975 resultados para Ventilation artificielle
Resumo:
OBJECTIVE: To report a full-term newborn infant that developed a sepsis associated to meningitis caused by Neisseria meningitidis serogroup C on the 14th day of life. CASE DESCRIPTION: The patient was a term female infant, born to a mother with Systemic Lupus Erythematosus, with birth weight of 2,610g, Apgar Score 1, 4 and 8, who needed mechanical ventilation for 24 hours. On the 7th day of life, the neonate was discharged from the hospital with good overall condition. On the 15th day of life, the newborn infant presented fever and respiratory failure. The cerebrospinal fluid showed 1042 cells/mm³, with neutrophilic predominance, protein of 435 mg/dL, and glucose < 10 mg/dL. The blood and the cerebrospinal fluid cultures were positive for Neisseria meningitidis serogroup C. The neonate was hospitalized, needing mechanical ventilation and vasoactive drugs, and received 21 days of crystalline penicillin. After hospital discharge, there were no signs of neurological sequels and the infant was able to be breastfed. The case report presents a unique situation: an uncommon etiology of neonatal meningitis and favorable evolution, despite neurological sequels reported in the literature. This report emphasizes the need to prevent the premature exposure of newborn infants to pathological agents, especially if they presented birth injuries and/or are preterm, due to their lack of immunological capacity.
Resumo:
INTRODUCTION: A growing body of evidence shows the prognostic value of oxygen uptake efficiency slope (OUES), a cardiopulmonary exercise test (CPET) parameter derived from the logarithmic relationship between O(2) consumption (VO(2)) and minute ventilation (VE) in patients with chronic heart failure (CHF). OBJECTIVE: To evaluate the prognostic value of a new CPET parameter - peak oxygen uptake efficiency (POUE) - and to compare it with OUES in patients with CHF. METHODS: We prospectively studied 206 consecutive patients with stable CHF due to dilated cardiomyopathy - 153 male, aged 53.3±13.0 years, 35.4% of ischemic etiology, left ventricular ejection fraction 27.7±8.0%, 81.1% in sinus rhythm, 97.1% receiving ACE-Is or ARBs, 78.2% beta-blockers and 60.2% spironolactone - who performed a first maximal symptom-limited treadmill CPET, using the modified Bruce protocol. In 33% of patients an cardioverter-defibrillator (ICD) or cardiac resynchronization therapy device (CRT-D) was implanted during follow-up. Peak VO(2), percentage of predicted peak VO(2), VE/VCO(2) slope, OUES and POUE were analyzed. OUES was calculated using the formula VO(2) (l/min) = OUES (log(10)VE) + b. POUE was calculated as pVO(2) (l/min) / log(10)peakVE (l/min). Correlation coefficients between the studied parameters were obtained. The prognosis of each variable adjusted for age was evaluated through Cox proportional hazard models and R2 percent (R2%) and V index (V6) were used as measures of the predictive accuracy of events of each of these variables. Receiver operating characteristic (ROC) curves from logistic regression models were used to determine the cut-offs for OUES and POUE. RESULTS: pVO(2): 20.5±5.9; percentage of predicted peak VO(2): 68.6±18.2; VE/VCO(2) slope: 30.6±8.3; OUES: 1.85±0.61; POUE: 0.88±0.27. During a mean follow-up of 33.1±14.8 months, 45 (21.8%) patients died, 10 (4.9%) underwent urgent heart transplantation and in three patients (1.5%) a left ventricular assist device was implanted. All variables proved to be independent predictors of this combined event; however, VE/VCO2 slope was most strongly associated with events (HR 11.14). In this population, POUE was associated with a higher risk of events than OUES (HR 9.61 vs. 7.01), and was also a better predictor of events (R2: 28.91 vs. 22.37). CONCLUSION: POUE was more strongly associated with death, urgent heart transplantation and implantation of a left ventricular assist device and proved to be a better predictor of events than OUES. These results suggest that this new parameter can increase the prognostic value of CPET in patients with CHF.
