954 resultados para Electrical supply


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Growing awareness in corporate responsibility and issues related to sustainability is seen to increase innovativeness in a company as well as in its supply chain. The stakeholders’ awareness on sustainability has increased, and they demand the companies to identify sustainability risks and adapt procedures for mitigating them. The purpose of this thesis is to examine how risks are managed in sustainable supply chain. Definition of sustainability risks and risk management procedures construct the framework of the study. It is done through an empirical study conducted on 95 Finnish companies operating in the manufacturing industry. The data is acquired via an online questionnaire. The research has been conducted as a quantitative study utilizing the methods of statistical analysis, such as correlation analysis and factor analysis. The essential results of this thesis are identified risk-procedure connections, and the importance of different risks and procedures in the respondent companies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Today, renewable energy technologies and modern power electronics have made it feasible to implement low voltage direct current (LVDC) microgrids (MGs) ca-pable to island operation. Such LVDC networks are particularly useful in remote areas. However, there are still pending issues in island operated LVDC MGs like electrical safety and controlled operation, which should be addressed before wide-scale implementation. This thesis is focused on the overall protection of an island operated LVDC network concept, including protection against electrical shocks, mains equipment protection and protection of photovoltaic (PV) power sources and battery energy storage systems (BESSs). The topic is approached through ex-amination of the safety hazards and the appropriate methods to protect against them, comprising considerations for earthing system selection and realisation of the protection system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the recent years, smart grids have received great public attention. Many proposed functionalities rely on power electronics, which play a key role in the smart grid, together with the communication network. However, “smartness” is not the driver that alone motivates the research towards distribution networks based on power electronics; the network vulnerability to natural hazards has resulted in tightening requirements for the supply security, set both by electricity end-users and authorities. Because of the favorable price development and advancements in the field, direct current (DC) distribution has become an attractive alternative for distribution networks. In this doctoral dissertation, power electronic converters for a low-voltage DC (LVDC) distribution system are investigated. These include the rectifier located at the beginning of the LVDC network and the customer-end inverter (CEI) on the customer premises. Rectifier topologies are introduced, and according to the LVDC system requirements, topologies are chosen for the analysis. Similarly, suitable CEI topologies are addressed and selected for study. Application of power electronics into electricity distribution poses some new challenges. Because the electricity end-user is supplied with the CEI, it is responsible for the end-user voltage quality, but it also has to be able to supply adequate current in all operating conditions, including a short-circuit, to ensure the electrical safety. Supplying short-circuit current with power electronics requires additional measures, and therefore, the short-circuit behavior is described and methods to overcome the high-current supply to the fault are proposed. Power electronic converters also produce common-mode (CM) and radio-frequency (RF) electromagnetic interferences (EMI), which are not present in AC distribution. Hence, their magnitudes are investigated. To enable comprehensive research on the LVDC distribution field, a research site was built into a public low-voltage distribution network. The implementation was a joint task by the LVDC research team of Lappeenranta University of Technology and a power company Suur-Savon S¨ahk¨o Oy. Now, the measurements could be conducted in an actual environment. This is important especially for the EMI studies. The main results of the work concern the short-circuit operation of the CEI and the EMI issues. The applicability of the power electronic converters to electricity distribution is demonstrated, and suggestions for future research are proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Global energy consumption has been increasing yearly and a big portion of it is used in rotating electrical machineries. It is clear that in these machines energy should be used