217 resultados para plaster
Resumo:
Objective: To evaluate the effects of local administration of epidermal growth factor (EGF) located within liposomes on recruitment of osteoclasts during mechanical force in rats. Materials and Methods: An orthodontic elastic band was inserted between the left upper first and second molars, to move mesially the first molar. Rats were randomly divided into 4 groups (n = 8): EGF (2 ng/mu L) located within liposomes (group 1), liposomes only (group 2), soluble EGF (2 ng/mu L; group 3), or vehicle alone (group 4). The solutions were injected into the region of the root furcation of the left first molar after elastic band insertion. Tooth movement was measured using a plaster model of the maxilla, and the number of osteoclasts recruited at the pressure side of the first molar was histologically evaluated. Results: Intergroup analysis showed that there was no significant difference between group 2 and group 4 (P >.05) and between group 1 and group 3 (P >.05). However, group 1 and group 3 exhibited greater differences in tooth movement than group 2 and group 4 (P <.05). On the other hand, group 1 showed greater tooth movement than groups 2 and 4 with statistical significance (P <.01). The increase in the number of osteoclasts in group 1 was significantly higher than in the other groups (P <.05). Conclusion: Exogenous EGF-liposome administration has an additive effect when compared with soluble EGF on the rate of osteoclast recruitment, producing faster bone resorption and tooth movement.
Resumo:
The effect of Pigment Volume Content (PVC) on fungal growth on acrylic paint formulations with and without biocide, exposed to weathering in three different climatic regions in Brazil for four years, was studied Latex paints. with PVC of 30%, 35% and 50%, were applied to autoclaved aerated concrete blocks pre-covered with acrylic sealer and acrylic plaster They were exposed to equatorial, tropical and temperate climates in north, south-east, and south Brazil Cladosporium was the most abundant fungal genus detected in the biofilm on the surfaces of all paint formulations at all sites after four years Heaviest fungal colonization occurred in the tropical south-east and lightest in the temperate south of the country, but more phototrophs, principally cyanobacteria, were detected in the equatorial region PVC and presence of biocides were shown to be of less importance than environmental conditions (irradiance, humidity and temperature) for biofilm formation and consequent discolouration These results have important implications for testing of paint formulations (C) 2010 Elsevier B V All rights reserved
Resumo:
This paper presents a rheological investigation of pure gypsum (PG) and a commercial gypsum-lime-filler plaster (CP) using the modified Vicat apparatus and squeeze flow method. The samples were tested at several different intervals after manual or mechanical mixing. The results confirmed squeeze flow to be more sensitive in determining fresh paste behavior than the modified Vicat apparatus. PG set faster when prepared in mechanical mixer than when manually mixed. Conversely, the CP composition presented longer setting when mixed mechanically. The study also included the analysis of two ready-to-use polymer-based products for leveling and rendering (drywall joint compound - DJC; acrylic putty - AP) measured by squeeze flow and compared to the commercial composition. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Colour pattern variation is a striking and widespread phenomenon. Differential predation risk between individuals is often invoked to explain colour variation, but empirical support for this hypothesis is equivocal. We investigated differential conspicuousness and predation risk in two species of Australian rock dragons, Ctenophorus decresii and C. vadnappa. To humans, the coloration of males of these species varies between 'bright' and 'dull'. Visual modelling based on objective colour measurements and the spectral sensitivities of avian visual pigments showed that dragon colour variants are differentially conspicuous to the visual system of avian predators when viewed against the natural background. We conducted field experiments to test for differential predation risk, using plaster models of 'bright' and 'dull' males. 'Bright' models were attacked significantly more often than 'dull' models suggesting that differential conspicuousness translates to differential predation risk in the wild. We also examined the influence of natural geographical range on predation risk. Results from 22 localities suggest that predation rates vary according to whether predators are familiar with the prey species. This study is among the first to demonstrate both differential conspicuousness and differential predation risk in the wild using an experimental protocol. (C) 2003 Published by Elsevier Ltd on behalf of The Association for the Study of Animal Behaviour.
