975 resultados para Biodegradable Medical Devices
Resumo:
An aneurysm is a localized blood-filled dilatation of an artery whose consequences can be deadly. One of its current treatments is endovascular aneurysm repair, a minimally invasive procedure in which an endoprosthesis, called a stent-graft, is placed transluminally to prevent wall rupture. Early stent-grafts were custom designed for the patient through the assembling of off-the-shelf components by the operating surgeon. However, nowadays, stent-grafts have become a commercial product. The existing endoprostheses differ in several aspects, such as shape design and materials, but they have in common a metallic scaffold with a polymeric covering membrane. This article aims to gather relevant information for those who wish to understand the principles of stent-grafts and even to develop new devices. Hence, a stent-graft classification based on different characteristics is presented and the desired features for an ideal device are pointed out. Additionally, the materials currently in use to fabricate this type of endoprosthesis are reviewed and new materials are suggested.
Resumo:
Com o crescente aumento da Teleradiologia, sentiu-se necessidade de criar mais e melhores softwares para sustentar esse crescimento. O presente trabalho pretende abordar a temática da certificação de software e a sua marcação CE, pois para dar entrada no mercado Europeu todos os Dispositivos Médicos (DM) têm de estar devidamente certificados. Para efetuar a marcação CE e a certificação serão estudadas normas e normativos adequados para marcação de DM ao nível Europeu e também dos Estados Unidos da América. A temática da segurança de dados pessoais será também estudada de forma a assegurar que o dispositivo respeite a legislação em vigor. Este estudo tem como finalidade a certificação de um software proprietário da efficientia sysPACS, um serviço online abrangente, que permite a gestão integrada do armazenamento e distribuição de imagens médicas para apoio ao diagnóstico.
Resumo:
A melhoria progressiva na prestação de cuidados de saúde que se verifica nos dias de hoje, deve-se maioritariamente ao desenvolvimento de novas tecnologias médicas, que se traduzem na criação de inovadores dispositivos médicos, cujo fim é auxiliar no diagnóstico, prevenção e tratamento de doenças, melhorando assim as condições de trabalho e os cuidados oferecidos aos pacientes. No entanto estas melhorias apenas são vantajosas quando as novas tecnologias são utilizadas de forma segura, o que leva a uma preocupação crescente com a segurança dos profissionais de saúde e dos pacientes em ambiente hospitalar. Como forma de reduzir e controlar os riscos existentes, as unidades de saúde introduziram mecanismos de gestão que permitem o conhecimento das fontes de risco e respetivos mecanismos de ação. A presente dissertação de mestrado apresenta uma proposta de modelo de Manual de Procedimentos para Gestão de Risco de Dispositivos Médicos, aplicável a todos os dispositivos médicos existentes nas Unidades de Saúde. Para a criação deste manual, foram utilizados por meio de adaptação, as etapas da gestão de risco definidas na Norma ISO 14971:2007 em conjunto com o método de gestão de risco utilizado pela Unidade Local de Saúde de Matosinhos O desenvolvimento deste manual de procedimentos permitirá a esta unidade de saúde, a aquisição e fornecimento de informações úteis na tomada de decisão sobre os procedimentos de controlo de risco de dispositivos médicos, com o objetivo de manter o risco destes dispositivos dentro dos níveis previamente estabelecidos e auxiliar a tomada de decisão de programas de manutenção preventiva e de aquisição de dispositivos médicos.
Resumo:
Biomaterials have been extensively developed and applied in medical devices. Among these materials, bioabsorbable polymers have attracted special attention for orthopedic applications where a transient existence of an implant can provide better results, when compared with permanent implants. Chitosan, a natural biopolymer, has generated enormous interest due to its various advantages such as biocompatibility, biodegradability and osteoconductive properties. In this paper, an assessment of the potential of a developed innovative production process of 3D solid and dense chitosan-based products for biomedical applications is performed and presented. Therefore, it starts with a brief explanation of the technology, highlighting its main features. Then, several potential applications and their markets were identified and assessed. After choosing a primary application and market, its potential as well as its uncertainties and risks were identified. A business model suggesting how to materialize the value from the application was sketched. After that, a brief description of the market as well as the identification of the main competitors and their distinctive features was made. The supply chain analysis and the go-to-market strategy were the following steps. In the end, a final recommendation based on the assessment of the information was prepared.
