934 resultados para computed tomographic scan artifact, false positive, facet subluxation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Serum samples from 150 NS1-negative (Platelia ELISA) patients presumptively diagnosed with dengue were analyzed by the TaqMan probed real-time reverse transcription PCR (TaqMan qRT-PCR) method. The qRT-PCR positive samples were tested for serotype by semi-nested RT-PCR and a qualitative immunochromatographic assay for IgG and IgM. Molecular detection methods showed 33 (22%) positive samples out of 150 NS1-antigen negative samples. Of these, 72% were collected up to day 2 after the onset of symptoms, when diagnostic sensitivity of NS1-antigen test assays is significantly enhanced. Most of the cases were not characterized as secondary infection. Twenty-eight samples were successfully serotyped, 75% of which for DENV-4, 14% for DENV-2, 7% for DENV-3 and 4% for DENV-1. These findings reaffirm the hyperendemic situation of the state of Roraima and suggest a lower sensitivity of the NS1 test, mainly when DENV-4 is the predominant serotype. Health care providers should therefore be aware of samples tested negative by NS1 antigen assays, especially when clinical symptoms and other laboratory data results show evidence of dengue infection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ovarian cystic teratoma is a rare cause of autoimmune haemolytic anaemia by warm antibodies, resistant to corticotherapy, with few case reports published in the medical literature. We present a case of a 45-year-old woman admitted to hospital due to general weakness. Laboratory studies revealed macrocytic anaemia, biochemical parameters of haemolysis and peripheral spherocytosis. The direct Coombs test was positive. Viral serologies, anti-nuclear antibodies, anti-double-stranded DNA antibodies and β2-microglobulin were negative. CT scan of the thorax, abdomen and pelvis showed a heterogeneous right anexial lesion. The patient was treated with corticotherapy without improvement of anaemia. Regression of extra-vascular haemolysis and normalisation of haemoglobin was obtained only after laparoscopic splenectomy and right ooforectomy, and the histopathology of the right anexial mass revealed a cystic teratoma. Previously published cases controlled the haemolysis by surgically removing the lesion associated with splenectomy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tese de Doutoramento em Psicologia (Especialidade de Psicologia Experimental e Ciências Cognitivas)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To assess the relation between coronary artery disease and the calcification index on helical computed tomography. METHOD: We studied 22 patients (ages ranging from 40 to 70 years) who underwent coronary angiography because of chest pain suggestive of angina pectoris. Findings on coronary angiography were classified as follows: significant obstructive disease (stenosis > or = 50%), nonobstructive disease (stenosis <50%), and no disease. With no previous knowledge of the results of the coronary angiography and within 7 days, helical computed tomography of the chest was performed. Then, data of the coronary angiography were correlated with the calcification index obtained by helical computed tomography. RESULTS: The sensitivity of helical computed tomography to the presence of significant obstructive lesions on coronary angiography was 87.5%, specificity was 100%, and negative and positive predictive values were 75% and 100%, respectively. The mean calcification index was greater in patients with severe coronary lesions, mainly when involvement of 2 or 3 vessels occurred, than that in patients with no coronary artery disease or with nonobstructive coronary artery lesions (p<0.05). CONCLUSION: Helical computed tomography is an effective method for detecting and quantifying coronary artery calcification, and it has proved to be sensitive to and specific for the noninvasive diagnosis of coronary artery stenosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AbstractBackground:Prone imaging has been demonstrated to minimize diaphragmatic and breast tissue attenuation.Objectives:To determine the role of prone imaging on the reduction of unnecessary rest perfusion studies and coronary angiographies performed, thus decreasing investigation time and radiation exposure.Methods:We examined 139 patients, 120 with an inferior wall and 19 with an anterior wall perfusion defect that might represented attenuation artifact. Post-stress images were acquired in both the supine and prone position. Coronary angiography was used as the “gold standard” for evaluating coronary artery patency. The study was terminated and rest imaging was obviated in the presence of complete improvement of the defect in the prone position. Quantitative interpretation was performed. Results were compared with clinical data and coronary angiographic findings.Results:Prone acquisition correctly revealed defect improvement in 89 patients (89/120) with inferior wall and 12 patients (12/19) with anterior wall attenuation artifact. Quantitative analysis demonstrated statistically significant difference in the mean summed stress scores (SSS) of