Resumo:
Neste trabalho é abordado o estágio efectuado por um período de sete meses na E.A. (Engenheiros Associados) e um estudo de caso sobre as tecnologias aplicadas no isolamento térmico de paredes exteriores. Na primeira parte deste relatório é efectuada uma breve caracterização da empresa e da sua actividade no mercado. A Engenheiros e Associados tem a sua estrutura assente nos seguintes sectores: Técnico-Comercial, de Aprovisionamento e de Gestão Administrativa; da qual foi efectuada uma descrição do trabalho desenvolvido em cada um desses sectores, nomeadamente a permanência na obra e as visitas e diligências às obras. A segunda parte deste relatório, que é a parte fulcral do trabalho desenvolvido, assenta sobre o sistema de ETICS (External Thermal Insulation Composite System), ou seja, o sistema de reboco delgado armado sobre isolamento térmico. Foi utilizado o sistema Cappotto na Obra de Requalificação da Urbanização de Vila d’Este – 1ª Fase. Após uma breve apresentação e evolução da história do ETICS ao longo do tempo, é exposta a caracterização da obra onde vai ser aplicado o sistema, que recai sobre a tipologia dos edifícios. Refira-se que, neste relatório, os edifícios por serem de construção túnel se dividem em três tipos: tipo plana ou corrente, tipo ângulo e tipo topo. Na Analise de Patologias efectuada evidenciam-se as fissuras e a humidade presentes em quase toda a extensão dos referidos edifícios antes do tratamento, tornando-as assim as principais anomalias destes edifícios. Foram elemento de foco as anomalias existentes nos edifícios, como: Deterioração do fibrocimento; Insuficiência das caleiras; Deficiências das impermeabilizações; Ausência de rufos; Deficiência das ligações; Degradação do revestimento e pintura; Fissuração do reboco; Degradação dos forros exteriores; Deterioração das padieiras; Deterioração dos peitoris; Deterioração das juntas de dilatação; Infiltrações e condensações; Ruptura das canalizações; Deslocamentos; Deficiências de ventilação; Deficiências de estanqueidade; Inexistência de Sistema de combate a incêndios. Para estas patologias são apresentadas as propostas de solução de forma a eliminar as mesmas. Sendo o ETICS escolhido por ser o sistema que elimina a maior parte destas patologias, tendo em conta uma relação de qualidade/preço, é abordada de uma forma detalhada e extensiva da aplicação do sistema antes, durante e depois da obra em si. Assim como, é feita uma descrição pormenorizada do material utilizado para a implementação do sistema. A análise dos pontos críticos refere-se a zonas sensíveis onde há a necessidade de reforço do sistema com vista a eliminar o aparecimento posterior de patologias, como por exemplo as características de suporte. Após a aplicação do sistema podem aparecer algumas patologias das quais se destaca o facto dos produtos serem preparados em obra, o erro humano nas dosagens do fabricante e no acrescento de água sem necessidade e a par das condições climatéricas, são as causas mais comuns do aparecimento de anomalias no sistema de ETICS, provocando fissurações e infiltrações, que são descritas neste relatório. É também abordada a manutenção e reparação do sistema, onde a manutenção refere-se à lavagem e à remoção de microorganismos das paredes e posterior pintura. A reparação dos danos divide-se em dois tipos, áreas até 2 cm2 e áreas maiores que 2 cm2. Por fim, são apresentados alguns rendimentos, que foram possíveis obter ao longo do desenvolvimento do trabalho, dos materiais e da mão-de-obra, dando origem aos custos directos. Sendo também abordadas as vantagens e desvantagens do sistema desde o seu início até à sua conclusão.
Resumo:
A gestão de energia é um dos factores chave do sucesso de uma empresa e como qualquer outro factor de produção deve ser gerido continuamente e eficazmente. A gestão correcta do consumo de energia assume-se como crucial nas empresas do sector cerâmico pois exigem grande consumo de gás natural. Também a tendência de aumento do custo do gás natural tem induzido a necessidade de minimização do consumo de combustível nas indústrias e favorecido o desenvolvimento de novas abordagens para a optimização deste recurso natural. O trabalho apresentado nesta tese teve como objectivo a optimização da energia nas estufas de secagem na Fábrica de Cerâmica de Valadares S.A. A actividade desta empresa consiste na produção de louça sanitária envolvendo um consumo elevado de energia. Realizou-se um levantamento das condições técnicas/operacionais dos equipamentos em estudo e elaborou-se uma ferramenta de simulação que foi aplicada para realizar um balanço energético detalhado e diagnóstico da situação existente. No seguimento, foi efectuada uma análise de mercado, para elaboração do estudo económico da implementação das medidas sugeridas, nomeadamente, a recuperação dos gases de combustão que saem das três estufas que secam os moldes para as estufas de louça cerâmica. Optou-se por esta medida uma vez que reduzirá significativamente, em cerca de 50%, o consumo de combustível (gás natural) nas estufas de secagem. O tempo de retorno do investimento necessário para adquirir o equipamento é de, aproximadamente, 10 meses.
