982 resultados para Walls


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Light gauge Steel Frame (LSF) walls are extensively used in the building industry due to the many advantages they provide over other wall systems. Although LSF walls have been used widely, fire design of LSF walls is based on approximate prescriptive methods based on limited fire tests. Also these fire tests were conducted using the standard fire curve [1] and the applicability of available design rules to realistic design fire curves has not been verified. This paper investigates the accuracy of existing fire design rules in the current cold-formed steel standards and the modifications proposed by previous researchers. Of these the recently developed design rules by Gunalan and Mahendran [2] based on Eurocode 3 Part 1.3 [3] and AS/NZS 4600 [4] for standard fire exposure [1] were investigated in detail to determine their applicability to predict the axial compression strengths and fire resistance ratings of LSF walls exposed to realistic design fire curves. This paper also presents the fire performance results of LSF walls exposed to a range of realistic fire curves obtained using a finite element analysis based parametric study. The results from the parametric study were used to develop a simplified design method based on the critical hot flange temperature to predict the fire resistance ratings of LSF walls exposed to realistic fire curves. Finally, the stud failure times (fire resistance rating) obtained from the fire design rules and the simplified design method were compared with parametric study results for LSF walls lined with single and double plasterboards, and externally insulated with rock fibres under realistic fire curves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural fire safety has become one of the key considerations in the design and maintenance of the built infrastructure. Conventionally the fire resistance rating of load bearing Light gauge Steel Frame (LSF) walls is determined based on the standard time-temperature curve given in ISO 834. Recent research has shown that the true fire resistance of building elements exposed to building fires can be less than their fire resistance ratings determined based on standard fire tests. It is questionable whether the standard time-temperature curve truly represents the fuel loads in modern buildings. Therefore an equivalent fire severity approach has been used in the past to obtain fire resistance rating. This is based on the performance of a structural member exposed to a realistic design fire curve in comparison to that of standard fire time-temperature curve. This paper presents the details of research undertaken to develop an energy based time equivalent approach to obtain the fire resistance ratings of LSF walls exposed to realistic design fire curves with respect to standard fire exposure. This approach relates to the amount of energy transferred to the member. The proposed method was used to predict the fire resistance ratings of single and double layer plasterboard lined and externally insulated LSF walls. The predicted fire ratings were compared with the results from finite element analyses and fire design rules for three different wall configurations exposed to both rapid and prolonged fires. The comparison shows that the proposed energy method can be used to obtain the fire resistance ratings of LSF walls in the case of prolonged fires.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Partially grouted masonry walls subjected to in-plane shear exhibit a complex behaviour because of the influence of the aspect ratio, the pre-compression, the grouting pattern, the ratios of the horizontal and the vertical reinforcements, the boundary conditions and the characteristics of the constituent materials. The existing in-plane shear expressions for the partially grouted masonry are formulated as sum of strength of three parameters, namely, the masonry, the reinforcement and the axial force. The parameter ‘masonry’ includes the wall aspect ratio and the masonry compressive strength; the aspect ratio of the unreinforced panel inscribed into the grouted cores and bond beams are not considered, although failure is often dominated by these unreinforced masonry panels. This paper describes the dominance of these panels, particularly those that are squat, to the shear capacity of whole of shear walls. Further, the current design formulae are shown highly un-conservative by many researchers; this paper provides a potential reason for this un-conservativeness. It is shown that by including an additional term of the unreinforced panel aspect ratio a rational design formula could be established. This new expression is validated with independent test results reported in the literature – both Australian and overseas; the predictions are shown to be conservative.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In-plane shear capacity formulation of reinforced masonry is commonly conceived as the sum of the capacities of three parameters, viz, the masonry, the reinforcement, and the precompression. The term “masonry” incorporates the aspect ratio of the wall without any regard to the aspect ratio of the panels inscribed (and hence confined) by the vertical and the horizontal reinforced grout cores. This paper proposes design expressions in which the aspect ratio of such panels is explicitly included. For this purpose, the grouted confining cores are regarded as a grid of confining elements within which the panels are positioned. These confined masonry panels are then considered as building blocks for multi-bay, multi-storied confined masonry shear walls and analyzed using an experimentally validated macroscopic finite-element model. Results of the analyzes of 161 confined masonry walls containing panels of height to length ratio less than 1.0 have been regressed to formulate design expressions. These expressions have been first validated using independent test data sets and then compared with the existing equations in some selected international design standards. The concept of including the unreinforced masonry panel aspect ratio as an additional term in the design expression for partially grouted/confined masonry shear walls is recommended based on