930 resultados para Humeral supracondylar fractures


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spinal involvement is a common presentation of multiple myeloma (MM); however, the cervical spine is the least common site of myelomatous involvement. Few studies evaluate the results of percutaneous vertebroplasty (PV) in the treatment of MM of the spine. The purpose of this series is to report on the use of PV in the treatment of MM of the cervical spine and to review the literature. From January 1994 to October 2007, four patients (three men and one woman; mean age, 45 years) who underwent five PV for painful MM in the cervical spine were retrospectively reviewed. The pain was estimated by the patient on a verbal analogic scale. Clinical follow-up was available for all patients (mean, 27.5 months; range, 1-96 months). The mean volume of cement injected per vertebral body was 2.3 +/- 0.8 mL (range, 1.0-4.0 mL) with a mean vertebral filling of 55.0 +/- 12.0% (range, 40.0-75.0%). Analgesic efficacy was achieved in all patients. One patient had a spinal instability due to a progression of spinal deformity noted on follow-up radiographs, without clinical symptoms. Cement leakage was detected in three (60%) of the five treated vertebrae. There was no clinical complication. The present series suggests that PV for MM of the cervical spine is safe and effective for pain control; nonetheless, the detrimental impact of the disease on bone quality should prompt close radiological follow-up after PV owing to the risk of spinal instability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: We studied the angiographic findings in patients with small epidural hematomas and cranial fractures crossing over the trajectory of the middle meningeal artery and its branches. Additionally, the Occurrence of traumatic vascular lesions and their clinical relevance and treatment are discussed. METHODS: A consecutive analysis was performed for 24 patients who harbored small epidural hematomas in middle meningeal artery topography associated with cranial fractures. Computed tomographic scans and plain x-ray studies were used to diagnose linear cranial fractures. Patients with large epidural hematomas or associated traumatic lesions were excluded from the study. Selective ipsilateral external carotid angiograms were obtained, and an endovascular procedure was performed if any vascular injury was evidenced. RESULTS: In all patients with cranial fractures crossing over the middle meningeal artery and its branches, some kind of vascular lesion was seen. Two types of findings were noted: active extravasation of the contrast medium (71%) and pseudoaneurysms (29%). Early filling of diploic vessels was found in 8.3% of fractures concomitantly with active extravasation. Embolization was performed in all patients. No additional enlargement of the epidural hematoma was observed, and the postoperative period was uneventful. CONCLUSION: This study shows that pseudoaneurysms and active extravasation of contrast are common findings in this subset of patients. Although the natural history of these lesions is still poorly understood, additional investigation with ipsilateral external carotid angiography may be recommended, considering the potentially catastrophic consequences of late rupture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ultrasonometry seems to have a future for the evaluation of fracture healing. Ultrasound propagation velocity (USPV) significantly decreases at the same time that bone diameter decreases as healing takes place, thus approaching normal values. In this investigation, both USPV and broadband ultrasound attenuation (BUA) were measured using a model of a transverse mid-diaphyseal osteotomy of sheep tibiae. Twenty-one sheep were operated and divided into three groups of seven, according to the follow-up period of 30, 60, and 90 days, respectively. The progress of healing of the osteotomy was checked with monthly conventional radiographs. The animals were killed at the end of the period of observation of each group, both operated-upon and intact tibiae being resected and submitted to the measurement of underwater transverse and direct contact transverse and longitudinal USPV and BUA at the osteotomy site. The intact left tibia of the 21 animals was used for control, being examined on a symmetrical diaphyseal segment. USPV increased while BUA decreased with the progression of healing, with significant differences between the operated and untouched tibiae and between the periods of observation, for most of the comparisons. There was a strong negative correlation between USPV and BUA. Both USPV and BUA directly reflect and can help predict the healing of fractures, but USPV alone can be used as a fundamental parameter. Ultrasonometry may be of use in clinical application to humans provided adequate adaptations can be developed. (C) 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 29:444-451, 2011

