979 resultados para Fast test


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The conventional Newton and fast decoupled power flow (FDPF) methods have been considered inadequate to obtain the maximum loading point of power systems due to ill-conditioning problems at and near this critical point. It is well known that the PV and Q-theta decoupling assumptions of the fast decoupled power flow formulation no longer hold in the vicinity of the critical point. Moreover, the Jacobian matrix of the Newton method becomes singular at this point. However, the maximum loading point can be efficiently computed through parameterization techniques of continuation methods. In this paper it is shown that by using either theta or V as a parameter, the new fast decoupled power flow versions (XB and BX) become adequate for the computation of the maximum loading point only with a few small modifications. The possible use of reactive power injection in a selected PV bus (Q(PV)) as continuation parameter (mu) for the computation of the maximum loading point is also shown. A trivial secant predictor, the modified zero-order polynomial which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used in predictor step. These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approach for the IEEE test systems (14, 30, 57 and 118 buses) are presented and discussed in the companion paper. The results show that the characteristics of the conventional method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that parameters can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The parameterized fast decoupled power flow (PFDPF), versions XB and BX, using either theta or V as a parameter have been proposed by the authors in Part I of this paper. The use of reactive power injection of a selected PVbus (Q(PV)) as the continuation parameter for the computation of the maximum loading point (MLP) was also investigated. In this paper, the proposed versions obtained only with small modifications of the conventional one are used for the computation of the MLP of IEEE test systems (14, 30, 57 and 118 buses). These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approaches are presented and discussed. The results show that the characteristics of the conventional FDPF method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that these versions can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. A trivial secant predictor, the modified zero-order polynomial, which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used for the predictor step. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the best examinations used routinely to detect gastro-oesophageal reflux (GOR) is scintigraphy and attempts are continuously being made to improve the performance of the test. We have tested a new manoeuvre to improve the results. Three hundred and twenty eight patients (190 males and 138 females, aged 1 month to 84 years, average 4.47 years) were studied after a 12 h fast period with 100 MBq of Tc-99(m)-Phytate, 50 ml volume, directly delivered into the stomach in a mixture of orange juice. All patients were strongly suspected of having GOR. Conventional acquisition was done for 20 min, at a rate of one frame every 20 s. in the middle of the examination, small children were put in the upright position and held there for a few seconds or released in a way that allowed movement; adults were asked to stand up and walk a few metres. The test was then continued for the remaining 10 min. The global index of positivity was 64.6% (76 positive cases in the first half of the examination and 134 positive cases only after the manoeuvre). The mean of GOR episodes observed in the positive cases without the manoeuvre was 0.5 per patient, significantly different from the mean of 1.59 noted after the manoeuvre (P<0.01). In 28 cases the manoeuvre increased either the intensity or the frequency of reflux previously detected without it. We believe that this manoeuvre should be performed in all scintigraphic tests aiming to detect GOR. In the present series, the manoeuvre increased the frequency of GOR episodes. ((C) 2001 Lippincott Williams & Wilkins)].

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to propose an alternative method (MAOD(ALT)) to estimate the maximal accumulated oxygen deficit (MAOD) using only one supramaximal exhaustive test. Nine participants performed the following tests: (a) a maximal incremental exercise test, (b) six submaximal constant workload tests, and (c) a supramaximal constant workload test. Traditional MAOD was determined by calculating the difference between predicted O(2) demand and accumulated O(2) uptake during the supramaximal test. MAOD(ALT) was established by summing the fast component of excess post-exercise oxygen consumption and the O(2) equivalent for energy provided by blood lactate accumulation, both of which were measured during the supramaximal test. There was no significant difference between MAOD (2.82 +/- 0.45 L) and MAOD(ALT) (2.77 +/- 0.37 L) (p = 0.60). The correlation between MAOD and MAOD(ALT) was also high (r = 0.78; p = 0.014). These