999 resultados para Contamination (Technology)
Resumo:
The purpose of this study was to present a methodology with superior efficiency for inactivating pathogenic indicators commonly found in domestic sewage. The adopted method was based on synergistic effect resulting from the introduction of a UV radiation pre-disinfection stage of sewage followed by secondary treatment. A pilot unit was installed in the sewage treatment plant of the University of Sao Paulo to simulate the combined system in full-scale operational conditions. Its performance was evaluated through microbiological examinations for determining Escherichia coli, total coliforms and coliphages. The application of UV radiation at 5.1mW/cm(2) for 10 s of exposure in the first disinfection stage was enough to reduce the surviving number of E. coli around 100 times, in comparison to the conventional method. Therefore, based on experimental data, it is possible to conclude that combining treatment and pre-disinfection stage is an effective potential technique to produce effluents with lower degree of contamination by pathogenic organisms.
Resumo:
This paper presents a proposal for a Quality Management System for a generic GNSS Surveying Company as an alternative for management and service quality improvements. As a result of the increased demand for GNSS measurements, a large number of new or restructured companies were established to operate in that market. Considering that GNSS surveying is a new process, some changes must be performed in order to accommodate the old surveying techniques and the old fashioned management to the new reality. This requires a new management model that must be based on a well-described procedure sequence aiming at the Total Management Quality for the company. The proposed Quality Management System was based on the requirements of the Quality System ISO 9000:2000, applied to the whole company, focusing on the productive process of GNSS surveying work.
Resumo:
Considering the increasing popularity of network-based control systems and the huge adoption of IP networks (such as the Internet), this paper studies the influence of network quality of service (QoS) parameters over quality of control parameters. An example of a control loop is implemented using two LonWorks networks (CEA-709.1) interconnected by an emulated IP network, in which important QoS parameters such as delay and delay jitter can be completely controlled. Mathematical definitions are provided according to the literature, and the results of the network-based control loop experiment are presented and discussed.
Resumo:
This work presents a case study on technology assessment for power quality improvement devices. A system compatibility test protocol for power quality mitigation devices was developed in order to evaluate the functionality of three-phase voltage restoration devices. In order to validate this test protocol, the micro-DVR, a reduced power development platform for DVR (dynamic voltage restorer) devices, was tested and the results are discussed based on voltage disturbances standards. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
A green ceramic tape micro-heat exchanger was developed using Low Temperature Co-fired Ceramics technology (LTCC). The device was designed by using Computational Aided Design software and simulations were made using a Computational Fluid Dynamics package (COMSOL Multiphysics) to evaluate the homogeneity of fluid distribution in the microchannels. Four geometries were proposed and simulated in two and three dimensions to show that geometric details directly affect the distribution of velocity in the micro-heat exchanger channels. The simulation results were quite useful for the design of the microfluidic device. The micro-heat exchanger was then constructed using the LTCC technology and is composed of five thermal exchange plates in cross-flow arrangement and two connecting plates, with all plates stacked to form a device with external dimensions of 26 x 26 x 6 mm(3).
