942 resultados para Matching to sample


Relevância:

30.00% 30.00%

Publicador:

Resumo:

An analytical procedure based on microwave-assisted digestion with diluted acid and a double cloud point extraction is proposed for nickel determination in plant materials by flame atomic absorption spectrometry. Extraction in micellar medium was successfully applied for sample clean up, aiming to remove organic species containing phosphorous that caused spectral interferences by structured background attributed to the formation of PO species in the flame. Cloud point extraction of nickel complexes formed with 1,2-thiazolylazo-2-naphthol was explored for pre-concentration, with enrichment factor estimated as 30, detection limit of 5 mu g L(-1) (99.7% confidence level) and linear response up to 80 mu g L(-1). The accuracy of the procedure was evaluated by nickel determinations in reference materials and the results agreed with the certified values at the 95% confidence level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For environmental quality assessment, INAA has been applied for determining chemical elements in small (200 mg) and large (200 g) samples of leaves from 200 trees. By applying the Ingamells` constant, the expected percent standard deviation was estimated in 0.9-2.2% for 200 mg samples. Otherwise, for composite samples (200 g), expected standard deviation varied from 0.5 to 10% in spite of analytical uncertainties ranging from 2 to 30%. Results thereby suggested the expression of the degree of representativeness as a source of uncertainty, contributing for increasing of the reliability of environmental studies mainly in the case of composite samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The formation of the Mn(III)/EDTA complex in a flow system with solenoid micro-pumps was exploited for fast manganese determination in freshwater. Manganese(II) was oxidized in a solid-phase reactor containing lead dioxide immobilized on polyester. Long pathlength spectrophotometry was exploited to increase sensitivity, aiming to reach the threshold limit established by environmental legislation. A linear response was observed from 25 to 1500 mu g L(-1), with a detection limit of 6 mu g L(-1) (99.7% confidence level). Sample throughput and coefficient of variation were 36 samples/h and 2.6% (n = 10), respectively. EDTA consumption and waste generation were estimated as 500 mu g and 3 mL per determination, respectively. The amount of Pb in the residue corresponds to 250 mu g per determination and a solid-phase reactor could be used for up to 1600 determinations. Adsorption in active charcoal avoided interferences caused by organic matter and the developed procedure was successfully applied for determination of manganese in freshwater samples. Results were in agreement with those attained by GFAAS at the 95% confidence level. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Soils are an important component in the biogeochemical cycle of carbon, storing about four times more carbon than biomass plants and nearly three times more than the atmosphere. Moreover, the carbon content is directly related on the capacity of water retention, fertility. among other properties. Thus, soil carbon quantification in field conditions is an important challenge related to carbon cycle and global climatic changes. Nowadays. Laser Induced Breakdown Spectroscopy (LIBS) can be used for qualitative elemental analyses without previous treatment of samples and the results are obtained quickly. New optical technologies made possible the portable LIBS systems and now, the great expectation is the development of methods that make possible quantitative measurements with LIBS. The goal of this work is to calibrate a portable LIBS system to carry out quantitative measures of carbon in whole tropical soil sample. For this, six samples from the Brazilian Cerrado region (Argisoil) were used. Tropical soils have large amounts of iron in their compositions, so the carbon line at 247.86 nm presents strong interference of this element (iron lines at 247.86 and 247.95). For this reason, in this work the carbon line at 193.03 nm was used. Using methods of statistical analysis as a simple linear regression, multivariate linear regression and cross-validation were possible to obtain correlation coefficients higher than 0.91. These results show the great potential of using portable LIBS systems for quantitative carbon measurements in tropical soils. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel flow-based strategy for implementing simultaneous determinations of different chemical species reacting with the same reagent(s) at different rates is proposed and applied to the spectrophotometric catalytic determination of iron and vanadium in Fe-V alloys. The method relies on the influence of Fe(II) and V(IV) on the rate of the iodide oxidation by Cr(VI) under acidic conditions, the Jones reducing agent is then needed Three different plugs of the sample are sequentially inserted into an acidic KI reagent carrier stream, and a confluent Cr(VI) solution is added downstream Overlap between the inserted plugs leads to a complex sample zone with several regions of maximal and minimal absorbance values. Measurements performed on these regions reveal the different degrees of reaction development and tend to be more precise Data are treated by multivariate calibration involving the PLS algorithm The proposed system is very simple and rugged Two latent variables carried out ca 95% of the analytical information and the results are in agreement with ICP-OES. (C) 2010 Elsevier B V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The quality of environmental studies depends on the utilization of adequate sampling protocol and analytical method for obtaining reliable results and minimizing analytical uncertainties. In order to demonstrate the applicability of INAA for determining chemical element composition of invertebrates, this work evaluated sample representativeness in terms of subsampling and sample size. Br, Co, Fe, K, Na, Sc and Zn could be determined in very small samples despite increasing of analytical uncertainties. Special attention should be directed to invertebrate species with small structures because of the high chemical variation observed among different sample sizes tested.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Although the Clock Drawing Test (CDT) is the second most used test in the world for the screening of dementia, there is still debate over its sensitivity specificity, application and interpretation in dementia diagnosis. This study has three main aims: to evaluate the sensitivity and specificity of the CDT in a sample composed of older adults with Alzheimer`s disease (AD) and normal controls; to compare CDT accuracy to the that of the Mini-mental State Examination (MMSE) and the Cambridge Cognitive Examination (CAMCOG), and to test whether the association of the MMSE with the CDT leads to higher or comparable accuracy as that reported for the CAMCOG. Methods: Cross-sectional assessment was carried out for 121 AD and 99 elderly controls with heterogeneous educational levels from a geriatric outpatient clinic who completed the Cambridge Examination for Mental Disorder of the Elderly (CAMDEX). The CDT was evaluated according to the Shulman, Mendez and Sunderland scales. Results: The CDT showed high sensitivity and specificity. There were significant correlations between the CDT and the MMSE (0.700-0.730; p < 0.001) and between the CDT and the CAMCOG (0.753-0.779; p < 0.001). The combination of the CDT with the MMSE improved sensitivity and specificity (SE = 89.2-90%; SP = 71.7-79.8%). Subgroup analysis indicated that for elderly people with lower education, sensitivity and specificity were both adequate and high. Conclusions: The CDT is a robust screening test when compared with the MMSE or the CAMCOG, independent of the scale used for its interpretation. The combination with the MMSE improves its performance significantly, becoming equivalent to the CAMCOG.