999 resultados para air circulation
Resumo:
The present paper constitutes a synthesis of the results gotten during the five campaigns of air quality measurement in the years of 2003 and 2004 carried out in the Portuguese city of Viana do Castelo to characterise the reference situation and to accompany the Polis Programme, an urban re-qualification and environmental valorisation plan. The main objective of the monitoring programme consisted of the evaluation of atmospheric pollutants whose levels were susceptible of enhancement in the course of the urbanistic public works. The presented results refer to measurements performed in two distinct places of this city, comprising various consecutive days of acquisition that include, at least, one day of weekend.
Resumo:
Daily records of hospital admissions due to cardiorespiratory diseases and levels of PM10, SO2, CO, NO, NO2, and O3 were collected from 1999-2004 to evaluate the relationship between air pollution and morbidity in Lisbon. Generalised additive Poisson regression models were adopted, controlling for temperature, humidity, and both short and long-term seasonality. Significant positive associations, lagged by 1 or 2 days, were found between markers of traffic-related pollution (CO and NO2) and cardiocirculatory diseases in all age groups. Increased childhood emergency admissions for respiratory illness were significantly correlated with the 1-day lagged SO2 levels coming from industrial activities.
Resumo:
Simultaneous measurements of outdoor and indoor pollution were performed at three schools in Lisbon. Volatile organic compounds (VOCs), formaldehyde and NO2 were passively monitored over a two-week period. Bacterial and fungal colony-forming units and comfort parameters were also monitored at classrooms and playgrounds. The highest indoor levels of CO2 (2666 μg/m³), NO2 (40.3 μg/m³), VOCs (10.3 μg/m³), formaldehyde (1.03 μg/m³) and bioaerosols (1634 CFU/m³), and some indoor/outdoor ratios greater than unity, suggest that indoor sources and building conditions might have negative effects on air indoors. Increasing ventilation rates and use of low-emission materials would contribute towards improving indoor air quality.
Resumo:
In this communication we describe the application of a conductive polymer gas sensor as an air pressure sensor. The device consists of a thin doped poly(4'-hexyloxy-2,5-biphenylene ethylene) (PHBPE) film deposited on an interdigitated metallic electrode. The sensor is cheap, easy to fabricate, lasts for several months, and is suitable for measuring air pressures in the range between 100 and 700 mmHg.
Resumo:
A distinctive design feature of steam boiler with natural circulation is the presence of the steam drum which plays a role of the separator of vapor from the flow of water-and-steam mixture coming into steam drum from the furnace tubes. Steam drum with unheated downcomer tubes, deducing from it, and riser (screen/furnace tubes) inside the furnace is a closed circulation loop in which movement of water (downcomer tubes) and water-and-steam mixture (riser tubes) is organized. The movement of the working fluid is appears due to occurrence of the natural pressure, determined by the difference in hydrostatic pressure and the mass of water and water-and-steam mixtures in downcomer and riser tubes and called the driving pressure of the natural circulation:
Resumo:
A distinctive design feature of steam boiler with natural circulation is the presence of the steam drum which plays a role of the separator of vapor from the flow of water-and-steam mixture coming into steam drum from the furnace tubes. Steam drum with unheated downcomer tubes, deducing from it, and riser (screen/furnace tubes) inside the furnace is a closed circulation loop in which movement of water (downcomer tubes) and water-and-steam mixture (riser tubes) is organized. The movement of the working fluid is appears due to occurrence of the natural pressure, determined by the difference in hydrostatic pressure and the mass of water and water-and-steam mixtures in downcomer and riser tubes and called the driving pressure of the natural circulation: S drive = H steam (ρ down + ρ mix) g where: ρ down - density of water in downcomer tubes; ρ mix - density of water in riser tubes; H steam - height of steam content section; g - acceleration of gravity. In steam boilers with natural circulation the circulation rate is usually between 10 and 30. Thus, consumption of water in the circulation circuit “circulation rate times” more than steam output of the boiler. There are two aspects of the design of natural water circulation loops. One is to ensure a sufficient mass flux of circulating water to avoid burnout of evaporator tubes. The other is to avoid tube wall temperature fluctuation and tube vibration due to oscillation of circulation velocity. The design criteria are therefore reduced, in principle, to those of critical heat flux, critical flow rate for burnout, and flow instability. In practical design, however, the circulation velocity and the void fraction at the evaporator tube outlet are used as the design criteria (Seikan I., et. al., 1999). This study has been made with assumption that the heat flux in the furnace of the boiler even all the time. The target of the study was to define the circulation rate of the boiler, thus average heat flux do not change it. I would like to acknowledge professionals from “Foster Wheeler” company for good and comfortable cooperation.
Resumo:
Oopperasta Faust.
Resumo:
Tämän työn on teettänyt Vanhan Ruukin Kiinteistöpalvelu Oy ja työ on toteutettu kandidaatintyönä Lappeenrannan Teknilliselle Yliopistolle. Työn tarkoituksena oli selvittää työn teettäjän puolesta paineilmakompressoreiden lämmön talteenoton toimintaa sekä etsiä mahdollisia parannuskohteita järjestelmän hyötysuhteen nostamiseksi. Työ rajattiin koskemaan lämmön talteenoton yhtä lämmönvaihtopatteria ja siihen liittyvää nestekiertolaitteistoa. Syynä työn tekemiselle oli epäilys lämmön talteenoton huonosta hyötyprosentista. Tässä työssä oli tavoitteena ottaa kantaa myös mahdollisiin rahallisiin säästöihin joita järjestelmän kunnollisella toimintaan saattamisella olisi.
