990 resultados para pulmonary function


Relevância:

70.00% 70.00%

Publicador:

Resumo:

The strength of the respiratory muscles can be evaluated from static measurements (maximal inspiratory and expiratory pressures, MIP and MEP) or inferred from dynamic maneuvers (maximal voluntary ventilation, MVV). Although these data could be suitable for a number of clinical and research applications, no previous studies have provided reference values for such tests using a healthy, randomly selected sample of the adult Brazilian population. With this main purpose, we prospectively evaluated 100 non-smoking subjects (50 males and 50 females), 20 to 80 years old, selected from more than 8,000 individuals. Gender-specific linear prediction equations for MIP, MEP and MVV were developed by multiple regression analysis: age and, secondarily, anthropometric measurements explained up to 56% of the variability of the dependent variables. The most cited previous studies using either Caucasian or non-Caucasian samples systematically underestimated the observed values of MIP (P<0.05). Interestingly, the self-reported level of regular physical activity and maximum aerobic power correlates strongly with both respiratory and peripheral muscular strength (knee extensor peak torque) (P<0.01). Our results, therefore, provide a new frame of reference to evaluate the normalcy of some useful indexes of respiratory muscle strength in Brazilian males and females aged 20 to 80.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Carbon monoxide diffusing capacity (DLCO) or transfer factor (TLCO) is a particularly useful test of the appropriateness of gas exchange across the lung alveolocapillary membrane. With the purpose of establishing predictive equations for DLCO using a non-smoking sample of the adult Brazilian population, we prospectively evaluated 100 subjects (50 males and 50 females aged 20 to 80 years), randomly selected from more than 8,000 individuals. Gender-specific linear prediction equations were developed by multiple regression analysis with single breath (SB) absolute and volume-corrected (VA) DLCO values as dependent variables. In the prediction equations, age (years) and height (cm) had opposite effects on DLCOSB (ml min-1 mmHg-1), independent of gender (-0.13 (age) + 0.32 (height) - 13.07 in males and -0.075 (age) + 0.18 (height) + 0.20 in females). On the other hand, height had a positive effect on DLCOSB but a negative one on DLCOSB/VA (P<0.01). We found that the predictive values from the most cited studies using predominantly Caucasian samples were significantly different from the actually measured values (P<0.05). Furthermore, oxygen uptake at maximal exercise (VO2max) correlated highly to DLCOSB (R = 0.71, P<0.001); this variable, however, did not maintain an independent role to explain the VO2max variability in the multiple regression analysis (P>0.05). Our results therefore provide an original frame of reference for either DLCOSB or DLCOSB/VA in Brazilian males and females aged 20 to 80 years, obtained from the standardized single-breath technique.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The objective of the present study was to determine if there is a health-related quality of life (HRQL) instrument, generic or specific, that better represents functional capacity dysfunction in idiopathic pulmonary fibrosis (IPF) patients. HRQL was evaluated in 20 IPF patients using generic and specific questionnaires (Medical Outcomes Short Form 36 (SF-36) and Saint George's Respiratory Questionnaire (SGRQ), respectively). Functional status was evaluated by pulmonary function tests, 6-min walking distance test (6MWDT) and dyspnea indexes (baseline dyspnea index) at rest and after exercise (modified Borg scale). There was a restrictive pattern with impairment of diffusion capacity (total lung capacity, TLC = 71.5 ± 15.6%, forced vital capacity = 70.4 ± 19.4%, and carbon monoxide diffusing capacity = 41.5 ± 16.2% of predicted value), a reduction in exercise capacity (6MWDT = 435.6 ± 95.5 m) and an increase of perceived dyspnea score at rest and during exercise (6 ± 2.5 and 7.1 ± 1.3, respectively). Both questionnaires presented correlation with some functional parameters (TLC, forced expiratory volume in 1 s and carbon monoxide diffusing capacity) and the best correlation was with TLC. Almost all of the SGRQ domains presented a strong correlation with functional status, while in SF-36 only physical function and vitality presented a good correlation with functional status. Dyspnea index at rest and 6MWDT also presented a good correlation with HRQL. Our results suggest that a specific instead of a generic questionnaire is a more appropriate instrument for HRQL evaluation in IPF patients and that TLC is the functional parameter showing best correlation with HRQL.