899 resultados para Definite


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background—Long-term comparative data of first-generation drug-eluting stents are scarce. We investigated clinical and angiographic outcomes of sirolimus-eluting (SES) and paclitaxel-eluting stents (PES) at 5 years as part of the Sirolimus-Eluting Versus Paclitaxel-Eluting Stents for Coronary Revascularization (SIRTAX) LATE study. Methods and Results—A total of 1012 patients were randomly assigned to SES or PES. Repeat angiography was completed in 444 of 1012 patients (43.8%) at 5 years. Major adverse cardiac events occurred in 19.7% of SES- and 21.4% of PES-treated patients (hazard ratio, 0.89; 95% confidence interval, 0.68 to 1.17; P=0.39) at 5 years. There were no differences between SES and PES in terms of cardiac death (5.8% versus 5.7%; P=0.35), myocardial infarction (6.6% versus 6.9%; P=0.51), and target lesion revascularization (13.1% versus 15.1%; P=0.29). Between 1 and 5 years, the annual rate of target lesion revascularization was 2.0% (95% confidence interval, 1.4% to 2.6%) for SES and 1.4% (95% confidence interval, 0.9% to 2.0%) for PES. Among patients undergoing paired angiography at 8 months and 5 years, delayed lumen loss amounted to 0.37±0.73 mm for SES and 0.29±0.59 mm for PES (P=0.32). The overall rate of definite stent thrombosis was 4.6% for SES and 4.1% for PES (P=0.74), and very late definite stent thrombosis occurred at an annual rate of 0.65% (95% confidence interval, 0.40% to 0.90%). Conclusions—Long-term follow-up of first-generation drug-eluting stents shows no significant differences in clinical and angiographic outcomes between SES and PES. The continuous increase in late lumen loss in conjunction with the ongoing risk of very late stent thrombosis suggests that vascular healing remains incomplete up to 5 years after implantation of first-generation drug-eluting stents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives This study sought to compare the unrestricted use of everolimus-eluting stents (EES) with sirolimus-eluting stents (SES) in patients undergoing percutaneous coronary intervention. Background It is unclear whether there are differences in safety and efficacy between EES and SES during long-term follow-up. Methods Using propensity score matching, clinical outcome was compared among 1,342 propensity score–matched pairs of patients treated with EES and SES. The primary outcome was a composite of death, MI, and target vessel revascularization. Results The median follow-up was 1.5 years with a maximum of 3 years. The primary outcome occurred in 14.9% of EES- and 18.0% of SES-treated patients up to 3 years (hazard ratio [HR]: 0.83, 95% confidence interval [CI]: 0.68 to 1.00, p = 0.056). All-cause mortality (6.0% vs. 6.5%, HR: 0.92, 95% CI: 0.68 to 1.25, p = 0.59) was similar, risks of myocardial infarction (MI) (3.3% vs. 5.0%, HR: 0.62, 95% CI: 0.42 to 0.92, p = 0.017), and target vessel revascularization (7.0% vs. 9.6%, HR: 0.75, 95% CI: 0.57 to 0.99, p = 0.039) were lower with EES than SES. Definite stent thrombosis (ST) (HR: 0.30, 95% CI: 0.12 to 0.75, p = 0.01) was less frequent among patients treated with EES. The reduced rate of MI with EES was explained in part by the lower risk of definite ST and the corresponding decrease in events associated with ST (HR: 0.25, 95% CI: 0.08 to 0.75, p = 0.013). Conclusions The unrestricted use of EES appears to be associated with improved clinical long-term outcome compared with SES. Differences in favor of EES are driven in part by a lower risk of MI associated with ST.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: We aimed at comparing the long term clinical outcome of SES and PES in routine clinical practice. Background: Although sirolimus-eluting stents (SES) more effectively reduce neointimal hyperplasia than paclitaxel-eluting stents (PES), uncertainty prevails whether this difference translates into differences in clinical outcomes outside randomized controlled trials with selected patient populations and protocol-mandated angiographic follow-up. Methods: Nine hundred and four consecutive patients who underwent implantation of a drug-eluting stent between May 2004 and February 2005: 467 patients with 646 lesions received SES, 437 patients with 600 lesions received PES. Clinical follow-up was obtained at 2 years without intervening routine angiographic follow-up. The primary endpoint was a composite of death, myocardial infarction (MI), or target vessel revascularization (TVR). Results: