902 resultados para Incidental parameter bias
Resumo:
Redshift Space Distortions (RSD) are an apparent anisotropy in the distribution of galaxies due to their peculiar motion. These features are imprinted in the correlation function of galaxies, which describes how these structures distribute around each other. RSD can be represented by a distortions parameter $\beta$, which is strictly related to the growth of cosmic structures. For this reason, measurements of RSD can be exploited to give constraints on the cosmological parameters, such us for example the neutrino mass. Neutrinos are neutral subatomic particles that come with three flavours, the electron, the muon and the tau neutrino. Their mass differences can be measured in the oscillation experiments. Information on the absolute scale of neutrino mass can come from cosmology, since neutrinos leave a characteristic imprint on the large scale structure of the universe. The aim of this thesis is to provide constraints on the accuracy with which neutrino mass can be estimated when expoiting measurements of RSD. In particular we want to describe how the error on the neutrino mass estimate depends on three fundamental parameters of a galaxy redshift survey: the density of the catalogue, the bias of the sample considered and the volume observed. In doing this we make use of the BASICC Simulation from which we extract a series of dark matter halo catalogues, characterized by different value of bias, density and volume. This mock data are analysed via a Markov Chain Monte Carlo procedure, in order to estimate the neutrino mass fraction, using the software package CosmoMC, which has been conveniently modified. In this way we are able to extract a fitting formula describing our measurements, which can be used to forecast the precision reachable in future surveys like Euclid, using this kind of observations.
Resumo:
A new control scheme has been presented in this thesis. Based on the NonLinear Geometric Approach, the proposed Active Control System represents a new way to see the reconfigurable controllers for aerospace applications. The presence of the Diagnosis module (providing the estimation of generic signals which, based on the case, can be faults, disturbances or system parameters), mean feature of the depicted Active Control System, is a characteristic shared by three well known control systems: the Active Fault Tolerant Controls, the Indirect Adaptive Controls and the Active Disturbance Rejection Controls. The standard NonLinear Geometric Approach (NLGA) has been accurately investigated and than improved to extend its applicability to more complex models. The standard NLGA procedure has been modified to take account of feasible and estimable sets of unknown signals. Furthermore the application of the Singular Perturbations approximation has led to the solution of Detection and Isolation problems in scenarios too complex to be solved by the standard NLGA. Also the estimation process has been improved, where multiple redundant measuremtent are available, by the introduction of a new algorithm, here called "Least Squares - Sliding Mode". It guarantees optimality, in the sense of the least squares, and finite estimation time, in the sense of the sliding mode. The Active Control System concept has been formalized in two controller: a nonlinear backstepping controller and a nonlinear composite controller. Particularly interesting is the integration, in the controller design, of the estimations coming from the Diagnosis module. Stability proofs are provided for both the control schemes. Finally, different applications in aerospace have been provided to show the applicability and the effectiveness of the proposed NLGA-based Active Control System.
Resumo:
Diese Arbeit beschreibt die Entwicklung des flugzeuggetragenen Atmosphärischen Ionisations-Massenspektrometers AIMS-H2O zur Messung von Wasserdampf in der oberen Troposphäre und unteren Stratosphäre (UTLS) und erste Flugzeugmessungen mit dem Instrument. Wasserdampf beeinflusst das Klima in der UTLS aufgrund seiner Strahlungseigenschaften und agiert als wichtiger Parameter bei der Bildung von Zirruswolken und Kondensstreifen. Deshalb sind genaue Wasserdampfmessungen für das Verständnis vieler atmosphärischer Prozesse unerlässlich. Instrumentenvergleiche wie sie im SPARC Report No. 2 und dem Bericht der AUQAVIT Kampagne zusammengefasst sind, haben gezeigt, dass große Abweichungen zwischen einzelnen Methoden und Instrumenten bestehen. Diese Unsicherheiten limitieren das Verständnis des Einflusses von Wasserdampf auf die Dynamik und die Strahlungseigenschaften in der UTLS. Die in dieser Arbeit vorgestellte Entwicklung einer neuen Messmethode für Wasserdampf mit dem Massenspektrometer AIMS-H2O ist deshalb auf die genaue