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sequential injection analysis (SIA) is proposed for managing microvolumes of sample and arsenic species solutions for speciation analysis by capillary electrophoresis focusing on the reduction of hazardous waste residues. An electronically controlled hydrodynamic injector was projected to introduce microvolumes of solutions prepared by SIA into the CE capillary with precision better than 2%. The determination of arsenite, arsenate, monomethylarsonic acid, dimethylarsinic acid, and arsenobetaine was performed from 50 mu L volumes of lyophilized urine and extract of shrimp with the system hyphenated to inductively coupled plasma mass spectrometry (CE-ICP-SFMS).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Uchida, MC, Crewther, BT, Ugrinowitsch, C, Bacurau, RFP, Moriscot, AS, and Aoki, MS. J Strength Cond Res 23(7): 2003-2008, 2009-This study assessed the effect of different resistance exercise scheme (RES) designs of similar total of load lifted on the responses of testosterone, cortisol, and creatine kinase (CK). Twenty-seven healthy males performed 1 of 4 bench press workouts described by the 1 repetition maximum (1RM) load: 4 sets of maximum repetitions at 50%-1RM (50%-1RM RES), 5 sets of maximum repetitions at 75%-1RM (75%-1RM RES), 10 sets of maximum repetitions at 90%-1RM (90%1RM RES), or 8 sets of maximum repetitions at 110%-1RM (110%-1RM RES). Each RES was equated by the total volume of load lifted (repetitions x sets x load). Blood samples, collected pre-exercise (Pre) and post-exercise (Post) at 1 and 24 hours (24 h), were analyzed for total and free testosterone, total cortisol, and CK. In general, testosterone and cortisol showed little change within or between the different RES (p > 0.05), possibly because of the relatively low volume lifted and/ or the small muscle mass activated by the bench press exercise. Cortisol was elevated after the 75%-1RM RES at the Post sample, with this response also exceeding the other RES (p < 0.05). The 24 h CK response was also elevated after the 75%-1RM RES (p < 0.05), thereby suggesting greater training strain for the same volume of load. These results confirm previous recommendations regarding the prescription of resistance exercise and the importance of total volume as a stimulus for activating the endocrine system and achieving long-term adaptation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nunes, JA, Crewther, BT, Ugrinowitsch, C, Tricoli, V, Viveiros, L, de Rose Jr, D, and Aoki, MS. Salivary hormone and immune responses to three resistance exercise schemes in elite female athletes J Strength Cond Res 25(8): 2322-2327, 2011-This study examined the salivary hormone and immune responses of elite female athletes to 3 different resistance exercise schemes. Fourteen female basketball players each performed an endurance scheme (ES-4 sets of 12 reps, 60% of 1 repetition maximum (1RM) load, 1-minute rest periods), a strength-hypertrophy scheme (SHS-1 set of 5RM, 1 set of 4RM, 1 set of 3RM, 1 set of 2RM, and 1set of 1RM with 3-minute rest periods, followed by 3 sets of 10RM with 2-minute rest periods) and a power scheme (PS-3 sets of 10 reps, 50% 1RM load, 3-minute rest periods) using the same exercises (bench press, squat, and biceps curl). Saliva samples were collected at 07:30 hours, pre-exercise (Pre) at 09:30 hours, postexercise (Post), and at 17:30 hours. Matching samples were also taken on a nonexercising control day. The samples were analyzed for testosterone, cortisol (C), and immunoglobulin A concentrations. The total volume of load lifted differed among the 3 schemes (SHS > ES > PS, p < 0.05). Postexercise C concentrations increased after all schemes, compared to control values (p < 0.05). In the SHS, the postexercise C response was also greater than pre-exercise data (p < 0.05). The current findings confirm that high-volume resistance exercise schemes can stimulate greater C secretion because of higher metabolic demand. In terms of practical applications, acute changes in C may be used to evaluate the metabolic demands of different resistance exercise schemes, or as a tool for monitoring training strain.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim. The purpose of present study was to compare the acute physiological responses to a circuit weight training with the responses to a combined circuit training (weight training and treadmill run). Methods. The sample consisted of 25 individuals at an average state of training, 10 men and 15 female, between 18 and 35 year old. There were selected 60 second sets of resistance exercises to the circuit weight training (CWT). Whereas in the combined circuit training (CCT), the subjects spent 30 seconds on the same resistance exercises and 30 seconds running on the treadmill. The rest intervals between the sets lasted 15 seconds. The analysis of variance (ANOVA) with 5% significance level was utilized to the statistical analysis of the results. Results. Comparing circuit training protocols, it was noted that CCT elicits a higher relative and absolute <(V)over dot>O(2) and energy expenditure values than CWT for both genders (P<0.05). Regarding inter-gender comparison, males showed higher absolute and relative <(V)over dot>O(2) and absolute energy expenditure values for both CWT and CCT than females (P<0.05). Females showed a significant greater % <(V)over dot>O(2max) value for both CWT and CCT. Due to the experimental conditions used to state both circuit training bouts (CWT and CCT), the <(V)over dot>O(2) rate found was higher than the values reported by previous studies which used heavier weight lift. Conclusion. CCT seems adequate to produce cardiovascular improvements and greater energy expenditure for both men and women, while CWT group classes are sufficient only for unfit women.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is evidence that cognitions (beliefs) and mood contribute to physical disability and work status in people with chronic pain. However, most of the current evidence comes from North America and Europe. This study examined the contribution of demographic, pain and psychosocial factors to disability and work status in chronic pain patients in two matched samples from quite different countries (Australia and Brazil). Data were collected from 311 chronic pain patients in each country. The results suggest that although demographic and pain variables (especially pain levels) contribute disability, self-efficacy beliefs made a significant contribution to disability in both samples. Age and educational level also contributed to unemployment in both samples. But there were some differences, with self-efficacy and physical disability contributing to work status only in the Brazilian sample. In contrast, depression was the only psychological risk factor for unemployment in the Australian sample. Catastrophising and pain acceptance did not contribute to disability or unemployment in either sample. These findings confirm key aspects of biopsychosocial models of pain in two culturally and linguistically different chronic pain samples from different countries. They suggest that different chronic pain populations may share more similarities than differences. (C) 2008 European Federation of Chapters of the International Association for the Study of Pain. Published