Resumo:
Dissertação apresentada ao Instituto Superior de Administração e Contabilidade do Porto para obtenção do Grau de Mestre em Logística Orientada por: Professora Doutora Maria Clara Rodrigues Bento Vaz Fernandes
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
A crescente incorporação das evoluções tecnológicas nos equipamentos médicos modernos, além de os tornar mais compactos e precisos, proporciona igualmente ganhos de outros benefícios importantes, especialmente ao nível da eficiência das terapias prescritas aos pacientes. Os sofisticados ventiladores pulmonares de cuidados intensivos do presente espelham perfeitamente esta realidade e por isso necessitam de procedimentos técnicos de verificação metrológica – calibrações, também eles mais exatos e rastreáveis, de modo a fornecerem informações corretas sobre se o estado de funcionamento de um determinado ventilador cumpre ou não as tolerâncias declaradas pelo seu fabricante. Através da presente dissertação pretendeu-se desenvolver um procedimento técnico de calibração dos ventiladores de cuidados intensivos tendo-se estudado, para esta finalidade, os equipamentos de calibração específicos disponíveis no mercado, a normalização e o enquadramento regulamentar do controlo metrológico aplicáveis, bem como o princípio de funcionamento do ventilador pulmonar e a evolução da ventilação mecânica ocorrida. No domínio da abordagem efetuada sobre o âmbito da metrologia, implementou-se a determinação das incertezas dos resultados das calibrações efetuadas pelo procedimento técnico desenvolvido, de acordo com a metodologia constante do GUM1. Considerando ainda os défices significativos de conhecimento da metrologia e da prática do controlo metrológico no setor da saúde, a par dos riscos inerentes para os próprios pacientes, procura-se contribuir com este trabalho, de uma forma transversal e ampla, para uma maior consciencialização, quer dos profissionais de saúde, quer dos gestores envolvidos, para a relevância da realização das calibrações periódicas dos complexos equipamentos de suporte de vida que são os ventiladores pulmonares de cuidados intensivos.
Resumo:
Fundação para a Ciência e a Tecnologia (FCT-MCTES) under the grant SFRH/BD/69306/2010
Resumo:
Staphylococcus epidermidis is a biofilm - forming bacterium and a leading etiological agent of nosocomial infections. The ability to establish biofilms on indwelling medical devices is a key virulence factor for this bacterium. Still, the influence of poly - N - acetyl glucosamine (PNAG), the major component of the extracellular biofilm matrix, in the host immune response has been scarcely studied. Here, t h is influence was assessed in mice challenged i.p. with PNAG - p roducing (WT) and isogenic - mutant lacking PNAG (M10) bacteria grown in biofilm - inducing conditions. Faster bacterial clearance was observed in the mice infected with WT bacteria than in M10 - infected counterparts , which w as accompanied by earlier neutrophil recruitment and higher IL - 6 production. Interestingly, in the WT - infected mice, but not in those infected with M10 , elevated serum IL - 10 was detected . To further study the effe ct of PNAG in the immune response, mice were primed with WT or M10 biofilm bacteria and subsequently infected with WT biofilm - released cells. WT - primed mice presented a higher frequency of splenic IFN - γ + and IL - 17 + CD4 + T cells, and more severe liver patho logy than M10 - primed counterparts. Nevertheless, T reg cells obtained from the WT - primed mice presented a higher suppressive function than those obtained from M10 - primed mice. This effect was abrogated when IL - 10 - deficient mice were similarly primed and infected indicating that PNAG promotes the differentiati on of highly suppressive T reg cells by a mechanism dependent on IL - 10. Altogether, these results provide evidence help ing explain ing the coexistence of inflammation and bacterial persistence often observed in biofilm - originated S. epidermidis infections
Resumo:
Coagulase-negative staphylococci (CoNS) are common bacterial colonisers of the human skin. They are often involved in nosocomial infections due to biofilm formation in indwelling medical devices. While biofilm formation has been extensively studied in Staphylococcus epidermidis, little is known regarding other CoNS species. Here, biofilms from six different CoNS species were characterised in terms of biofilm composition and architecture. Interestingly, the ability to form a thick biofilm was not associated with any particular species, and high variability on biofilm accumulation was found within the same species. Cell viability assays also revealed different proportions of live and dead cells within biofilms formed by different species, although this parameter was particularly similar at the intra-species level. On the other hand, biofilm disruption assays demonstrated important inter- and intra-species differences regarding extracellular matrix composition. Lastly, confocal laser scanning microscopy (CLSM) experiments confirmed this variability, highlighting important differences and common features of CoNS biofilms. We hypothesised that the biofilm formation heterogeneity observed was rather associated with biofilm matrix composition than with cells themselves. Additionally, our results indicate that polysaccharides, DNA and proteins are fundamental pieces in the process of CoNS biofilm formation.
