968 resultados para ultrasound ct
Resumo:
Background Low-intensity pulsed ultrasound stimulation (LIPUS) reportedly increases osteogenesis in fracture models but fails in intact bone, suggesting LIPUS does not act on mechanotransduction and growth factor pathways of intact bone. Questions/Purposes We asked whether daily 20-minute LIPUS applied to intact tibias would act on bone proteins involved in mechanotransduction (focal adhesion kinase [FAK], and extracellular signal-regulated kinase-1/2 [ERK-1/2]), and growth factor signaling (insulin receptor substrate-1 [IRS-1]) pathways at 7, 14, and 21 days of treatment. Methods Immunoblotting was performed to detect FAK, ERK-1/2, and IRS-1 expression and activation from the stimulated intact tibias at 7, 14, and 21 days of daily 20-minute LIPUS. Results LIPUS increased FAK expression (at 7 days), ERK-1/2 (at 14 days), and IRS-1 (at 7 days), but expression decreased 7 days later, indicating a noncumulative effect of LIPUS. As only FAK expression was detected at 21 days, these observations suggest LIPUS influences nuclear reactions that may be modulated by a major cellular mechanism preferentially inhibiting IRS-1 expression and not FAK expression. Increased ERK-1/2 expression at 14 days suggests the differing mechanisms for promoting ERK-1/2, FAK, and IRS-1 syntheses. IRS-1 expression behaved similarly to FAK expression; therefore, LIPUS may modulate growth factor pathways. LIPUS increased sustained FAK and ERK-1/2 activation, but not IRS-1, suggesting sustained ERK-1/2 activation is not the result of mechanically induced growth factor activation. Conclusions LIPUS acts on mechanotransduction and growth factor pathways in intact bone in a noncumulative manner. Clinical relevance These data suggest LIPUS applied to intact bone acts on proteins involved in osteogenesis.
Resumo:
Sigma phase is a deleterious one which can be formed in duplex stainless steels during heat treatment or welding. Aiming to accompany this transformation, ferrite and sigma percentage and hardness were measured on samples of a UNS S31803 duplex stainless steel submitted to heat treatment. These results were compared to measurements obtained from ultrasound and eddy current techniques, i.e., velocity and impedance, respectively. Additionally, backscattered signals produced by wave propagation were acquired during ultrasonic inspection as well as magnetic Barkhausen noise during magnetic inspection. Both signal types were processed via a combination of detrended-fluctuation analysis (DFA) and principal component analysis (PCA). The techniques used were proven to be sensitive to changes in samples related to sigma phase formation due to heat treatment. Furthermore, there is an advantage using these methods since they are nondestructive. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
The therapeutic ultrasound (US) is one of the resources mostly used by physiotherapists; however the use of uncalibrated equipments results in inefficient or even harmful therapies to the patient. In this direction, the objective of this study was to evaluate the performance and the procedures of utilization and maintenance of US in use in clinics and Physical-therapy offices. A questionnaire with questions related to the procedures applied in service during the use of therapeutic ultrasound was applied to physiotherapists. The performance of 31 equipments of 6 different brands and 13 different models was evaluated according to the IEC 61689 norm. The parameters measured were: acoustic power; effective radiating area (AER); non-uniformity ratio of the beam (RBN); maximum effective intensity; acoustic frequency of operation, modulation factor and wave form on pulsate mode. As for the questionnaires, it was evident that the professionals are not concerned about the calibration of the equipment. The results demonstrated that only 32.3% of the equipments were in accordance with the norms for the variables power and effective radiation area. The frequency analysis indicated that 20% of the 3 MHz transducers and 12.5% of the 1 MHz contemplated the norms. In the pulsate mode, 12.7% presented relation rest/duration inside allowed limits. A great variation of the ultrasonic field was observed on the obtained images, which presented beams not centered, sometimes with bifurcation of its apex. The results allow concluding that, although used in therapeutic sessions with the population, none of the equipments presents all the analyzed variables inside technical norms. (C) 2010 Elsevier B. V. All rights reserved.