Resumo:
Objectivo: estudar determinantes cardiovasculares condicionantes do tempo de ventilação, mortalidade e gravidade de doença em doentes admitidos numa unidade de cuidados intensivos para ventilação mecânica por exacerbação de insuficiência respiratória crónica. Desenho e local: Estudo prospectivo, com duração de 30 meses numa unidade de cuidados intensivos médico-cirúrgica com 14 camas.Material e métodos: Estudados 59 doentes com idade média de 74,7 +/- 9,7 anos, tempo médio de ventilação de 10,8 +/- 12,6 dias, APACHE II médio de 23 +/- 8,3. Avaliaram-se parâmetros ecocardiográficos (dimensões das cavidades, débito cardíaco, estudo Doppler do fluxo transvalvular mitral, estudo da veia cava inferior) e electrocardiográficos(presença de ritmo sinusal ou fibrilhação auricular) nas primeiras 24 horas de internamento na Unidade e parâmetros gasimétricos à saída. Resultados: Um tempo de ventilação mais prolongado associou-se à presença de fibrilhação auricular (p=0,027), à presença conjunta de fibrilhação auricular e uma veia cava inferior dilatada (> 20mm p=0,004) e com níveis séricos de bicarbonato> 35mEq/l na gasimetria obtida à saída (p=0,04). Verificaram-se 12 óbitos. A mortalidade associou-se à presença de dilatação do ventrículo direito (p=0,03) e a uma relação entre o ventrículo direito e o esquerdo> 0,6 (p=0,04). Conclusão: Nos doentes submetidos a ventilação mecânica por exacerbação de insuficiência respiratória crónica, a presença de fibrilhação auricular indica a possibilidade de um período de ventilação mais prolongado, em especial se houver concomitantemente uma veia cava inferior com diâmetro> 20mm. Nestes doentes, a presença de dilatação das cavidades direitas pode indicar uma probabilidade mais elevada de mortalidade.
Resumo:
No desmame ventilatório estão implicadas alterações hemodinâmicas, principalmente aquando da desconexão da ventilação com pressão positiva. A sua importância encontra-se insuficientemente estudada, embora alguns estudos indiquem que pode ter um papel importante no sucesso do desmame ventilatório. No presente trabalho, os autores estudaram as implicações hemodinâmicas da desconexão ventilatória utilizando a ecocardiografia, e verificaram que o tempo de relaxamento isovolumétrico é um bom preditor de sucesso de desconexão do ventilador, evidenciando a importância das alterações da diástole na adaptação hemodinâmica da passagem à ventilação com pressão negativa.
Resumo:
Background: Although epilepsy is common in children with cerebral palsy (CP), no data exists on prevalence rates of CP and epilepsy. Aims: To describe epilepsy in children with CP, and to examine the association between epilepsy and neonatal characteristics, associated impairments and CP subtypes. Methods: Data on 9654 children with CP born between 1976 and 1998 and registered in 17 European registers belonging to the SCPE network (Surveillance of Cerebral Palsy in Europe)were analyzed. Results: A total of 3424 (35%) children had a history of epilepsy. Among them, seventy-two percent were on medication at time of registration. Epilepsy was more frequent in children with a dyskinetic or bilateral spastic type and with other associated impairments. The prevalence of CP with epilepsy was 0.69 (99% CI, 0.66e0.72) per 1000 live births and followed a quadratic trend with an increase from 1976 to 1983 and a decrease afterwards. Neonatal characteristics independently associated with epilepsy were the presence of a brain malformation or a syndrome, a term or moderately preterm birth compared with a very premature birth, and signs of perinatal distress including neonatal seizures, neonatal ventilation and admission to a neonatal care unit. Conclusions: The prevalence of CP with epilepsy followed a quadratic trend in 1976e1998 and mirrored that of the prevalence of CP during this period. The observed relationship between epilepsy and associated impairments was expected; however it requires longitudinal studies to be better understood.
Resumo:
Background: Acute kidney injury in the pandemic swine origin influenza A virus (H1N1) infection has been reported as coursing with severe illness, although renal pathogenic mechanisms and histologic features are still being characterised. Case Report: We present two patients admitted with H1N1 pneumonia, sepsis, acute respiratory distress syndrome and need for invasive mechanical ventilation who developed acute kidney injury and became dialysis-dependent. In both cases a kidney biopsy was performed to establish a definitive diagnosis. Severe acute tubular necrosis was identified, with no further abnormalities. Conclusion: This report seems to confirm that the acute kidney injury in H1N1 infection is focused on the tubular cells. Our cases corroborate the renal histopathologic findings of other studies, highlighting the central role of the tubular cell. We bring new evidence of the histopathology of AKI in H1N1 infection since our data were collected in living patients and not via post-mortem studies.
Resumo:
Two cases of proven coral snake bites were reported in Belém, Pará State, Brazil. The first case was a severe one caused by Micrurus surinamensis. The patient required mechanical ventilation due to acute respiratory failure. The second case showed just mild signs of envenomation caused by Micrurus filiformis. Both patients received specific Micrurus antivenom and were discharged without further complications. Coral snake bites are scarcely reported in the Amazon region and there is a broad spectrum of clinical manifestations, varying from extremely mild to those which may rapidly lead to death if the patient is not treated as soon as possible.
Resumo:
Objectivo: avaliar e caracterizar a linfopenia em doentes admitidos numa unidade de cuidados intensivos para suporte ventilatório por exacerbação de insuficiência respiratória crónica e eventual relação com a gravidade da doença. Material e métodos: estudo prospectivo com 6 meses de duração e mais 6 meses de seguimento após alta da unidade. Incluídos 24 doentes, 22 homens, com APACHE II médio de 19,7, 3 dos quais com possibilidade de seguimento após a alta. Foram colhidas análises para determinação das subpopulações linfocitárias na admissão e a cada 7 dias de ventilação mecânica. Excluídos doentes com sinais de infecção ou imunossupressão prévia, à excepção dos corticóides. Resultados: a linfopenia foi encontrada em 79,2 % dos doentes com depleção de todas as subpopulações linfocitárias sendo mais expressiva a depleção de linfócitos B CD19+. Esta linfopenia não se relacionou com os níveis séricos de cortisol, e apesar de se relacionar com uma maior gravidade clínica não esteve associada a uma maior mortalidade. O registo evolutivo no internamento mostrou tendencialmente uma recuperação da linfopenia. Conclusões: a linfopenia é frequente em doentes ventilados por exacerbação de doença respiratória crónica. Trata-se de uma linfopenia não selectiva, que recupera ao longo do internamento, mais acentuada ao nível dos linfócitos B CD19+. Estes doentes apresentam índices de gravidade maior mas sem diferenças na mortalidade. O seguimento ambulatório destes doentes mostrou-se difícil e foi inconclusivo.
Resumo:
Objectives: To retrospectively review the hybrid treatment of the aortic arch with supra-aortic debranching and endo- vascular stent-graft repair in a single institution. Methods: From 2007 to 2010, all patients submitted to aortic debranching procedures were entered into a prospective database analysis. For the present study, only patients with sealing zones 0 and 1, according to the Ishimaru classification, were included. Procedure-related morbimortality was analysed for the open and endovascular procedures. Results: During the study period, we electively performed 6 total aortic debranching and 4 partial aortic debranching procedures in 10 patients. According to the etiology the indications were: 6 aortic arch aneurysms, 2 post-dissection aneu- rysms, 1 false aneurysm and 1 type I endoleak following TEVAR. The proximal sealing zone was Ishimaru zone 0 in six patients and zone 1 in four patients. The TEVAR procedure was delayed in all patients with a completion success of 80% (1 patient died from ruptured aortic aneurysm; 1 patient denied the second procedure and was lost to follow-up). The 30d mortality rate was 10% (patient mentioned above). The main morbidity was: 1 axillar venous thrombosis, 1 case of subclinical myocardial infarction, 1 case of terminal renal insufficiency and 1 case of prolonged ventilation. No permanent cerebral or peripheral neurologic deficit was noted. Conclusions: The hybrid repair of the aortic arch is a feasible and reproducible procedure, and our results are similar to the previously published series. Medium and long-term results are necessary to confirm whether the technique can be regarded as a safe alternative to open surgery in high-risk patients.