supine and mean SSS of prone studies in patients with disappearing inferior wall defect in the prone position and patent right coronary artery (true negative results). The mean difference between SSS in supine and in prone position was higher with disappearing than with remaining defects.Conclusion:Technetium-99m (Tc-99m) tetrofosmin myocardial perfusion imaging with the patient in the prone position overcomes soft tissue attenuation; moreover it provides an inexpensive, accurate approach to limit the number of unnecessary rest perfusion studies and coronary angiographies performed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background: Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB). Objective: To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP) by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA) (stenosis ≥ 70%) as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA) and compare the results with those of single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy. Methods: Thirty patients with LBBB who had undergone SPECT for the investigation of coronary artery disease were referred for stress tomography. Independent examiners performed per-patient and per-coronary territory assessments. All patients gave written informed consent to participate in the study that was approved by the institution’s ethics committee. Results: The patients’ mean age was 62 ± 10 years. The mean dose of radiation for the tomography protocol was 9.3 ± 4.6 mSv. With regard to CTP, the per-patient values for sensitivity, specificity, positive and negative predictive values, and accuracy were 86%, 81%, 80%, 87%, and 83%, respectively (p = 0.001). The per-territory values were 63%, 86%, 65%, 84%, and 79%, respectively (p < 0.001). In both analyses, the addition of CTP to CTA achieved higher diagnostic accuracy for detecting myocardial ischemia than SPECT (p < 0.001). Conclusion: The use of the stress tomography protocol is feasible and has good diagnostic accuracy for assessing myocardial ischemia in patients with LBBB.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The purpose of this prospective study was to perform a head-to-head comparison of the two methods most frequently used for evaluation of carotid plaque characteristics: Multi-detector Computed Tomography Angiography (MDCTA) and black-blood 3 T-cardiovascular magnetic resonance (bb-CMR) with respect to their ability to identify symptomatic carotid plaques. METHODS: 22 stroke unit patients with unilateral symptomatic carotid disease and >50% stenosis by duplex ultrasound underwent MDCTA and bb-CMR (TOF, pre- and post-contrast fsT1w-, and fsT2w- sequences) within 15 days of symptom onset. Both symptomatic and contralateral asymptomatic sides were evaluated. By bb-CMR, plaque morphology, composition and prevalence of complicated AHA type VI lesions (AHA-LT6) were evaluated. By MDCTA, plaque type (non-calcified, mixed, calcified), plaque density in HU and presence of ulceration and/or thrombus were evaluated. Sensitivity (SE), specificity (SP), positive and negative predictive value (PPV, NPV) were calculated using a 2-by-2-table. RESULTS: To distinguish between symptomatic and asymptomatic plaques AHA-LT6 was the best CMR variable and presence / absence of plaque ulceration was the best CT variable, resulting in a SE, SP, PPV and NPV of 80%, 80%, 80% and 80% for AHA-LT6 as assessed by bb-CMR and 40%, 95%, 89% and 61% for plaque ulceration as assessed by MDCTA. The combined SE, SP, PPV and NPV of bb-CMR and MDCTA was 85%, 75%, 77% and 83%, respectively. CONCLUSIONS: Bb-CMR is superior to MDCTA at identifying symptomatic carotid plaques, while MDCTA offers high specificity at the cost of low sensitivity. Results were only slightly improved over bb-CMR alone when combining both techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Errors in the inferred multiple sequence alignment may lead to false prediction of positive selection. Recently, methods for detecting unreliable alignment regions were developed and were shown to accurately identify incorrectly aligned regions. While removing unreliable alignment regions is expected to increase the accuracy of positive selection inference, such filtering may also significantly decrease the power of the test, as positively selected regions are fast evolving, and those same regions are often those that are difficult to align. Here, we used realistic simulations that mimic sequence evolution of HIV-1 genes to test the hypothesis that the performance of positive selection inference using codon models can be improved by removing unreliable alignment regions. Our study shows that the benefit of removing unreliable regions exceeds the loss of power due to the removal of some of the true positively selected sites.