928 resultados para Minimally fresh processed
Resumo:
BACKGROUND: Bleeding is a frequent complication during surgery. The intraoperative administration of blood products, including packed red blood cells, platelets and fresh frozen plasma (FFP), is often live saving. Complications of blood transfusions contribute considerably to perioperative costs and blood product resources are limited. Consequently, strategies to optimize the decision to transfuse are needed. Bleeding during surgery is a dynamic process and may result in major blood loss and coagulopathy due to dilution and consumption. The indication for transfusion should be based on reliable coagulation studies. While hemoglobin levels and platelet counts are available within 15 minutes, standard coagulation studies require one hour. Therefore, the decision to administer FFP has to be made in the absence of any data. Point of care testing of prothrombin time ensures that one major parameter of coagulation is available in the operation theatre within minutes. It is fast, easy to perform, inexpensive and may enable physicians to rationally determine the need for FFP. METHODS/DESIGN: The objective of the POC-OP trial is to determine the effectiveness of point of care prothrombin time testing to reduce the administration of FFP. It is a patient and assessor blind, single center randomized controlled parallel group trial in 220 patients aged between 18 and 90 years undergoing major surgery (any type, except cardiac surgery and liver transplantation) with an estimated blood loss during surgery exceeding 20% of the calculated total blood volume or a requirement of FFP according to the judgment of the physicians in charge. Patients are randomized to usual care plus point of care prothrombin time testing or usual care alone without point of care testing. The primary outcome is the relative risk to receive any FFP perioperatively. The inclusion of 110 patients per group will yield more than 80% power to detect a clinically relevant relative risk of 0.60 to receive FFP of the experimental as compared with the control group. DISCUSSION: Point of care prothrombin time testing in the operation theatre may reduce the administration of FFP considerably, which in turn may decrease costs and complications usually associated with the administration of blood products. TRIAL REGISTRATION: NCT00656396.
Resumo:
Ventral mesencephalon (VM) of fetal rat and human origin grown as free-floating roller-tube (FFRT) cultures can survive subsequent grafting to the adult rat striatum. To further explore the functional efficacy of such grafts, embryonic day 13 ventral mesencephalic tissue was grafted either after 7 days in culture or directly as dissociated cell suspensions, and compared with regard to neuronal survival and ability to normalize rotational behavior in adult rats with unilateral 6-hydroxydopamine (6-OHDA) lesions. Other lesioned rats received injections of cell-free medium and served as controls. The amphetamine-induced rotational behavior of all 6-OHDA-lesioned animals was monitored at various time points from 18 days before transplantation and up to 80 days after transplantation. Tyrosine hydroxylase (TH) immunostaining of the histologically processed brains served to assess the long-term survival of grafted dopaminergic neurons and to correlate that with the behavioral effects. Additional cultures and acutely prepared explants were also fixed and stored for histological investigation in order to estimate the loss of dopaminergic neurons in culture and after transplantation. Similar behavioral improvements in terms of significant reductions in amphetamine-induced rotations were observed in rats grafted with FFRT cultures (127%) and rats grafted with cell suspensions (122%), while control animals showed no normalization of rotational behavior. At 84 days after transplantation, there were similar numbers of TH-immunoreactive (TH-ir) neurons in grafts of cultured tissue (775 +/- 98, mean +/- SEM) and grafts of fresh, dissociated cell suspension (806 +/- 105, mean +/- SEM). Cell counts in fresh explants, 7-day-old cultures, and grafted cultures revealed a 68.2% loss of TH-ir cells 7 days after explantation, with an additional 23.1% loss after grafting, leaving 8.7% of the original number of TH-ir cells in the intracerebral grafts. This is to be compared with a survival rate of 9.1% for the TH-ir cells in the cell-suspension grafts. Immunostaining for the calcium-binding proteins calretinin, calbindin, and parvalbumin showed no differences in the neuronal expression of these proteins between the two graft types. In conclusion, we found comparable dopaminergic cell survival and functional effects of tissue-culture grafts and cell-suspension grafts, which currently is the type of graft most commonly used for experimental and clinical grafting. In this sense the result is promising for the development of an effective in vitro storage of fetal nigral tissue, which at the same time would allow neuroprotective and neurotrophic treatment prior to intracerebral transplantation.