the conclusions from this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fire resistance of load bearing Light Gauge Steel Frame (LSF) wall systems is important to protect lives and properties in fire accidents. Recent fire tests of LSF walls made of the new cold-formed and welded hollow flange channel (HFC) section studs and the commonly used lipped channel section (LCS) studs have shown the influence of stud sections on the fire resistance rating (FRR) of LSF walls. To advance the use of HFC section studs and to verify the outcomes from the fire tests, finite element models were developed to predict the structural fire performance of LSF walls made of welded HFC section studs. The developed models incorporated the measured non-uniform temperature distributions in LSF wall studs due to the exposure of standard fire on one side, and accurate elevated temperature mechanical properties of steel used in the stud sections. These models simulated the various complexities involved such as thermal bowing and neutral axis shift caused by the non-uniform temperature distribution in the studs. The finite element analysis (FEA) results agreed well with the full scale fire test results including the FRR, outer hot and cold flange temperatures at failure and axial deformation and lateral displacement profiles. They also confirmed the superior fire performance of LSF walls made of HFC section studs. The applicability of both transient and steady state FEA of LSF walls under fire conditions was verified in this study, which also investigated the effects of using various temperature distribution patterns across the cross-section of HFC section studs on the FRR of LSF walls. This paper presents the details of this numerical study and the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analyzing and redesigning business processes is a complex task, which requires the collaboration of multiple actors. Current approaches focus on collaborative modeling workshops where process stakeholders verbally contribute their perspective on a process while modeling experts translate their contributions and integrate them into a model using traditional input devices. Limiting participants to verbal contributions not only affects the outcome of collaboration but also collaboration itself. We created CubeBPM – a system that allows groups of actors to interact with process models through a touch based interface on a large interactive touch display wall. We are currently in the process of conducting a study that aims at assessing the impact of CubeBPM on collaboration and modeling performance. Initial results presented in this paper indicate that the setting helped participants to become more active in collaboration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analyzing and redesigning business processes is a complex task, which requires the collaboration of multiple actors. Current approaches focus on collaborative modeling workshops where process stakeholders verbally contribute their perspective on a process while modeling experts translate their contributions and integrate them into a model using traditional input devices. Limiting participants to verbal contributions not only affects the outcome of collaboration but also collaboration itself. We created CubeBPM – a system that allows groups of actors to interact with process models through a touch based interface on a large interactive touch display wall. We are currently in the process of conducting a study that aims at assessing the impact of CubeBPM on collaboration and modeling performance. Initial results presented in this paper indicate that the setting helped participants to become more active in collaboration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analyzing and redesigning business processes is a complex task, which requires the collaboration of multiple actors. Current approaches focus on workshops where process stakeholders together with modeling experts create a graphical visualization of a process in a model. Within these workshops, stakeholders are mostly limited to verbal contributions, which are integrated into a process model by a modeling expert using traditional input devices. This limitation negatively affects the collaboration outcome and also the perception of the collaboration itself. In order to overcome this problem we created CubeBPM – a system that allows groups of actors to interact with process models through a touch based interface on a large interactive touch display wall. Using this system for collaborative modeling, we expect to provide a more effective collaboration environment thus improving modeling performance and collaboration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a study on the durability of different types of stabilised and unstabilised rammed earth walls. These rammed earth walls were constructed and exposed for 20 years to natural weathering, in a wet continental climate. None of these walls have shown complete collapse to date. A method to measure the rammed earth walls erosion by stereo-photogrammetry has been developed. The result shows that the mean erosion depth of the studied walls is about 2 mm (0.5% wall thickness) in the case of rammed earth wall stabilised with 5% by dry weight of hydraulic lime and about 6.4 mm (1.6% wall thickness) in the case of unstabilised rammed earth walls. The stabilisation enables to not use any plaster to protect the walls. In the case of the unstabilised rammed earth walls, an extrapolated lifetime longer than 60 years can be assessed. This shows a potential for the use of unstabilised rammed earth in the similar climatic conditions with this study. The method of stereo-photogrammetry used to measure the erosion of rammed earth walls on site may also help to calibrate and develop more pertinent laboratory test to assess the durability of rammed earth wall.