data indicate that the MAOD(ALT) can be used to estimate the MAOD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fast sequential multi-element determination of Ca, Mg, K, Cu, Fe, Mn and Zn in plant tissues by high-resolution continuum source flame atomic absorption spectrometry is proposed. For this, the main lines for Cu (324.754 nm), Fe (248.327 nm), Mn (279.482 nm) and Zn (213.857 nm) were selected, and the secondary lines for Ca (239.856 nm), Mg (202.582 nm) and K (404.414 nm) were evaluated. The side pixel registration approach was studied to reduce sensitivity and extend the linear working range for Mg by measuring at wings (202.576 nm; 202.577 nm; 202.578 nm; 202.580 nm: 202.585 nm; 202.586 nm: 202.587 nm; 202.588 nm) of the secondary line. The interference caused by NO bands on Zn at 213.857 nm was removed using the least-squares background correction. Using the main lines for Cu, Fe, Mn and Zn, secondary lines for Ca and K, and line wing at 202.588 nm for Mg, and 5 mL min(-1) sample flow-rate, calibration curves in the 0.1-0.5 mg L-1 Cu, 0.5-4.0 mg L-1 Fe, 0.5-4.0 mg L-1 Mn, 0.2-1.0 mg L-1 Zn, 10.0-100.0 mg L-1 Ca, 5.0-40.0 mg L-1 Mg and 50.0-250.0 mg L-1 K ranges were consistently obtained. Accuracy and precision were evaluated after analysis of five plant standard reference materials. Results were in agreement at a 95% confidence level (paired t-test) with certified values. The proposed method was applied to digests of sugar-cane leaves and results were close to those obtained by line-source flame atomic absorption spectrometry. Recoveries of Ca, Mg, K, Cu, Fe, Mn and Zn in the 89-103%, 84-107%, 87-103%, 85-105%, 92-106%, 91-114%, 96-114% intervals, respectively, were obtained. The limits of detection were 0.6 mg L-1 Ca, 0.4 mg L-1 Mg, 0.4 mg L-1 K, 7.7 mu g L-1 Cu, 7.7 mu g L-1 Fe, 1.5 mu g L-1 Mn and 5.9 mu g L-1 Zn. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Se1-yTey and Ge1-ySnySe2.5 glasses, with compositions Y less than or equal to 0.5 and Y less than or equal to 0.6 respectively, are investigated. These glasses show a glass transition temperature (T-g) above the stability limit, indicated by the Adiabatic Nucleation Model (ANM). This effect has to be so because, other-wise, when cooled, these undercooled liquids would crystallize by generalized nucleation near the stability limit and no T-g could be observed. This shows that Se1-yTey glasses for Y < 0.5 are structurally stable. Limiting cases are pure Te and Se50Te50, which have T'(g)'s on the stability limit. Pure amorphous Te has to be obtained by fast quenching techniques, where the effective (fast quenching) T-g(*) is higher and Se50Te50 tends to crystallize easily. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The urinary excretion, renal clearance, and tubular reabsorption of zinc were investigated in 30 adult healthy subjects under basal conditions and during the zinc and glucose tolerance tests. After a 12h overnight fast, each subject was submitted to renal clearance of zinc. The procedures were performed between 8.00 and 12.00 a.m., after emptying the bladder and ingestion of 4 ml deionized water/kg body weight at 8.00 a.m. The first urine sample was collected at 10.00 a.m., and the second at 12.00 a.m. A dose of 110 mg ZnSO4.7H(2)O was administered orally to each subject, diluted in 20 mi deionized water, at time 0 min. Blood samples were collected from an antecubital vein at times -30, 0, and 30 min and at 30 min intervals up to 240 min. Glucose was administered intravenously (0.5 ml 50%/kg body weight) during the first 3 min of the test, and blood samples were collected from an unconstricted, contralateral, antecubital vein at times -30, 0, 3, 5, 10, 20, 30, 45, 60, and 90 min. The results showed that urinary zinc excretion, and renal zinc clearance were significantly higher during the zinc and glucose tolerance tests than in the control condition. on the other hand, renal zinc clearance was more elevated during the glucose tolerance test than during the zinc tolerance test. Variations in zinc tubular reabsorption and glomerular filtration rate were not detected. The results suggest that urinary excretion and renal clearance of zinc in healthy subjects increase during acute zinc ingestion and glucose infusion. Although zinc ingestion raised urinary zinc excretion, glucose infusion was more effective in increasing renal zinc clearance. These normal parameters are important in the investigation of diabetic patients with serum and urine zinc changes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The urinary excretion, renal clearance, and tubular reabsorption of zinc were investigated in 30 adult healthy subjects under basal conditions and during the zinc and glucose tolerance tests. After a 12h overnight fast, each subject was submitted to renal clearance of zinc. The procedures were performed between 8.00 and 12.00 a.m., after emptying the bladder and ingestion of 4 ml deionized water/kg body weight at 8.00 a.m. The first urine sample was collected at 10.00 a.m., and the second at 12.00 a.m. A dose of 110 mg ZnSO47H2O was administered