Resumo:
Intravascular ultrasound (IVUS) image segmentation can provide more detailed vessel and plaque information, resulting in better diagnostics, evaluation and therapy planning. A novel automatic segmentation proposal is described herein; the method relies on a binary morphological object reconstruction to segment the coronary wall in IVUS images. First, a preprocessing followed by a feature extraction block are performed, allowing for the desired information to be extracted. Afterward, binary versions of the desired objects are reconstructed, and their contours are extracted to segment the image. The effectiveness is demonstrated by segmenting 1300 images, in which the outcomes had a strong correlation to their corresponding gold standard. Moreover, the results were also corroborated statistically by having as high as 92.72% and 91.9% of true positive area fraction for the lumen and media adventitia border, respectively. In addition, this approach can be adapted easily and applied to other related modalities, such as intravascular optical coherence tomography and intravascular magnetic resonance imaging. (E-mail: matheuscardosomg@hotmail.com) (C) 2011 World Federation for Ultrasound in Medicine & Biology.
Resumo:
Aims: We aimed to evaluate if the co-localisation of calcium and necrosis in intravascular ultrasound virtual histology (IVUS-VH) is due to artefact, and whether this effect can be mathematically estimated. Methods and results: We hypothesised that, in case calcium induces an artefactual coding of necrosis, any addition in calcium content would generate an artificial increment in the necrotic tissue. Stent struts were used to simulate the ""added calcium"". The change in the amount and in the spatial localisation of necrotic tissue was evaluated before and after stenting (n=17 coronary lesions) by means of a especially developed imaging software. The area of ""calcium"" increased from a median of 0.04 mm(2) at baseline to 0.76 mm(2) after stenting (p<0.01). In parallel the median necrotic content increased from 0.19 mm(2) to 0.59 mm(2) (p<0.01). The ""added"" calcium strongly predicted a proportional increase in necrosis-coded tissue in the areas surrounding the calcium-like spots (model R(2)=0.70; p<0.001). Conclusions: Artificial addition of calcium-like elements to the atherosclerotic plaque led to an increase in necrotic tissue in virtual histology that is probably artefactual. The overestimation of necrotic tissue by calcium strictly followed a linear pattern, indicating that it may be amenable to mathematical correction.
Resumo:
The scaled-up preparation of 1H-pyrazole, 1-phenylpyrazole and isoxazole via sonocatalysis is reported. The products were isolated in good yields in short time reaction. These compounds had been assayed for antioxidant activity by ORAC and DPPH methodologies. The results showed that only 1-phenylpyrazole presented good antioxidant activity compared with Trolox(R).
Resumo:
An ultrasound-assisted synthesis of functionalized symmetrical biaryls with electron-withdrawing or electron-donating substituents is described and illustrated by the palladium-catalyzed detelluration of 1,2-diarylditellanes. This procedure offers easy access to symmetrical biaryls in short reaction time and the products are achieved in good to excellent yields. (c) 2009 Published by Elsevier Ltd.
Resumo:
An ultrasound-assisted synthesis of symmetrical biaryls with electron-withdrawing or -donating substituents is described and illustrated by palladium-catalyzed homocoupling reaction of aryl tellurides. This procedure offers easy access to biaryls in short reaction time, and the products are achieved in good to excellent yields.
Resumo:
In vitro skin permeation of hyaluronidase enzyme and the ultrasound (US) effects on cutaneous permeation of this enzyme were investigated. Diffusion cell technique, porcine skins, buffer solution, and a hydrophilic gel+hyaluronidase (100 TUR/g), were used for study. The experimental groups were: gel+enzyme and gel+enzyme+US. The activity of permeated hyaluronidase was determined by turbydimetric method in spectrophotometer at 400nm. Gel+enzyme group permitted a diffusion of 26.89 +/- 3.82 TUR of hyaluronidase in the total time of 240 minutes. However, the other group did not produce significant differences (p0.05) in the same period (13.68 +/- 5.35 TUR). Hyaluronidase permeation through the skin was verified; however US did not cause increase of this enzyme permeation.