Resumo:
O estágio descrito por este relatório efetuou-se na fábrica Massas 1 da empresa Cerealis Produtos Alimentares S.A., situada em Águas Santas e teve como principal objetivo o estudo do impacto energético da instalação de um sistema de Aquecimento, Ventilação e Ar Condicionado (AVAC) nos Consumos Específicos de Energia (CEE) da fábrica. Com o intuito de promover a familiarização com o ambiente da empresa e com o próprio processo produtivo efetuaram-se várias visitas à fábrica Massas 1. Acompanhou-se a produção diária realizada e o funcionamento do equipamento, e pôde-se questionar os colaboradores da fábrica sobre o processo. Ao longo do tempo de estágio recolheram-se vários dados, nomeadamente valores de temperatura e de humidade relativa do ar da fábrica, consumos de energia elétrica e de gás natural, volumes de produção e dados relativos à qualidade da massa. Relativamente ao CEE, fez-se uma comparação entre quatro meses abrangidos pelo presente trabalho, nos quais o novo sistema AVAC já se encontrava em funcionamento, e os meses homólogos do ano anterior. Confrontando os valores obtidos verificou-se uma diminuição de 2,6% no valor global de CEE, apresentando este um valor de 82,51 kgep/ton até ao mês de Setembro do presente ano. Analisando os valores de CEE da energia elétrica e do gás natural separadamente, constatou-se igualmente uma diminuição dos seus valores em 1,4% e 4,2%, respetivamente. Efetuou-se também uma comparação entre o antigo e o novo sistema AVAC no que respeita às condições de temperatura e de humidade do ar interior da fábrica. Para isso efetuaram-se medições de temperatura e de humidade relativa do ar interior da fábrica, tendo-se concluído que após a instalação do novo AVAC ocorreu uma diminuição da temperatura e um aumento da humidade relativa do ar, tal como desejado. Antes da instalação do novo AVAC a gama de temperaturas no interior da fábrica era de 32,4°C a 39,7°C e a gama de humidades de 39,7% a 58,6%. Já depois da instalação, a gama de temperaturas e de humidades passou a ser de 26,6°C a 33,5°C e de 45,8% a 59,1%, respetivamente Realizou-se ainda uma comparação relativa à qualidade do produto final, tendose para isso analisado ensaios de cozedura e de teor de humidade. Desta comparação, concluiu-se que de uma forma geral houve um aumento dos teores de humidade dos diferentes tipos de massa, encontrando-se agora uma maior percentagem dentro da gama de valores pretendida que se situa entre os 11,5% e os 12,5%.
Resumo:
A crescente incorporação das evoluções tecnológicas nos equipamentos médicos modernos, além de os tornar mais compactos e precisos, proporciona igualmente ganhos de outros benefícios importantes, especialmente ao nível da eficiência das terapias prescritas aos pacientes. Os sofisticados ventiladores pulmonares de cuidados intensivos do presente espelham perfeitamente esta realidade e por isso necessitam de procedimentos técnicos de verificação metrológica – calibrações, também eles mais exatos e rastreáveis, de modo a fornecerem informações corretas sobre se o estado de funcionamento de um determinado ventilador cumpre ou não as tolerâncias declaradas pelo seu fabricante. Através da presente dissertação pretendeu-se desenvolver um procedimento técnico de calibração dos ventiladores de cuidados intensivos tendo-se estudado, para esta finalidade, os equipamentos de calibração específicos disponíveis no mercado, a normalização e o enquadramento regulamentar do controlo metrológico aplicáveis, bem como o princípio de funcionamento do ventilador pulmonar e a evolução da ventilação mecânica ocorrida. No domínio da abordagem efetuada sobre o âmbito da metrologia, implementou-se a determinação das incertezas dos resultados das calibrações efetuadas pelo procedimento técnico desenvolvido, de acordo com a metodologia constante do GUM1. Considerando ainda os défices significativos de conhecimento da metrologia e da prática do controlo metrológico no setor da saúde, a par dos riscos inerentes para os próprios pacientes, procura-se contribuir com este trabalho, de uma forma transversal e ampla, para uma maior consciencialização, quer dos profissionais de saúde, quer dos gestores envolvidos, para a relevância da realização das calibrações periódicas dos complexos equipamentos de suporte de vida que são os ventiladores pulmonares de cuidados intensivos.