Resumo:
The application of airborne laser scanning (ALS) technologies in forest inventories has shown great potential to improve the efficiency of forest planning activities. Precise estimates, fast assessment and relatively low complexity can explain the good results in terms of efficiency. The evolution of GPS and inertial measurement technologies, as well as the observed lower assessment costs when these technologies are applied to large scale studies, can explain the increasing dissemination of ALS technologies. The observed good quality of results can be expressed by estimates of volumes and basal area with estimated error below the level of 8.4%, depending on the size of sampled area, the quantity of laser pulses per square meter and the number of control plots. This paper analyzes the potential of an ALS assessment to produce certain forest inventory statistics in plantations of cloned Eucalyptus spp with precision equal of superior to conventional methods. The statistics of interest in this case were: volume, basal area, mean height and dominant trees mean height. The ALS flight for data assessment covered two strips of approximately 2 by 20 Km, in which clouds of points were sampled in circular plots with a radius of 13 m. Plots were sampled in different parts of the strips to cover different stand ages. The clouds of points generated by the ALS assessment: overall height mean, standard error, five percentiles (height under which we can find 10%, 30%, 50%,70% and 90% of the ALS points above ground level in the cloud), and density of points above ground level in each percentile were calculated. The ALS statistics were used in regression models to estimate mean diameter, mean height, mean height of dominant trees, basal area and volume. Conventional forest inventory sample plots provided real data. For volume, an exploratory assessment involving different combinations of ALS statistics allowed for the definition of the most promising relationships and fitting tests based on well known forest biometric models. The models based on ALS statistics that produced the best results involved: the 30% percentile to estimate mean diameter (R(2)=0,88 and MQE%=0,0004); the 10% and 90% percentiles to estimate mean height (R(2)=0,94 and MQE%=0,0003); the 90% percentile to estimate dominant height (R(2)=0,96 and MQE%=0,0003); the 10% percentile and mean height of ALS points to estimate basal area (R(2)=0,92 and MQE%=0,0016); and, to estimate volume, age and the 30% and 90% percentiles (R(2)=0,95 MQE%=0,002). Among the tested forest biometric models, the best fits were provided by the modified Schumacher using age and the 90% percentile, modified Clutter using age, mean height of ALS points and the 70% percentile, and modified Buckman using age, mean height of ALS points and the 10% percentile.
Resumo:
A dynamic systems simulation model of water resources was developed as a tool to help analyze alternatives to water resources management for the Piracicaba, Capivari and Jundiai River Water Basins (RB-PCJ), and used to run six 50-year simulations from 2004 to 2054. The model estimates water supply and demand, as well as contamination load by several consumers. Six runs were performed using a constant mean precipitation value, changing water supply and demand and different volumes diverted from RB-PCJ to RB-Alto Tiet. For the Business as Usual scenario, the Sustainability Index went from 0.44 in 2004 to 0.20 by 2054. The Water Sustainability Index changed from 74% in 2004 to 131% by 2054. The Falkenmark Index changed from 1,403 m(3) person (-aEuro parts per thousand 1) year (-aEuro parts per thousand 1) in 2004 to 734 m(3) person (-aEuro parts per thousand 1) year (-aEuro parts per thousand 1) by 2054. We concluded that sanitation is one of the major problems for the PCJ River Basins.
Resumo:
Imaging Spectroscopy (IS) is a promising tool for studying soil properties in large spatial domains. Going from point to image spectrometry is not only a journey from micro to macro scales, but also a long stage where problems such as dealing with data having a low signal-to-noise level, contamination of the atmosphere, large data sets, the BRDF effect and more are often encountered. In this paper we provide an up-to-date overview of some of the case studies that have used IS technology for soil science applications. Besides a brief discussion on the advantages and disadvantages of IS for studying soils, the following cases are comprehensively discussed: soil degradation (salinity, erosion, and deposition), soil mapping and classification, soil genesis and formation, soil contamination, soil water content, and soil swelling. We review these case studies and suggest that the 15 data be provided to the end-users as real reflectance and not as raw data and with better signal-to-noise ratios than presently exist. This is because converting the raw data into reflectance is a complicated stage that requires experience, knowledge, and specific infrastructures not available to many users, whereas quantitative spectral models require good quality data. These limitations serve as a barrier that impedes potential end-users, inhibiting researchers from trying this technique for their needs. The paper ends with a general call to the soil science audience to extend the utilization of the IS technique, and it provides some ideas on how to propel this technology forward to enable its widespread adoption in order to achieve a breakthrough in the field of soil science and remote sensing. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