orally to each subject, diluted in 20 ml deionized water, at time 0 min. Blood samples were collected from an antecubital vein at times -30, 0, and 30 min and at 30 min intervals up to 240 min. Glucose was administered intravenously (0.5 ml 50%/kg body weight) during the first 3 min of the test, and blood samples were collected from an unconstricted, contralateral, antecubital vein at times -30, 0, 3, 5, 10, 20, 30, 45, 60, and 90 min. The results showed that urinary zinc excretion, and renal zinc clearance were significantly higher during the zinc and glucose tolerance tests than in the control condition. On the other hand, renal zinc clearance was more elevated during tile glucose tolerance test than during the zinc tolerance test. Variations in zinc tubular reabsorption and glomerular filtration rate were not detected. The results suggest that urinary excretion and renal clearance of zinc in healthy subjects increase during acute zinc ingestion and glucose infusion, Although zinc ingestion raised urinary zinc excretion, glucose infusion was more effective in increasing renal zinc clearance. These normal parameters are important in the investigation of diabetic patients with serum and urine zinc changes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new protocol using 3-h fast animal for intestinal motility test was developed in our laboratory aiming the 3R's concept to reduce the stress of animals. Our results may aid in formulating recommendations that can be included in revised guidelines with regard to fasting time of mice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the work described in the present paper, an analytical solution of the general heat conduction equation was employed to assay the temperature profile inside a solid slab which is initially at room temperature and is suddenly plunged into a fluid maintained at a high temperature. The results were then extrapolated to a simulation of a hot modulus of rupture test of typical MgO-graphite refractory samples containing different amounts of graphite in order to evaluate how fast the temperature equilibrates inside the test specimens. Calculations indicated that, depending on the graphite content, the time to full temperature homogenization was in the range of 80 to 200 s. These findings are relevant to the high temperature testing of such refractories in oxidizing conditions in view of the graphite oxidation risks in the proper evaluation of the hot mechanical properties.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: This study was undertaken to test the hypothesis that diabetes and pregnancy detrimentally affect the normal function of urethral striated muscles in rats, providing a model for additional studies related to urinary incontinence. The aim of this study was to evaluate morphological alterations in the urethral striated muscles of diabetic pregnant rats. Materials and Methods: Twenty female Wistar rats were distributed into four experimental groups of five rats as follows: virgin, pregnant, diabetic virgin, and diabetic pregnant. Diabetes was induced using streptozotocin administration (40 mg/kg i.v.). The rats were lethally anesthetized, and the urethra and vagina were extracted as a unit. Cryostat sections (6 μm thick) were cut and stained with hematoxylin-eosin, and immunohistochemical procedures were performed and subjected to morphological and semi quantitative analysis. Results: The urethral striated muscle from the diabetic pregnant rats presented with the following variations: thinning and atrophy, disorganization and disruption associated with the colocalization of fast and slow fibers and a steady decrease in the proportion of fast vs slow fibers. Conclusion: Diabetes and pregnancy impair the urethral striated muscle and alter its fiber type distribution. © Copyright G. Marini et al., 2011.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effectiveness of a new management tool for screening refrigerated raw milk quality in a dairy industry is provided. Three hundred and seventy-four samples of raw milk from individual producers and 125 samples from bulk milk carriers from the same producers were analyzed. Producers' samples underwent a fast tube reduction test, or Tetra-Test, to estimate total bacteriological charge and their predominant microbiota. Bulk milk samples underwent standard plate count (SPC) as reference method. Tetra-test was effective in screening and assessing the microbiological quality of refrigerated raw milk, since 82.4% of samples with more than 106UFC/mL were readily detected (5 minutes to 2h). The test may be employed as a management tool either in screening or in interventions on the detected problem. In fact, its results provided complementary information on the characteristics of dominant microbiota. Most samples failed in compliance to IN 51 requirements. Further, 211 samples (56.4%) showed high microbial charge and, consequently, poor quality raw milk. Psychrotrophic groups were not yet the main degrading factors of cooled raw milk, albeit present in 76.8% of samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)