Resumo:
Stents are rigid and perforated tubular structures, which are inserted into blood vessels in order to prevent or inhibit the constriction of blood flow, restoring the normal blood flow, when blood vessels are clogged, being used in 70% of angioplasties. These medical devices assume great importance in the treatment of cardiovascular diseases (CVD) which are the leading cause of death worldwide. In the European Union CVD account for 40% of deaths and assume an estimated annual cost of 196 billion euros[1]. Stents must possess certain requirements, in order to, adequately, perform its function, such as biocompatibility (so that its use does not c ause damage on the health of its user), mechanical strength, radiopacity (so that it is easy to view), longitudinal flexibility, ease of handling, corrosion resistance and having high strength and high radial expansion ability to recover. Stents can be made of different materials, but metals, particularly stainless steel, are the most common. However, metallic stents present several dRawbacks such as corrosion and restenosis, leading to health complications for the patient, or even death. In order to minimize these disadvantages, new materials, like fibrous materials, have been used [2]. Monofilaments present high potential for stents development because, in addition to its biocompatibility, these materials allow the application of various surface treatments, such as antibacterial coatings. Furthermore, monofilament exhibit excellent mechanical properties, like greater stiffness and good results when subjected to compression, tensile and bending forces, since these forces will be directly supported by the monofilament [3]. To minimize the reaction of the human body and Limit the adhesion of microorganisms to the stent surface, some coatings have been developed, including the use of novel metals with antimicrobial properties, like silver. The main objective of this study was the development of fibrous stents, incorporation of silver oxide nanocoating. For the development of the stent, polyester monofilaments with 0.27mm of diameter were used in braiding technology, with a mandrel diameter of 6mm and a braiding angle of 35⁰. The mechanical behaviour of the stent were evaluated by mechanical testing under longitudinal and radial compression, bending. The results of compressive strength tests are according with value from literature: 1.13 to 2.9 N for radial compression and 0. 16-5.28N to longitudinal compression. From literature is also possible to verify that stents must present 75% of unchanged diameter during the bending test and must possess a porosity between 70% and 80% [4]. The produced polyester stent presents values of 1.29N for radial compression, 0.23N for longitudinal compression, 80% of porosity and 85.5% of unchanged diameter, during bending tests. For the antibacterial functionalization, silver oxide nanocoatings were prepared, through reactive magnetron g, with an Ag target in an Ar +O2 atmosphere. In order to evaluate the nanostructure and morphology of the coatings, d ifferent technique s like X-ray diffraction (XRD), scanning electron microscopy (SEM) and and X- ray photoelectron spectroscopy (XPS were used. From the analyses of XRD it is possible to verify that the peaks corresponds to planes of Ag2 O and MATERIAIS 2015 Porto, 21-23 June, 2015 characterize a cubic phase. The presence of Ag2 O is corroborated by XPS spectrum, where it is possible to observe silver, not only, in oxide state, but a lso in mettalic state, and it is possible to verify the presence of silver clusters, confirmed by SEM analysis. Films’ roughness and topography, parameters influencing the wettability of the surface and microorganism adhesion, were measured by Atomic Force Microscopy (AFM), and it was observed that the roughness is very low (under 10 nm). Coatings’ hydrophobicity and surface tension parameters were determined by contact angle measurement, and it was verified the hydrophobic behavior of the coatings. For antibacterial tests were used Staphylococcus epidermidis strain (IE186) and Staphylococcus aureus(ATCC 6538), and halo inhibition zone tests were realized. Ag+release rates were studied by means of inductively coupled plasma mass spectrometry (ICP -MS). The obtained results suggest that silver oxide coatings do not modify significantly surface properties of the substrate, like hydrophobicity and roughness, and present antimicrobial properties for both bacteria used.