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract : In the subject of fingerprints, the rise of computers tools made it possible to create powerful automated search algorithms. These algorithms allow, inter alia, to compare a fingermark to a fingerprint database and therefore to establish a link between the mark and a known source. With the growth of the capacities of these systems and of data storage, as well as increasing collaboration between police services on the international level, the size of these databases increases. The current challenge for the field of fingerprint identification consists of the growth of these databases, which makes it possible to find impressions that are very similar but coming from distinct fingers. However and simultaneously, this data and these systems allow a description of the variability between different impressions from a same finger and between impressions from different fingers. This statistical description of the withinand between-finger variabilities computed on the basis of minutiae and their relative positions can then be utilized in a statistical approach to interpretation. The computation of a likelihood ratio, employing simultaneously the comparison between the mark and the print of the case, the within-variability of the suspects' finger and the between-variability of the mark with respect to a database, can then be based on representative data. Thus, these data allow an evaluation which may be more detailed than that obtained by the application of rules established long before the advent of these large databases or by the specialists experience. The goal of the present thesis is to evaluate likelihood ratios, computed based on the scores of an automated fingerprint identification system when the source of the tested and compared marks is known. These ratios must support the hypothesis which it is known to be true. Moreover, they should support this hypothesis more and more strongly with the addition of information in the form of additional minutiae. For the modeling of within- and between-variability, the necessary data were defined, and acquired for one finger of a first donor, and two fingers of a second donor. The database used for between-variability includes approximately 600000 inked prints. The minimal number of observations necessary for a robust estimation was determined for the two distributions used. Factors which influence these distributions were also analyzed: the number of minutiae included in the configuration and the configuration as such for both distributions, as well as the finger number and the general pattern for between-variability, and the orientation of the minutiae for within-variability. In the present study, the only factor for which no influence has been shown is the orientation of minutiae The results show that the likelihood ratios resulting from the use of the scores of an AFIS can be used for evaluation. Relatively low rates of likelihood ratios supporting the hypothesis known to be false have been obtained. The maximum rate of likelihood ratios supporting the hypothesis that the two impressions were left by the same finger when the impressions came from different fingers obtained is of 5.2 %, for a configuration of 6 minutiae. When a 7th then an 8th minutia are added, this rate lowers to 3.2 %, then to 0.8 %. In parallel, for these same configurations, the likelihood ratios obtained are on average of the order of 100,1000, and 10000 for 6,7 and 8 minutiae when the two impressions come from the same finger. These likelihood ratios can therefore be an important aid for decision making. Both positive evolutions linked to the addition of minutiae (a drop in the rates of likelihood ratios which can lead to an erroneous decision and an increase in the value of the likelihood ratio) were observed in a systematic way within the framework of the study. Approximations based on 3 scores for within-variability and on 10 scores for between-variability were found, and showed satisfactory results. Résumé : Dans le domaine des empreintes digitales, l'essor des outils informatisés a permis de créer de puissants algorithmes de recherche automatique. Ces algorithmes permettent, entre autres, de comparer une trace à une banque de données d'empreintes digitales de source connue. Ainsi, le lien entre la trace et l'une de ces sources peut être établi. Avec la croissance des capacités de ces systèmes, des potentiels de stockage de données, ainsi qu'avec une collaboration accrue au niveau international entre les services de police, la taille des banques de données augmente. Le défi actuel pour le domaine de l'identification par empreintes digitales consiste en la croissance de ces banques de données, qui peut permettre de trouver des impressions très similaires mais provenant de doigts distincts. Toutefois et simultanément, ces données et ces systèmes permettent une description des variabilités entre différentes appositions d'un même doigt, et entre les appositions de différents doigts, basées sur des larges quantités de données. Cette description statistique de l'intra- et de l'intervariabilité calculée à partir des minuties et de leurs positions relatives va s'insérer dans une approche d'interprétation probabiliste. Le calcul d'un rapport de vraisemblance, qui fait intervenir simultanément la comparaison entre la trace et l'empreinte du cas, ainsi que l'intravariabilité du doigt du suspect et l'intervariabilité de la trace par rapport à une banque de données, peut alors se baser sur des jeux de données représentatifs. Ainsi, ces données permettent d'aboutir à une