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study deals with the dating and the function of the fortress of Agios Donatos, which is located in the Kokytos river valley in Thesprotia, northwestern Greece. To solve the dating problem one had to use parallels found in research literature, preferably within as close range as possible. As most of the fortresses within a close proximity had not been adequately published, one had to use parallels within a larger area, throughout the Hellenistic world. Archaeological material found in trial trenches on site was used when possible. To think of the function of the site one had to study the site itself and its relation to the environment, and to compare the situation with the parallels found in research literature, mostly different archaeological survey projects in Greece and Asia Minor. The fortress was built during a period ranging from the final decades of the fourth century down to the mid-third century BC. Most likely it was built during the first quarter of the third century, that is the reign of Pyrrhus of Epirus when the area experienced a boom in fortress building activity. The function of the site was most likely to protect a trade route from the major port in the area to the central areas of the valley and on to Kalamas river, which was the major route on to Macedon. In the end an appendix dealing with the other fortified sites in Thesprotia has been compiled.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper presents a method for the evaluation of external stability of reinforced soil walls subjected to earthquakes in the framework of the pseudo-dynamic method. The seismic reliability of the wall is evaluated by considering the different possible failure modes such as sliding along the base, overturning about the toe point of the wall, bearing capacity and the eccentricity of the resultant force. The analysis is performed considering properties of the reinforced backfill, foundation soil below the base of the wall, length of the geosynthetic reinforcement and characteristics of earthquake ground motions such as shear wave and primary wave velocity as random variables. The optimum length of reinforcement needed to maintain stability against four modes of failure by targeting various component reliability indices is obtained. Differences between pseudo-static and pseudo-dynamic methods are clearly highlighted in the paper. A complete analysis of pseudo-static and pseudo-dynamic methodologies shows that the pseudodynamic method results in realistic design values for the length of geosynthetic reinforcement under earthquake conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fire resistance of cold-formed light gauge steel frame (LSF) wall systems is enhanced by lining them with single or multiple layers of wall boards with varying thermal properties. These wall boards are gypsum plasterboards or Magnesium Oxide (MgO) boards produced by different manufacturers. Thermal properties of these boards appear to show considerable variations and this can lead to varying fire resistance levels (FRL) for their wall systems. Currently FRLs of wall systems are determined using full scale fire tests, but they are time consuming and expensive. Recent research studies on the fire performance of LSF wall systems have used finite element studies to overcome this problem, but they were developed based on 1-D and 2-D finite element platform capable of performing either heat transfer or structural analysis separately. Hence in this research a 3-D finite element model was developed first for LSF walls lined with gypsum plasterboard and cavity insulation materials. Accurate thermal properties of these boards are essential for finite element modelling, and thus they were measured at both ambient and elevated temperatures. This experimental study included specific heat, relative density and thermal conductivity of boards. The developed 3-D finite element model was then validated using the available fire tests results of LSF walls lined with gypsum plasterboard, and is being used to investigate the fire performance of different LSF wall configurations. The tested MgO board exhibited significant variations in their thermal properties in comparison to gypsum plasterboards with about 50% loss of its initial mass at about 500 ºC compared to 16% for gypsum plasterboards. Hence the FRL of MgO board lined LSF wall systems is likely to be significantly reduced. This paper presents the details of this research study on the fire performance of LSF wall systems lined with gypsum plasterboard and MgO board including the developed 3-D finite element models, thermal property tests and the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Out-of-plane behaviour of mortared and mortarless masonry walls with various forms of reinforcement, including unreinforced masonry as a base case is examined using a layered shell element based explicit finite element modelling method. Wall systems containing internal reinforcement, external surface reinforcement and intermittently laced reinforced concrete members and unreinforced masonry panels are considered. Masonry is modelled as a layer with macroscopic orthotropic properties; external reinforcing render, grout and reinforcing bars are modelled as distinct layers of the shell element. Predictions from the layered shell model have been validated using several out-of-plane experimental datasets reported in the literature. The model is used to examine the effectiveness of two retrofitting schemes for an unreinforced masonry wall.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Consummating our earlier work [1], the unsteady flow of a fairly concentrated suspension due to a single contraction or expansion of the walls of a tube is studied. A comparison of the results obtained by using two different formulae for the additional drag terms in the governing equations has been made. A region of circulation in the flow field is observed when the volume fraction Z greater-or-equal, slanted 0.3, the Schmidt number Sc < 1 and the density ratio (density of the particulate phase/density of the fluid phase) > 1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with the pulsatile blood flow in the lung alveolar sheets by idealizing each of them as a channel covered by porous media. As the blood flow in the lung is of low Reynolds number, a creeping flow is assumed in the channel. The analytical and numerical results for the velocity and pressure distribution in the porous medium are presented. The effect of an imposed slip condition is also studied. Comparisons with the corresponding results for the steady-state case are made at the end.