926 resultados para no conforming mesh
Resumo:
Concrete is a universal material in the construction industry. With natural resources like sand and aggregate, fast depleting, it is time to look for alternate materials to substitute these in the process of making concrete. There are instances like exposure to solar radiation, fire, furnaces, and nuclear reactor vessels, special applications like missile launching pads etc., where concrete is exposed to temperature variations In this research work, an attempt has been made to understand the behaviour of concrete when weathered laterite aggregate is used in both conventional and self compacting normal strength concrete. The study has been extended to understand the thermal behaviour of both types of laterised concretes and to check suitability as a fire protection material. A systematic study of laterised concrete considering parameters like source of laterite aggregate, grades of Ordinary Portland Cement (OPC) and types of supplementary cementitious materials (fly ash and GGBFS) has been carried out to arrive at a feasible combination of various ingredients in laterised concrete. A mix design methodology has been proposed for making normal strength laterised self compacting concrete based on trial mixes and the same has also been validated. The physical and mechanical properties of laterised concretes have been studied with respect to different variables like exposure temperature (200°C, 400°C and 600°C) and cooling environment (air cooled and water cooled). The behaviour of ferrocement elements with laterised self compacting concrete has also been studied by varying the cover to mesh reinforcement (10mm to 50mm at an interval of 10mm), exposure temperature and cooling environment.
Resumo:
In the present study. extensive investigations were carried out on various factors affecting the selectivity of prawn gill nets with reference to material, mesh size, coefficient of hanging secolouration. Effect of tidal current on fishing height of prawn gill net and seasonal variation of catch during the course of these investigations were also studied.
Resumo:
Low-density polyethylene was mixed with dextrin having different particle sizes (100, 200 and 300 mesh). Various compositions were prepared and their mechanical properties were evaluated and thermal studies have been carried out. Biodegradability of these samples has been checked using liquid culture medium containing Vibrios (an amylase producing bacteria), which were isolated from marine benthic environment. Soil burial test was done and reprocessability of these samples was evaluated. The results indicate that the newly prepared blends are reprocessable without sacrificing much of their mechanical properties. The biodegradability tests on these blends indicate that these are partially biodegradable
Resumo:
We deal with the numerical solution of heat conduction problems featuring steep gradients. In order to solve the associated partial differential equation a finite volume technique is used and unstructured grids are employed. A discrete maximum principle for triangulations of a Delaunay type is developed. To capture thin boundary layers incorporating steep gradients an anisotropic mesh adaptation technique is implemented. Computational tests are performed for an academic problem where the exact solution is known as well as for a real world problem of a computer simulation of the thermoregulation of premature infants.
Resumo:
Mesh generation is an important step inmany numerical methods.We present the “HierarchicalGraphMeshing” (HGM)method as a novel approach to mesh generation, based on algebraic graph theory.The HGM method can be used to systematically construct configurations exhibiting multiple hierarchies and complex symmetry characteristics. The hierarchical description of structures provided by the HGM method can be exploited to increase the efficiency of multiscale and multigrid methods. In this paper, the HGMmethod is employed for the systematic construction of super carbon nanotubes of arbitrary order, which present a pertinent example of structurally and geometrically complex, yet highly regular, structures. The HGMalgorithm is computationally efficient and exhibits good scaling characteristics. In particular, it scales linearly for super carbon nanotube structures and is working much faster than geometry-based methods employing neighborhood search algorithms. Its modular character makes it conducive to automatization. For the generation of a mesh, the information about the geometry of the structure in a given configuration is added in a way that relates geometric symmetries to structural symmetries. The intrinsically hierarchic description of the resulting mesh greatly reduces the effort of determining mesh hierarchies for multigrid and multiscale applications and helps to exploit symmetry-related methods in the mechanical analysis of complex structures.