évaluation beaucoup plus fine que celle obtenue par l'application de règles établies bien avant l'avènement de ces grandes banques ou par la seule expérience du spécialiste. L'objectif de la présente thèse est d'évaluer des rapports de vraisemblance calcul és à partir des scores d'un système automatique lorsqu'on connaît la source des traces testées et comparées. Ces rapports doivent soutenir l'hypothèse dont il est connu qu'elle est vraie. De plus, ils devraient soutenir de plus en plus fortement cette hypothèse avec l'ajout d'information sous la forme de minuties additionnelles. Pour la modélisation de l'intra- et l'intervariabilité, les données nécessaires ont été définies, et acquises pour un doigt d'un premier donneur, et deux doigts d'un second donneur. La banque de données utilisée pour l'intervariabilité inclut environ 600000 empreintes encrées. Le nombre minimal d'observations nécessaire pour une estimation robuste a été déterminé pour les deux distributions utilisées. Des facteurs qui influencent ces distributions ont, par la suite, été analysés: le nombre de minuties inclus dans la configuration et la configuration en tant que telle pour les deux distributions, ainsi que le numéro du doigt et le dessin général pour l'intervariabilité, et la orientation des minuties pour l'intravariabilité. Parmi tous ces facteurs, l'orientation des minuties est le seul dont une influence n'a pas été démontrée dans la présente étude. Les résultats montrent que les rapports de vraisemblance issus de l'utilisation des scores de l'AFIS peuvent être utilisés à des fins évaluatifs. Des taux de rapports de vraisemblance relativement bas soutiennent l'hypothèse que l'on sait fausse. Le taux maximal de rapports de vraisemblance soutenant l'hypothèse que les deux impressions aient été laissées par le même doigt alors qu'en réalité les impressions viennent de doigts différents obtenu est de 5.2%, pour une configuration de 6 minuties. Lorsqu'une 7ème puis une 8ème minutie sont ajoutées, ce taux baisse d'abord à 3.2%, puis à 0.8%. Parallèlement, pour ces mêmes configurations, les rapports de vraisemblance sont en moyenne de l'ordre de 100, 1000, et 10000 pour 6, 7 et 8 minuties lorsque les deux impressions proviennent du même doigt. Ces rapports de vraisemblance peuvent donc apporter un soutien important à la prise de décision. Les deux évolutions positives liées à l'ajout de minuties (baisse des taux qui peuvent amener à une décision erronée et augmentation de la valeur du rapport de vraisemblance) ont été observées de façon systématique dans le cadre de l'étude. Des approximations basées sur 3 scores pour l'intravariabilité et sur 10 scores pour l'intervariabilité ont été trouvées, et ont montré des résultats satisfaisants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The application of two approaches for high-throughput, high-resolution X-ray phase contrast tomographic imaging being used at the tomographic microscopy and coherent radiology experiments (TOMCAT) beamline of the SLS is discussed and illustrated. Differential phase contrast (DPC) imaging, using a grating interferometer and a phase-stepping technique, is integrated into the beamline environment at TOMCAT in terms of the fast acquisition and reconstruction of data and the availability to scan samples within an aqueous environment. A second phase contrast method is a modified transfer of intensity approach that can yield the 3D distribution of the decrement of the refractive index of a weakly absorbing object from a single tomographic dataset. The two methods are complementary to one another: the DPC method is characterised by a higher sensitivity and by moderate resolution with larger samples; the modified transfer of intensity approach is particularly suited for small specimens when high resolution (around 1 mu m) is required. Both are being applied to investigations in the biological and materials science fields.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECT Monoenergetic imaging with dual-energy CT has been proposed to reduce metallic artifacts in comparison with conventional polychromatic CT. The purpose of this study is to systematically evaluate and define the optimal dual-energy CT imaging parameters for specific cervical spinal implant alloy compositions. METHODS Spinal fixation rods of cobalt-chromium or titanium alloy inserted into the cervical spine section of an Alderson Rando anthropomorphic phantom were imaged ex vivo with fast-kilovoltage switching CT at 80 and 140 peak kV. The collimation width and field of view were varied between 20 and 40 mm and medium to large, respectively. Extrapolated monoenergetic images were generated at 70, 90, 110, and 130 kiloelectron volts (keV). The standard deviation of voxel intensities along a circular line profile around the spine was used as an index of the magnitude of metallic artifact. RESULTS The metallic artifact was more conspicuous around the fixation rods made of cobalt-chromium than those of titanium alloy. The magnitude of metallic artifact seen with titanium fixation rods was minimized at monoenergies of 90 keV and higher, using a collimation width of 20 mm and large field of view. The magnitude of metallic