952 resultados para monovision correction
Resumo:
The aim of this study was to evaluated the efficacy of the Old Way/New Way methodology (Lyndon, 1989/2000) with regard to the permanent correction of a consolidated and automated technical error experienced by a tennis athlete (who is 18 years old and has been engaged in practice mode for about 6 years) in the execution of serves. Additionally, the study assessed the impact of intervention on the athlete’s psychological skills. An individualized intervention was designed using strategies that aimed to produce a) a detailed analysis of the error using video images; b) an increased kinaesthetic awareness; c) a reactivation of memory error; d) the discrimination and generalization of the correct motor action. The athlete’s psychological skills were measured with a Portuguese version of the Psychological Skills Inventory for Sports (Cruz & Viana, 1993). After the intervention, the technical error was corrected with great efficacy and an increase in the athlete’s psychological skills was verified. This study demonstrates the methodology’s efficacy, which is consistent with the effects of this type of intervention in different contexts.
Resumo:
"Series title: Springerbriefs in applied sciences and technology, ISSN 2191-530X"
Resumo:
We describe the case of a 40-day-old female patient with a history of breathlessness since birth who was referred to our hospital for surgical correction of common arterial trunk. The invasive investigation disclosed a Fallot¢s tetralogy anatomy associated with an anomalous origin of the left pulmonary artery from the ascending aorta. Immediately after diagnosis, the patient underwent a successful total surgical correction of the defect, including simultaneous anastomosis of the left pulmonary artery to the pulmonary trunk.
Resumo:
OBJECTIVE: To evaluate whether left ventricular end-systolic (ESD) diameters £ 51mm in patients (pt) with severe chronic mitral regurgitation (MR) are predictors of a poor prognosis after mitral valve surgery (MVS). METHODS: Eleven pt (aged 36±13 years) were studied in the preoperative period (pre), median of 36 days; in the early postoperative period (post1), median of 9 days; and in the late postoperative period (post2), mean of 38.5±37.6 months. Clinical and echocardiographic data were gathered from each pt with MR and systolic diameter ³51mm (mean = 57±4mm) to evaluate the result of MVS. Ten patients were in NYHA Class III/IV. RESULTS: All but 2 pt improved in functional class. Two pt died from heart failure and infectious endocarditis 14 and 11 months, respectively, after valve replacement. According to ejection fraction (EF) in post2, we identified 2 groups: group 1 (n=6), whose EF decreased in post1, but increased in post2 (p=0.01) and group 2 (n=5), whose EF decreased progressively from post1 to post2 (p=0.10). All pt with symptoms lasting £ 48 months had improvement in EF in post2 (p=0.01). CONCLUSION: ESD ³51mm are not always associated with a poor prognosis after MVS in patients with MR. Symptoms lasting up to 48 months are associated with improvement in left ventricular function.
Resumo:
We present a case of aneurysmal dilation of the aortic residual segment, involving abdominal vessels in corrective surgeries for thoracoabdominal aortic aneurysm, through the identification of risk groups for recurrent dilation, aiming at using a specific operative technique with a branched graft, to prevent aneurysm relapse.
Resumo:
Magdeburg, Univ., Fak. für Elektrotechnik und Informationstechnik, Diss., 2010
Resumo:
Magdeburg, Univ., Fak. für Naturwiss., Diss., 2012
Resumo:
BACKGROUND: Cone-beam computed tomography (CBCT) image-guided radiotherapy (IGRT) systems are widely used tools to verify and correct the target position before each fraction, allowing to maximize treatment accuracy and precision. In this study, we evaluate automatic three-dimensional intensity-based rigid registration (RR) methods for prostate setup correction using CBCT scans and study the impact of rectal distension on registration quality. METHODS: We retrospectively analyzed 115 CBCT scans of 10 prostate patients. CT-to-CBCT registration was performed using (a) global RR, (b) bony RR, or (c) bony RR refined by a local prostate RR using the CT clinical target volume (CTV) expanded with 1-to-20-mm varying margins. After propagation of the manual CT contours, automatic CBCT contours were generated. For evaluation, a radiation oncologist manually delineated the CTV on the CBCT scans. The propagated and manual CBCT contours were compared using the Dice similarity and a measure based on the bidirectional local distance (BLD). We also conducted a blind visual assessment of the quality of the propagated segmentations. Moreover, we automatically quantified rectal distension between the CT and CBCT scans without using the manual CBCT contours and we investigated its correlation with the registration failures. To improve the registration quality, the air in the rectum was replaced with soft tissue using a filter. The results with and without filtering were compared. RESULTS: The statistical analysis of the Dice coefficients and the BLD values resulted in highly significant differences (p<10(-6)) for the 5-mm and 8-mm local RRs vs the global, bony and 1-mm local RRs. The 8-mm local RR provided the best compromise between accuracy and robustness (Dice median of 0.814 and 97% of success with filtering the air in the rectum). We observed that all failures were due to high rectal distension. Moreover, the visual assessment confirmed the superiority of the 8-mm local RR over the bony RR. CONCLUSION: The most successful CT-to-CBCT RR method proved to be the 8-mm local RR. We have shown the correlation between its registration failures and rectal distension. Furthermore, we have provided a simple (easily applicable in routine) and automatic method to quantify rectal distension and to predict registration failure using only the manual CT contours.
Resumo:
This paper develops methods for Stochastic Search Variable Selection (currently popular with regression and Vector Autoregressive models) for Vector Error Correction models where there are many possible restrictions on the cointegration space. We show how this allows the researcher to begin with a single unrestricted model and either do model selection or model averaging in an automatic and computationally efficient manner. We apply our methods to a large UK macroeconomic model.