Messung niedriger Wasserdampfkonzentrationen in der UTLS fokussiert. Mit AIMS H2O wird Umgebungsluft in einer neu entwickelten Gasentladungsquelle ionisiert. Durch eine Reihe von Ionen-Molekül-Reaktionen entstehen H3O+(H2O) und H3O+(H2O)2 Ionen. Diese Ionen werden genutzt, um die Wasserdampfkonzentration in der Atmosphäre zu bestimmen. Um die erforderliche hohe Genauigkeit zu erzielen, wird AIMS H2O im Flug kalibriert. In dem zu diesem Zweck aufgebauten Kalibrationsmodul wird die katalytische Reaktion von Wasserstoff und Sauerstoff auf einer Platinoberfläche genutzt, um definierte Wasserdampfkonzentrationen für die Kalibration im Flug zu erzeugen. Bei ersten Messungen auf der Falcon während der Kampagne CONCERT 2011 konnte dabei eine Genauigkeit von 8 bis 15% für die Messung der Wasserdampfkonzentration in einem Messbereich von 0,5 bis 250 ppmv erreicht werden. Die Messfrequenz betrug 4 Hz, was einer räumlichen Auflösung von etwa 50 m entspricht. Der Vergleich der Messung des Massenspektrometers mit dem Laserhygrometer Waran zeigt eine sehr gute Übereinstimmung im Rahmen der Unsicherheiten. Anhand zweier Fallstudien werden die Messungen von AIMS H2O während CONCERT 2011 detailliert analysiert. In der ersten Studie werden zwei Flüge in eine stratosphärische Intrusion über Nordeuropa untersucht. In dieser Situation wurde stratosphärische Luft bis hinunter auf 6 km Höhe transportiert und war dadurch mit der Falcon erreichbar. Es konnte gezeigt werden, dass AIMS-H2O sehr gut für die genaue Messung niedriger Wasserdampfkonzentrationen, in diesem Fall bis etwa 3,5 ppmv, geeignet ist. Der Vergleich der Messung mit Analysen des ECMWF Integrated Forecast Systems zeigt eine gute Übereinstimmung der gemessenen Wasserdampfstrukturen mit der dynamischen Tropopause. Unterschiede tauchen dagegen beim Vergleich der Wasserdampfkonzentrationen in der unteren Stratosphäre auf. Hier prognostiziert das Modell deutlich höhere Feuchten. Die zweite Fallstudie beschäftigt sich mit der Verteilung der relativen Feuchte in jungen Kondensstreifen im Vergleich zu ihrer direkten Umgebung. Dabei wurde für drei Messsequenzen im Abgasstrahl von Flugzeugen beobachtet, dass die relative Feuchte innerhalb des Kondensstreifens im Vergleich zur Umgebung sowohl bei unter- als auch übersättigten Umgebungsbedingungen in Richtung Sättigung verschoben ist. Die hohe Anzahl an Eispartikeln und die damit verbundene große Eisoberfläche in jungen Kondensstreifen führt also zu einer schnellen Relaxation von Gasphase und Eis in Richtung Gleichgewicht. In der Zukunft soll AIMS-H2O auch auf HALO für die genaue Messung von Wasserdampf bei ML-CIRRUS und weiteren Kampagnen eingesetzt werden.
Resumo:
Aerosol particles are strongly related to climate, air quality, visibility and human health issues. They contribute the largest uncertainty in the assessment of the Earth´s radiative budget, directly by scattering or absorbing solar radiation or indirectly by nucleating cloud droplets. The influence of aerosol particles on cloud related climatic effects essentially depends upon their number concentration, size and chemical composition. A major part of submicron aerosol consists of secondary organic aerosol (SOA) that is formed in the atmosphere by the oxidation of volatile organic compounds. SOA can comprise a highly diverse spectrum of compounds that undergo continuous chemical transformations in the atmosphere.rnThe aim of this work was to obtain insights into the complexity of ambient SOA by the application of advanced mass spectrometric techniques. Therefore, an atmospheric pressure chemical ionization ion trap mass spectrometer (APCI-IT-MS) was applied in the field, facilitating the measurement of ions of the intact molecular organic species. Furthermore, the high measurement frequency provided insights into SOA composition and chemical transformation processes on a high temporal resolution. Within different comprehensive field campaigns, online measurements of particular biogenic organic acids were achieved by combining an online aerosol concentrator with the APCI-IT-MS. A holistic picture of the ambient organic aerosol was obtained through the co-located application of other complementary MS techniques, such as aerosol mass spectrometry (AMS) or filter sampling for the analysis by liquid chromatography / ultrahigh resolution mass spectrometry (LC/UHRMS).rnIn particular, during a summertime field study at the pristine boreal forest station in Hyytiälä, Finland, the partitioning of organic acids between gas and particle phase was quantified, based on the online APCI-IT-MS and AMS measurements. It was found that low volatile compounds reside to a large extent in the gas phase. This observation can be interpreted as a consequence of large aerosol equilibration