Modeling of water/steam circulation in Circulating Fluidized Bed boiler


Autoria(s): Gavrilov, Anton
Data(s)

23/04/2013

23/04/2013

2010

Resumo

A distinctive design feature of steam boiler with natural circulation is the presence of the steam drum which plays a role of the separator of vapor from the flow of water-and-steam mixture coming into steam drum from the furnace tubes. Steam drum with unheated downcomer tubes, deducing from it, and riser (screen/furnace tubes) inside the furnace is a closed circulation loop in which movement of water (downcomer tubes) and water-and-steam mixture (riser tubes) is organized. The movement of the working fluid is appears due to occurrence of the natural pressure, determined by the difference in hydrostatic pressure and the mass of water and water-and-steam mixtures in downcomer and riser tubes and called the driving pressure of the natural circulation:

Identificador

http://www.doria.fi/handle/10024/90099

Idioma(s)

en

Palavras-Chave #rate of circulation #evaporation #natural water circulation loop #natural circulation #steam boiler
Tipo

Master's thesis

Diplomityö