Resumo:
An ultrasound-assisted synthesis of functionalized 1,3-enyne scaffolds is described and illustrated by palladium-catalyzed cross-coupling of potassium alkynyltrifluoroborate salts and alpha-styrylbutyltellurides. This procedure offers easy access to 1,3-enyne architecture that contains aliphatic and aromatic groups in good to excellent yields.
Resumo:
This paper describes a simple method for mercury speciation in seafood samples by LC-ICP-MS with a fast sample preparation procedure. Prior to analysis, mercury species were extracted from food samples with a solution containing mercaptoethanol, L-cysteine and HCl and sonication for 15 min. Separation of mercury species was accomplished in less than 5 min on a C8 reverse phase column with a mobile phase containing 0.05%-v/v mercaptoethanol, 0.4% m/v L-cysteine and 0.06 mol L(-1) ammonium acetate. The method detection limits were found to be 0.25, 0.20 and 0.1 ng g(-1) for inorganic mercury, ethylmercury and methylmercury, respectively. Method accuracy is traceable to Certified Reference Materials (DOLT-3 and DORM-3) from the National Research Council Canada (NRCC). With the proposed method there is a considerable reduction of the time of sample preparation. Finally, the method was applied for the speciation of mercury in seafood samples purchased from the Brazilian market. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Human N-acetyltransferase type 1 (NAT1) catalyses the N- or O-acetylation of various arylamine and heterocyclic amine substrates and is able to bioactivate several known carcinogens. Despite wide inter-individual variability in activity, historically, NAT1 was considered to be monomorphic in nature. However, recent reports of allelic variation at the NAT1 locus suggest that it may be a polymorphically expressed enzyme. In the present study, peripheral blood mononuclear cell NAT1 activity in 85 individuals was found to be bimodally distributed with approximately 8% of the population being slow acetylators. Subsequent sequencing of the individuals having slow acetylator status showed all to have either a (CT)-T-190 or G(560)A base substitution located in the protein encoding region of the NAT1 gene. The (CT)-T-190 base substitution changed a highly conserved Arg(64), which others have shown to be essential for fully functional NAT1 protein. The (CT)-T-190 mutation has not been reported previously and we have named it NAT1*17. The G(560)A mutation is associated with the base substitutions previously observed in the NAT1*10 allele and this variant (NAT1*14) encodes for a protein with reduced acetylation capacity. A novel method using linear PCR and dideoxy terminators was developed for the detection of NAT1*14 and NAT1*17. Neither of these variants was found in the rapid acetylator population. We conclude that both the (CT)-T-190 (NAT1*17) and G(560)A (NAT1*14) NAT1 structural variants are involved in a distinct NAT1 polymorphism. Because NAT1 can bioactivate several carcinogens, this polymorphism may have implications for cancer risk in individual subjects. (C) 1998 Chapman & Hall Ltd.
Resumo:
Purpose: The purpose of the study was to assess quantitative ultrasound (QUS) parameters in collegiate female gymnasts, a population whose training incorporates high-impact loading, which is particularly osteogenic, and to determine the discriminative capacity of this relatively new radiation-free technique compared with bone densitometry in a young healthy population. Methods: We studied 19 collegiate gymnasts and 23 healthy controls undergoing regular weight-bearing activity, matched for age (gymnasts 19.2 +/- 1.2, controls 19.9 +/- 1.6 yr) and body weight (gymnasts 56.7 +/- 3.7, controls 57.7 +/- 7.8 kg). QUS parameters of the calcaneus (broadband ultrasound attenuation (BUA), bone velocity (BV), and speed of sound (SOS)) were measured by a Walker Sonix UBA 575+. Bone mineral density (BMD; g.cm(-2)) of the lumbar spine, hip (Femoral neck, trochanter. Ward's triangle) and whole body was assessed by dual energy x-ray absorptiometry (DXA, Hologic QDR 1000/W). Data analysis included unpaired two-tailed Student's t-tests, analysis of variance, Pearson product-moment, and Spearman rank-order correlations. Results: Regional and whole body BMD of gymnasts was greater than controls (P < 0.001), with the difference being 7-28%. Average QUS parameters of the right and left calcaneus were also higher (P < 0.001) in the gymnasts. BUA, BV, and SOS were significantly (P < 0.001) correlated to each bone site with r = 0.54-0.79. Analysis of receiver operating characteristic (ROC) curves indicated no significant difference in sensitivity and specificity for QUS and DXA measures. Conclusions: These results indicate that QUS parameters of the calcaneus are higher in young women gymnasts compared to individuals who undergo regular weight-bearing activity and that QUS parameters are able to discriminate between these two groups in a similar manner as does regional and whole body BMD.