timescales, which build up due to the continuous production of low volatile compounds in the gas phase and/or a semi-solid phase state of the ambient aerosol. Furthermore, in-situ structural informations of particular compounds were achieved by using the MS/MS mode of the ion trap. The comparison to MS/MS spectra from laboratory generated SOA of specific monoterpene precursors indicated that laboratory SOA barely depicts the complexity of ambient SOA. Moreover, it was shown that the mass spectra of the laboratory SOA more closely resemble the ambient gas phase composition, indicating that the oxidation state of the ambient organic compounds in the particle phase is underestimated by the comparison to laboratory ozonolysis. These observations suggest that the micro-scale processes, such as the chemistry of aerosol aging or the gas-to-particle partitioning, need to be better understood in order to predict SOA concentrations more reliably.rnDuring a field study at the Mt. Kleiner Feldberg, Germany, a slightly different aerosol concentrator / APCI-IT-MS setup made the online analysis of new particle formation possible. During a particular nucleation event, the online mass spectra indicated that organic compounds of approximately 300 Da are main constituents of the bulk aerosol during ambient new particle formation. Co-located filter analysis by LC/UHRMS analysis supported these findings and furthermore allowed to determine the molecular formulas of the involved organic compounds. The unambiguous identification of several oxidized C 15 compounds indicated that oxidation products of sesquiterpenes can be important compounds for the initial formation and subsequent growth of atmospheric nanoparticles.rnThe LC/UHRMS analysis furthermore revealed that considerable amounts of organosulfates and nitrooxy organosulfates were detected on the filter samples. Indeed, it was found that several nitrooxy organosulfate related APCI-IT-MS mass traces were simultaneously enhanced. Concurrent particle phase ion chromatography and AMS measurements indicated a strong bias between inorganic sulfate and total sulfate concentrations, supporting the assumption that substantial amounts of sulfate was bonded to organic molecules.rnFinally, the comprehensive chemical analysis of the aerosol composition was compared to the hygroscopicity parameter kappa, which was derived from cloud condensation nuclei (CCN) measurements. Simultaneously, organic aerosol aging was observed by the evolution of a ratio between a second and a first generation biogenic oxidation product. It was found that this aging proxy positively correlates with increasing hygroscopicity. Moreover, it was observed that the bonding of sulfate to organic molecules leads to a significant reduction of kappa, compared to an internal mixture of the same mass fractions of purely inorganic sulfate and organic molecules. Concluding, it has been shown within this thesis that the application of modern mass spectrometric techniques allows for detailed insights into chemical and physico-chemical processes of atmospheric aerosols.rn
Resumo:
During short-term postural changes, the factors determining the amplitude of intracranial pulse pressure (ICPPA) remain constant, except for cerebrovascular resistance (CVR). Therefore, it may be possible to draw conclusions from the ICPPA onto the cerebrovascular resistance (CVR) and thus the relative change in cerebral perfusion pressure (CPP).
Resumo:
Saccadic performance depends on the requirements of the current trial, but also may be influenced by other trials in the same experiment. This effect of trial context has been investigated most for saccadic error rate and reaction time but seldom for the positional accuracy of saccadic landing points. We investigated whether the direction of saccades towards one goal is affected by the location of a second goal used in other trials in the same experimental block. In our first experiment, landing points ('endpoints') of antisaccades but not prosaccades were shifted towards the location of the alternate goal. This spatial bias decreased with increasing angular separation between the current and alternative goals. In a second experiment, we explored whether expectancy about the goal location was responsible for the biasing of the saccadic endpoint. For this, we used a condition where the saccadic goal randomly changed from one trial to the next between locations on, above or below the horizontal meridian. We modulated the prior probability of the alternate-goal location by showing cues prior to stimulus onset. The results showed that expectation about the possible positions of the saccadic goal is sufficient to bias saccadic endpoints and can account for at least part of this phenomenon of 'alternate-goal bias'.