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The aim of this study was to analyze the prevalence of urinary incontinence (UI) in a community sample from the city of Sao Paulo. METHODS: This epidemiological survey was conducted at a family health program in Sao Paulo, Brazil, using randomized sampling. Data were collected by interviewing residents and were analyzed by Pearson`s correlation coefficients, chi-square tests, and logistic regression analysis. RESULTS: Seventy (10.7%) of the 657 subjects currently presented UI, including 50.7% with sporadic UI and 74.3% with UI upon moderate efforts. Ninety-three percent woke up during the night, 43.7% maintained continence until the bathroom, 63.4% had a sensation of wetness, and 77.5% reported no use of any continence aids. Female gender, advanced age, gynecologic or urologic surgery, dysuria, and urinary tract infection were correlated with UI (P < .001; r(2) = 0.572). CONCLUSION: The overall prevalence of UI was found to be high and was comparable to results from multiple countries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The purpose of this study was to compare the frequency and severity of perineal trauma during spontaneous birth with or without perineal injections of hyaluronidase (HAase). Methods: A randomized, placebo-controlled, double-blind clinical trial was conducted in a midwife-led, in-hospital birth center in Sao Paulo, Brazil. Primiparous women (N = 160) were randomly assigned to an experimental (n = 80) or control (n = 80) group. During the second stage of labor, women in the experimental group received an injection of 20.000 turbidity-reducing units of HAase in the posterior region of the perineum, and those in the control group received a placebo injection. The assessment of perineal outcome was performed by 2 independent nurse-midwives. A 1-tailed Fisher exact test was performed, and a P value < .025 was considered statistically significant. Results: Perineal integrity occurred in 34.2% of the experimental group and in 32.5% of the control group, which was not a statistically significant difference (P = .477). First-degree laceration was the most common trauma in the posterior region of the perineum in women in both groups (experimental = 56%, control = 42.6%). Severe perineal trauma occurred in 28.9% of the experimental group and 38.8% of the control group, which also was not a statistically significant difference (P =. 131). The depth of second-degree perineal lacerations in the experimental and control groups, measured by the Peri-Rule, was 1.9 cm and 2.3 cm, respectively. An episiotomy was performed in 11 women (experimental group = 3, control group = 8), and 4 (all in control group) had third-degree lacerations. Discussion: The use of injectable HAase did not increase the proportion of intact perineum and did not reduce the proportion of severe perineal trauma in our sample. J Midwifery Womens Health 2011; 56: 436-445 (C) 2011 by the American College of Nurse-Midwives.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