Resumo:
ABSTRACTWhile a number of papers have shown that subway systems have an impact on the air quality through the release of particulate matters, no information about the impact of such particles on tree attributes is available. Tree leaves from three different species from the exit side of a subway station in Rio de Janeiro, Brazil, were more asymmetrical than leaves from the entrance side. This leaves also presenting changes in leaves cuticle and chlorophyll content.
Resumo:
This work is a study of the implementation of a classical controller using a tuning method referred to as IMC (Internal Model Control) and aimed at the reduction of electrical energy consumption by the appropriate relation between energy consumption and the cooling time with forced air. The supervisory system installed was able to manipulate the variable of frequency of the signal power of the exhaust fan engine (forced air module), to accelerate or decelerate the loss of heat from the product to be cooled by airflow variation that passes through the mass of the produce. The results demonstrated a reduction in energy consumption from 64% and an increase of only 8% in the cooling time to the system using PI/IMC (Proportional - Integral with IMC) tuning method compared with the system in its operating nominal condition. This PI/IMC control may be implemented directly in a frequency converter, without the need to purchase a computer or PLC (programmable logic controller) to run the dedicated application, increasing its economical viability.
Resumo:
In the forced-air cooling process of fruits occurs, besides the convective heat transfer, the mass transfer by evaporation. The energy need in the evaporation is taken from fruit that has its temperature lowered. In this study it has been proposed the use of empirical correlations for calculating the convective heat transfer coefficient as a function of surface temperature of the strawberry during the cooling process. The aim of this variation of the convective coefficient is to compensate the effect of evaporation in the heat transfer process. Linear and exponential correlations are tested, both with two adjustable parameters. The simulations are performed using experimental conditions reported in the literature for the cooling of strawberries. The results confirm the suitability of the proposed methodology.
Resumo:
To maintain a competitive development of the Brazilian aviculture, some measures must be taken to enable the identification and reduction of risks to the health of birds, as well as for the physical environment. Therefore, the aim of this study was to evaluate the effectiveness of three different systems of minimum ventilation (positive pressure - SVMP, negative pressure - SVMN and natural ventilation - SVMNat) in the air quality during the first 21 days of life of broiler chicks, during winter. Three points were selected along the length to verify ammonia, carbon monoxide and oxygen concentrations at 3a.m., 9a.m., 3p.m. and 9p.m., by the respiration level of birds and workers. The averages of pollutant gases did not exceed the tolerance levels for the three minimum ventilation systems evaluated, which is 20 and 10ppm for the birds level and 20 and 39ppm for the workers level, for ammonia and carbon monoxide, respectively. It was evident that the minimum ventilation systems were appropriately sized for the required minimum ambient air renovation, in respect to ventilation rates applied for the SVMN and SVMP systems, and with air velocity at levels that do not stress the chicks, including for the SVMNat. The three studied systems of minimum ventilation allowed the birds to externalize their productive performance, with values close to the ones considered satisfactory for all evaluated parameters, in accordance with the Brazilian aviculture standards.
Resumo:
The air dry-bulb temperature (t db),as well as the black globe humidity index (BGHI), exert great influence on the development of broiler chickens during their heating phase. Therefore, the aim of this study was to analyze the structure and the magnitude of the t db and BGHI spatial variability, using geostatistics tools such as semivariogram analysis and also producing kriging maps. The experiment was conducted in the west mesoregion of the states of Minas Gerais in 2010, in a commercial broiler house with heating system consisting of two furnaces that heat the air indirectly, in the firsts 14 days of the birds' life. The data were registered at intervals of five minutes in the period from 8 a.m. to 10 a.m. The variables were evaluated by variograms fitted by residual maximum likelihood (REML) testing the Spherical and Exponential models. Kriging maps were generated based on the best model used to fit the variogram. It was possible to characterize the variability of the t db and BGHI, which allowed observing the spatial dependence by using geostatistics techniques. In addition, the use of geostatistics and distribution maps made possible to identify problems in the heating system in regions inside the broiler house that may harm the development of chicks.
Resumo:
The air included in droplets generated by spray nozzles directly int0erferes in transport, deposition and retention of the droplets after its impact on the target. The objective of this study was to analyze the interference of adjuvants in the amount of air included in droplets generated by spray nozzles. The treatments were composed by four spray solutions containing mineral oil, vegetable oil, surfactant and water, and three spray nozzles, two air induction type and one pre-orifice. The air included was calculated by the difference between the volume of spray mix (air plus liquid) and only the liquid, which was made by means of sprayed samples captured in a funnel and collected in a graduated cylinder. The surface tension was estimated by the gravimetric method using a precision scale and a graduated pipette. The surfactant provided the largest percentage of air included in the spray. For the surface tension, the mineral oil and the surfactant had the lowest values. It was concluded that the use of adjuvants had a direct influence on the percentage of air included. In addition, products with greater ability to reduce surface tension and to form homogeneous solutions provided the increase in the percentage of air included in the droplet.
Resumo:
The air-assisted ground spray is fairly widespread. However, due to the unpredictable weather conditions, the operational efficiency is impaired by stops on grounds of low humidity and high temperatures. The aim of this work was to assess an air humidification method and evaluate its impact on temperature and air humidity for the air curtain of the air-assisted sprayer. With respect to relative air humidity, it has increased in 6.59%, being the maximum change when inserting 1.92 L min-1. So, it is concluded that the pipeline humidification might significantly reduce temperature and enhance air humidity. The treatments performed in this study consisted of a varied flow of a humidity device, related to weather conditions. Temperature and relative air humidity were measured at 1.0 m height from right to left of middle point of the machine, corresponding to the end of the spray boom, in the middle and end of right spray boom. The readings were also performed at three different distances from the end of the pipeline and at 0.25 and 0.50 m from that to the soil. The results show that 0.48 L min-1 in the humidification system has promoted a better efficiency in reducing air-temperature, on average 2.52 ºC when compared to the non-humidified one.