artifact with cobalt-chromium fixation rods was minimized at monoenergies of 110 keV and higher; collimation width or field of view had no effect. CONCLUSIONS Optimization of acquisition settings used with monoenergetic CT studies might yield reduced metallic artifacts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although a metastatic presentation of an occult prostatic adenocarcinoma is not uncommon, the majority of these patients present with bone metastasis affecting the axial skeleton. Cranial metastases to the paranasal sinuses are extremely rare. A 56-year-old man presented with loss of vision and numbness of the right side of the face. Computed tomography (CT) scan and cranial magnetic resonance imaging (MRI) revealed a mass invading the sphenoid sinus. The patient underwent surgery to remove the lesion, and the histopathological examination suggested metastasis of an adenocarcinoma, with positive staining to prostatic specific antigen (PSA). However, serum PSA was 4 ng/mL, and the patient did not report any lower urinary tract symptoms or bone pain. Transrectal ultrasound-guided biopsy revealed prostatic adenocarcinomas with a Gleason score of 8 [4 + 4]. The subsequent treatment consisted of radiotherapy and androgen deprivation, followed by first- and second-line chemotherapy (docetaxel and cabazitaxel) when the disease progressed. The patient achieved a good response with the last cycle of cabazitaxel and after a 5-year followup is currently alive. Cranial metastases of prostate adenocarcinoma are rare, and there is currently no standard treatment for these patients. Whenever possible, surgery combined with radiotherapy and hormonotherapy is the recommended option.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims To compare multidetector computed tomography (MDCT) with intravascular ultrasound (IVUS) and invasive quantitative coronary angiography (QCA) for assessment of coronary lesions in patients referred for suspected coronary artery disease (CAD). Methods and results We studied 57 patients (48 men; mean age: 63 +/- 10 years) who underwent 64-slice MDCT because of atypical chest pain, stable angina, or ECG abnormalities and were diagnosed with CAD. All patients subsequently underwent QCA and IVUS. We analyzed 102 coronary lesions using the three techniques. Measurements of luminal area stenosis and cross-sectional area by MDCT (72.9 +/- 7.0% and 4.5 +/- 1.8 mm(2), respectively) were in good agreement with those by IVUS [72.7 +/- 6.7% and 4.5 +/- 1.6 mm(2), respectively; Lin's concordance correlation coefficient r = 0.847; 95% confidence interval (CI) = 0.792-0.902 and r = 0.931; 95% CI = 0.906-0.956, respectively] but not QCA (r = 0.115; 95% CI = 0.040-0.189 and r = 0.433; 95% CI = 0.291-0.576, respectively). Plaque cross-sectional area and plaque volume measured by MDCT (12.4 +/- 3.8 mm(2) and 104.7 +/- 52.8 mu l, respectively) were in good agreement with those by IVUS (12.2 +/- 3.7 mm(2) and 102.8 +/- 54.1 mu l; r = 0.913; 95% CI = 0.880-0.945 and r = 0.979; 95% CI = 0.969-0.990, respectively). Remodeling index measurements by MDCT (1.22 +/- 0.22) were in good agreement with those by IVUS (r = 0.876; 95% CI = 0.831-0.922). Positive remodeling occurred in 63% of stenoses. Conclusion MDCT allows accurate noninvasive assessment of coronary stenosis, plaque burden and remodeling in patients referred for suspected CAD. Positive remodeling is a frequent finding in stable lesions. J Cardiovasc Med 12:122-130 (C) 2011 Italian Federation of Cardiology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hypersensitivity pneumonitis (HP) is an immunologically mediated lung disease due to the repetitive inhalation of antigens. Most new cases arise from residential exposures, notably to birds, and are thus more difficult to recognise. The present authors report a 59-yr-old male who complained of dyspnoea and cough while being treated with amiodarone. Pulmonary function tests revealed restriction and obstruction with low diffusing lung capacity for carbon monoxide and partial pressure of oxygen. A high-resolution computed tomography chest scan and bronchoalveolar lavage showed diffuse bilateral ground-glass attenuation and lymphocytic alveolitis, respectively. Initial diagnosis was amiodarone pulmonary toxicity, but because of a rapidly favourable evolution, this diagnosis was questioned. A careful environmental history revealed a close contact with lovebirds shortly before the onset of symptoms. Precipitins were strongly positive against lovebird droppings, but were negative against other avian antigens. The patient was diagnosed with hypersensitivity pneumonitis to lovebirds. Avoidance of lovebirds and steroid treatment led to rapid improvement. The present observation identifies a new causative agent for hypersensitivity pneumonitis and highlights the importance of a thorough environmental history and of searching for precipitins against antigens directly extracted from the patient's environment. These two procedures should allow a more precise classification of some cases of pneumonitis, and thus might avoid progression of active undiagnosed hypersensitivity pneumonitis to irreversible fibrosis or emphysema.