981 resultados para Colius, Jacobus, 1563-1628.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recently, was proposed a chemical method for preparation of ferroelectric thin films based on oxide precursors. In this work, PZT thin films were prepared to attest the viability of this method for cation-substitution. In this study, a small concentration of Nb (5 mol%) was selected as substitute of B-site in ABO 3 structure of PZT. Dielectric and ferroelectric properties of PZT films were studied as a function of cation-substitution. Results for Nb-PZT were compared with PZT films undoped. The values of dielectric constant, at typical 100 kHz frequency, were 358 and 137, for PZT and Nb-PZT films respectively. Remanent polarizations of these films were respectively 7.33 μ C/cm 2 and 13.3 μ C/cm 2 , while the measured coercive fields were 101 kV/cm and 93 kV/cm. As a result, changes on observed dielectric and ferroelectric values confirm the Nb substitution in PZT thin film produced by oxide precursor method. © 2002 Taylor & Francis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Polymeric precursor solution (Pechini method) was used to deposit LiNbO 3 thin films by spin-coating on (100) silicon substrates. X-ray diffraction data of thin films showed that the increase of oxygen flow promotes a preferred orientation of (001) LiNbO 3 planes parallel to the substrate surface. Surface roughness and grain size, observed by atomic force microscopy, change also with oxygen flow. © 2002 Taylor & Francis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Strontium bismuth tantalate thin films were prepared on several substrates (platinized silicon (Pt/Ti/SiO 2 /Si), n -type (100)-oriented and p -type (111)-oriented silicon wafers, and fused silica) by the solution deposition method. The resin was obtained by the polymeric precursor method, based on the Pechini process, using strontium carbonate, bismuth oxide, and tantalum ethoxide as starting reagents. Characterizations by XRD and SEM were performed for structural and microstructural evaluations. The electrical measurements, carried on the MFM configuration, showed P r values of 6.24 μC/cm 2 and 31.5 kV/cm for the film annealed at 800 C. The film deposited onto fused silica and treated at 700 C presented around 80% of transmittance. © 2002 Taylor & Francis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the diagnostic agreement of conventional panoramic radiographs and their inverted scanned images in the detection of the mandibular canal and mental foramen. A total of 77 panoramic radiographs obtained from the files of totally edentulous patients were used. Digitization was done by means of a scanner with brightness and contrast adjustment, as well as image inversion. The extension of mandibular canal was divided into anterior, middle, and posterior regions, and the presence of a radiopaque line that characterized the mandibular canal was classified according to a 5-point confidence scale. The mental foramen was classified in 4 types: continuous, separated, diffuse, and unidentified. Both conventional and inverted scanned panoramic radiographs were evaluated by 3 calibrated implantologists at 2 distinct moments with a minimum interval of 10 days between them. Intraexaminer agreement was evaluated by Kappa statistics by point and by 95% confidence interval. Because the intraexaminer level of agreement was low, interexaminer agreements could not be carried out. The results showed a substantial (in 2 situations), moderate (in 16 situations), and fair (in 18 situations) intraexaminer agreement for mandibular canal and a substantial (in 1 situation), fair (in 1 situation), and moderate (in 10 situations) intraeaminer agreement for mental foramen. There were no statistically significant differences in most instances. In conclusion, the diagnostic agreement of conventional and inverted scanned panoramic radiographs for detection of mandibular canal and mental foramen was low.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Brazilian National Institute for Space Research (INPE) is operating the Brazilian Environmental Data Collection System that currently amounts to a user community of around 100 organizations and more than 700 data collection platforms installed in Brazil. This system uses the SCD-1, SCD-2, and CBERS-2 low Earth orbit satellites to accomplish the data collection services. The main system applications are hydrology, meteorology, oceanography, water quality, and others. One of the functionalities offered by this system is the geographic localization of the data collection platforms by using Doppler shifts and a batch estimator based on least-squares technique. There is a growing demand to improve the quality of the geographical location of data collection platforms for animal tracking. This work presents an evaluation of the ionospheric and tropospheric effects on the Brazilian Environmental Data Collection System transmitter geographic location. Some models of the ionosphere and troposphere are presented to simulate their impacts and to evaluate performance of the platform location algorithm. The results of the Doppler shift measurements, using the SCD-2 satellite and the data collection platform (DCP) located in Cuiabá town, are presented and discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to survey radiographic measurement estimation in the assessment of dental implant length according to dentists' confidence. A 19-point questionnaire with closed-ended questions was used by two graduate students to interview 69 dentists during a dental implant meeting. Included were 12 questions related to over- and underestimation in three radiographic modalities: panoramic (P), conventional tomography (T), and computerized tomography (CT). The database was analyzed by Epi-Info 6.04 software and the values from two radiographic modalities, P and T, were compared using a chi2 test. The results showed that 38.24% of the dentists' confidence was in the overestimation of measurements in P, 30.56% in T, and 0% in CT. On the other hand, considering the underestimated measurements, the percentages were 47.06% in P, 33.33% in T, and 1.92% in CT. The frequency of under- and overestimation were statistically significant (chi2 = 6.32; P = .0425) between P and T. CT was the radiographic modality with higher measurement precision according to dentists' confidence. In conclusion, the interviewed dentists felt that CT was the best radiographic modality when