Resumo:
Robots must act purposefully and successfully in an uncertain world. Sensory information is inaccurate or noisy, actions may have a range of effects, and the robot's environment is only partially and imprecisely modeled. This thesis introduces active randomization by a robot, both in selecting actions to execute and in focusing on sensory information to interpret, as a basic tool for overcoming uncertainty. An example of randomization is given by the strategy of shaking a bin containing a part in order to orient the part in a desired stable state with some high probability. Another example consists of first using reliable sensory information to bring two parts close together, then relying on short random motions to actually mate the two parts, once the part motions lie below the available sensing resolution. Further examples include tapping parts that are tightly wedged, twirling gears before trying to mesh them, and vibrating parts to facilitate a mating operation.
Resumo:
In this text, we present two stereo-based head tracking techniques along with a fast 3D model acquisition system. The first tracking technique is a robust implementation of stereo-based head tracking designed for interactive environments with uncontrolled lighting. We integrate fast face detection and drift reduction algorithms with a gradient-based stereo rigid motion tracking technique. Our system can automatically segment and track a user's head under large rotation and illumination variations. Precision and usability of this approach are compared with previous tracking methods for cursor control and target selection in both desktop and interactive room environments. The second tracking technique is designed to improve the robustness of head pose tracking for fast movements. Our iterative hybrid tracker combines constraints from the ICP (Iterative Closest Point) algorithm and normal flow constraint. This new technique is more precise for small movements and noisy depth than ICP alone, and more robust for large movements than the normal flow constraint alone. We present experiments which test the accuracy of our approach on sequences of real and synthetic stereo images. The 3D model acquisition system we present quickly aligns intensity and depth images, and reconstructs a textured 3D mesh. 3D views are registered with shape alignment based on our iterative hybrid tracker. We reconstruct the 3D model using a new Cubic Ray Projection merging algorithm which takes advantage of a novel data structure: the linked voxel space. We present experiments to test the accuracy of our approach on 3D face modelling using real-time stereo images.
Resumo:
We develop efficient techniques for the non-rigid registration of medical images by using representations that adapt to the anatomy found in such images. Images of anatomical structures typically have uniform intensity interiors and smooth boundaries. We create methods to represent such regions compactly using tetrahedra. Unlike voxel-based representations, tetrahedra can accurately describe the expected smooth surfaces of medical objects. Furthermore, the interior of such objects can be represented using a small number of tetrahedra. Rather than describing a medical object using tens of thousands of voxels, our representations generally contain only a few thousand elements. Tetrahedra facilitate the creation of efficient non-rigid registration algorithms based on finite element methods (FEM). We create a fast, FEM-based method to non-rigidly register segmented anatomical structures from two subjects. Using our compact tetrahedral representations, this method generally requires less than one minute of processing time on a desktop PC. We also create a novel method for the non-rigid registration of gray scale images. To facilitate a fast method, we create a tetrahedral representation of a displacement field that automatically adapts to both the anatomy in an image and to the displacement field. The resulting algorithm has a computational cost that is dominated by the number of nodes in the mesh (about 10,000), rather than the number of voxels in an image (nearly 10,000,000). For many non-rigid registration problems, we can find a transformation from one image to another in five minutes. This speed is important as it allows use of the algorithm during surgery. We apply our algorithms to find correlations between the shape of anatomical structures and the presence of schizophrenia. We show that a study based on our representations outperforms studies based on other representations. We also use the results of our non-rigid registration algorithm as the basis of a segmentation algorithm. That algorithm also outperforms other methods in our tests, producing smoother segmentations and more accurately reproducing manual segmentations.