At 2 years, the primary endpoint was less frequent with SES (12.9%) than PES (17.6%, HR = 0.70, 95% CI 0.50–0.98, P = 0.04). The difference in favor of SES was largely driven by a lower rate of target lesion revascularisation (TLR; 4.1% vs. 6.9%, P = 0.05), whereas rates of death (6.4% vs. 7.6%, P = 0.49), MI (1.9% vs. 3.2%, P = 0.21), or definite stent thrombosis (0.6% vs. 1.4%, P = 0.27) were similar for both stent types. The benefit regarding reduced rates of TLR was significant in nondiabetic (3.6% vs. 7.1%, P = 0.04) but not in diabetic patients (5.6% vs. 6.1%, P = 0.80). Conclusions: SES more effectively reduced the need for repeat revascularization procedures than PES when used in routine clinical practice. The beneficial effect is maintained up to 2 years and may be less pronounced in diabetic patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gallup (this issue) believes that our recent review on the function of yawning (Guggisberg et al., 2010) is unbalanced and that it ignores evidence for his thermoregulation hypothesis. Here we address these criticisms and show them to be untenable. While we never claimed that the social hypothesis of yawning has "definite experimental support", we emphasize the importance of experimental evidence for specific effects of yawns when considering why we yawn. The only specific effect of yawning that could be demonstrated so far is its contagiousness in humans, some non-human primates, and possibly dogs, whereas all studies investigating physiological consequences of yawns were unable to observe specific yawn-induced effects in the individual of any species. The argument that from an evolutionary perspective, yawns must have a "primitive" physiological function arises from imprecise reasoning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective Femoroacetabular impingement may be a risk factor for hip osteoarthritis in men. An underlying hip deformity of the cam type is common in asymptomatic men with nondysplastic hips. This study was undertaken to examine whether hip deformities of the cam type are associated with signs of hip abnormality, including labral lesions and articular cartilage damage, detectable on magnetic resonance imaging (MRI). Methods In this cross-sectional, population-based study in asymptomatic young men, 1,080 subjects underwent clinical examination and completed a self-report questionnaire. Of these subjects, 244 asymptomatic men with a mean age of 19.9 years underwent MRI. All MRIs were read for cam-type deformities, labral lesions, cartilage thickness, and impingement pits. The relationship between cam-type deformities and signs of joint damage were examined using logistic regression models adjusted for age and body mass index. Odds ratios (ORs) and 95% confidence intervals (95% CIs) were determined. Results Sixty-seven definite cam-type deformities were detected. These deformities were associated with labral lesions (adjusted OR 2.77 [95% CI 1.31, 5.87]), impingement pits (adjusted OR 2.9 [95% CI 1.43, 5.93]), and labral deformities (adjusted OR 2.45 [95% CI 1.06, 5.66]). The adjusted mean difference in combined anterosuperior femoral and acetabular cartilage thickness was −0.19 mm (95% CI −0.41, 0.02) lower in those with cam-type deformities compared to those without. Conclusion Our findings indicate that the presence of a cam-type deformity is associated with MRI-detected hip damage in asymptomatic young men.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background The effectiveness of durable polymer drug-eluting stents comes at the expense of delayed arterial healing and subsequent late adverse events such as stent thrombosis (ST). We report the 4 year follow-up of an assessment of biodegradable polymer-based drug-eluting stents, which aim to improve safety by avoiding the persistent inflammatory stimulus of durable polymers. Methods We did a multicentre, assessor-masked, non-inferiority trial. Between Nov 27, 2006, and May 18, 2007, patients aged 18 years or older with coronary artery disease were randomly allocated with a computer-generated sequence to receive either biodegradable polymer biolimus-eluting stents (BES) or durable polymer sirolimus-eluting stents (SES; 1:1 ratio). The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation (TVR); patients were followed-up for 4 years. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00389220. Findings 1707 patients with 2472 lesions were randomly allocated to receive either biodegradable polymer BES (857 patients, 1257 lesions) or durable polymer SES (850 patients, 1215 lesions). At 4 years, biodegradable polymer BES were non-inferior to durable polymer SES for the primary endpoint: 160 (18·7%) patients versus 192 (22·6%) patients (rate ratios [RR] 0·81, 95% CI 0·66–1·00, p for non-inferiority <0·0001, p for superiority=0·050). The RR of definite ST was 0·62 (0·35–1·08, p=0·09), which was largely attributable to a lower risk of very late definite ST between years 1 and 4 in the BES group than in the SES group (RR 0·20, 95% CI 0·06–0·67, p=0·004). Conversely, the RR of definite ST during the first year was 0·99 (0·51–1·95; p=0·98) and the test for interaction between RR of definite ST and time was positive (pinteraction=0·017). We recorded an interaction with time for events associated with ST but not for other events. For primary endpoint events associated with ST, the RR was 0·86 (0·41–1·80) during the first year and 0·17 (0·04–0·78) during subsequent years (pinteraction=0·049). Interpretation Biodegradable polymer BES are non-inferior to durable polymer SES and, by reducing the risk of cardiac events associated with very late ST, might improve long-term clinical outcomes for up to 4 years compared with durable polymer SES. Funding Biosensors Europe SA, Switzerland.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives This study sought to compare the efficacy of passive stent coating with titanium-nitride-oxide (TiNO) with drug-eluting stents releasing zotarolimus (ZES) (Endeavor, Medtronic, Minneapolis, Minnesota). Background Stent coating with TiNO has been shown to reduce restenosis compared with bare-metal stents in experimental and clinical studies. Methods In an assessor-blind noninferiority study, 302 patients undergoing percutaneous coronary intervention were randomized to treatment with TiNO or ZES. The primary endpoint was in-stent late loss at 6 to 8 months, and analysis was by intention to treat. Results Both groups were well balanced with respect to baseline clinical and angiographic characteristics. The TiNO group failed to reach the pre-specified noninferiority margin for the primary endpoint (in-stent late loss: 0.64 ± 0.61 mm vs. 0.47 ± 0.48 mm, difference: 0.16, upper 1-sided 95% confidence interval [CI]: 0.26; pnoninferiority = 0.54), and subsequent superiority testing was in favor of ZES (psuperiority = 0.02). In-segment binary restenosis was lower with ZES (11.1%) than with TiNO (20.5%; psuperiority = 0.04). A stratified analysis of the primary endpoint found particularly pronounced differences between stents among diabetic versus nondiabetic patients (0.90 ± 0.69 mm vs. 0.39 ± 0.38 mm; pinteraction = 0.04). Clinical outcomes showed a similar rate of death (0.7% vs. 0.7%; p = 1.00), myocardial infarction (5.3% vs. 6.7%; p = 0.60), and major adverse cardiac events (21.1% vs. 18.0%, hazard ratio: 1.19, 95% CI: 0.71 to 2.00; p = 0.50) at 1 year. There were no differences in rates of definite or probable stent thrombosis (0.7% vs. 0%; p = 0.51) at 1 year. Conclusions Compared with TiNO, ZES was superior with regard to late loss and binary restenosis. The concept of passive stent coating with TiNO remains inferior to drug-eluting stent technology in reducing restenosis. ([TIDE] Randomized Trial Comparing Titan Stent With Zotarolimus-Eluting Stent: NCT00492908)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: The current study reports clinical outcomes at three year follow-up of the LEADERS clinical trial which was the first all-comers trial comparing a new generation biodegradable polymer biolimus drug-eluting stent (BES) with the first generation permanent polymer sirolimus-eluting stent (SES). Methods and results: One thousand seven hundred and seven patients were randomised to unrestricted use of BES (n=857) or SES (n=850) in an all-comers population. Three year follow-up was available in 95% of the patients, 812 treated with BES and 809 treated with SES. At three years, BES remains non-inferior to SES for the primary endpoint of major adverse cardiac events (composite of cardiac death, myocardial infarction (MI), or clinically-indicated target vessel revascularisation (CI-TVR) (BES 15.7% versus SES 19%; HR 0.82 CI 0.65-1.03; p=0.09). The MACE Kaplan Meier event curves increasingly diverge with the difference in events increasing from 1.4% to 2.4% and 3.3% at 1, 2 and 3 years, respectively in favour of BES. The rate of cardiac death was non-significantly lower 4.2% versus 5.2% (HR=0.81 CI 0.52-1.26; p=0.34) and the rate of myocardial infarction was equivalent 