efficiently. In this dissertation the aim is to improve the design process of high-speed electrical machines especially from the mechanical engineering perspective in order to achieve more reliable and efficient machines. The design process of high-speed machines is challenging due to high demands and several interactions between different engineering disciplines such as mechanical, electrical and energy engineering. A multidisciplinary design flow chart for a specific type of high-speed machine in which computer simulation is utilized is proposed. In addition to utilizing simulation parallel with the design process, two simulation studies are presented. The first is used to find the limits of two ball bearing models. The second is used to study the improvement of machine load capacity in a compressor application to exceed the limits of current machinery. The proposed flow chart and simulation studies show clearly that improvements in the high-speed machinery design process can be achieved. Engineers designing in high-speed machines can utilize the flow chart and simulation results as a guideline during the design phase to achieve more reliable and efficient machines that use energy efficiently in required different operation conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hot and dry weather conditions during soybean [Glycine max (L.) Merrill] seed maturation can cause forced maturation of the seed, resulting in the production of high levels of green seed, which may be detrimental to seed germination. These stressful conditions were imposed on soybean plants during seed maturation to investigate the production of green seeds and seed quality. Plants of the CD 206 cultivar were grown in a greenhouse until the R5.5 growing stage and then transferred to phytotrons at R6 and R7.2 for stress induction. Plants were subjected to two temperature regimes, high (28ºC to 36ºC) and normal (19ºC to 26ºC), and four soil water availability conditions, control (adequate water supply), 30% gravimetric moisture (GM), 20% GM and no water supply. Seed were harvested at R9. Green seed percentages and 100-seed weights from the lower, middle and upper thirds of each plant were determined. Seed quality was assessed by germination, tetrazolium (viability and vigor) and electrical conductivity tests. Occurrence of green seed varied from 9% to 86%, depending on the severity of the stresses imposed. High temperature, coupled with no water supply at R6, resulted in a pronounced occurrence of green seeds. There was no difference in the percentage of green seeds among the plant segments. Seed quality was negatively affected by the incidence of green seeds. A procedure for screening soybean genotypes in a phytotron for their tolerance and/or susceptibility to the production of green seeds was developed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of new procedures for quickly obtaining accurate information on the physiological potential of seed lots is essential for developing quality control programs for the seed industry. In this study, the effectiveness of an automated system of seedling image analysis (Seed Vigor Imaging System - SVIS) in determining the physiological potential of sun hemp seeds and its relationship with electrical conductivity tests, were evaluated. SVIS evaluations were performed three and four days after sowing and data on the vigor index and the length and uniformity of seedling growth were collected. The electrical conductivity test was made on 50 seed replicates placed in containers with 75 mL of deionised water at 25 ºC and readings were taken after 1, 2, 4, 8 and 16 hours of imbibition. Electrical conductivity measurements at 4 or 8 hours and the use of the SVIS on 3-day old seedlings can effectively detect differences in vigor between different sun hemp seed lots.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this work was to describe and compare sourcing practices and challenges in different geographies, to discuss possible options to advance sustainability of global sourcing, and to provide examples to answer why sourcing driven by sustainability principles is so challenging to implement. The focus was on comparison between Europe & Asia & South-America from the perspective of sustainability adoption. By analyzing sourcing practices of the case company it was possible to describe main differences and challenges of each continent, available sourcing options, supplier relationships and ways to foster positive chance. In this qualitative case study gathered theoretical material was compared to extensive sourcing practices of case company in a vast supplier network. Sourcing specialist were interviewed and information provided by them analyzed in order to see how different research results and theories are reflecting reality and to find answers to proposed