945 resultados para Optical path difference
Resumo:
We report experimental measurements of the strain and temperature sensitivity of the optical phase in a singlemode polymer optical fibre. These values were obtained by measuring optical path length change using a Mach-Zender interferometer.
Resumo:
The stress sensitivity of polymer optical fibre (POF) based Fabry-Perot sensors formed by two uniform Bragg gratings with finite dimensions is investigated. POF has received high interest in recent years due to its different material properties compared to its silica counterpart. Biocompatibility, a higher failure strain and the highly elastic nature of POF are some of the main advantages. The much lower Young’s modulus of polymer materials compared to silica offers enhanced stress sensitivity to POF based sensors which renders them great candidates for acoustic wave receivers and any kind of force detection. The main drawback in POF technology is perhaps the high fibre loss. In a lossless fibre the sensitivity of an interferometer is proportional to its cavity length. However, the presence of the attenuation along the optical path can significantly reduce the finesse of the Fabry-Perot interferometer and it can negatively affect its sensitivity at some point. The reflectivity of the two gratings used to form the interferometer can be also reduced as the fibre loss increases. In this work, a numerical model is developed to study the performance of POF based Fabry-Perot sensors formed by two uniform Bragg gratings with finite dimensions. Various optical and physical properties are considered such as grating physical length, grating effective length which indicates the point where the light is effectively reflected, refractive index modulation of the grating, cavity length of the interferometer, attenuation and operating wavelength. Using this model, we are able to identify the regimes in which the PMMA based sensor offer enhanced stress sensitivity compared to silica based one.
Resumo:
A method is presented for accurate measurement of spectral flux-reflectance (albedo) in a laboratory, for media with long optical path lengths, such as snow and ice. The approach uses an acrylic hemispheric dome, which, when placed over the surface being studied, serves two functions: (i) it creates an overcast “sky” to illuminate the target surface from all directions within a hemisphere, and (ii) serves as a platform for measuring incident and backscattered spectral radiances, which can be integrated to obtain fluxes. The fluxes are relative measurements and because their ratio is used to determine flux-reflectance, no absolute radiometric calibrations are required. The dome and surface must meet minimum size requirements based on the scattering properties of the surface. This technique is suited for media with long photon path lengths since the backscattered illumination is collected over a large enough area to include photons that reemerge from the domain far from their point of entry because of multiple scattering and small absorption. Comparison between field and laboratory albedo of a portable test surface demonstrates the viability of this method.
Resumo:
Development of design guides to estimate the difference in speech interference level due to road traffic noise between a reference position and balcony position or façade position is explored. A previously established and validated theoretical model incorporating direct, specular and diffuse reflection paths is used to create a database of results across a large number of scenarios. Nine balcony types with variable acoustic treatments are assessed to provide acoustic design guidance on optimised selection of balcony acoustic treatments based on location and street type. In total, the results database contains 9720 scenarios on which multivariate linear regression is conducted in order to derive an appropriate design guide equation. The best fit regression derived is a multivariable linear equation including modified exponential equations on each of nine deciding variables, (1) diffraction path difference, (2) ratio of total specular energy to direct energy, (3) distance loss between reference position and receiver position, (4) distance from source to balcony façade, (5) height of balcony floor above street, (6) balcony depth, (7) height of opposite buildings, (8) diffusion coefficient of buildings, and; (9) balcony average absorption. Overall, the regression correlation coefficient, R2, is 0.89 with 95% confidence standard error of ±3.4 dB.