Resumo:
9th International Masonry Conference 2014, 7-9 July, Universidade do Minho, Guimarães
Resumo:
International Conference on Vernacular Heritage, Sustainability and Earthen Architecture, VerSus 2014, 2nd MEDITERRA, 2nd ResTAPIA, 11-13 September, Valencia, Spain
Resumo:
A ready-mixed and several laboratory formulated mortars were produced and tested in fresh state and after hardening, simulating a masonry plaster for indoor application. All the mortars used a clayish earth from the same region and different compositions of aggregates, eventually including fibres and a phase change material. All the formulated mortars were composed by 1:3 volumetric proportions of earth and aggregate. Tests were developed for consistency, fresh bulk density, thermal conductivity, capillary absorption and drying, water vapour permeability and sorption-desorption. The use of PCM changed drastically the workability of the mortars and increased their capillary absorption. The use of fibres and variations on particle size distribution of the mixtures of sand that were used had no significant influence on tested properties. But particularly the good workability of these mortars and the high capacity of sorption and desorption was highlighted. With this capacity plasters made with these mortars are able to adsorb water vapour from indoor atmosphere when high levels of relative humidity exist and release water vapour when the indoor atmosphere became too dry. This fact makes them able to contribute passively for a healthier indoor environment. The technical, ecological and environmental advantages of the application of plasters with this type of mortars are emphasized, with the aim of contributing for an increased use for new or existent housing.
Resumo:
Due to their high adsorption capacity of water vapor, earthen plasters can act as a moisture buffer, contributing to balance the relative humidity of the indoor environment of buildings. As a consequence of this capacity earthen plasters may also contribute to the perception of thermal comfort, since a high relative humidity increases the thermal conductivity of air and restricts skin evaporation, increasing the discomfort associated with the perception of heat or cold. Simultaneously, earthen plasters may also contribute to the indoor air quality. In one hand, by mitigating health problems of the respiratory system associated with indoor environment with high relative humidity, in which increases the risk of development of microorganisms usually responsible for infections, allergies or asthma. In the other hand, by mitigating the probability of inflammation of the respiratory system airways associated to exceedingly dry indoor environments. Therefore it also becomes expectable that earthen plasters may contribute for reducing the needs for air conditioning and mechanical ventilation in buildings and, thereby, also allowing the reduction of the associated energy consumption. The «Barrocal» region, located in the sedimentary basin of Algarve, South Portugal, presents geomorphological characteristics that promote the occurrence of soils with a clay mineralogy dominated by illite, which is a clay mineral characterized by a high adsorption capacity of water vapor and low expansibility. This fact turns expectable that these soils have a high potential for interior plastering. In order to evaluate this potential four mortars were formulated with an increasing content of clayey soil extracted from a selected clay quarry from «Barrocal» region. The results from the preliminary characterization campaign confirmed the reduced linear shrinkage of these mortars, as well as their high adsorption-desorption capacity, that is positively correlated with the content of clayey soil present in mortar formulation. However, the mechanical tests showed that the mechanical resistance of these mortars should be improved, for instance through the addition of natural fibers for reinforcement, which will be investigated in future research. This research contributed to increase certainty regarding the potential of clayey soils of the «Barrocal» sub-region of Algarve to produce mortars suitable for eco-efficient interior plastering.
Resumo:
This study aimed to evaluate the Chagas Disease Control Program which has operated since 1982 in the municipality of Berilo in the Jequitinhonha Valley, Minas Gerais, Brazil, based on evaluation of 5,242 domiciliary units (DUs) and 7,807 outbuildings over an eight-year period of epidemiological surveillance implanted in 1997. A total of 391 triatomines (280 Panstrongylus megistus and 111 Triatoma pseudomaculata) were captured, indicating the continued predominance of the former species. However, Triatoma pseudomaculata is clearly becoming more important in this region, with intradomiciliary colonies being detected in recent years. Entomological parameters, such as dispersion (17%) and intradomiciliary infestation (0.15%) indices, are compatible with the results of the epidemiological surveillance. The majority of DUs were of construction type A (plaster over bricks) or C (plaster over adobe). Twenty-five percent of the inhabitants of the DUs infested by triatomines were reactive in ELISA, IHA and IIF tests for Trypanosoma cruzi antigens.