7.2% versus 7.1% (HR 1.01 CI 0.70-1.44; p=0.97) for BES versus SES, respectively. Thus BES was non-inferior to SES in all the safety endpoints. Clinically-indicated TVR occurred in 9.4% of BES treated patients versus 11.1% of SES treated patients (HR 0.84 CI 0.62-1.13; p=0.25). Rates of definite stent thrombosis were 2.2% for BES and 2.9% for SES (HR 0.78 CI 0.43-1.43; p=0.43), with the event rate increase of 0.2% from one to three years for BES and 0.9% for SES. For patients presenting with ST-elevation myocardial infarction BES was superior to SES in reducing MACE. Conclusions: The findings of the three year follow-up support the claim that the biodegradable polymer biolimus-eluting stent has equivalent safety and efficacy to permanent polymer sirolimus-eluting stent in an all-comers patient population. Its performance is superior in some subpopulations such as in ST-elevation MI patients and event rates for BES are overall lower than for SES with a trend toward increasing divergence of outcomes over three years. - See more at: http://www.pcronline.com/eurointervention/42nd_issue/125/#sthash.E5HhMQ4a.dpuf

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives This study sought to investigate safety and efficacy of biolimus-eluting stents (BES) with biodegradable polymer as compared with sirolimus-eluting stents (SES) with durable polymer through 2 years of follow-up. Background BES with a biodegradable polymer provide similar efficacy and safety as SES with a durable polymer at 9 months. Clinical outcomes beyond the period of biodegradation of the polymer used for drug release and after discontinuation of dual antiplatelet therapy are of particular interest. Methods A total of 1,707 patients were randomized to unrestricted use of BES (n = 857) or SES (n = 850) in an all-comers patient population. Results At 2 years, BES remained noninferior compared with SES for the primary endpoint, which was a composite of cardiac death, myocardial infarction, or clinically indicated target vessel revascularization (BES 12.8% vs. SES 15.2%, hazard ratio [HR]: 0.84, 95% confidence interval [CI]: 0.65 to 1.08, pnoninferiority < 0.0001, psuperiority = 0.18). Rates of cardiac death (3.2% vs. 3.9%, HR: 0.81, 95% CI: 0.49 to 1.35, p = 0.42), myocardial infarction (6.3% vs. 5.6%, HR: 1.12, 95% CI: 0.76 to 1.65, p = 0.56), and clinically indicated target vessel revascularization (7.5% vs. 8.6%, HR: 0.86, 95% CI: 0.62 to 1.20, p = 0.38) were similar for BES and SES. The rate of definite stent thrombosis through 2 years was 2.2% for BES and 2.5% for SES (p = 0.73). For the period between 1 and 2 years, event rates for definite stent thrombosis were 0.2% for BES and 0.5% for SES (p = 0.42). After discontinuation of dual antiplatelet therapy, no very late definite stent thrombosis occurred in the BES group. Conclusions At 2 years of follow-up, the unrestricted use of BES with a biodegradable polymer maintained a similar safety and efficacy profile as SES with a durable polymer. (Limus Eluted From a Durable Versus Erodable Stent Coating [LEADERS]; NCT00389220)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to assess the impact of body mass index (BMI) on clinical outcome of patients treated by percutaneous coronary intervention (PCI) using drug-eluting stents. Patients were stratified according to BMI as normal (<25 kg/m(2)), overweight (25 to 30 kg/m(2)), or obese (>30 kg/m(2)). At 5-year follow-up all-cause death, myocardial infarction, clinically justified target vessel revascularization (TVR), and definite stent thrombosis were assessed. A complete dataset was available in 7,427 patients, of which 45%, 22%, and 33% were classified according to BMI as overweight, obese, and normal, respectively. Mean age of patients was significantly older in those with a normal BMI (p <0.05). Incidence of diabetes mellitus, hypertension, and dyslipidemia increased as BMI increased (p <0.05). Significantly higher rates of TVR (15.3% vs 12.8%, p = 0.02) and early stent thrombosis (1.5% vs 0.9%, p = 0.04) were observed in the obese compared to the normal BMI group. No significant difference among the 3 BMI groups was observed for the composite of death/myocardial infarction/TVR or for definite stent thrombosis at 5 years, whereas the normal BMI group was at higher risk for all-cause death at 5 years (obese vs normal BMI, hazard ratio 0.74, confidence interval 0.53 to 0.99, p = 0.05; overweight vs normal BMI, hazard ratio 0.73, confidence interval 0.59 to 0.94, p = 0.01) in the multivariate Cox proportional