Resumo:
PURPOSE To estimate refractive indices used by the Lenstar biometer to translate measured optical path lengths into geometrical path lengths within the eye. METHODS Axial lengths of model eyes were determined using the IOLMaster and Lenstar biometers; comparing those lengths gave an overall eye refractive index estimate for the Lenstar. Using the Lenstar Graphical User Interface, we noticed that boundaries between media could be manipulated and opposite changes in optical path lengths on either side of the boundary could be introduced. Those ratios were combined with the overall eye refractive index to estimate separate refractive indices. Furthermore, Haag-Streit provided us with a template to obtain 'air thicknesses' to compare with geometrical distances. RESULTS The axial length estimates obtained using the IOLMaster and the Lenstar agreed to within 0.01 mm. Estimates of group refractive indices used in the Lenstar were 1.340, 1.341, 1.415, and 1.354 for cornea, aqueous, lens, and overall eye, respectively. Those refractive indices did not match those of schematic eyes, but were close in the cases of aqueous and lens. Linear equations relating air thicknesses to geometrical thicknesses were consistent with our findings. CONCLUSION The Lenstar uses different refractive indices for different ocular media. Some of the refractive indices, such as that for the cornea, are not physiological; therefore, it is likely that the calibrations in the instrument correspond to instrument-specific corrections and are not the real optical path lengths.
Resumo:
We derive and analyze the statistics of reflection coefficient of light backscattered coherently from an amplifying and disordered optical medium modeled by a spatially random refractive index having a uniform imaginary part in one dimension. We find enhancement of reflected intensity owing to a synergy between wave confinement by Anderson localization and coherent amplification by the active medium. This is not the same as that due to enhanced optical path lengths expected from photon diffusion in the random active medium. Our study is relevant to the physical realizability of a mirrorless laser by photon confinement due to Anderson localization.
Resumo:
This paper presents the design and implementation of a reorientable scanning probe that is capable of two-axis force sensing and control in the 2-D scanning (X-Z) plane. The probe is comprised of three major components, namely a compliant manipulator, laser measurement system, and magnetic actuation system. Control of the position and orientation of the probe tip is realized by means of magnetic actuation combined with a novel structural design. The design of the manipulator's compliance and that of the optical path of the laser measurement system together enable achieving sensitivity to lateral (X) forces that is nearly identical to that of normal (Z) forces. The achieved sensitivity ratio, of about 0.6, is significantly higher than that of conventional scanning probe systems. The theoretical bases for the structural design and the sensitivity of the two-axis force sensing system are presented. Subsequently, fabrication of the manipulator is described and the result of experimental evaluation of the scanning probe's features is discussed. The scanning probe is used to access the vertical and re-entrant features on the two sides of a cylindrical micropipette, which are subsequently scanned by regulating the lateral force of tip-sample interaction.
Resumo:
The gas-phase infrared spectra of 1,2-ED and 1,4-BD have been, recorded at three different temperatures using a multipass gas cell of 6 m optical path length. DFT calculation has also been carried out using 6-311++G** and aug-cc-pVDZ basis sets to look for the existence of intramolecular hydrogen bonding, in them from the red shift and infrared absorption intensity enhancement of the bonded O-H band compared to that of the free O-H hand. Equilibrium population analysis With 10 conformers of 1,2-ED and 1,4-BD at experimental temperatures were-carried out for the reconstruction of the Observed vibrational spectra at that temperature,using standard statistical relationships. The most abundant conformer at experimental temperatures, was identified. In 1,2-ED a red shift of 45 cm(-1) in the intramolecularly interacting O-H stretching vibrational band position and no significant intensity enhancement compared to that of-the free O-H have been observed. On the contrary, in one of the hydrogen bonded conformers of 1,4-BD, a 124 cm(-1) red shift in the O-H stretching frequency and 8.5 times-intensity enhancement for the ``bonded'' O-H compared to that of the ``free'' O-H is seen. On the basis of this comparative study, we have concluded that strong intramolecular hydrogen bonding exists in 1,4-BD. But there appears, to be weak intramolecular hydrogen bonding in 1,2-ED at temperatures of 303, 313, and 323 Km the gas phase We have found that most stable hydrogen-bonded conformers of 1,4-BD are less populated than some of the non-hydrogen-bonded conformers. Even for the 1,4-BD, the relative population of the g'GG'Gt conformer, which has a strong intramolecular,hydrogen bond, is less than what is predicted. Perhaps the intramolecular hydrogen bond plays a less Significant role in the relative stability,of the various Conformers than what has been predicted from calculations and prevails in the literature.