Resumo:
BACKGROUND: Surgical correction of complete atrio-ventricular septal defect (AVSD) achieves satisfactory results with low morbidity and mortality, but may require reoperation. Our recent operative results at mid-term were followed-up. METHODS: From June 2000 to December 2007, 81 patients (Down syndrome; n=60), median age 4.0 months (range 0.7-118.6) and weight 4.7kg (range 2.2-33), underwent complete AVSD correction. Patch closure for the ventricular septal defect (VSD; n=69) and atrial septal defect (ASD; n=42) was performed with left atrio-ventricular valve (LAVV) cleft closure (n=76) and right atrio-ventricular valve (RAVV) repair (n=57). Mortality, morbidity, and indications for reoperation were retrospectively studied; the end point 'time to reoperation' was analyzed using Kaplan-Meier curves. Follow-up was complete except in two patients and spanned a median of 28 months (range 0.4-6.1 years). RESULTS: In-hospital mortality was 3.7% (n=3) and one late death occurred. Reoperation was required in 7/79 patients (8.9%) for LAVV insufficiency (n=4), for a residual ASD (n=1), for right atrio-ventricular valve insufficiency (n=1), and for subaortic stenosis (n=1). At last follow-up, no or only mild LAVV and RAVV insufficiency was present in 81.3% and 92.1% of patients, respectively, and 2/3 of patients were medication-free. Risk factors for reoperation were younger age (<3 months; p=0.001) and lower weight (<4kg; p=0.003), and a trend towards less and later reoperations in Down syndrome (p<0.2). CONCLUSIONS: Surgical correction of AVSD can be achieved with low mortality and need for reoperation, regardless of Down syndrome or not. Immediate postoperative moderate or more residual atrio-ventricular valve insufficiency will eventually require a reoperation, and could be anticipated in patients younger than 3 months and weighing <4kg.
Resumo:
Patients with defective ectodysplasin A (EDA) are affected by X-linked hypohidrotic ectodermal dysplasia (XLHED), a condition characterized by sparse hair, inability to sweat, decreased lacrimation, frequent pulmonary infections, and missing and malformed teeth. The canine model of XLHED was used to study the developmental impact of EDA on secondary dentition, since dogs have an entirely brachyodont, diphyodont dentition similar to that in humans, as opposed to mice, which have only permanent teeth (monophyodont dentition), some of which are very different (aradicular hypsodont) than brachyodont human teeth. Also, clinical signs in humans and dogs with XLHED are virtually identical, whereas several are missing in the murine equivalent. In our model, the genetically missing EDA was compensated for by postnatal intravenous administration of soluble recombinant EDA. Untreated XLHED dogs have an incomplete set of conically shaped teeth similar to those seen in human patients with XLHED. After treatment with EDA, significant normalization of adult teeth was achieved in four of five XLHED dogs. Moreover, treatment restored normal lacrimation and resistance to eye and airway infections and improved sweating ability. These results not only provide proof of concept for a potential treatment of this orphan disease but also demonstrate an essential role of EDA in the development of secondary dentition.
Resumo:
Based on the Ahumada et al. (2007, Review of Income and Wealth) critique we revise existing estimates of the size of the German underground economy. Among other things, it turns out that most of these estimates are untenable and that the tax pressure induced size of the German underground economy may be much lower than previously thought. To this extent, German policy and law makers have been misguided during the last three decades. Therefore, we introduce the Modified-Cash-Deposit-Ratio (MCDR) approach, which is not subject to the recent critique and apply it to Germany for the period 1960 to 2008. JEL: O17, Q41, C22, Keywords: underground economy, shadow economy, cash-depositratio, currency demand approach, MIMIC approach
Resumo:
OBJECTIVES: Residual mitral regurgitation after valve repair worsens patients' clinical outcome. Postimplant adjustable mitral rings potentially address this issue, allowing the reshaping of the annulus on the beating heart under echocardiography control. We developed an original mitral ring allowing valve geometry remodelling after the implantation and designed an animal study to assess device effectiveness in correcting residual mitral regurgitation. METHODS: The device consists of two concentric rings: one internal and flexible, sutured to the mitral annulus and a second external and rigid. A third conic element slides between the two rings, modifying the shape of the flexible ring. This sliding element is remotely activated with a rotating tool. Animal model: in adult swine, under cardio pulmonary bypass and cardiac arrest, we shortened the primary chordae of P2 segment to reproduce Type III regurgitation and implanted the active ring. We used intracardiac ultrasound to assess mitral regurgitation and the efficacy of the active ring to correct it. RESULTS: Severe mitral regurgitation (3+ and 4+) was induced in eight animals, 54 ± 6 kg in weight. Vena contracta width decreased from 0.8 ± 0.2 to 0.1 cm; proximal isovelocity surface area radius decreased from 0.8 ± 0.2 to 0.1 cm and effective regurgitant orifice area decreased from 0.50 ± 0.1 to 0.1 ± 0.1 cm(2). Six animals had a reversal of systolic pulmonary flow that normalized following the activation of the device. All corrections were reversible. CONCLUSIONS: Postimplant adjustable mitral ring corrects severe mitral regurgitation through the reversible modification of the annulus geometry on the beating heart. It addresses the frequent and morbid issue of recurrent mitral valve regurgitation.
Resumo:
We study preconditioning techniques for discontinuous Galerkin discretizations of isotropic linear elasticity problems in primal (displacement) formulation. We propose subspace correction methods based on a splitting of the vector valued piecewise linear discontinuous finite element space, that are optimal with respect to the mesh size and the Lamé parameters. The pure displacement, the mixed and the traction free problems are discussed in detail. We present a convergence analysis of the proposed preconditioners and include numerical examples that validate the theory and assess the performance of the preconditioners.