hazard model. Age resulted in a linearly dependent covariate with BMI in the all-cause 5-year mortality multivariate model (p = 0.001). In conclusion, the "obesity paradox" observed in 5-year all-cause mortality could be explained by the higher rate of elderly patients in the normal BMI group and the existence of colinearity between BMI and age. However, obese patients had a higher rate of TVR and early stent thrombosis and a higher rate of other risk factors such as diabetes mellitus, hypertension, and hypercholesterolemia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background— The age, creatinine, and ejection fraction (ACEF) score (age/left ventricular ejection fraction+1 if creatinine >2.0 mg/dL) has been established as an effective predictor of clinical outcomes in patients undergoing elective coronary artery bypass surgery; however, its utility in “all-comer” patients undergoing percutaneous coronary intervention is yet unexplored. Methods and Results— The ACEF score was calculated for 1208 of the 1707 patients enrolled in the LEADERS trial. Post hoc analysis was performed by stratifying clinical outcomes at the 1-year follow-up according to ACEF score tertiles: ACEFlow ≤1.0225, 1.0225< ACEFmid ≤1.277, and ACEFhigh >1.277. At 1-year follow-up, there was a significantly lower number of patients with major adverse cardiac event–free survival in the highest tertile of the ACEF score (ACEFlow=92.1%, ACEFmid=89.5%, and ACEFhigh=86.1%; P=0.0218). Cardiac death was less frequent in ACEFlow than in ACEFmid and ACEFhigh (0.7% vs 2.2% vs 4.5%; hazard ratio=2.22, P=0.002) patients. Rates of myocardial infarction were significantly higher in patients with a high ACEF score (6.7% for ACEFhigh vs 5.2% for ACEFmid and 2.5% for ACEFlow; hazard ratio=1.6, P=0.006). Clinically driven target-vessel revascularization also tended to be higher in the ACEFhigh group, but the difference among the 3 groups did not reach statistical significance. The rate of composite definite, possible, and probable stent thrombosis was also higher in the ACEFhigh group (ACEFlow=1.2%, ACEFmid=3.5%, and ACEFhigh=6.2%; hazard ratio=2.04, P<0.001). Conclusions— ACEF score may be a simple way to stratify risk of events in patients treated with percutaneous coronary intervention with respect to mortality and risk of myocardial infarction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patients' reports of safety-related events and perceptions of safety can be a valuable source for hospitals. Patients of eight acute care hospitals in Switzerland were surveyed for safety-related events and concerns for safety. In workshops with hospitals areas for improvement were analyzed and priorities for change identified. To evaluate the benefit of the approach, semi-structured interviews were conducted with hospital risk managers. 3,983 patients returned the survey (55% response rate). 21.4% reported at least one definite safety event, and the mean number of 'definite' incidents per patient was 0.31 (95% CI=0.29 to 0.34). 3.2% were very concerned and 14.7% were somewhat concerned about medical errors and safety. Having experienced a safety-related event, younger age, length of stay, poor health and a poor education increased the probability of reporting concerns. With some exceptions, results confirmed the hospitals' a priori expectations regarding the strengths and weaknesses of their institutions. Risk managers emphasized the usability of results for their work and the special value of referring to the patient's perspective at their home institutions. A considerable fraction of patients subjectively experiences safety-related events and is concerned about safety. Patient-generated data introduced a new quality into the discussion of safety issues within hospitals, and some expected that patients' experiences and concerns could affect patient volumes. Though the study is limited by the short time horizon and the lack of follow-up, the results suggest that the described approach is feasible and can serve as a supplemental tool for risk identification and management.