915 resultados para Anodic-dissolution


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cadmium UPD on Au was studied by voltammetric and microgravimetric measurements. In the oxide formation/reduction potential region, a mass increasing/decreasing of 32 ng cm-2 was associated to incorporation/elimination of one oxygen per active site. The modifications promoted in the voltammetric and mass profiles by 10-5 M Cd(ClO4)2 are restricted to potentials more negative than 0.4 V. After a 120 s potential delay at 0.05 V, the positive sweep reveals an anodic peak with charge of 40 muC cm-2 and mass decrease of 22 ng cm-2, associated to Cd ads dissolution. Sulphate or chloride was added to the solution without significant influence, due to the low coverage with Cd or anions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to develop and validate a dissolution test for glibenclamide tablets. Optimal conditions to carry out the dissolution test are 500 mL of phosphate buffer at pH 8.0, paddles at 75 rpm stirring speed, time test set to 60 min and using equipment with six vessels. The derivative UV spectrophotometric method for determination of glibenclamide released was developed, validated and compared with the HPLC method. The UVDS method presents linearity (r² = 0.9999) in the concentration range of 5-14 µg/mL. Precision and recoveries were 0.42% and 100.25%, respectively. The method was applied to three products commercially available on the Brazilian market.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dissolution test for telithromycin tablets was validated and developed. In order to choose the most discriminatory one, the conditions to carry out are 900 mL of sodium phosphate buffer at pH 7.5, paddles at 50 rpm stirring speed, time test set to 60 min and using USP apparatus 2 with paddles. The UV spectrophotometric method for determination of telithromycin released was developed and validated. The method presents linearity (r = 1) in the concentration range of 20-60 µg/mL. Precision and recoveries were good, 100.62 and 97.06%, respectively. The method was successfully used for the dissolution test of telithromycin tablets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was the development of a dissolution method for benznidazole (BNZ) tablets. Three different types of dissolution media, two stirring speeds and apparatus 2 (paddle) were used. The accomplishment of the drug dissolution profiles was compared through the dissolution efficiency. The assay was performed by spectrophotometry at 324 nm. The better conditions were: sodium chloride\hydrochloride acid buffer pH 1.2 with stirring speed of 75 rpm, volume of 900 mL and paddle as apparatus. Ahead of the results it can be concluded that the method developed consists in an efficient alternative for assays of dissolution for benznidazole tablets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the development and validation of a dissolution test for 50 mg losartan potassium capsules using HPLC and UV spectrophotometry. A 2(4) full factorial design was carried out to optimize dissolution conditions and potassium phosphate buffer, pH 6.8 as dissolution medium, basket as apparatus at the stirring speed of 50 rpm and time of 30 min were considered adequate. Both dissolution procedure and analytical methods were validated and a statistical analysis showed that there are no significant differences between HPLC and spectrophotometry. Since there is no official monograph, this dissolution test could be applied for quality control routine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aimed the development and validation of a new dissolution test for ornidazole coated tablets. The dissolution conditions were determined after testing Sink conditions, dissolution medium, apparatus, stirring speed, 24 h stability and medium filtration influence. The best conditions were paddle at a stirring speed of 75 rpm and 900 mL of 0.1 M HCl. A new HPLC quantification method was developed and validated. The dissolution test and quantification method showed to be adequate for their purposes and could be applied for quality control of ornidazole coated tablets, since there is no official monograph.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dissolution test for in vitro evaluation of tablet dosage forms containing 10 mg of rupatadine was developed and validated by RP-LC. A discriminatory dissolution method was established using apparatus paddle at a stirring rate of 50 rpm with 900 mL of deaerated 0.01 M hydrochloric acid. The proposed method was validated yielding acceptable results for the parameters evaluated, and was applied for the quality control analysis of rupatadine tablets, and to evaluate the formulation during an accelerated stability study. Moreover, quantitative analyses were also performed, to compare the applicability of the RP-LC and the LC-MS/MS methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple liquid chromatographic method was optimized for the quantitative determination of terbinafine in pharmaceutical hydroalcoholic solutions and tablets, and was also employed for a tablet dissolution test. The analysis was carried out using a RP-C18 (250 mm × 4.6 mm, 5 μm) Vertical® column, UV-Vis detection at 254 nm, and a methanol-water (95:5, v/v) mobile phase at a flow-rate of 1.2 mL min-1. Method validation investigated parameters such as linearity, precision, accuracy, robustness and specificity, which gave results within the acceptable range. The tablets dissolution was quite fast: 80% of the drug was dissolved within 15 min.