Resumo:
Background. Increased life expectancy in men during the last thirty years is largely due to the decrease in mortality from cardiovascular disease in the age group 29-69 yr. This change has resulted in a change in the disease profile of the population with conditions such as aneurysm of the abdominal aorta (AAA) becoming more prevalent. The advent of endoluminal treatment for AAA has encouraged prophylactic intervention and fuelled the argument to screen for the disease. The feasibility of inserting an endoluminal graft is dependent on the morphology and growth characteristics of the aneurysm. This study used data from a randomized controlled trial of ultrasound screening for AAA in men aged 65-83 yr in Western Australia for the purpose of determining the norms of the living anatomy in the pressurized infrarenal aorta. Aims. To examine (1) the diameters of the infra-renal aorta in aneurysmal and non-aneurysmal cases, (2) the implications for treatment modalities, with particular reference to endoluminal grafting, which is most dependent on normal and aneurysmal morphology, and (3) any evidence to support the notion that northern Europeans are predisposed to aneurysmal disease. Methods. Using ultrasound, a randomized control trial was established in Western Australia to assess the value of a screening program in males aged 65-83 yr, The infra-renal aorta was defined as aneurysmal if the maximum diameter was 30 mm or more. Aortic diameter was modelled both as a continuous tin mm) and as a binary outcome variable, for those men who had an infra-renal diameter of 30 mm or more. ANOVA and linear regression were used for modelling aortic diameter as a continuum, while chi-square analysis and logistic regression were used in comparing men with and without the diagnosis of AAA. Findings. By December 1998, of 19.583 men had been invited to undergo ultrasound screening for AAA, 12.203 accepted the invitation (corrected response fraction 70.8%). The prevalence of AAA increased with age from 4.8% at 65 yr to 10.8% at 80 yr (chi (2) = 77.9, df = 3, P<0.001). The median (IQR) diameter for the non-aneurysmal group was 21.4 mm (3.3 mm) and there was an increase (<chi>(2) = 76.0, df = 1, P<0.001) in the diameter of the infra-renal aorta with age. Since 27 mm is the 95th centile for the non-aneurysmal infra-renal aorta, a diameter of 30 mm or more is justified as defining an aneurysm. The risk of AAA was higher in men of Australian (OR = 1.0) and northern European origin (OR = 1.0, 95%CL: 0.9. 1.2) compared with those of Mediterranean origin (OR = 0.5, 99%CL: 0.4, 0.7). Conclusion. Although screening has not yet been shown to reduce mortality from AAA. these population-based data assist the understanding of aneurysmal disease and the further development and use of endoluminal grafts for this condition. (C) 2001 Published by Elsevier Science Ltd on behalf of The International Society for Cardiovascular Surgery.
Resumo:
A new method for the evaluation of radiotherapy 3D polymer gel dosimeters has been developed using ultrasound to assess the significant structural changes that occur following irradiation of the dosimeters. The ultrasonic parameters of acoustic speed of propagation, attenuation and transmitted signal intensity were measured as a function of absorbed radiation dose. The dose sensitivities for each parameter were determined as 1.8 x 10(-4) s m(-1) Gy(-1), 3.9 dB m(-1) Gy(-1) and 3.2 V-1 Gy(-1) respectively. All parameters displayed a strong variation with absorbed dose that continued beyond absorbed doses of 15 Gy. The ultrasonic measurements demonstrated a significantly larger dynamic range in dose response curves than that achieved with previously published magnetic resonance imaging (MRI) dose response data. It is concluded that ultrasound shows great potential as a technique for the evaluation of polymer gel dosimeters.