Resumo:
Clayish earth-based mortars are been recognized, all over the world, as eco-efficient products for plastering. Apart from being a product with low embodied energy when compared to other types of plasters, their application on the interior surface of walls may give a strong contribution for the health and comfort of inhabitants. As part of an ongoing research regarding earth-based plasters this work assesses the influence of the addition of two types of natural fibres – oat straw and typha fiber-wool – on the characteristics of plastering mortars made with a clayish earth. Mechanical and physical characteristics were tested, showing that addition of these fibers contribute to decrease linear drying shrinkage and thermal conductivity, as well as promoting the adhesion strength of plaster to the substrate. The improvement of mechanical resistance reveal to be dependent on the type of fiber added while the hygroscopic capacity of the plaster is maintained regardless of the fiber additions.
Resumo:
Earthen plastering mortars are becoming recognized as highly eco-efficient. The assessment of their technical properties needs to be standardized but only the German standard DIN 18947 exists for the moment. An extended experimental campaign was developed in order to assess multiple properties of a ready-mixed earth plastering mortar and also to increase scientific knowledge of the influence of test procedures on those properties. The experimental campaign showed that some aspects related to the equipment, type of samples and sample preparation can be very important, while others seemed to have less influence on the results and the classification of mortars. It also showed that some complementary tests can easily be performed and considered together with the standardized ones, while others may need to be improved. The plaster satisfied the requirements of the existing German standard but, most importantly, it seemed adequate for application as rehabilitation plaster on historic and modern masonry buildings. Apart from their aesthetic aspect, the contribution of earthen plasters to eco-efficiency and particularly to hygrometric indoor comfort should be highlighted.
Resumo:
Abstract:INTRODUCTION:Despite the recommendations by interpretation of resistance ratios obtained in laboratory bioassays, little is known about the actual impact of these results in the effectiveness of vector control activities in the field. In this context, our objective was to determine the mean value of different resistance ratios obtained by laboratory bioassays performed as part of the chemical control strategies of Triatoma sordida in the field.METHODS:Field bioassays were developed in Monte Azul and Coração de Jesus (Southeast, Brazil). In each location, samples were formed with three domestic units treated with alpha-cypermethrin 20.0% (Alfatek (r) 200 SC). One day after spraying, 10 fifth-instar nymphs remained in contact with the surfaces treated (adobe with plaster, adobe without plaster, or wood) with insecticide in plastic cones for 72h. Three cones were exposed inside the intradomicile and the peridomicile. The insects in the control group were exposed to an insecticide-free piece of cardboard. Mortality was measured 72h after removal of the insects from the treated surfaces. The tests were realized in triplicate.RESULTS:Mortality was 100.0% in all locations, except for Monte Azul; Landinho (96.6%) and Coração de Jesus; Barriguda (96.6%).CONCLUSIONS:Although the resistant populations in laboratory tests proved to be susceptible in the field, this observation is not sufficient to suggest that the cut-off points used to justify the resistance ratio should be changed. In this sense, we recommend that laboratory and field bioassays are carried out with a greater number of Triatominae populations to allow more in-depth consideration of the subject.
Resumo:
Timber frame buildings are well known as an efficient seismic resistant structure and they are used worldwide. Moreover, they have been specifically adopted in codes and regulations during the XVIII and XIX centuries in the Mediterranean area. These structures generally consist of exterior masonry walls with timber elements embedded which tie the walls together and internal walls which have a timber frame with masonry infill and act as shearwalls. In order to preserve these structureswhich characterizemany cities in theworld it is important to better understand their behaviour under seismic actions. Furthermore, historic technologies could be used even in modern constructions to build seismic resistant buildings using more natural materials with lesser costs. Generally, different types of infill could be applied to timber frame walls depending on the country, among which brick masonry, rubble masonry, hay and mud. The focus of this paper is to study the seismic behaviour of the walls considering different types of infill, specifically: masonry infill, lath and plaster and timber frame with no infill. Static cyclic tests have been performed on unreinforced timber frame walls in order to study their seismic capacity in terms of strength, stiffness, ductility and energy dissipation. The tests showed how in the unreinforced condition, the infill is able to guarantee a greater stiffness, ductility and ultimate capacity of the wall.