research questions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this thesis is to find out how outbound logistics process can be improved by reducing unnecessary waste in a globally dispersed make-to-order (MTO) supply chain. The research problem was addressed by a multinational corporation that aims to find a solution for reducing unnecessary waste in their outbound logistics process. The focus is on customized products that are delivered via sea transportation. Theoretical framework for improving outbound logistics processes in globally dispersed MTO supply chain was created based on business process management, Porter’s value chain theory, value stream mapping and current reality tree. The empirical research was conducted by using constructive approach due to its ability to research a practical problem and to improve the existing practices. The data was collected from ten semi-structured interviews and three non-participant observations. By analysing the data and applying the theoretical framework, five types of waste were detected in the process that were seen to derive from six root causes. Practical solution was constructed to reduce the waste in the process by combining the existing literature with the ideas raising from empirical data. The results of this thesis suggest that a MNC with a globally dispersed MTO supply chain can improve its outbound logistics process by applying activities that enhance internal and external integration, collaboration and coordination, and increase predictability of the process. This research has practical relevance both for the case company as well as for other MNCs with globally dispersed MTO supply chains that aim to improve their outbound logistics processes. This research contributes to the BPM and CRA research by providing an evidence for their applicability in the new context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

D-luokan vahvistimien etu perinteisiin A- tai AB-luokan vahvistimiin nähden on niitten korkea hyötysuhde ja pieni koko. Lisäksi ne ovat edullisia ja niihin voidaan asentaa pienemmät jäähdytyslevyt kuin perinteisiin vahvistimiin korkean hyötysuhteen ansiosta. Tässä tutkimuksessa asennetaan Peavey Solo –kitaravahvistimen pääteasteena toimivan AB-luokan päätevahvistimen tilalle tehokkaampi ja uudempaa vahvistinluokkaa edustava D-luokan vahvistin. Tutkimuksessa selvitetään, miten D-luokan vahvistimella toteutettu kytkentä toimii verrattuna alkuperäiseen kytkentään tutkimalla kitaravahvistimelle tyypillisiä sähköisiä ominaisuuksia. Työ toteutetaan mittauksin. Koska työssä olevissa kytkennöissä on jännitteisiä osia, on siinä perehdyttävä sähköturvallisuuteen. D-luokan vahvistin asettaa tietyt sähkötekniset kestävyysvaatimukset kytkennän teholähteelle ja kaiutinelementille, jolloin työssä paneudutaan myös niiden valintaan. D-luokan vahvistimeen päivitetyn kytkennän tuottamat äänenpainetasot olivat valtaosassa mittauksia suuremmat kuin alkuperäisellä kytkennällä. Äänenpainetasojen mittaustilanteissa myös kuormalle syötetyt tehot olivat suuremmat päivitetyllä kytkennällä verrattuna alkuperäiseen. Suurin päivitetyn kytkennän kuorman teho 72,72 W saavutettiin, kun kaiutinelementin yli oli 24,12 V:n jännitteen tehollisarvo ja kuorman teho oli noin 36 kertaa suurempi kuin alkuperäisellä kytkennällä. D-luokan vahvistimen mitatut harmonisen särön arvot ovat huomattavasti pienempiä kuin alkuperäisellä vahvistimella. Muokkaamattoman vahvistimen mitatusta sähköisestä taajuusvasteeesta nähdään, että alkuperäinen vahvistin korostaa tiettyjä taajuuksia, kun D-luokan vahvistimen taajuusvaste on sen sijaan likimain tasainen. Akustinen taajuusvaste ei ole niin tasainen D-luokan vahvistimeen päivitetyllä kytkennällä kuin alkuperäisellä kytkennällä ja sillä on myös kapeampi taajuusalue. Jos päivitetyn kytkennän sointia haluttaisiin parantaa, pitäisi tutkia lisää akustiseen taajuusvasteeseen vaikuttavia asioita.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of ventricular rate (VR) on the outcome of electrical cardioversion (ECV) of acute atrial fibrillation (AF) is currently unknown. We aimed to determine the effect of VR during acute AF on the success of ECV, recurrence of AF and occurrence of post-cardioversion complications in 30 days follow-up. All ECVs performed in patients with acute atrial fibrillation lasting <48 hours in 2 Finnish university hospitals during 2003-2010 and 1 central hospital during 2010 were retrospectively identified. A total of 6,624 ECVs were performed in 2,821 consecutive patients. VR≤60 BPM was defined low and VR≥160 BPM high. The median VR before ECV was 109 BPM. The success rate of ECV was 94.2%. Bradycardia occurred in 62 (0.9%) and thromboembolic complications in 39 (0.6%) ECVs. Low VR was observed before 75 (1.1%) ECVs and male sex was its only independent predictor. High VR was