Resumo:
BACKGROUND: Upper gastrointestinal bleeding is the severe complication of stress-related mucosal disease in hospitalized patients. In intensive care units (ICU), risk factors are well defined and only mechanical ventilation and coagulopathy proved to be relevant for significant bleeding. On the contrary, in non-ICU settings there is no consensus about this issue. Nevertheless, omeprazole is still widely used in prophylaxis of bleeding. The objective of our study was to evaluate the relevance of stress-related mucosal disease bleeding in patients admitted to an internal medicine ward, and the role of omeprazole in its prophylaxis. METHODS: We conducted a retrospective study in which we analysed consecutive patients who were admitted to our ward over a year. We recorded demographic characteristics of the patients, potential risk factors for stress-related mucosal disease (clinical data, laboratory, and medication), administration of prophylactic omeprazole, and total cost of this prophylaxis. Patients with active gastrointestinal bleeding on the admission were excluded. We recorded every upper gastrointestinal bleeding event with clinical relevance. RESULTS: Five hundred and thirty-five patients, mean age 70 years, mean length of stay 9.6+/-7.7 days; 140 (26.2%) patients were treated with 40 mg of omeprazole intravenously, 193 (36.1%) with 20mg of omeprazole orally, and 202 (37.8%) patients had no prophylaxis. There was only one episode (0.2%) of clinically relevant bleeding. CONCLUSION: In patients admitted to an internal medicine ward, incidence of upper gastrointestinal bleeding as a complication of stress-related mucosal disease is low. We found that there is no advantage in prophylaxis with omeprazole.
Resumo:
Poor ventilation at day care centres (DCCs) was already reported, although its effects on attending children are not clear. This study aimed to evaluate the association between wheezing in children and indoor CO2 (a ventilation surrogate marker) in DCC and to identify behaviours and building characteristics potentially related to CO2. In phase I, 45 DCCs from Lisbon and Oporto (Portugal) were selected through a proportional stratified random sampling. In phase II, 3 months later, 19 DCCs were further reassessed after cluster analysis for the greatest difference comparison. In both phases, children’s respiratory health was assessed by ISAAC-derived questionnaires. Indoor CO2 concentrations and building characteristics of the DCC were evaluated in both phases, using complementary methods. Mixed effect models were used to analyze the data. In phase I, which included 3,186 children (mean age 3.1±1.5 years), indoor CO2 concentration in the DCC rooms was associated with reported wheezing in the past 12months (27.5 %) (adjusted odds ratio (OR) for each increase of 200 ppm 1.04, 95 % CI 1:01 to 1:07). In phase II, the association in the subsample of 1,196 children seen in 19 out of the initial 45 DCCs was not significant (adjusted OR 1.02, 95 % CI 0.96 to 1.08). Indoor CO2 concentration was inversely associated with the practices of opening Windows and internal doors and with higher wind velocity. A positive trend was observed between CO2 and prevalence of reported asthma (4.7 %). Conclusion: Improved ventilation is needed to achieve a healthier indoor environment in DCC.
