1000 resultados para moldação por injeção


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An indirect flow injection spectrophotometric procedure is proposed for the determination of N-acetyl-L-cysteine in pharmaceutical formulations. In this system, ferroin ([Fe(II)-(fen)2]2+) in excess, with a strong absorption at 500 nm, is oxidized by cerium(IV) yielding cerium(III) and [Fe(III)-(fen)2]3+ (colorless), thus producing a baseline. When N-acetyl-L-cysteine solution is introduced into the flow injection system, it reacts with cerium(IV) increasing the analytical signal in proportion to the drug concentration. Under optimal experimental conditions, the linearity of the analytical curve for N-acetyl-L-cysteine ranged from 6.5x10-6 to 1.3x10-4 mol L-1. The detection limit was 5.0x10-6 mol L-1and recoveries between 98.0 and 106% were obtained. The sampling frequency was 60 determinations per hour and the RSD was smaller than 1.4% for 2.2x10-5 mol L-1 N-acetyl-L-cysteine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of bovine serum albumin-immobilized supports have been prepared and used as restricted access media (RAM) columns. Restricted-access supports combine size-exclusion of proteins and other high-molar-mass matrix components with the simultaneous enrichment of low-molar mass analytes. These characteristics were chromatographically evaluated for the columns. The RAM-BSA (Bovine Serum Albumin) columns showed excellent performance for exclusion of human plasma protein with good retention capacity for a series of acidic, basic, and neutral drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection turbidimetric procedure exploiting merging zones is proposed for determining homatropine methylbromide (HMB) in pharmaceutical preparations. The determination is based on the precipitation reaction of homatropine methylbromide with AgNO3 solution to form a precipitate, which was measured at 410 nm. The analytical curve was linear in the HMB concentration range from 8.0x10-4 to 1.7x10-3 mol L-1, with a detection limit of 9.5x10-5 mol L-1. The recoveries ranged from 94.9 to 104 %, the sampling frequency was 75 h-1 and relative standard deviations were smaller than 2.0 % for solutions containing 1.2x10-3 and 1.5x10-3 mol L-1 HMB (n=10). The results obtained for commercial formulations using the FIA procedure were in good agreement with those obtained by using a comparative method (r= 0.9983).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sensitivity and accuracy of sequential injection methods are dependent on efficient overlapping of reagent and sample zones as they are propelled toward the detector cell. The formation of the reduced phosphomolybdic acid is used to demonstrate that the overlapping efficiency in a fixed reaction coil relies on a suitable choice of reagent to sample volume ratio. Additionally, under poor mixing conditions or highly concentrated samples, the reaction extension is strongly dependent on the reagent concentration. The zone-sampling concept is exploited to determine phosphate in cola-based soft drinks after in-line dilution in an auxiliary coil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a homemade autosampler for flow injection analysis (FIA), constructed with two step motors from old floppy disk drives (5¼-inch). The autosampler was connected to a computer through the parallel port and the sampling process was controlled by software in Quick Basic. The performance of the system was assessed by the determination of ammonium, based on the gaseous diffusion into a bromocresol purple solution, following the spectrophotometric determination of change in absorbance. The easy and simple construction is the main characteristics of this equipment and analytical results with RSD lower than 1% were obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical method has been developed and validated for the determination of an association of ampicillins in a lyophilized powder for injection by HPLC. The advantage of chromatographic method other than the microbiological one is that, it is possible to monitor precisely, out-of-specification results in quality control processes and also during stability studies, in which an association of ampicillins is present. The proposed HPLC method was developed by using forced degraded samples, in order to reach a selective analysis of ampicillins when in the presence of their degradation products. It was possible to detect benzatine and through indirect calculation, to determine the ampicillin sodium in the drug sample. The method showed to be selective, accurate, precise, robust and linear (from 45.92 to 36.04 μg mL-1 of total ampicillin and from 14.53 to 43.28 μg mL-1 of benzatine). The accuracy determined from recovery test, gave results in the range of 99.41% of total ampicillin to 100.31% of benzatine. Hence, it can be concluded that the proposed HPLC method is applicable for ampicillins determination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The year of 2010 marks the 20th anniversary of the development of Sequential Injection Analysis (SIA) by Ruzicka and Marshall. Considered the second generation of the flow injection methods, this article briefly describes the history, the basic principles of the technique and reviews all papers developed by Brazilian scientists aiming the divulgation of this automation technique in Analytical Chemistry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the development of an easy, fast and effective procedure for the verification of the ideal