Resumo:
The development of the Internet has made it possible to transfer data ‘around the globe at the click of a mouse’. Especially fresh business models such as cloud computing, the newest driver to illustrate the speed and breadth of the online environment, allow this data to be processed across national borders on a routine basis. A number of factors cause the Internet to blur the lines between public and private space: Firstly, globalization and the outsourcing of economic actors entrain an ever-growing exchange of personal data. Secondly, the security pressure in the name of the legitimate fight against terrorism opens the access to a significant amount of data for an increasing number of public authorities.And finally,the tools of the digital society accompany everyone at each stage of life by leaving permanent individual and borderless traces in both space and time. Therefore, calls from both the public and private sectors for an international legal framework for privacy and data protection have become louder. Companies such as Google and Facebook have also come under continuous pressure from governments and citizens to reform the use of data. Thus, Google was not alone in calling for the creation of ‘global privacystandards’. Efforts are underway to review established privacy foundation documents. There are similar efforts to look at standards in global approaches to privacy and data protection. The last remarkable steps were the Montreux Declaration, in which the privacycommissioners appealed to the United Nations ‘to prepare a binding legal instrument which clearly sets out in detail the rights to data protection and privacy as enforceable human rights’. This appeal was repeated in 2008 at the 30thinternational conference held in Strasbourg, at the 31stconference 2009 in Madrid and in 2010 at the 32ndconference in Jerusalem. In a globalized world, free data flow has become an everyday need. Thus, the aim of global harmonization should be that it doesn’t make any difference for data users or data subjects whether data processing takes place in one or in several countries. Concern has been expressed that data users might seek to avoid privacy controls by moving their operations to countries which have lower standards in their privacy laws or no such laws at all. To control that risk, some countries have implemented special controls into their domestic law. Again, such controls may interfere with the need for free international data flow. A formula has to be found to make sure that privacy at the international level does not prejudice this principle.
Resumo:
Delivering cochlear implants through a minimally invasive tunnel (1.8 mm in diameter) from the mastoid surface to the inner ear is referred to as direct cochlear access (DCA). Based on cone beam as well as micro-computed tomography imaging, this in vitro study evaluates the feasibility and efficacy of manual cochlear electrode array insertions via DCA. Free-fitting electrode arrays were inserted in 8 temporal bone specimens with previously drilled DCA tunnels. The insertion depth angle, procedural time, tunnel alignment as well as the inserted scala and intracochlear trauma were assessed. Seven of the 8 insertions were full insertions, with insertion depth angles higher than 520°. Three cases of atraumatic scala tympani insertion, 3 cases of probable basilar membrane rupture and 1 case of dislocation into the scala vestibuli were observed (1 specimen was damaged during extraction). Manual electrode array insertion following a DCA procedure seems to be feasible and safe and is a further step toward clinical application of image-guided otological microsurgery.
Resumo:
Lean, finely textured beef (LFTB) is a lean product derived from beef-fat trimmings. Characterization of LFTB showed that, while it is high in total protein, the LFTB contains more serum and connective tissue proteins and less myofibrillar proteins than muscle meat. Because of the protein differences, LFTB has less functionality in processed meats, resulting in lower yields and softer texture. Appropriate use of sodium chloride, sodium tripolyphosphate, k-carrageenan, or isolated soy protein achieved desired stability and yields in frankfurters with FTLB. The softer texture may be used to advantage in high-protein, low-fat meat products where excessive toughness or firmness is often a problem.