Resumo:
作为量子信息领域分支的鬼成像,由于物体的像将出现在不包含物体的光路上的特点,使得这一领域的研究引人入胜。一度认为,只有基于纠缠态双光子的纠缠光源,才能实现鬼成像;但近年来的研究表明,经典热光场也能实现这一过程。从经典统计光学入手,建立了热光场的数值模型,模拟符合热光特性的光场变化、光场传播、以及物体透射函数对热光场的调制,进而从光强度起伏的关联函数中,分别重现振幅型物体和纯相位型物体的傅里叶变换图像;通过与真实实验结果的对比,表明基于统计光学原理的该数值模型所预测的实验结果,与真实的实验结果完全一致。
Resumo:
A method using two prisms for measurement of small dynamic angles is proposed in which the measurement is based on a simple tangent equation and a phase-modulating interferometer with a laser diode to measure dynamic optical path differences with higher accuracy. Owing to the simple tangent equation, the symmetry requirement on the two prisms in the optical configuration is eliminated, and easy measurement of the separations between two parallel beams with a position-sensitive detector is achieved. Small-dynamic-angle measurements are experimentally demonstrated with high accuracy. (C) 2007 Society of Photo-Optical Instrumentation Engineers.
Resumo:
A method using two prisms for measurement of small dynamic angles is proposed in which the measurement is based on a simple tangent equation and a phase-modulating interferometer with a laser diode to measure dynamic optical path differences with higher accuracy. Owing to the simple tangent equation, the symmetry requirement on the two prisms in the optical configuration is eliminated, and easy measurement of the separations between two parallel beams with a position-sensitive detector is achieved. Small-dynamic-angle measurements are experimentally demonstrated with high accuracy. (C) 2007 Society of Photo-Optical Instrumentation Engineers.
Resumo:
在光纤无线电系统(ROF)中,提出了一种利用法布里-珀罗干涉仪来实现将一个光学脉冲转换为毫米波频率调制的光学脉冲的方法。在这种方法中,毫米波调制的频率是由法布里-珀罗干涉仪的腔长来决定的,而脉冲序列振幅衰减和能量转移效率则是由法布里-珀罗干涉仪的腔镜反射率决定的。同时,文中对输出脉冲宽度的扩展所导致的脉冲间的干涉问题也进行了详细阐述。
Resumo:
As there exist some problems with the previous laser diode (LD) real-time microvibration measurement interferometers, such as low accuracy, correction before every use, etc., in this paper, we propose a new technique to realize the real-time microvibration measurement by using the LD sinusoidal phase-modulating interferometer, analyze the measurement theory and error, and simulate the measurement accuracy. This interferometer utilizes a circuit to process the interference signal in order to obtain the vibration frequency and amplitude of the detective signal, and a computer is not necessary in it. The influence of the varying light intensity and light path difference on the measurement result can be eliminated. This technique is real-time, convenient, fast, and can enhance the measurement accuracy too. Experiments show that the repeatable measurement accuracy is less than 3.37 nm, and this interferometer can be applied to real-time microvibration measurement of the MEMS. (C) 2007 Elsevier GmbH. All rights reserved.
Resumo:
详细描述了用光纤耦合、波长复用的全息光盘仔储光路.指出在全息光盘驱动器即将市场化的今天.由于其光路简单、光学元件较少、性价比高.很有可能成为新的全息光盘驱动器的核心技术之一。由于短波长单模光纤及其双波长光纤分束器件的要求比较高.而用多模光纤进行准单模输出调整.以及用分光棱镜进行光束的分光.同时用对双波长敏感的光致聚合物材料进行存储.其光谱灵敏度均匀.光谱范围互不重叠。实验结果表明.光路结构合理.存储效果良好。
Resumo:
提出一种新型光束质量实时测量技术, 该技术主要基于由平板反射镜组成的多平面成像系统, 一次性将激光束腰附近2倍瑞利距离内的多个光斑成像在同一个平面上, 用CCD相机获取这些光斑的光强分布图样。通过图像处理获知接收到的光斑的光强分布。采用远场发散角、焦点尺寸、桶中功率比和M2因子四种光束质量评价标准对激光光束质量进行评价。利用该方法实时测量了高能钕玻璃双板条激光器的输出光束。