The three year follow-up of the randomised "all-comers" trial of a biodegradable polymer biolimus-eluting stent versus permanent polymer sirolimus-eluting stent (LEADERS)


Autoria(s): Wykrzykowska, Joanna; Serruys, Patrick; Buszman, Pawel; Linke, Axel; Ischinger, Thomas; Klauss, Volker; Eberli, Franz; Corti, Roberto; Wijns, William; Morice, Marie-Claude; Di Mario, Carlo; Van Geuns, Robert-Jan; Van Es, Gerrit-Anne; Juni, Peter; Windecker, Stephan
Data(s)

2011

Resumo

Aims: The current study reports clinical outcomes at three year follow-up of the LEADERS clinical trial which was the first all-comers trial comparing a new generation biodegradable polymer biolimus drug-eluting stent (BES) with the first generation permanent polymer sirolimus-eluting stent (SES). Methods and results: One thousand seven hundred and seven patients were randomised to unrestricted use of BES (n=857) or SES (n=850) in an all-comers population. Three year follow-up was available in 95% of the patients, 812 treated with BES and 809 treated with SES. At three years, BES remains non-inferior to SES for the primary endpoint of major adverse cardiac events (composite of cardiac death, myocardial infarction (MI), or clinically-indicated target vessel revascularisation (CI-TVR) (BES 15.7% versus SES 19%; HR 0.82 CI 0.65-1.03; p=0.09). The MACE Kaplan Meier event curves increasingly diverge with the difference in events increasing from 1.4% to 2.4% and 3.3% at 1, 2 and 3 years, respectively in favour of BES. The rate of cardiac death was non-significantly lower 4.2% versus 5.2% (HR=0.81 CI 0.52-1.26; p=0.34) and the rate of myocardial infarction was equivalent 7.2% versus 7.1% (HR 1.01 CI 0.70-1.44; p=0.97) for BES versus SES, respectively. Thus BES was non-inferior to SES in all the safety endpoints. Clinically-indicated TVR occurred in 9.4% of BES treated patients versus 11.1% of SES treated patients (HR 0.84 CI 0.62-1.13; p=0.25). Rates of definite stent thrombosis were 2.2% for BES and 2.9% for SES (HR 0.78 CI 0.43-1.43; p=0.43), with the event rate increase of 0.2% from one to three years for BES and 0.9% for SES. For patients presenting with ST-elevation myocardial infarction BES was superior to SES in reducing MACE. Conclusions: The findings of the three year follow-up support the claim that the biodegradable polymer biolimus-eluting stent has equivalent safety and efficacy to permanent polymer sirolimus-eluting stent in an all-comers patient population. Its performance is superior in some subpopulations such as in ST-elevation MI patients and event rates for BES are overall lower than for SES with a trend toward increasing divergence of outcomes over three years. - See more at: http://www.pcronline.com/eurointervention/42nd_issue/125/#sthash.E5HhMQ4a.dpuf

Formato

application/pdf

Identificador

http://boris.unibe.ch/7211/1/Wykrzykowska%20EuroIntervention%202011_p789.pdf

Wykrzykowska, Joanna; Serruys, Patrick; Buszman, Pawel; Linke, Axel; Ischinger, Thomas; Klauss, Volker; Eberli, Franz; Corti, Roberto; Wijns, William; Morice, Marie-Claude; Di Mario, Carlo; Van Geuns, Robert-Jan; Van Es, Gerrit-Anne; Juni, Peter; Windecker, Stephan (2011). The three year follow-up of the randomised "all-comers" trial of a biodegradable polymer biolimus-eluting stent versus permanent polymer sirolimus-eluting stent (LEADERS). EuroIntervention, 7(7), pp. 789-795. Toulouse: Europa Digital & Publishing 10.4244/EIJV7I7A125 <http://dx.doi.org/10.4244/EIJV7I7A125>

doi:10.7892/boris.7211

info:doi:10.4244/EIJV7I7A125

info:pmid:22027687

urn:issn:1774-024X

Idioma(s)

eng

Publicador

Europa Digital & Publishing

Relação

http://boris.unibe.ch/7211/

Direitos

info:eu-repo/semantics/openAccess

Fonte

Wykrzykowska, Joanna; Serruys, Patrick; Buszman, Pawel; Linke, Axel; Ischinger, Thomas; Klauss, Volker; Eberli, Franz; Corti, Roberto; Wijns, William; Morice, Marie-Claude; Di Mario, Carlo; Van Geuns, Robert-Jan; Van Es, Gerrit-Anne; Juni, Peter; Windecker, Stephan (2011). The three year follow-up of the randomised "all-comers" trial of a biodegradable polymer biolimus-eluting stent versus permanent polymer sirolimus-eluting stent (LEADERS). EuroIntervention, 7(7), pp. 789-795. Toulouse: Europa Digital & Publishing 10.4244/EIJV7I7A125 <http://dx.doi.org/10.4244/EIJV7I7A125>

Tipo

info:eu-repo/semantics/article