Resumo:
Scientific and technological advancements in the area of fibrous and textile materials have greatly enhanced their application potential in several high-end technical and industrial sectors including construction, transportation, medical, sports, aerospace engineering, electronics and so on. Excellent performance accompanied by light-weight, mechanical flexibility, tailor-ability, design flexibility, easy fabrication and relatively lower cost are the driving forces towards wide applications of these materials. Cost-effective fabrication of various advanced and functional materials for structural parts, medical devices, sensors, energy harvesting devices, capacitors, batteries, and many others has been possible using fibrous and textile materials. Structural membranes are one of the innovative applications of textile structures and these novel building skins are becoming very popular due to flexible design aesthetics, durability, lightweight and cost benefits. Current demand on high performance and multi-functional materials in structural applications has motivated to go beyond the basic textile structures used for structural membranes and to use innovative textile materials. Structural membranes with self-cleaning, thermoregulation and energy harvesting capability (using solar cells) are examples of such recently developed multi-functional membranes. Besides these, there exist enormous opportunities to develop wide varieties of multi-functional membranes using functional textile materials. Additionally, it is also possible to further enhance the performance and functionalities of structural membranes using advanced fibrous architectures such as 2D, 3D, hybrid, multi-layer and so on. In this context, the present paper gives an overview of various advanced and functional fibrous and textile materials which have enormous application potential in structural membranes.
Resumo:
Nowadays, antibacterial properties are becoming a viable feature to be introduced in biomaterials due to the possibility of modifying the materials' surface used in medical devices in a micro/nano metric scale. As a result, it is mandatory to understand the mechanisms of the antimicrobial agents currently used and their possible failures. In this work, the antibacterial activity of ZrCNAg films is studied, taking into consideration the ability of silver nanoparticles to be dissolved when embedded into a ceramic matrix. The study focuses on the silver release evaluated by glow discharge optical emission spectroscopy and the effect of the fluid composition on this release. The results revealed a very low silver release of the films, leading to non-antibacterial activity of such materials. The silver release was found to be dependent on the electrolyte composition. NaCl (8.9 g L? 1) showed the lowest spontaneously silver ionization, while introducing the sulfates in Hanks' balanced salt solution (HBSS) such ionization is increased; finally, the proteins incorporated to the (HBSS) showed a reduction of the silver release, which also explains the low ionization in the culture medium (tryptic soy broth) that contains high quantities of proteins.
Resumo:
Objectives: This research work intends to clarify the role of artificial saliva, in particularly the role of mucin, a salivary protein, on the surface properties and adhesion ability of Candida spp. oral clinical isolates to abiotic surfaces. Methods: Four oral clinical isolates of Candida spp. were used: two Candida albicans strains (AC; AM) and two Candida parapsilosis strains (AD; AM2). The strains were isolated from patients using oral prosthesis. The microorganisms were cultured in the absence or presence of mucin and artificial saliva, and their adhesion to an abiotic surface (coated with mucin and artificial saliva) was evaluated. Results: The presence of mucin per se onto the abiotic surface decreased the adhesion of all strains, although the combination of mucin with artificial saliva had reduced this effect. No direct correlation between adhesion and the surface free energies of adhesion of the microorganisms was found. Significance: Candida spp. were human commensal microorganisms that became pathogenic when the host immune defenses were compromised. Medical devices were colonized by Candida spp. particularly, oral prostheses, which might lead to the degradation of the prostheses and systemic infections. The salivary secretions that constantly cover the oral cavity influenced Candida spp. adhesion process. Therefore, it was important to understand the interactions between Candida spp., salivary proteins and the characteristic of oral prosthesis when developing materials for oral prostheses.
Resumo:
Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Engenharia Clínica)