0-INAA. The filter samples were first weighed and subsequently irradiated at the Portuguese Research Reactor. Results showed that PM10 concentrations in Cape Verde markedly exceeded the health-based air quality standards defined by the European Union (EU), World Health Organization (WHO), and U.S. Environmental Protection Agency (EPA), in part due to the influence of Sahara dust transport. The PM10 composition was characterized essentially by high concentrations of elements originating from the soil (K, Sm, Co, Fe, Sc, Rb, Cr, Ce, and Ba) and sea (Na), and low concentrations of anthropogenic elements (As, Zn, and Sb). In addition, the high concentrations of PM measured in Cape Verde suggest that health of the population may be less affected compared with other sites where PM10 concentrations are lower but more enriched with toxic elements.
Resumo:
Artigo em texto integral no link da versão do editor