Linguica is a highly popular and appreciated pork product in Brazil, frequently consumed undercooked. Aiming at collection of data for a future risk assessment, this study evaluated the prevalence and counts of Listeria monocytogenes in linguica samples collected at retail level in Sao Paulo, SP, Brazil. ISO methods were used for detection and enumeration of the pathogen (11290-1 and 11290-2, respectively). Isolates were submitted to Simplex-PCR for hlyA gene and those with biochemical features of L. monocytogenes and hlyA positive were serotyped using a Multiplex PCR. Ninety percent of the samples were positive for Listeria spp., and L monocytogenes was detected in 42% of the samples, with counts below 10(2) CFU/g in all samples. A prevalence of uncommon serotypes 4a and 4c was observed. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Staphylococcus aureus is one of the most important infectious mastitis causative agents in small ruminants. In order to know the distribution of Staph. aureus strains associated with infectious mastitis in flocks of sheep in the northeast of Brazil and establish whether these clones are related to the strains distributed internationally, this study analysed the genetic diversity of Staph. aureus isolates from cases of clinical and subclinical mastitis in ewes by pulsed-field gel electrophoresis (PFGE) and multilocus sequence typing (MLST). In this research, 135 ewes with mastitis from 31 sheep flocks distributed in 15 districts were examined. Staph. aureus was isolated from sheep milk in 9 (29%) out of 31 herds located in 47% of the districts surveyed. MLST analysis allowed the identification of four STs (ST750, ST1728, ST1729 and ST1730). The last three with their respective novel alleles (g/p-220; pta-182 and yqil-180) were recently reported in the Staph. aureus MLST database (http://www.mlst.net). Each novel allele showed only a nucleotide different from those already described. The occurrence of CC133 (ST750 and ST1729) in this study is in agreement with other reports that only a few clones of Staph. aureus seem to be responsible for most cases of mastitis in dairy farms and that some of these clones may have broad geographic distribution. However, the prevalence of CC5 (ST1728 and ST1730)-an important group related to cases of colonization or infection in humans-differs from previous studies by its widespread occurrence and may suggest human contamination followed by selective pressures of the allelic diversifications presented for these STs.
Resumo:
In this study, 20 Brazilian public schools have been assessed regarding good manufacturing practices and standard sanitation operating procedures implementation. We used a checklist comprised of 10 parts ( facilities and installations, water supply, equipments and tools, pest control, waste management, personal hygiene, sanitation, storage, documentation, and training), making a total of 69 questions. The implementing modification cost to the found nonconformities was also determined so that it could work with technical data as a based decision-making prioritization. The average nonconformity percentage at schools concerning to prerequisite program was 36%, from which 66% of them own inadequate installations, 65% waste management, 44% regarding documentation, and 35% water supply and sanitation. The initial estimated cost for changing has been U.S.$24,438 and monthly investments of 1.55% on the currently needed invested values. This would result in U.S.$0.015 increase on each served meal cost over the investment replacement within a year. Thus, we have concluded that such modifications are economically feasible and will be considered on technical requirements when prerequisite program implementation priorities are established.
Resumo:
The objective of the present study was to evaluate the occurrence of Salmonella spp. in 15 samples of pork meat cuts (T-bone, shank, sausage and ribs) commercialized in open markets of Pelotas (RS, Brazil) and verify the prevalent serovars, and test the isolates profile of sensitivity to several antibiotics of importance in medicine (nalidixic acid, ampicillin, aztreonam, kanamycin, carbenicillin, cephalothin, cefoxitin, ceftriaxone, ciprofloxacin, chloramphenicol, gentamicin, sulfonamide, tetracycline and trimetoprina). Twelve samples (80%) were contaminated by Salmonella enterica, serovars Infantis, Derby, Panama and Typhimurium. All isolates were susceptible to trimetoprin, aztreonam, ciprofloxacin, ceftriaxone and cefoxitin. For the other antibiotics, the pattern of sensitivity varied as serovar. In addition, 39.1% of isolates showed up to be multiresistant.
Resumo:
Sao Paulo state, Brazil, is one of the main areas of sugar cane agriculture in the world. Herbicides, in particular, ametryn, are extensively used in this extensive area, which implies that this herbicide is present in the environment and can contaminate the surface water by running off. Thereby, residues of ametryn were analyzed in samples of river water an river sediment and in freshwater bivalves obtained from the rivers Sapucai, Pardo and Mogi-Guacu in Sao Paulo State, Brazil. Samples were taken in the winter of 2003 and 2004 in two locations in each river. The specimens of freshwater bivalves collected and analyzed were Corbicula fluminea, an exotic species, and Diplodon fontaineanus, a native species. Additionally, the evaluation of the ability of bioconcentration and depuration of ametryn by the freshwater bivalve Corbicula fluminea was also performed. Ametryn concentrations in the samples were measured by liquid chromatography coupled to mass spectrometry. Residues of ametryn in water (50 ng/L) and in freshwater bivalves (2-7 ng/g) were found in the Mogi-Guacu River in 2004, and residues in river sediments were found in all rivers in 2003 and 2004 (0.5-2 ng/g). The observation of the aquatic environment through the analysis of these matrixes, water, sediment, and bivalves, revealed the importance of the river sediment in the accumulation of the herbicide ametryn, which can contaminate the biota.