observed in 165 (2.5%) ECVs. The independent predictors of high VR were younger age, <12 h episode duration, no previous history of AF and alcohol abuse. Low or high VR were not related to the success of ECV, incidence of thromboembolic or bradycardic complications, or recurrence of AF, although VR was significantly (p<0.001) lower in the patients in whom AF recurred. In conclusion, ECV of acute AF is an effective procedure and VR during AF does not affect its efficacy, the maintenance of sinus rhythm or the incidence of bradycardic, thromboembolic or other complications during 30 days follow-up after ECV. Low VR is predominately observed in male patients, while high VR was a feature related to a shorter history of AF and high alcohol-intake.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this bachelor’s thesis are examined the benefits of current distortion detection device application in customer premises low voltage networks. The purpose of this study was to find out if there are benefits for measuring current distortion in low-voltage residential networks. Concluding into who can benefit from measuring the power quality. The research focuses on benefits based on the standardization in Europe and United States of America. In this research, were also given examples of appliances in which current distortion detection device could be used. Along with possible illustration of user interface for the device. The research was conducted as an analysis of the benefits of current distortion detection device in residential low voltage networks. The research was based on literature review. The study was divided to three sections. The first explain the reasons for benefitting from usage of the device and the second portrays the low-cost device, which could detect one-phase current distortion, in theory. The last section discuss of the benefits of usage of current distortion detection device while focusing on the beneficiaries. Based on the result of this research, there are benefits from usage to the current distortion detection device. The main benefitting party of the current distortion detection device was found to be manufactures, as they are held responsible of limiting the current distortion on behalf of consumers. Manufactures could adjust equipment to respond better to the distortion by having access to on-going current distortion in network. The other benefitting party are system operators, who would better locate distortion issues in low-voltage residential network to start prevention of long-term problems caused by current distortion early on.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this research is to create a current state analysis of pulp supply chain processes from production planning to deliveries to customers. A cross-functional flowchart is being used to model these processes. These models help finding key performance indicators (KPIs) which enable examinations of the supply chain efficiency. Supply chain measures in different processes reveal the changes need processes that affect the whole supply chain and its efficiency and competitiveness. Structure of pulp supply chain differs from most of the other supply chains. The fact that there are big volumes of bulk products, small product variations and supply forecasts are made for the year ahead make the difference. This factor brings different benefits but also challenges when developing supply chain. This thesis divides pulp supply chain in three different main categories: production planning, warehousing and transportation. It provides tools for estimating the functionality of supply chain as well as developing the efficiency for different functions of supply chain. By having a better understanding of supply chain processes and measurement the whole supply chain structure can be developed significantly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä diplomityössä tarkasteltiin Nissan Leaf -sähköauton käytetyn litiumakun soveltuvuutta UPS-varavirtalaitteen energialähteeksi. Kun akku on heikentynyt niin ettei sen kapasiteetti enää ole riittävä autokäyttöön, sitä voidaan kuitenkin vielä hyödyntää muissa sovelluksissa, kuten UPS-laitteessa. Työ sai alkunsa osana GreenDataNet-projektia, jossa pyritään kehittämään datakeskuksiin ympäristöä vähemmän kuormittavia ratkaisuja käyttämällä uusiutuvia energialähteitä, akkujen uusiokäytöllä, sekä energianhallinnan optimoinnilla. Työssä käytiin läpi akun ja sen ohjausjärjestelmän ominaisuuksia, kerrottiin UPS:in ohjelmistoon tehdyistä muutoksista sekä esitettiin testitulokset. Lopputuloksena todettiin akun sopivan muuten hyvin UPS-käyttöön, mutta vaadittu päivittäinen kennojännitteiden tasaus ja sen aiheuttama katkos energian saatavuuteen heikentää UPSin käyttövarmuutta kuorman suojauksessa. Lopussa esitettiin muutamia ehdotuksia tämän ongelman korjaamiseksi.