gas law in splitless injection systems in order to improve the response. Results of a group of pesticides were used to demonstrate the suitability of the approach. The procedure helps establish experimental parameters through theoretical aspects. The improved instrumental response allowed extraction with lower sample volumes, the minimization of time and costs and the simplification of sample preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potentialities and applications of the Multiple Pulse Amperometric detection (MPA) coupled with Flow Injection Analysis (FIA) are evaluated. Important aspects as cleaning and activation of electrode surface, indirect and simultaneous analysis of electroactive compounds and the use of the internal standard method for quantifications utilizing FIA-MPA are presented. The main parameters concerning the detection of electroactive analytes by multiple pulse amperometric detection in flowing solutions were also discussed. In addition, aspects such as flow rate, sample volume, application time of the potential pulses and instrumentation necessary for implementing of the method were also addressed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection spectrophotometric procedure for the determination of glyphosate in commercial formulations of herbicides is proposed. The determination is based on the reaction of glyphosate and p-dimethylaminocinnamaldehyde, in acid medium, yielding a colored compound (l máx = 495 nm). Under optimal conditions, Beer's law is obeyed in a concentration range 40-640 mg mL-1 with a correlation coefficient of 0.9996. The detection limit was 8.60 mg mL-1 for glyphosate. The method was successfully applied for the determination of glyphosate in commercial formulations of herbicides. Recovery of glyphosate from various commercial samples of herbicides range from 91.0 to 110%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple flow system with multiple pulse amperometric detection using a single working electrode is proposed for simultaneous determination of ascorbic (AA) and acetylsalicylic (AAS) acids in pharmaceutical formulations. The procedure is based on application of two potential pulses: 0.90 V/50 ms: oxidation and determination of AA without the interference of AAS; 1.35 V/50 ms: oxidation of both compounds and quantification of AAS by current subtraction using a correction factor. Sampling rate was estimated as 125 injections per hour and the limits of detection were 0.17 and 0.16 µmol L-1 for AA and AAS, respectively. Results for commercial samples agreed with those obtained using HPLC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fast analytical method for determination of hydroquinone in pharmaceutical formulations employing batch injection analysis (BIA) with amperometric detection using a boron-doped diamond electrode is described. The supporting electrolyte was a 0.1 mol L-1 H2SO4 solution (the single reagent used for analysis). The method showed good repeatability (RSD of 0.45%, n=20), wide linear range (from 10 to 2000 µmol L-1, R=0.9999), low detection limit (0.016 µmol L-1) and satisfactory recovery values (91-96%). Accuracy of the method was evaluated by comparative analyses using high-performance liquid-chromatography. The ability to replace the electronic pipette by disposable syringes (injection procedure) in BIA systems was also shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study describes the use of Principal Component Analysis to evaluate the chemical composition of water produced from eight oil wells in three different production areas. A total of 609 samples of produced water, and a reference sample of seawater, were characterized according to their levels of salinity, calcium, magnesium, strontium, barium and sulphate (mg L-1) contents, and analyzed by using PCA with autoscaled data. The method allowed the identification of variables salinity, calcium and strontium as tracers for formation water, and variables magnesium and sulphate as tracers for seawater.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and fast method for the determination of nimesulide (NI) using flow injection analysis with multiple-pulse amperometric (FIA-MPA) detection at a boron-doped diamond (BDD) electrode was developed. The method was based mainly on the application of a four-potential waveform, E1(det) = -0.8 V / 30 ms, E2(det) = 0.6 V / 30 ms, E3(det) = -0.4 V / 30 ms and E4(cleaning) = -0.45 V / 300 ms versus Ag/AgCl (3.0 mol L-1 KCl). NI was detected at three different electrode potentials, at which the nitro group undergoes different redox reactions. The proposed method was selective and sensitive (detection limit of 81.0 nmol L-1), and successfully applied for the determination of NI in pharmaceutical formulations, yielding similar results to those obtained by the reference method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes a simple and inexpensive flow injection analysis system in which gravity force provides fluid propulsion while needles for insulin administration or metallic wires act as electrodes for amperometric detection. The proposed system was able to demonstrate the influence of several operational parameters on the transient signals. Moreover, this system was successfully used to evaluate both the stoichiometry of Cu2+-EDTA complex and the effect of pH on the kinetics of the reaction between ferricyanide and ascorbic acid. Therefore, the proposed system can be regarded as an efficient and accessible didactic tool for the teaching of FIA principles.