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For as far back as human history can be traced, mankind has questioned what it means to be human. One of the most common approaches throughout Western culture's intellectual tradition in attempts to answering this question has been to compare humans with or against other animals. I argue that it was not until Charles Darwin's publication of The Descent of Man and Selection in Relation to Sex (1871) that Western culture was forced to seriously consider human identity in relation to the human/ nonhuman primate line. Since no thinker prior to Charles Darwin had caused such an identity crisis in Western thought, this interdisciplinary analysis of the history of how the human/ nonhuman primate line has been understood focuses on the reciprocal relationship of popular culture and scientific representations from 1871 to the Human Genome Consortium in 2000. Focusing on the concept coined as the "Darwin-Müller debate," representations of the human/ nonhuman primate line are traced through themes of language, intelligence, and claims of variation throughout the popular texts: Descent of Man, The Jungle Books (1894), Tarzan of the Apes (1914), and Planet of the Apes (1963). Additional themes such as the nature versus nurture debate and other comparative phenotypic attributes commonly used for comparison between man and apes are also analyzed. Such popular culture representations are compared with related or influential scientific research during the respective time period of each text to shed light on the reciprocal nature of Western intellectual tradition, popular notions of the human/ nonhuman primate line, and the development of the field of primatology. Ultimately this thesis shows that the Darwin-Müller debate is indeterminable, and such a lack of resolution makes man uncomfortable. Man's unsettled response and desire for self-knowledge further facilitates a continued search for answers to human identity. As the Human Genome Project has led to the rise of new debates, and primate research has become less anthropocentric over time, the mysteries of man's future have become more concerning than the questions of our past. The human/ nonhuman primate line is reduced to a 1% difference, and new debates have begun to overshadow the Darwin-Müller debate. In conclusion, I argue that human identity is best represented through the metaphor of evolution: both have an unknown beginning, both have an indeterminable future with no definite end, and like a species under the influence of evolution, what it means to be human is a constant, indeterminable process of change.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main goal of this project was to identity whether an imported system of social policy can be suitable for a host country, and if not why not. Romanian social policy concerning the mentally disabled represents a paradoxical situation in that while social policy is designed to ensure both an institutional structure and a juridical environment, in practice it is far from successful. The central question which Ms. Ciumageanu asked therefore was whether this failure was due to systemic factors, or whether the problem lay in reworking an imported social policy system to meet local needs. She took a comparative approach, also considering both the Scandinavian model of social policy, particularly the Danish model which has been adopted in Romania, and the Hungarian system, which has inherited a similar universal welfare system and perpetuated it to some extent. In order to verify her hypothesis, she also studied the transformation of the welfare system in Great Britain, which meant a shift from state responsibility towards community care. In all these she concentrated on two major aspects: the structural design within the different countries and, at a micro level, the societal response. Following her analyses of the various in the other countries concerned, Ms. Ciumageanu concluded that the major differences lie first in the difference between the stages of policy design. Here Denmark is the most advanced and Romania the most backwards. Denmark has a fairly elaborate infrastructure, Britain a system with may gaps to bridge, and Hungary and Romania are struggling with severe difficulties owing both to the inherited structure and the limits imposed by an inadequate GDP. While in Denmark and Britain, mental patients are integrated into an elaborate system of care, designed and administered by the state (in Denmark) or communities (in Britain), in Hungary and Romania, the state designs and fails to implement the policy and community support is minimal, partly due to the lack of a fully developed civil society. At the micro level the differences are similar. While in Denmark and Britain there is a consensus about the roles of the state and of civil societies (although at different levels in the two countries, with the state being more supportive in Denmark), in Romania and