considering the measurement estimation precision in preoperative dental implant assessment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An analysis of the active pixel sensor (APS), considering the doping profiles of the photodiode in an APS fabricated in a 0.18 μm standard CMOS technology, is presented. A simple and accurate model for the junction capacitance of the photodiode is proposed. An analytic expression for the output voltage of the APS obtained with this capacitance model is in good agreement with measurements and is more accurate than the models used previously. A different mode of operation for the APS based on the dc level of the output is suggested. This new mode has better low-light-level sensitivity than the conventional APS operating mode, and it has a slower temporal response to the change of the incident light power. At 1μW/cm2 and lower levels of light, the measured signal-to-noise ratio (SNR) of this new mode is more than 10 dB higher than the SNR of previously reported APS circuits. Also, with an output SNR of about 10 dB, the proposed dc level is capable of detecting light powers as low as 20 nW/cm2, which is about 30 times lower than the light power detected in recent reports by other groups. © 2007 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel multisampling time-domain architecture for CMOS imagers with synchronous readout and wide dynamic range is proposed. The architecture was implemented in a prototype of imager with 32x32 pixel array fabricated in AMS CMOS 0.35νm and was characterized for sensitivity and color response. The pixel is composed of an n+/psub photodiode, a comparator and a D flip-flop having 16% fill-factor and 30νmx26νm dimensions. The multisampling architecture requires only a 1 bit per pixel memory instead of 8 bits which is typical for time-domain active pixel architectures. The advantage is that the number of transistors in the pixel is low, saving area and providing higher fill-factor. The maximum frame rate is analyzed as a function of number of bits and array size. The analysis shows that it is possible to achieve high frame rates and operation in video mode with 10 bits. Also, we present analysis for the impact of comparator offset voltage in the fixed pattern noise. Copyright 2007 ACM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to describe a new platelet-rich plasma (PRP) protocol with a reduced concentration of leukocytes and intact platelets. We collected 8 mL of venous blood (VB) from marginal ear veins of 10 male New Zealand white rabbits in acid dextrose citrate Vacutainer tubes. Tubes were centrifuged at 302g for 10 minutes. All plasma was collected in plastic tubes to avoid buffy-coat contamination and centrifuged at 2862g for 5 minutes. A 10% calcium chloride activator (10 PRP:2 CaCl2) was added to the lower third of this plasma (PRP), and the PRP gel was obtained. Mean platelet count was 317.7 x 10(3) +/- 39.9/microL in VB and 1344.9 x 10(3) +/- 347.5/microL in PRP. Leukocyte counts were 3.96 x 10(3) +/- 2.01/microL and 0.46 x 10(3) +/- 0.45/microL in VB and PRP, respectively. Mean platelet enrichment was 327.4 +/- 97.8%. All differences were statistically significant (P > .05). This protocol is practical and reproducible, resulting in a high concentration of intact platelets to help tissue repair and low levels of leukocytes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is well known that the microcrack density is a fundamental parameter in hard chromium electroplating. The chemical and mechanical properties of this coating are widely dependent on its microcrack density. In this paper a simple image analysis procedure to determine microcrack density is presented in order to demonstrate it as a fundamental tool to estimate the fatigue, corrosion and wear behavior, as well as the residual stress field of a coated component. For this purpose, the image analysis procedure was carried out on two kinds of hard chromium plating - one called accelerated (high velocity of deposition and fluoride-free) and the other conventional (with fluoride). The coatings were applied on samples of AISI 4340 aeronautical steel, which is widely used in aircraft landing gear components. To characterize the practical significance of this study, the microcrack density results were related to the fatigue, wear and corrosion behavior from previous study and to the residual stress field in the coatings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Incluye Bibliografía

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In recent years studies concerning the applications of lignocellulosic/ inorganic couples have resulted in the development of an interesting class of functional materials. In this work a cellulose/NbOPO 4.nH 2O hybrid using cellulose from surgacane bagasse was prepared and characterized in order to test for adsorption applications. The preparation process was conducted by carrying out metallic niobium dilution in hydrofluoric acid in the presence of nitric acid, then adding boric acid to form the complex and, finally, the cellulose sugar cane bagasse was added. Concentrated phosphoric acid was also inserted to precipitate hydrous niobium phosphate particles in the cellulose fiber. This material was characterized by X-ray diffractometry (XRD), thermogravimetry (TG/DTG), and scanning electronic microscopy (SEM) connected to an energy dispersive spectrophotometer (EDS). Results by SEM/EDS show that NbOPO 4.nH 2O was present in structure of the cellulose. During the preparation of the material, using boric acid it was observed that the formation of precipitate occurred in a shorter time than the material prepared without boric acid.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Maxillomandibular reconstructions are traditionally performed by means of autogenous bone grafts collected from intraoral donor areas and extraoral donor areas such as clavicle, iliac bone, rib, and tibia. The calvarial bone has been studied as an alternative donor area, with a low incidence of complications and minimal postoperative morbidity. Complications such as dural lacerations associated with cerebrospinal fluid leakage and extradural and subdural bleeding were minimized due to the use of surgical trepan, allowing the diploic layer delimitation before the osteotomy, preserving the internal calvarial cortical. The purpose of this article is to suggest a new technique for the obtainment of calvarial bone grafts with surgical trepan.