SILVA, B. M., F. J. NEVES, M. V. NEGRÃO, C. R. ALVES, R. G. DIAS, G. B. ALVES, A. C. PEREIRA, M. Urbana A. RONDON, J. E. KRIEGER, C. E. NEGRÃO, and A. C. DA NOBREGA. Endothelial Nitric Oxide Synthase Polymorphisms and Adaptation of Parasympathetic Modulation to Exercise Training. Med. Sci. Sports Exerc., Vol. 43, No. 9, pp. 1611-1618, 2011. Purpose: There is a large interindividual variation in the parasympathetic adaptation induced by aerobic exercise training, which may be partially attributed to genetic polymorphisms. Therefore, we investigated the association among three polymorphisms in the endothelial nitric oxide gene (-786T>C, 4b4a, and 894G>T), analyzed individually and as haplotypes, and the parasympathetic adaptation induced by exercise training. Methods: Eighty healthy males, age 20-35 yr, were genotyped by polymerase chain reaction-restriction fragment length polymorphism analysis, and haplotypes were inferred using the software PHASE 2.1. Autonomic modulation (i.e., HR variability and spontaneous baroreflex sensitivity) and peak oxygen consumption ((V) over dotO(2peak)) were measured before and after training (running, moderate to severe intensity, three times per week, 60 min.day(-1), during 18 wk). Results: Training increased (V) over dotO(2peak) (P < 0.05) and decreased mean arterial pressure (P < 0.05) in the whole sample. Subjects with the -786C polymorphic allele had a significant reduction in baroreflex sensitivity after training (change: wild type (-786TT) = 2% +/- 89% vs polymorphic (-786TC/CC) = -28% +/- 60%, median +/- quartile range, P = 0.03), and parasympathetic modulation was marginally reduced in subjects with the 894T polymorphic allele (change: wild type (894GG) = 8% +/- 67% vs polymorphic (894GT/TT) = -18% +/- 59%, median +/- quartile range, P = 0.06). Furthermore, parasympathetic modulation percent change was different between the haplotypes containing wild-type alleles(-786T/4b/894G) and polymorphic alleles at positions -786 and 894 (-786C/4b/894T) (-6% +/- 56% vs -41% +/- 50%, median T quartile range, P = 0.04). Conclusions: The polymorphic allele at position -786 and the haplotype containing polymorphic alleles at positions -786 and 894 in the endothelial nitric oxide gene were associated with decreased parasympathetic modulation after exercise training.