Resumo:
The effects of electron beam irradiation, anaerobic packaging, and storage times on the aroma of raw ground beef patties were investigated. Patties were coarse ground at three days postmortem, and then fine ground and packaged at three, six, and nine days postmortem. Patties were irradiated immediately after packaging, or three days after packaging at 2 kGy, and then stored at 2.5 °C ñ1.5 °C for four days. Non-irradiated controls were held under similar conditions. After four days of storage for each postmortem time (three, six, and nine days), sensory aroma evaluations were performed on all samples. Irradiated and non-irradiated patties with the shortest postmortem storage times had the most desirable aroma scores. Controls had significantly (p £ .05) more desirable aroma scores than irradiated patties.
Resumo:
In the field of thrombosis and haemostasis, many preanalytical variables influence the results of coagulation assays and measures to limit potential results variations should be taken. To our knowledge, no paper describing the development and maintenance of a haemostasis biobank has been previously published. Our description of the biobank of the Swiss cohort of elderly patients with venous thromboembolism (SWITCO65+) is intended to facilitate the set-up of other biobanks in the field of thrombosis and haemostasis. SWITCO65+ is a multicentre cohort that prospectively enrolled consecutive patients aged ≥65 years with venous thromboembolism at nine Swiss hospitals from 09/2009 to 03/2012. Patients will be followed up until December 2013. The cohort includes a biobank with biological material from each participant taken at baseline and after 12 months of follow-up. Whole blood from all participants is assayed with a standard haematology panel, for which fresh samples are required. Two buffy coat vials, one PAXgene Blood RNA System tube and one EDTA-whole blood sample are also collected at baseline for RNA/DNA extraction. Blood samples are processed and vialed within 1 h of collection and transported in batches to a central laboratory where they are stored in ultra-low temperature archives. All analyses of the same type are performed in the same laboratory in batches. Using multiple core laboratories increased the speed of sample analyses and reduced storage time. After recruiting, processing and analyzing the blood of more than 1,000 patients, we determined that the adopted methods and technologies were fit-for-purpose and robust.
Resumo:
What's known on the subject? and What does the study add? The EndoSew® prototype was first tested in a porcine model several years ago. The investigators found it both simple to master and reliable, its greatest advantage being a 2.4-fold time saving compared with straight laparoscopic suturing. In addition to that publication, there is a single case report describing the performance of an open EndoSew® suture to close parts (16 cm) of an ileal neobladder. The time for suturing the 16 cm ileum was 25 min, which is in line with our experience. The knowledge on this subject is limited to these two publications. We report on the first consecutive series of ileal conduits performed in humans using the novel prototype sewing device EndoSew®. The study shows that the beginning and the end of the suture process represent the critical procedural steps. It also shows that, overall, the prototype sewing machine has the potential to facilitate the intracorporeal suturing required in reconstructive urology for construction of urinary diversions. Objective To evaluate the feasibility and safety of the novel prototype sewing device EndoSew® in placing an extracorporeal resorbable running suture for ileal conduits. Patients and Methods We conducted a prospective single-centre pilot study of 10 consecutive patients undergoing ileal conduit, in whom the proximal end of the ileal conduit was closed extracorporeally using an EndoSew® running suture. The primary endpoint was the safety of the device and the feasibility of the sewing procedure which was defined as a complete watertight running suture line accomplished by EndoSew® only. Watertightness was assessed using methylene blue intraoperatively and by loopography on postoperative days 7 and 14. Secondary endpoints were the time requirements and complications ≤30 days after surgery. Results A complete EndoSew® running suture was feasible in nine patients; the suture had to be abandoned in one patient because of mechanical failure. In three patients, two additional single freehand stitches were needed to anchor the thread and to seal tiny leaks. Consequently, all suture lines in 6/10 patients were watertight with EndoSew® suturing alone and in 10/10 patients after additional freehand stitches. The median (range) sewing time was 5.5 (3–10) min and the median (range) suture length was 4.5 (2–5.5) cm. There were no suture-related complications. Conclusions The EndoSew® procedure is both feasible and safe. After additional freehand stitches in four patients all sutures were watertight. With further technical refinements, EndoSew® has the potential to facilitate the intracorporeal construction of urinary diversions.