to a considerable extent in Hungary, civil society tends to expect too much from the state, which in its turn is withdrawing faster from its social roles than from its economic ones, generating a gap between the welfare state and the market economy and disadvantaging the expected transition from a welfare state to a welfare society and, implicitly, the societal response towards those mentally disabled persons in it. On an intermediate level, the factors influencing social policy as a whole were much the same for Hungary and Romania. Economic factors include the accumulated economic resources of both state and citizens, and the inherited pattern of redistribution, as well as the infrastructure; institutional resources include the role of the state and the efficiency of the state bureaucracy, the strength and efficiency of the state apparatus, political stability and the complexity of political democratisation, the introduction of market institutions, the strength of civil society and civic sector institutions. From the standpoint of the societal response, some factors were common to all countries, particularly the historical context, the collective and institutional memories and established patterns of behaviour. In the specific case of Romania, general structural and environmental factors - industrialisation and forced urbanisation - have had a definite influence on family structure, values and behavioural patterns. The analysis of Romanian social policy revealed several causes for failure to date. The first was the instability of the policy and the failure to consider the structural network involved in developing it, rather than just the results obtained. The second was the failure to take into account the relationship between the individual and the group in all its aspects, followed by the lack of active assistance for prevention, re-socialisation or professional integration of persons with mental disabilities. Finally, the state fails to recognise its inability to support an expensive psychiatric enterprise and does not provide any incentive to the private sector. This creates tremendous social costs for both the state and the individual. NGOs working in the field in Romania have been somewhat more successful but are still limited by their lack of funding and personnel and the idea of a combined system is as yet utopian in the circumstances in the country.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The protection of the fundamental human values (life, bodily integrity, human dignity, privacy) becomes imperative with the rapid progress in modern biotechnology, which can result in major alterations in the genetic make-up of organisms. It has become possible to insert human genes into pigs so that their internal organs coated in human proteins are more suitable for transplantation into humans (xenotransplantation), and micro-organisms that cam make insulin have been created, thus changing the genetic make-up of humans. At the end of the 1980s, the Central and Eastern European (CEE) countries either initiated new legislation or started to amend existing laws in this area (clinical testing of drugs, experiments on man, prenatal genetic diagnosis, legal protection of the embryo/foetus, etc.). The analysis here indicates that the CEE countries have not sufficiently adjusted their regulations to the findings of modern biotechnology, either because of the relatively short period they have had to do so, or because there are no definite answers to the questions which modern biotechnology has raised (ethical aspects of xenotransplantation, or of the use of live-aborted embryonic or foetal tissue in neuro-transplantation, etc.). In order to harmonise the existing regulations in CEE countries with respect to the EU and supranational contexts, two critical issues should be taken into consideration. The first is the necessity for CEE countries to recognise the place of humans within the achievements of modern biotechnology (a broader affirmation of the principle of autonomy, an explicit ban on the violation of the genetic identity of either born or unborn life, etc.). The second concerns the definition of the status of different biotechnological procedures and their permissibility (gene therapy, therapeutic genomes, xenotransplantation, etc.). The road towards such answers may be more easily identified once all CEE countries become members of the Council of Europe and express their wish to join the EU, which in turn presupposes taking over the entire body of EU legislation.