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To determine the elution characteristics of the antibiotic (gentamicin) mixed with bone cement. Methods: 480mg of gentamicin was added to 40g of bone cement. Ten specimens were immersed in buffered saline solution for 28 days. Samples of days 1, 2, 7, 14, 21 and 28 were analyzed by the fluorescence polarization immunoassay method, Results: Most of the gentamicin was eluted from the cement in the first 24 hours. A gradual downslide occurred between days 2 and 14. By the 28th day, there was no trace of the antibiotic. Conclusion: The mixture released high amounts of the antibiotic in a predictable (therapeutic) manner during at least fourteen days.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The physiological role of parathormone (PTH) in the maintenance of bone mass in humans has not been fully defined. The main objective of the present study was to evaluate basal and EDTA-stimulated PTH levels in Young women (Group Y = 30.9 years, N = 7) and in women in late menopause (Group M = 64.7 years, N = 7) and their relationship to bone mineral density. Methods: The PTH secretion test was performed by induction of hypocalcemia through intravenous administration of EDTA for 2 h. Blood samples were collected every 10 min and used for ionic calcium and PTH measurements. During the basal period, an additional sample was collected for the determination of osteocalcin, FSH, and estradiol. A sample of early morning second voided urine was collected for analysis of deoxypiridinoline and creatinine Lis well as bone mass density (BMD) was determined by dual X-ray energy absorptiometry (DEXA). Results: The aged patients presented lower femoral BMD (Y = 0.860 g/cm(2) vs. M = 0.690 g/cm(2), P < 0.01), With four of them having a T score lower than - 2.5 S.D. Basal, and during the EDTA infusion, PTH values were similar in both groups. However, among aged volunteers, the rise in PTH levels was higher for subjects with normal bone mass (NM: peak = 236 pg/ml) than for subjects with osteoporosis (OM: peak = 134.4 pg/ml). Conclusions: The present results suggest that PTH can have a modulating effect on the rate of bone loss during late menopause. (c) 2007 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study is to characterize the structure of the beak of Toco Toucan (Ramphastos toco) and to investigate means for arresting fractures in the rhinotheca using acrylic resin. The structure of the rhamphastid bill has been described as a sandwich structured composite having a thin exterior comprised of keratin and a thick foam core constructed of mineralized collagenous rods (trabeculae). The keratinous rhamphotheca consists of superposed polygonal scales (approximately 50 pm in diameter and 1 mu m in thickness). In order to simulate the orientation of loading to which the beak is subjected during exertion of bite force, for example, we conducted flexure tests on the dorso-ventral axis of the maxilla. The initially intact (without induced fracture) beak fractured in the central portion when subjected to a force of 270 N, at a displacement of 23 mm. The location of this fracture served as a reference for the fractures induced in other beaks tested. The second beak was fractured and repaired by applying resin on both lateral surfaces. The repaired maxilla sustained a force of 70 N with 6.5 mm deflection. The third maxilla was repaired similarly except that it was conditioned in acid for 60s prior to fixation with resin. It resisted a force of up to 63 N at 6 mm of deflection. The experimental results were compared with finite element calculations for unfractured beak in bending configuration. The repaired specimens were found to have strength equal to only one third of the intact beak. Finite element simulations allow visualization of how the beak system (sandwich shell and cellular core) sustains high flexural strength. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives To compare the biomechanical characteristics of 2 arthrodesis techniques for the equine proximal interphalangeal joint (PIP) using either a 3-hole 4.5 mm locking compression plate (LCP) or 3-hole 4.5 mm narrow dynamic compression plate (DCP), both with 2 transarticular 5.5 mm cortex screws. Study Design Experimental. Sample Population Cadaveric adult equine forelimbs (*n=6 pairs). Methods For each forelimb pair, 1 limb was randomly assigned to 1 of 2 treatment groups and the contralateral limb by default to the other treatment group. Construct stiffness, gap formation across the PIP joint, and rotation about the PIP joint were determined for each construct before cyclic axial loading and after each of four, 5000 cycle loading regimens. After the 20,000 cycle axial loading regimen, each construct was loaded to failure. Results There were no significant differences in construct stiffness, gap formation, or sagittal plane rotation between the LCP and DCP treatment groups at any of the measured time points. Conclusion Biomechanically, fixation of the equine PIP joint with a 3-hole 4.5 mm LCP is equivalent to fixation with a 3-hole 4.5 mm narrow DCP under the test conditions used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to develop a plate to treat fractures of the mandibular body in dogs and to validate the project using finite elements and biomechanical essays. Mandible prototypes were produced with 10 oblique ventrorostral fractures (favorable) and 10 oblique ventrocaudal fractures (unfavorable). Three groups were established for each fracture type. Osteosynthesis with a pure titanium plate of double-arch geometry and blocked monocortical screws offree angulanon were used. The mechanical resistance of the prototype with unfavorable fracture was lower than that of the fcworable fracture. In both fractures, the deflection increased and the relative stiffness decreased proportionally to the diminishing screw number The finite element analysis validated this plate study, since the maximum tension concentration observed on the plate was lower than the resistance limit tension admitted by the titanium. In conclusion, the double-arch geometry plate fixed with blocked monocortical screws has sufficient resistance to stabilize oblique,fractures, without compromising mandibular dental or neurovascular structures. J Vet Dent 24 (7); 212 - 221, 2010