Resumo:
BACKGROUND While surgical navigation offers the opportunity to accurately place an acetabular component, questions remain as to the best goal for acetabular component positioning in individual patients. Overall functional orientation of the pelvis after surgery is one of the most important variables for the surgeon to consider when determining the proper goal for acetabular component orientation. QUESTIONS/PURPOSES We measured the variation in pelvic tilt in 30 patients before THA and the effect of THA on pelvic tilt in the same patients more than a year after THA. METHODS Each patient had a CT study for CT-based surgical navigation and standing and supine radiographs before and after surgery. Pelvic tilt was calculated for each of the radiographs using a novel and validated two-dimensional/three-dimensional matching technique. RESULTS Mean supine pelvic tilt changed less than 2°, from 4.4° ± 6.4° (range, -7.7° to 20.8°) before THA to 6.3° ± 6.6° (range, -5.7° to 19.6°) after THA. Mean standing pelvic tilt changed less than 1°, from 1.5° ± 7.2° (range, -13.1° to 12.8°) before THA to 2.0° ± 8.3° (range, -12.3° to 16.8°) after THA. Preoperative pelvic tilt correlated with postoperative tilt in both the supine (r(2) = 0.75) and standing (r(2) = 0.87) positions. CONCLUSIONS In this population, pelvic tilt had a small and predictable change after surgery. However, intersubject variability of pelvic tilt was high, suggesting preoperative pelvic tilt should be considered when determining desired acetabular component positioning on a patient-specific basis.
Resumo:
The use of smaller surgical incisions has become popularized for total hip arthroplasty (THR) because of the potential benefits of shorter recovery and improved cosmetic appearance. However, an increased incidence of serious complications has been reported. To minimize the risks of minimally invasive approaches to THR, we have developed an experimental approach which enables us to evaluate risk factors in these procedures through cadaveric simulations performed within the laboratory. During cadaveric hip replacement procedures performed via posterior and antero-lateral mini-incisions, pressures developed between the wound edges and the retractors were approximately double those recorded during conventional hip replacement using Charnley retractors (p < 0.01). In MIS procedures performed via the dual-incision approach, lack of direct visualisation of the proximal femur led to misalignment of broaches and implants with increased risk of cortical fracture during canal preparation and implant insertion. Cadaveric simulation of surgical procedures allows surgeons to measure variables affecting the technical success of surgery and to master new procedures without placing patients at risk.
Resumo:
OBJECTIVE: To test a new tiny-tipped intraoperative diagnostic tool that was designed to provide the surgeon with reliable stiffness data on the motion segment during microdiscectomy. A decrease in stiffness after nuclectomy and a measurable influence of muscle tension were assumed. If the influence of muscle tension on the motion segment could at least be ruled out, there should be no difference with regard to stiffness between women and men. If these criteria are met, this new intraoperative diagnostic tool could be used in further studies for objective decision-making regarding additional stabilization systems after microdiscectomy. METHODS: After evaluation of the influence of muscle relaxation during in vivo measurements with a spinal spreader between the spinous processes, 21 motion segments were investigated in 21 patients. Using a standardized protocol, including quantified muscle relaxation, spinal stiffness was measured before laminotomy and after nuclectomy. RESULTS: The decrease in stiffness after microdiscectomy was highly significant. There were no statistically significant differences between men and women. The average stiffness value before discectomy was 33.7 N/mm, and it decreased to 25.6 N/mm after discectomy. The average decrease in stiffness was 8.1 N/mm (24%). CONCLUSION: In the moderately degenerated spine, stiffness decreases significantly after microdiscectomy. Control for muscle relaxation is essential when measuring in vivo spinal stiffness. The new spinal spreader was found to provide reliable data. This spreader could be used in further studies for objective decision-making about additional stabilization systems after microdiscectomy.