Two-year clinical follow-up from the randomized comparison of biolimus-eluting stents with biodegradable polymer and sirolimus-eluting stents with durable polymer in routine clinical practice


Autoria(s): Klauss, Volker; Serruys, Patrick W; Pilgrim, Thomas; Buszman, Pawel; Linke, Axel; Ischinger, Thomas; Eberli, Franz; Corti, Roberto; Wijns, William; Morice, Marie-Claude; di Mario, Carlo; van Geuns, Robert Jan; van Es, Gerrit-Anne; Kalesan, Bindu; Wenaweser, Peter; Jüni, Peter; Windecker, Stephan
Data(s)

2011

Resumo

Objectives This study sought to investigate safety and efficacy of biolimus-eluting stents (BES) with biodegradable polymer as compared with sirolimus-eluting stents (SES) with durable polymer through 2 years of follow-up. Background BES with a biodegradable polymer provide similar efficacy and safety as SES with a durable polymer at 9 months. Clinical outcomes beyond the period of biodegradation of the polymer used for drug release and after discontinuation of dual antiplatelet therapy are of particular interest. Methods A total of 1,707 patients were randomized to unrestricted use of BES (n = 857) or SES (n = 850) in an all-comers patient population. Results At 2 years, BES remained noninferior compared with SES for the primary endpoint, which was a composite of cardiac death, myocardial infarction, or clinically indicated target vessel revascularization (BES 12.8% vs. SES 15.2%, hazard ratio [HR]: 0.84, 95% confidence interval [CI]: 0.65 to 1.08, pnoninferiority < 0.0001, psuperiority = 0.18). Rates of cardiac death (3.2% vs. 3.9%, HR: 0.81, 95% CI: 0.49 to 1.35, p = 0.42), myocardial infarction (6.3% vs. 5.6%, HR: 1.12, 95% CI: 0.76 to 1.65, p = 0.56), and clinically indicated target vessel revascularization (7.5% vs. 8.6%, HR: 0.86, 95% CI: 0.62 to 1.20, p = 0.38) were similar for BES and SES. The rate of definite stent thrombosis through 2 years was 2.2% for BES and 2.5% for SES (p = 0.73). For the period between 1 and 2 years, event rates for definite stent thrombosis were 0.2% for BES and 0.5% for SES (p = 0.42). After discontinuation of dual antiplatelet therapy, no very late definite stent thrombosis occurred in the BES group. Conclusions At 2 years of follow-up, the unrestricted use of BES with a biodegradable polymer maintained a similar safety and efficacy profile as SES with a durable polymer. (Limus Eluted From a Durable Versus Erodable Stent Coating [LEADERS]; NCT00389220)

Formato

application/pdf

Identificador

http://boris.unibe.ch/7217/1/Klauss%20JACCCardiovascInterv%202011.pdf

Klauss, Volker; Serruys, Patrick W; Pilgrim, Thomas; Buszman, Pawel; Linke, Axel; Ischinger, Thomas; Eberli, Franz; Corti, Roberto; Wijns, William; Morice, Marie-Claude; di Mario, Carlo; van Geuns, Robert Jan; van Es, Gerrit-Anne; Kalesan, Bindu; Wenaweser, Peter; Jüni, Peter; Windecker, Stephan (2011). Two-year clinical follow-up from the randomized comparison of biolimus-eluting stents with biodegradable polymer and sirolimus-eluting stents with durable polymer in routine clinical practice. JACC. Cardiovascular Interventions, 4(8), pp. 887-895. New York, N.Y.: Elsevier 10.1016/j.jcin.2011.03.017 <http://dx.doi.org/10.1016/j.jcin.2011.03.017>

doi:10.7892/boris.7217

info:doi:10.1016/j.jcin.2011.03.017

info:pmid:21851904

urn:issn:1876-7605

Idioma(s)

eng

Publicador

Elsevier

Relação

http://boris.unibe.ch/7217/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Klauss, Volker; Serruys, Patrick W; Pilgrim, Thomas; Buszman, Pawel; Linke, Axel; Ischinger, Thomas; Eberli, Franz; Corti, Roberto; Wijns, William; Morice, Marie-Claude; di Mario, Carlo; van Geuns, Robert Jan; van Es, Gerrit-Anne; Kalesan, Bindu; Wenaweser, Peter; Jüni, Peter; Windecker, Stephan (2011). Two-year clinical follow-up from the randomized comparison of biolimus-eluting stents with biodegradable polymer and sirolimus-eluting stents with durable polymer in routine clinical practice. JACC. Cardiovascular Interventions, 4(8), pp. 887-895. New York, N.Y.: Elsevier 10.1016/j.jcin.2011.03.017 <http://dx.doi.org/10.1016/j.jcin.2011.03.017>

Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed