Resumo

Introduction: The aim of the present study was to test the accuracy of small-volume cone-beam computed tomography (CBCT) scanning in the detection of horizontal root fractures and to assess the influence of a metallic post. Methods: Forty teeth were divided into four groups based on the presence of metallic posts and horizontal root fracture. The teeth were examined by small-volume CBCT scanning at 0.2-mm voxel resolution. Three observers analyzed the samples for the presence of a horizontal root fracture. Sensitivity and specificity were calculated. Results: High values for accuracy (73%-88%) were obtained in the groups without a metallic post, and statistically significant differences were found when the group with a metallic post has been observed (55%-70%). Intraobserver agreement also showed statistically significant differences in the groups with a metallic post. Conclusions: Small-volume CBCT scanning showed high accuracy in detecting horizontal root fracture without a metallic post. However, the presence of a metallic post significantly reduced the specificity and sensitivity of this examination. (J Endod 2011;37:1456-1459)

Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq) National Council for Research[303847/2009-3]

Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES)

Master Degree Scholarship

[472895/2009-5]

Identificador

JOURNAL OF ENDODONTICS, v.37, n.10, p.1456-1459, 2011

0099-2399

http://producao.usp.br/handle/BDPI/25643

10.1016/j.joen.2011.05.040

http://dx.doi.org/10.1016/j.joen.2011.05.040

Idioma(s)

eng

Publicador

ELSEVIER SCIENCE INC

Relação

Journal of Endodontics

Direitos

restrictedAccess

Copyright ELSEVIER SCIENCE INC

Palavras-Chave #Cone-beam computed tomography scanning #diagnosis #horizontal root fracture #IN-VITRO #1ST MOLARS #RADIOGRAPHY #ACCURACY #DENSITY #TOOTH #CT #Dentistry, Oral Surgery & Medicine
Tipo

article

original article

publishedVersion