Resumo:
OBJECTIVE: The purpose of this study was to investigate the presence of publication bias (acceptance of articles indicating statistically significant results). METHODS: The journals possessing the highest impact factor (2008 data) in each dental specialty were included in the study. The content of the 6 most recent issues of each journal was hand searched and research articles were classified into 4 type categories: cross-sectional, case-control, cohort, and interventional (nonrandomized clinical trials and randomized controlled trials). In total, 396 articles were included in the analysis. Descriptive statistics and univariate and multivariate logistic regression was used to examine the association between article-reported statistical significance (dependent variable) and journal impact factor and article study type subject area (independent variables). RESULTS: A statistically significant acceptance rate of positive result was found, ranging from 75% to 90%, whereas the value of impact factor was not related to publication bias among leading dental journals. Compared with other research designs, clinical intervention studies (randomized or nonrandomized) presented the highest percentage of nonsignificant findings (20%); RCTs represented 6% of the examined investigations. CONCLUSIONS: Compared with the Journal of Clinical Periodontology, all other subspecialty journals, except the Journal of Oral and Maxillofacial Surgery, showed significantly decreased odds of publishing an RCT, which ranged from 60% to 93% (P < .05).
Resumo:
It has been suggested that participant withdrawal from studies can bias estimates. However, this is only possible when withdrawers and nonwithdrawers differ in an important way. We tested the hypothesis that withdrawers are more likely than nonwithdrawers to be avoidant and negatively affected.
Resumo:
This case report describes the incidental finding of a calcified ligamentum arteriosum during post-mortem CT examination. The calcification of the ligament was confirmed at autopsy. Subsequent histological examination revealed the presence of cartilage-like and bone-like tissue as well as extended calcification areas. The importance of not confusing this normal post-mortem CT finding with vessel pathology is being emphasized.
Resumo:
To determine the frequency of incidental maxillary sinus findings using cone-beam computed tomography (CBCT) images made for orthodontic purposes.
Resumo:
Neglect is defined as the failure to attend and to orient to the contralesional side of space. A horizontal bias towards the right visual field is a classical finding in patients who suffered from a right-hemispheric stroke. The vertical dimension of spatial attention orienting has only sparsely been investigated so far. The aim of this study was to investigate the specificity of this vertical bias by means of a search task, which taps a more pronounced top-down attentional component. Eye movements and behavioural search performance were measured in thirteen patients with left-sided neglect after right hemispheric stroke and in thirteen age-matched controls. Concerning behavioural performance, patients found significantly less targets than healthy controls in both the upper and lower left quadrant. However, when targets were located in the lower left quadrant, patients needed more visual fixations (and therefore longer search time) to find them, suggesting a time-dependent vertical bias.
Resumo:
Background Leg edema is a common manifestation of various underlying pathologies. Reliable measurement tools are required to quantify edema and monitor therapeutic interventions. Aim of the present work was to investigate the reproducibility of optoelectronic leg volumetry over 3 weeks' time period and to eliminate daytime related within-individual variability. Methods Optoelectronic leg volumetry was performed in 63 hairdressers (mean age 45 ± 16 years, 85.7% female) in standing position twice within a minute for each leg and repeated after 3 weeks. Both lower leg (legBD) and whole limb (limbBF) volumetry were analysed. Reproducibility was expressed as analytical and within-individual coefficients of variance (CVA, CVW), and as intra-class correlation coefficients (ICC). Results A total of 492 leg volume measurements were analysed. Both legBD and limbBF volumetry were highly reproducible with CVA of 0.5% and 0.7%, respectively. Within-individual reproducibility of legBD and limbBF volumetry over a three weeks' period was high (CVW 1.3% for both; ICC 0.99 for both). At both visits, the second measurement revealed a significantly higher volume compared to the first measurement with a mean increase of 7.3 ml ± 14.1 (0.33% ± 0.58%) for legBD and 30.1 ml ± 48.5 ml (0.52% ± 0.79%) for limbBF volume. A significant linear correlation between absolute and relative leg volume differences and the difference of exact day time of measurement between the two study visits was found (P < .001). A therefore determined time-correction formula permitted further improvement of CVW. Conclusions Leg volume changes can be reliably assessed by optoelectronic leg volumetry at a single time point and over a 3 weeks' time period. However, volumetry results are biased by orthostatic and daytime-related volume changes. The bias for day-time related volume changes can be minimized by a time-correction formula.