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Studies of cooking-generated NO2 effects are rare in occupational epidemiology. In the present study, we evaluated the lung function of professional cooks exposed to NO2 in hospital kitchens. We performed spirometry in 37 cooks working in four hospital kitchens and estimated the predicted FVC, FEV1 and FEF25-75, based on age, sex, race, weight, and height, according to Knudson standards. NO2 measurements were obtained for 4 consecutive days during 4 different periods at 20-day intervals in each kitchen. Measurements were performed inside and outside the kitchens, simultaneously using Palm diffusion tubes. A time/exposure indicator was defined as representative of the cumulative exposure of each cook. No statistically significant effect of NO2 exposure on FVC was found. Each year of work as a cook corresponded to a decrease in predicted FEV1 of 2.5% (P = 0.046) for the group as a whole. When smoking status and asthma were included in the analysis the effect of time/exposure decreased about 10% and lost statistical significance. On predicted FEF25-75, a decrease of 3.5% (P = 0.035) was observed for the same group and the inclusion of controllers for smoking status and asthma did not affect the effects of time/exposure on pulmonary function parameter. After a 10-year period of work as cooks the participants of the study may present decreases in both predicted FEV1 and FEF25-75 that can reach 20 and 30%, respectively. The present study showed small but statistically significant adverse effects of gas stove exposure on the lung function of professional cooks.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The role of airway inflammation in ventilated preterm newborns and the risk factors associated with the development of chronic lung disease are not well understood. Our objective was to analyze the association of the airway inflammatory response in ventilated preterm infants by serial measurements of TNF-a and IL-10 in tracheobronchial lavage (TBL) with perinatal factors and lung function measured early in life. A series of TBL samples were collected from ventilated preterm infants (less than 32 weeks of gestational age) and concentrations of TNF-a and IL-10 were measured by ELISA. Pulmonary function tests were performed after discharge by the raised volume rapid compression technique. Twenty-five subjects were recruited and 70 TBL samples were obtained. There was a significant positive association between TNF-a and IL-10 levels and length of time between the rupture of the amniotic membranes and delivery (r = 0.65, P = 0.002, and r = 0.57, P < 0.001, respectively). Lung function was measured between 1 and 22 weeks of corrected age in 10 patients. Multivariable analysis with adjustment for differences in lung volume showed a significant negative association between TNF-a levels and forced expiratory flow (FEF50; r = -0.6; P = 0.04), FEF75 (r = -0.76; P = 0.02), FEF85 (r = -0.75; P = 0.03), FEF25-75 (-0.71; P = 0.02), and FEV0.5 (r = -0.39; P = 0.03). These data suggest that TNF-a levels in the airways during the first days of life were associated with subsequent lung function abnormalities measured weeks or months later.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Disturbed sleep is common in chronic obstructive pulmonary disease (COPD). Conventional hypnotics worsen nocturnal hypoxemia and, in severe cases, can lead to respiratory failure. Exogenous melatonin has somnogenic properties in normal subjects and can improve sleep in several clinical conditions. This randomized, double-blind, placebo-controlled study was carried out to determine the effects of melatonin on sleep in COPD. Thirty consecutive patients with moderate to very severe COPD were initially recruited for the study. None of the participants had a history of disease exacerbation 4 weeks prior to the study, obstructive sleep apnea, mental disorders, current use of oral steroids, methylxanthines or hypnotic-sedative medication, nocturnal oxygen therapy, and shift work. Patients received 3 mg melatonin (N = 12) or placebo (N = 13), orally in a single dose, 1 h before bedtime for 21 consecutive days. Sleep quality was assessed by the Pittsburgh Sleep Quality Index (PSQI) and daytime sleepiness was measured by the Epworth Sleepiness Scale. Pulmonary function and functional exercise level were assessed by spirometry and the 6-min walk test, respectively. Twenty-five patients completed the study protocol and were included in the final analysis. Melatonin treatment significantly improved global PSQI scores (P = 0.012), particularly sleep latency (P = 0.008) and sleep duration (P = 0.046). No differences in daytime sleepiness, lung function and functional exercise level were observed. We conclude that melatonin can improve sleep in COPD. Further long-term studies involving larger number of patients are needed before melatonin can be safely recommended for the management of sleep disturbances in these patients.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Because histopathological changes in the lungs of patients with systemic sclerosis (SSc) are consistent with alveolar and vessel cell damage, we presume that this interaction can be characterized by analyzing the expression of proteins regulating nitric oxide (NO) and plasminogen activator inhibitor-1 (PAI-1) synthesis. To validate the importance of alveolar-vascular interactions and to explore the quantitative relationship between these factors and other clinical data, we studied these markers in 23 cases of SSc nonspecific interstitial pneumonia (SSc-NSIP). We used immunohistochemistry and morphometry to evaluate the amount of cells in alveolar septa and vessels staining for NO synthase (NOS) and PAI-1, and the outcomes of our study were cellular and fibrotic NSIP, pulmonary function tests, and survival time until death. General linear model analysis demonstrated that staining for septal inducible NOS (iNOS) related significantly to staining of septal cells for interleukin (IL)-4 and to septal IL-13. In univariate analysis, higher levels of septal and vascular cells staining for iNOS were associated with a smaller percentage of septal and vascular cells expressing fibroblast growth factor and myofibroblast proliferation, respectively. Multivariate Cox model analysis demonstrated that, after controlling for SSc-NSIP histological patterns, just three variables were significantly associated with survival time: septal iNOS (P=0.04), septal IL-13 (P=0.03), and septal basic fibroblast growth factor (bFGF; P=0.02). Augmented NOS, IL-13, and bFGF in SSc-NSIP histological patterns suggest a possible functional role for iNOS in SSc. In addition, the extent of iNOS, PAI-1, and IL-4 staining in alveolar septa and vessels provides a possible independent diagnostic measure for the degree of pulmonary dysfunction and fibrosis with an impact on the survival of patients with SSc.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This thesis describes an ancillary project to the Early Diagnosis of Mesothelioma and Lung Cancer in Prior Asbestos Workers study and was conducted to determine the effects of asbestos exposure, pulmonary function and cigarette smoking in the prediction of pulmonary fibrosis. 613 workers who were occupationally exposed to asbestos for an average of 25.9 (SD=14.69) years were sampled from Sarnia, Ontario. A structured questionnaire was administered during a face-to-face interview along with a low-dose computed tomography (LDCT) of the thorax. Of them, 65 workers (10.7%, 95%CI 8.12—12.24) had LDCT-detected pulmonary fibrosis. The model predicting fibrosis included the variables age, smoking (dichotomized), post FVC % splines and post- FEV1% splines. This model had a receiver operator characteristic area under the curve of 0.738. The calibration of the model was evaluated with R statistical program and the bootstrap optimism-corrected calibration slope was 0.692. Thus, our model demonstrated moderate predictive performance.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Pulmonary rehabilitation (PR) programs are beneficial to patients with chronic obstructive pulmonary disease (COPD), and lower-extremity training is considered a fundamental component of PR. Nevertheless, the isolated effects of each PR component are not well established. Objective: We aimed to evaluate the effects of a cycle ergometry exercise protocol as the only intervention in a group of COPD patients, and to compare these results with a control group. Methods: 25 moderate-to-severe COPD patients were evaluated regarding pulmonary function, respiratory muscle strength, exercise capacity, quality of life and body composition. Patients were allocated to one of two groups: (a) the trained group (TG; n=13; 6 men) was submitted to a protocol of 24 exercise sessions on a cycle ergometer, with training intensity initially set at a heart rate (HR) close to 80% of maximal HR achieved in a maximal test, and load increase based on dyspnea scores, and (b) the control group (CG; n=12; 6 men) with no intervention during the protocol period. Results: TG showed within-group significant improvements in endurance cycling time, 6-min walking distance test, maximal inspiratory pressure and in the domain 'dyspnea' related to quality of life. Despite the within-group changes, no between-group significant differences were observed. Conclusion: In COPD patients, the results of isolated low-to-moderate intensity cycle ergometer training are not comparable to effects of multimodality and high-intensity training programs. Copyright (C) 2004 S. Karger AG, Basel.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Meconium (MEC) is a potent inactivator of pulmonary surfactant. The authors studied the effects of polyethylene glycol addition to the exogenous surfactant over the lung mechanics and volumes. Human meconium was administrated to newborn rabbits. Animals were ventilated for 20 minutes and dynamic compliance, ventilatory pressure, and tidal volume were recorded. Animals were randomized into 3 study groups: MEC group (without surfactant therapy); S100 group (100 mg/kg surfactant); and PEG group (100 mg/kg porcine surfactant plus 5% PEG). After ventilation, a pulmonary pressure-volume curve was built. Histological analysis was carried out to calculate the mean alveolar size (Lm) and the distortion index (DI). Both groups treated with surfactant showed higher values of dynamic pulmonary compliance and lower ventilatory pressure, compared with the MEC group (P .05). S100 group had a larger maximum lung volume, V30, compared with the MEC group (P .05). Lm and DI values were smaller in the groups treated with surfactant than in the MEC group (P .05). No differences were observed between the S100 and PEG groups. Animals treated with surfactant showed significant improvement in pulmonary function as compared to nontreated animals. PEG added to exogenous surfactant did not improve lung mechanics or volumes.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Studies of cooking-generated NO2 effects are rare in occupational epidemiology. In the present study, we evaluated the lung function of professional cooks exposed to NO2 in hospital kitchens. We performed spirometry in 37 cooks working in four hospital kitchens and estimated the predicted FVC, FEV1 and FEF25-75, based on age, sex, race, weight, and height, according to Knudson standards. NO2 measurements were obtained for 4 consecutive days during 4 different periods at 20-day intervals in each kitchen. Measurements were performed inside and outside the kitchens, simultaneously using Palm diffusion tubes. A time/exposure indicator was defined as representative of the cumulative exposure of each cook. No statistically significant effect of NO2 exposure on FVC was found. Each year of work as a cook corresponded to a decrease in predicted FEV1 of 2.5% (P = 0.046) for the group as a whole. When smoking status and asthma were included in the analysis the effect of time/exposure decreased about 10% and lost statistical significance. on predicted FEF25-75, a decrease of 3.5% (P = 0.035) was observed for the same group and the inclusion of controllers for smoking status and asthma did not affect the effects of time/exposure on pulmonary function parameter. After a 10-year period of work as cooks the participants of the study may present decreases in both predicted FEV1 and FEF25-75 that can reach 20 and 30%, respectively. The present study showed small but statistically significant adverse effects of gas stove exposure on the lung function of professional cooks.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In order to determine wheter blood gases abnormalities, specially hypoxemia, are associated with more marked changes in fat-free mass in patients with chronic obstructive pulmonary disease (CPOD), nutritional assessment was performed on 16 normoxemic (PaO 2 > 55 mm Hg) and 16 hypoxemic (PaO 2 < 55 mm Hg) COPD patients in stable clinical condition. Body weight was expressed as percentage of the ideal body weight. Fat-free mass was estimated by anthropometry (FFM-Anthr) and by bioelectrical impedance (FFM- BI). Handgrip-strength was assessed as a measure of peripheral skeletal muscle strength. Patients were age-matched and presented similar degree of airway