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Causes of dental infections can be related to failed dental eruption, malocclusion, abrasion, fractures with or without exposure of the dental pulp, and periodontal disease. Reports of oral myiasis in megavertebrates in captivity air infrequent, perhaps due to the difficulty in observing the oral cavity in such species. This report describes a case of oral myiasis in an adult male hippopotamus in the gingival area and alveolar mucosa of the left mandibular canine tooth. J Vet Dent 26 (3); 168 170,2009

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: This study evaluated the healing of mandibular condylar fracture in rats submitted to experimental and protein undernutrition (8% of protein) by means of histological analysis. Material: Forty-five adult Wistar rats were divided into three groups of 15 animals: a fracture group, who were submitted to condylar fracture with no changes in diet; an undernourished fracture group, who were submitted to a low protein diet and condylar fracture: an undernourished group, kept until the end of experiment, without condylar fracture. Displaced fractures of the right condyle were created under general anaesthesia. The histological study comprised fracture site and temporomandibular joint evaluations. Results: The undernourished fracture group showed significant weight loss. There was a marked decrease in the values of serum proteins and albumin in the undernourished fracture group. Histological analysis showed that protein undernutrition lead to atrophy of the condylar fibrocartilage. Fractures in undernutrition presented a delay in callus formation due to more extensive devitalized bone areas, and after 3 months there were still bone formation areas, while fibrous ankylosis occurred in the articular space. Conclusion: It was concluded that mandibular condyle fractures in rats with protein undernutrition had impaired callus formation, as well as fibrous ankylosis into the temporomandibular joint. (C) 2010 European Association for Cranio-Maxillo-Facial Surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this in vitro study was to compare the bond strength between fiber post and laser-treated root canals. Forty single-rooted bovine teeth were endodontically treated and randomly divided into four groups of equal size according to the root canal treatment: group 1 conventional treatment (without laser irradiation); group 2 Nd:YAG laser (1.5 W, 10 Hz, 100 mJ); group 3 Er,Cr:YSGG laser (0.75 W, 20 Hz); and group 4 Nd:YAG + Er,Cr:YSGG lasers. The fiber posts were cemented with an adhesive system + resin cement, in accordance with the manufacturer`s instructions. A mini acrylic pipe was fixed on the coronal section of the post using a light-polymerized resin. Specimens were mounted on an acrylic pipe with a self-polymerized resin. Retention forces were determined using a universal testing machine (0.5 mm/min). Data were analyzed using one-way ANOVA and Tukey tests (p < 0.05). The post retention force in group 2 was found to be lower than that in the other experimental groups. Fractures were observed at the interface between the dentin and the resin in all groups. High-intensity lasers can be used in conventional endodontic treatment; however, root canal surface irradiation using the Nd:YAG laser was shown to negatively affect the post retention force.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to assess the influence of adhesive area delimitation on the microshear bond strength of different adhesives to dentin. Materials and Methods: Eighteen bovine incisors were sectioned and the exposed dentin surfaces were prepared with 600-grit SIC paper. These teeth were randomly divided into three groups, according to the adhesive to be applied: two-step etch-and-rinse Adper Single Bond 2 (3M ESPE), two-step self-etching Clearfil SE Bond (Kuraray), and one-step Clearfil S(3) Bond (Kuraray). On each dentin surface, 4 samples were built up with the composite resin Z100 (3M ESPE); on 2 of these, a suggested area delimitation technique was employed. After 24 h of storage in water at 37 degrees C, samples were subjected to the microshear bond strength test, and the failure modes were evaluated under optical and scanning electron microscopes. The obtained results were statistical analyzed using two-way ANOVA and Tukey`s test. Results: Groups without area delimitation presented significantly higher bond strength results (p < 0.05) and a higher incidence of cohesive failures. In these groups, fractures tended to occur beyond the limits of the actual adhesive area, while the area restriction technique succeeded in avoiding this phenomenon. The three adhesives performed similarly when area delimitation was employed (p > 0.05), but Clearfil S(3) Bond showed significantly higher bond strength results when no area delimitation was taken into account (p < 0.05). Conclusion: The extension of the adhesive area beyond the limits of the composite cylinder may play an important role in the results of microshear bond strength tests, while the suggested area delimitation technique may lead to less questionable outcomes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The aim of the present study was to test the accuracy of small-volume cone-beam computed tomography (CBCT) scanning in the detection of horizontal root fractures and to assess the influence of a metallic post. Methods: Forty teeth were divided into four groups based on the presence of metallic posts and horizontal root fracture. The teeth were examined by small-volume CBCT scanning at 0.2-mm voxel resolution. Three observers analyzed the samples for the presence of a horizontal root fracture. Sensitivity and specificity were calculated. Results: High values for accuracy (73%-88%) were obtained in the groups without a metallic post, and statistically significant differences were found when the group with a metallic post has been observed (55%-70%). Intraobserver agreement also showed statistically significant differences in the groups with a metallic post. Conclusions: Small-volume CBCT scanning showed high accuracy in detecting horizontal root fracture without a metallic post. However, the presence of a metallic post significantly reduced the specificity and sensitivity of this examination. (J Endod 2011;37:1456-1459)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To evaluate the effect of framework design on the fatigue life and failure modes of metal ceramic (MC, Ni-Cr alloy core, VMK 95 porcelain veneer), glass-infiltrated alumina (ICA, In-Ceram Alumina/VM7), and veneered yttria-stabilized tetragonal zirconia polycrystals (Y-TZP, IPSe.max ZirCAD/IPS e.max,) crowns. Methods: Sixty composite resin tooth replicas of a prepared maxillary first molar were produced to receive crowns systems of a standard (MCs, ICAs, and Y-TZPs, n = 10 each) or a modified framework design (MCm, ICAm, and Y-TZPm, n = 10 each). Fatigue loading was delivered with a spherical steel indenter (3.18 mm radius) on the center of the occlusal surface using r-ratio fatigue (30-300 N) until completion of 10(6) cycles or failure. Fatigue was interrupted every 125,000 cycles for damage evaluation. Weibull distribution fits and contour plots were used for examining differences between groups. Failure mode was evaluated by light polarized and SEM microscopy. Results: Weibull analysis showed the highest fatigue life for MC crowns regardless of framework design. No significant difference (confidence bound overlaps) was observed between ICA and Y-TZP with or without framework design modification. Y-TZPm crowns presented fatigue life in the range of MC crowns. No porcelain veneer fracture was observed in the MC groups, whereas ICAs presented bulk fracture and ICAm failed mainly through the veneer. Y-TZP crowns failed through chipping within the veneer, without core fractures. Conclusions: Framework design modification did not improve the fatigue life of the crown systems investigated. Y-TZPm crowns showed comparable fatigue life to MC groups. Failure mode varied according to crown system. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To test the strength to failure and fracture mode of three indirect composite materials directly applied onto Ti-6Al-4V implant abutments vs cemented standard porcelain-fused-to-metal (PFM) crowns. Materials and Methods: Sixty-four locking taper abutments were randomly allocated to four groups and were cleaned in ethanol in an ultrasonic bath for 5 min. After drying under ambient conditions, the abutments were grit blasted and a custom 4-cusp molar crown mold was utilized to produce identical crowns (n = 16 per group) of Tescera (Bisco), Ceramage (Shofu), and Diamond Crown (DRM) according to the manufacturer`s instructions. The porcelain-fused-to-metal crowns were fabricated by conventional means involving the construction and a wax pattern and casting of a metallic coping followed by sintering of increasing layers of porcelain. All crowns were loaded to failure by an indenter placed at one of the cusp tips at a 1 mm/min rate. Subsequently, fracture analysis was performed by means of stereomicroscopy and scanning electron microscopy. One-way ANOVA at 95% level of significance was utilized for statistical analysis. Results: The single load to failure (+/- SD) results were: Tescera (1130 +/- 239 N), Ceramage (1099 +/- 257 N), Diamond Crown (1155 +/- 284 N), and PFM (1081 +/- 243 N). Stereomicroscopy analysis showed two distinct failure modes, where the loaded cusp failed either with or without abutment/metallic coping exposure. SEM analysis of the fractures showed multiple crack propagation towards the cervical region of the crown below a region of plastic deformation at the indenter contact region. Conclusion: The three indirect composites and PFM systems fractured at loads higher than those typically associated with normal occlusal function. Although each material had a different composition and handling technique, no significant differences were found concerning their single load to fracture resistance among composite systems and PFM.