Resumo:
Minimally processed refrigerated ready-to-eat fishes may offer health risk of severe infection to susceptible individuals due to contamination by the psychrotolerant bacterium L monocytogenes. In this work, inhibition of L monocytogenes by a plant extract and lactic acid bacteria (IAB) was studied in model fish systems kept at 5 degrees C for 35 days. For that, fillets of tropical fish ""surubim"" (Pseudoplatystoma sp.) and hydroalcoholic extract of the plant Lippia sidoides Cham. (""alecrim pimenta"") were used. Fish peptone broth (FPB), ""surubim"" broth and ""surubim"" homogenate were inoculated with combinations of L monocytogenes and bacteriocin-producing Carnobacterium maltaromaticum (C2 and A9b(+)) and non bacteriocin-producing C. maltaromaticum (A9b(-)), in the presence or absence of extract of ""alecrim pimenta"" (EAP). In all model systems, monocultures of L monocytogenes and carnobacteria reached final populations >= 10(8) CFU/ml after 35 days, except for L monocytogenes in ""surubim"" homogenate (10(4) CFU/ml). In FPB, EAP alone and combined with cultures of LAB inhibited L monocytogenes but carnobacteria without EAP were only weakly antilisterial. In ""surubim"" broth, EAP alone did not prevent L monocytogenes growth but cultures of carnobacteria combined or not with EAP inhibited L monocytogenes, with more pronounced effect being observed for C maltaromaticum C2, which produced bacteriocin. In ""surubim"" homogenate, EAP alone and combined with cultures of C. maltaromaticum A9b(-) and A9b(+) were strongly inhibitory to L monocytogenes, while C maltaromaticum C2 with EAP caused transient inhibition of L monocytogenes. No significant inhibition of L monocytogenes was observed for carnobacteria in ""surubim"" homogenate without EAP. In conclusion, it was observed that the use of EAP and cultures of carnobacteria have potential to inhibit L monocytogenes in fish systems and the applications should be carefully studied, considering the influence of food matrix. (c) 2011 Elsevier B.V. All rights reserved.
Resumo:
P>With the evidence showing the protection variability of bacille Calmette-Guerin, new potential vaccines for tuberculosis have been tested around the world. One of the general concerns in tuberculosis vaccine development is the possibility of priming the host immune system with prior exposure to environmental mycobacteria antigens, which can change the efficacy of subsequent vaccination. As there is a great homology between the species from Mycobacterium genera, the previous contact of experimental animals with environmental mycobacteria could sensitize the mice and, in this way, could influence subsequent vaccine research. The aim of our study was to investigate critical points in an animal facility to search for environmental mycobacteria that eventually could be in direct or indirect contact with the experimental animals. Samples were collected from surfaces of walls, floor, animal cages and shelves and analysed using the Ogawa-Kudoh decontamination method. Samples of drinking water, food and sawdust were collected for analysis by the NALC/NaOH decontamination method. Also, the samples were cultivated directly in broth medium, without any method for decontamination. After decontamination methods, we observed bacterial colony growth in 4.31% of the total of samples analysed. These samples were stained with Ziehl-Neelsen and we did not detect any acid-fast bacilli, suggesting that the animal facility analysed is free from contamination by environmental mycobacteria and is not a source of mycobacterial antigens. Furthermore, our study showed a new paradigm in tuberculosis vaccine development: concern about the animal facility environment in terms of immune system priming of experimental animals by nascent bacterial contaminants.