Resumo:
Background: Indoor air quality (IAQ) is considered an important determinant of human health. The association between exposure to volatile organic compounds, particulate matter, house dust mite, molds and bacteria in day care centers (DCC) is not completely clear. The aim of this project was to study these effects. Methods --- study design: This study comprised two phases. Phase I included an evaluation of 45 DCCs (25 from Lisbon and 20 from Oporto, targeting 5161 children). In this phase, building characteristics, indoor CO2 and air temperature/relative humidity, were assessed. A children’s respiratory health questionnaire derived from the ISAAC (International Study on Asthma and Allergies in Children) was also distributed. Phase II encompassed two evaluations and included 20 DCCs selected from phase I after a cluster analysis (11 from Lisbon and 9 from Oporto, targeting 2287 children). In this phase, data on ventilation, IAQ, thermal comfort parameters, respiratory and allergic health, airway inflammation biomarkers, respiratory virus infection patterns and parental and child stress were collected. Results: In Phase I, building characteristics, occupant behavior and ventilation surrogates were collected from all DCCs. The response rate of the questionnaire was 61.7% (3186 children). Phase II included 1221 children. Association results between DCC characteristics, IAQ and health outcomes will be provided in order to support recommendations on IAQ and children’s health. A building ventilation model will also be developed. Discussion: This paper outlines methods that might be implemented by other investigators conducting studies on the association between respiratory health and indoor air quality at DCC.
Resumo:
Objectivo: A Ventilação de Alta Frequência Oscilatória (VAFO) tem ainda poucos anos de utilização em Portugal. Os seus resultados pouco uniformes têm sido relacionados com o tipo de estratégia utilizada. A optimização do volume pulmonar com utilização de uma estratégia de alto volume, tem vindo a definir-se como a estratégia mais eficaz. Considerámos como objectivos prioritários, a avaliação dos benefícios desta técnica na redução da mortalidade e na redução da morbilidade respiratória precoce e tardia, na retinopatia da prematuridade (ROP) e na hemorragia intraperiventricular (HIPV). Doentes e Métodos: Desde 1 de Janeiro de 1999 até 31 de Março de 2000 (15 meses), usámos esta estratégia ventilatória no Recém Nascido de Muito Baixo Peso (RN MBP). Utilizámos VAFO como modalidade ventilatória exclusiva e imediatamente após intubação traqueal ou após chegada do RN à Unidade de Cuidados Intensivos neonatais (UCIN). Iniciámos de imediato a Optimização do Volume Pulmonar (OPT). A administração de surfactante só foi efectuada após critério de pulmão optimizado. Foram ventilados com esta técnica, 154 RN com idade gestacional < 34 semanas com DMH/SDR e necessitando de ventilação mecânica. Destes RN, o grupo com peso de nascimento (PN) < 950 gramas e idade gestacional entre 25-29 semanas (Coorte VAFO/OPT = 36 RN) foi comparado com uma Coorte histórica de VAFO após curto período de ventilação convencional (VC) de 1997-1998 (grupo VC + VAFO = 27 RN). Ambos os grupos tiveram a Doença das Membranas Hialinas(DMH) como diagnóstico primário. Local de Estudo: Unidade de Cuidados Intensivos Neonatais da Maternidade Dr. Alfredo da Costa (12 postos de ventilação permanente). Resultados: Os dois grupos comparados (VAFO/OPT e VC + VAFO) foram semelhantes nos dados demográficos (peso, idade gestacional, sexo), corticoterapia pré-natal e gravidade radiológica da DMH. Apesar da gravidade radiológica de ambos os grupos ser semelhante, o tipo de estratégia ventilatória utilizada no grupo VAFO/OPT, ou seja, a optimização do volume pulmonar, permitiu uma menor administração do surfactante. O tempo de ventilação e o tempo de oxigenação (dias de 02) foi estatisticamente inferior no grupo VAFO/OPT (respectivamente p=0,000 e p=0.003), tal como a HIPV, ROP e mortalidade (respectivamente p=0,0029, p=0,009 e p=0,031). A Doença Pulmonar Crónica (DPC) foi percentualmente bastante inferior neste grupo (p=0,051). Conclusão: A VAFO como modalidade ventilatória exclusiva, iniciada imediatamente após intubação traqueal e/ou chegada do RN à UCIN e com optimização do volume pulmonar, encurtou a necessidade de suporte respiratório e de oxigenação e melhorou a morbilidade pulmonar no RN MBP com DMH.