Resumo:
The quantitative estimation of Sea Surface Temperatures from fossils assemblages is a fundamental issue in palaeoclimatic and paleooceanographic investigations. The Modern Analogue Technique, a widely adopted method based on direct comparison of fossil assemblages with modern coretop samples, was revised with the aim of conforming it to compositional data analysis. The new CODAMAT method was developed by adopting the Aitchison metric as distance measure. Modern coretop datasets are characterised by a large amount of zeros. The zero replacement was carried out by adopting a Bayesian approach to the zero replacement, based on a posterior estimation of the parameter of the multinomial distribution. The number of modern analogues from which reconstructing the SST was determined by means of a multiple approach by considering the Proxies correlation matrix, Standardized Residual Sum of Squares and Mean Squared Distance. This new CODAMAT method was applied to the planktonic foraminiferal assemblages of a core recovered in the Tyrrhenian Sea. Kew words: Modern analogues, Aitchison distance, Proxies correlation matrix, Standardized Residual Sum of Squares
Resumo:
Se desconoce en la actualidad en Colombia la calidad de la interpretación de los gases arteriales por parte de los residentes de medicina de emergencias. Los gases arteriales es una de las ayudas diagnósticas de más rápida consecución en el servicio de urgencias y más utilizadas por ser indispensable en la valoración de patologías de alta prevalencia como son las enfermedades respiratorias y la sepsis. Su mala interpretación puede llevar a mal direccionamiento del manejo de pacientes en estado crítico por lo que es indefectible que los residentes logren un buen entrenamiento en la interpretación de los mismos. Por esta razón se realiza este estudio analítico de concordancia con recolección prospectiva, de corte transversal que busca determinar el grado de concordancia en la interpretación de gases arteriales de los residentes del programa de Medicina de Emergencias de la Universidad del Rosario y especialista en cuidado crítico, así como la interpretación entre ellos según su nivel de entrenamiento y describir cuáles son los hallazgos que encuentran en la interpretación de los mismos. Se recolectaron 60 gases arteriales realizados a paciente hospitalizados en la unidad de cuidados intensivos de la Fundación Santa Fe de Bogotá y se halló la concordancia entre la lectura de los residentes del programa de Medicina de Emergencias y un intensivista. Encontrando una concordancia moderada (r 0.445 y 0.442, ) en las respuestas identificadas en los residentes de segundo y tercer año de residencia(p:0,000y0,01).(MESH: Blood Gas Análisis, Emergency Medical Services, Education, Medical, Graduate)
Resumo:
Los avances tecnológicos y el desarrollo de las diferentes técnicas de anestesia regional; bloqueos de nervio periférico, han permitido el crecimiento de esta área expandiendo su uso a otros escenarios. El presente documento es una guía para su adecuada realización y busca incrementar la seguridad en una técnica que cada día tiene más adeptos. Es necesario conocer los principios fisiológicos de la neuroconducción y el funcionamiento del estimulador de nervio periférico, al igual que la anatomía de troncos y nervios periféricos, hecho que conducirá a un mejor aprendizaje de las técnicas de abordaje. El presente documento espera disminuir la presentación de complicaciones en esta técnica anestésica.Materiales y métodos: Búsqueda de literatura en las bases de datos referenciales de PubMed, Cochrane, Scielo, LILACS y se Amplio según la bibliografía encontrada en los artículos revisados por los autores; la búsqueda fue hecha en términos MeSH incluidos en las palabras claves. El Propósito de esta revisión es dar pautas generales fáciles de entender en la realización de bloqueos de nervio periférico, permitiendo su realización adecuada y segura.
Resumo:
Antecedentes El paro cardiarrespiratorio en el paciente pediátrico incluye, entre otros procedimientos, la aplicación de la desfibrilación. Sin embargo se desconoce la dosis óptima para realizarla. Objetivo Evaluar la evidencia disponible sobre las dosis de desfibrilación que deben ser empleadas en el paciente pediátrico durante la reanimación cerebro cardiopulmonar. Metodología Se realizó una revisión sistemática de la literatura con búsqueda a través de las bases de datos PUBMED, OVID, EMBASE y LILACS y el registro de ensayos clínicos de los Estados Unidos de cualquier tipo de diseño metodológico en animales o humanos que explorará las dosis de carga que deben emplearse en la desfibrilación. Se realizó un análisis cualitativo de la información y se extrajeron las medidas de resumen. Resultados Se encontraron tres estudios de cohortes y un modelo en animales que reportan resultados contradictorios. Con base en la evidencia disponible puede afirmarse que la dosis de carga inicial de 2 J/Kg utilizada en la actualidad reporta menores proporciones de eficacia que las históricas. Por otra parte no existe evidencia disponible que permita dar comprender cual es la dosis de carga óptima que deba utilizarse. Conclusión No existe evidencia sobre la dosis de carga óptima que deba ser utilizada en la desfibrilación del paciente pediátrico. Deben diseñarse y realizarse estudios observacionales y ensayos clínicos que permitan dar respuesta a esta pregunta. Palabras claves (MeSH): Desfibrilación, paro cardiaco, reanimación cardiopulmonar, revisión sistemática como tópico.