obstruction. Malnutrition, defined as body weight less than 90% of the ideal, was observed in 19% of the normoxemic patients and in 25% of the hypoxemic patients (p>0,05). FFM values in hypoxemic patients, estimated by both methods, were not different from those observed in normoxemic patients. No significant difference was observed on handgrip values between the two groups. No correlation was found between nutritional indices and pulmonary function and gases exchange parameters. FFM correlated positively with values of peripheral muscle function in normoxemic and hypoxemic patients. These data add further evidence to the hypothesis that hypoxemia is not a primary cause of the nutritional deficiency observed in COPD patients.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: The use of biomass for cooking and heating is considered an important factor associated with respiratory diseases. However, few studies evaluate the amount of particulate matter less than 2.5 mu in diameter (PM2.5), symptoms and lung function in the same population. Objectives: To evaluate the respiratory effects of biomass combustion and compare the results with those of individuals from the same community in Brazil using liquefied petroleum gas (Gas). Methods: 1402 individuals in 260 residences were divided into three groups according to exposure (Gas, Indoor-Biomass, Outside-Biomass). Respiratory symptoms were assessed using questionnaires. Reflectance of paper filters was used to assess particulate matter exposure. In 48 residences the amount of PM2.5 was also quantified. Pulmonary function tests were performed in 120 individuals. Results: Reflectance index correlated directly with PM2.5 (r=0.92) and was used to estimate exposure (ePM2.5). There was a significant increase in ePM2.5 in Indoor-Biomass and Outside-Biomass, compared to Gas. There was a significantly increased odds ratio (OR) for cough, wheezing and dyspnea in adults exposed to Indoor-Biomass (OR=2.93, 2.33, 2.59, respectively) and Outside-Biomass (OR=1.78, 1.78, 1.80, respectively) compared to Gas. Pulmonary function tests revealed both Non-Smoker-Biomass and Smoker-Gas individuals to have decreased %predicted-forced expiratory volume in the first second (FEV1) and FEV1/forced vital capacity (FVC) as compared to Non-Smoker-Gas. Pulmonary function tests data was inversely correlated with duration and ePM2.5. The prevalence of airway obstruction was 20% in both Non-Smoker-Biomass and Smoker-Gas subjects. Conclusion: Chronic exposure to biomass combustion is associated with increased prevalence of respiratory symptoms, reduced lung function and development of chronic obstructive pulmonary disease. These effects are associated with the duration and magnitude of exposure and are exacerbated by tobacco smoke. (C) 2011 Elsevier Inc. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Lymphangioleiomyomatosis (LAM) is characterised by progressive airway obstruction and hypoxaemia in young women. Although sleep may trigger hypoxaemia in patients with airway obstruction, it has not been previously investigated in patients with LAM. Methods: Consecutive women with lung biopsy proven LAM and absence of hypoxaemia while awake were evaluated with pulmonary function test, echocardiography, 6-min walk test, overnight full polysomnography, and Short Form 36 health-related quality-of-life questionnaire. Results: Twenty-five patients with (mean +/- SD) age 45 +/- 10 years, SpO(2) awake 95% +/- 2, forced expiratory volume in the first second (median-interquartile) FEV1 (% predicted) 77 (47-90) and carbonic monoxide diffusion capacity, DLCO (%) 55 (34-74) were evaluated. Six-minute walk test distance and minimum SpO(2) (median-interquartile) were, respectively, 447 m (411 -503) and 90% (82-94). Median interquartile apnoea-hypopnoea index was in the normal range 2 (1-5). Fourteen patients (56%) had nocturnal hypoxaemia (10% total sleep time with SpO(2) <90%), and the median sleep time spent with SpO(2) <90% was 136 (13-201) min. Sleep time spent with SpO(2) <90% correlated with the residual volume/total lung capacity ratio (r(s) = 0.5, p: 0.02), DLCO (r(s) = -0.7, p: 0.001), FEV1 (r(s) = -0.6, p: 0.002). Multivariate linear regression model showed that RV/TLC ratio was the most important functional variable related to sleep hypoxaemia. Conclusion: Significant hypoxaemia during sleep is common in LAM patients with normal SpO(2) while awake, especially among those with some degree of hyperinflation in lung function tests. (C) 2011 Published by Elsevier Ltd.