Resumo:
La psiquiatría como área del conocimiento, debe expandirse a nuevos campos, es por esto que el trabajo y todas sus implicaciones adquieren una importancia fundamental en el entendimiento del proceso de salud-enfermedad. Objetivo: esta revisión de la literatura, busca describir la evidencia que existe actualmente sobre la historia de la psiquiatría laboral, sus posibles aplicaciones, la epidemiología y perfil sociodemografico de los trabajadores afectados por enfermedades mentales, estrategias de prevención, estrés laboral, riesgos psicosociales, calificación y la utilidad de la psiquiatría en el accidente laboral. Métodos: Se realizó una búsqueda sistemática de la literatura en PUBMED de los siguientes términos MESH: PSYCHIATRY y WORKPLACE, mediante el conector [AND], limitándose los artículos por idioma (ingles y español). Posteriormente se realizo una búsqueda secundaria de las bibliografías citadas. Conclusiones: Los cambios de las condiciones laborales y del mundo, en general implican una serie de modificaciones en la concepción y aplicación de la psiquiatría, generando unas opciones importantes en la prevención y tratamiento de las enfermedades exacerbadas o causadas por el trabajo.
Resumo:
Introducción: La cesárea es un procedimiento quirúrgico considerado como inocuo por algunas personas, sin tener en cuenta las posibles consecuencias en los embarazos siguientes. Existe literatura que evidencia un aumento en el riesgo para abrupcio de placenta, acretismo placentario, placenta previa, mortalidad materna, sepsis materna, ingreso a UCI, al igual que apgar bajo, bajo peso neonatal, distress respiratorio,entre otros.El objetivo de este estudio fue evaluar el impacto del antecedente de cesárea en la morbilidad materna y neonatal mediante una revisión sistemática de literatura. Metodología Se realizó una búsqueda en diferentes bases de datos desde 1996 hasta 2011 sobre el antecedente de cesárea y sus posibles riesgos en el desenlace maternos y perinatales. Se utilizaron variaciones de términos MeSH. Resultados La búsqueda arrojó un total de 2.483 artículos, entre los cuales fueron escogidos 247 por criterios de elegibilidad.Estos fueron evaluados en su totalidad. Posteriormente se realizó el análisis metanalítico de cada uno de los desenlaces. Los resultados deben interpretarse con precaución pues la calidad metodológica de algunos estudios fue variable. En el riesgo conjunto se encontraron resultados estadísticamente significativos en placenta previa, apgar bajo, histerectomía periparto. Discusión El antecedente de cesárea presenta un riesgo aumentado para los siguientes embarazos en la morbilidad tanto materna como neonatal. Faltan más estudios analíticos para definir el verdadero papel de la cesarea.
Resumo:
El prolapso del piso pélvico es una entidad frecuente, especialmente en pacientes postmenopáusicas y en su gran mayoría requiere tratamiento quirúrgico. En este estudio comparamos la aparición de complicaciones postoperatorias tempranas entre la colporrafia anterior con técnica clásica (TC) versus la colporrafia anterior con técnica de sitio especifico (CSE). Se realizó un estudio observacional analítico, retrospectivo, de dos cohortes de pacientes que requirieron colporrafia anterior entre agosto de 2009 hasta junio de 2012. Las características de cada grupo fueron homogéneas y comparables. El desenlace de mayor frecuencia fue dehiscencia de la línea de sutura, sin embargo, no se encontraron diferencias estadísticamente significativas entre las dos técnicas. La aparición de reprolapso temprano y el diagnóstico de abscesos o hematomas presentaron frecuencias que carecen de diferencia significativa. No hubo complicaciones tempranas graves tales como sangrado intraoperatoria mayor o lesiones vesicouretrales. Los resultados sugieren que las dos técnicas tienen una incidencia baja de complicaciones postoperatorias tempranas y por lo tanto parecen ser seguros dentro del manejo quirúrgico del prolapso del componente anterior del piso pélvico.