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the development and validation of a dissolution test for 60 mg of diltiazem hydrochloride in immediate release capsules. The best dissolution in vitro profile was achieved using potassium phosphate buffer at pH 6.8 as the dissolution medium and paddle as the apparatus at 50 rpm. The drug concentrations in the dissolution media were determined by UV spectrophotometry and HPLC and a statistical analysis revealed that there were significant differences between HPLC and spectrophotometry. This study illustrates the importance of an official method for the dissolution test, since there is no official monograph for diltiazem hydrochloride in capsules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method using liquid chromatography has been developed and validated for determination of buclizine in pharmaceutical formulations and in release studies. Isocratic chromatography was performed on a C18 column with methanol:water (80:20 v/v, pH 2.6) as mobile phase, at a flow rate of 1.0 mL/min, and UV detection at 230 nm. The method was linear, accurate, precise, sensible and robust. The dissolution test was optimized and validated in terms of dissolution medium, apparatus agitation and rotation speed. The presented analytical and dissolution procedures can be conveniently adopted in the quality and stability control of buclizine in tablets and oral suspension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Commonly used HPLC acetonitrile solvent has been through a worldwide shortage with a cost increase in 2008 and 2009. In order to get around this situation, a method by RP-HPLC employing methanol and aqueous acid mobile phase was developed and validated to evaluate simvastatin. The quality control assay and dissolution studies of this lipid-lowering drug were performed in diluents methanol and 0.01 M phosphate buffer with 0.5% SDS, pH 7, respectively. Dissolution test aliquots did not go through sample treatment, as described in USP SIM tablets monograph by ultraviolet spectrophotometry. The proposed method is fast, simple, feasible and robust.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, precise, specific, repeatable and discriminating dissolution test for primaquine (PQ) matrix tablets was developed and validated according to ICH and FDA guidelines. Two UV assaying methods were validated for determination of PQ released in 0.1 M hydrochloric acid and water media. Both methods were linear (R²>0.999), precise (R.S.D.<1.87%) and accurate (97.65-99.97%). Dissolution efficiency (69-88%) and equivalence of formulations (f2) was assessed in different media and apparatuses (basket/100 rpm and paddle/50 rpm) tested. Discriminating condition was 900 mL aqueous medium, basket at 100 rpm and sampling times at 1, 4 and 8 h. Repeatability (R.S.D.<2.71%) and intermediate precision (R.S.D.<2.06%) of dissolution method were satisfactory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to develop and validate simple, accurate and precise spectroscopic methods (multicomponent, dual wavelength and simultaneous equations) for the simultaneous estimation and dissolution testing of ofloxacin and ornidazole tablet dosage forms. The medium of dissolution used was 900 ml of 0.01N HCl, using a paddle apparatus at a stirring rate of 50 rpm. The drug release was evaluated by developed and validated spectroscopic methods. Ofloxacin and ornidazole showed 293.4 and 319.6nm as λmax in 0.01N HCl. The methods were validated to meet requirements for a global regulatory filing. The validation included linearity, precision and accuracy. In addition, recovery studies and dissolution studies of three different tablets were compared and the results obtained show no significant difference among products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Svavel förekommer i kol och olja och oxideras vid förbränning till svaveldioxid (SO2). Årligen utsläpps stora mängder svaveldioxid som åstadkommer sura regn, minskning av stratosfäriskt ozon och sjukdomar. Av dessa orsaker är det nödvändigt att minska utsläppen av svaveldioxid. Den teknologi som rör planering av reaktorer och processer för rökgasavsvavling (FGD) har utvecklats kraftigt och idag använder man olika typer av lösningar. De vanligaste alternativen för FGD är våtskrubber- och semitorra skrubbersystem (Spray Dry Scrubbers, SDS) och injektionsprocesser för absorbenter. SDS-processer har studerats bland annat av Ahlbeck [4] och Klingspor [5] och injektionsprocesser av Alvfors [6]. Kalksten, som i huvusak består av kalciumkarbonat, används i rökgasavsvavling på grund av sin förmåga att binda svavel i form av sulfatsalter. Den vanligaste rökgasavsvavlingsmetoden är våtskrubbning, där det sedimentära stenmaterialets upplösningshastighet är en av de faktorer som påverkar resultatet mest. Utvärdering av kalkstensreaktivitet är därför speciellt viktig vid planering och drift av anläggningar för rökgasavsvavling. Målsättningen med detta arbete var att modellera upplösningen av olika typers kalksten för att få en kvantitativ utvärdering av kvaliteten på de analyserade proverna. Därtill testades även karbonatbiprodukter från stålindustrin för att utvärdera möjligheter att använda andra råmaterial. Det transienta förloppet har analyserats, varvid upplösningshastigheten modellerades bl.a. i avseende på tid och pH. Under arbetets gång har antalet empiriska korrelationer minskats till fördel för fysikaliska modeller av diffusiva och konvektiva masstransportfenomen. En målsättning var att skapa en effektiv och snabb metod för att testa olika absorbenter för rökgasavsvavling under transienta förlopp. I arbetet användes PSD-analys, gjordes pH-mätningar och andra utvärderingar av de fysikaliska parametrar som ingår i beräkningarna. On-line mätningar för de icke-stationära variablerna tid och pH ger möjlighet att eliminera osäkerheter. Vissa modeller kan vara komplicerade. En modell för upplösningshastigheten med mer detaljerad utvärdering av parametrar och färre approximationer är därför nödvändig då man vill utvärdera reaktionshastigheten för fasta partiklar i sur miljö. Arbetet utfördes under fyra år och fem peer review-artiklar ingår i avhandlingen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glass is a unique material with a long history. Several glass products are used daily in our everyday life, often unnoticed. Glass can be found not only in obvious applications such as tableware, windows, and light bulbs, but also in tennis rackets, windmill turbine blades, optical devices, and medical implants. The glasses used at present as implants are inorganic silica-based melt-derived compositions mainly for hard-tissue repair as bone graft substitute in dentistry and orthopedics. The degree of glass reactivity desired varies according to implantation situation and it is vital that the ion release from any glasses used in medical applications is controlled. Understanding the in vitro dissolution rate of glasses provides a first approximation of their behavior in vivo. Specific studies concerning dissolution properties of bioactive glasses have been relatively scarce and mostly concentrated to static condition studies. The motivation behind this work was to develop a simple and accurate method for quantifying the in vitro dissolution rate of highly different types of glass compositions with interest for future clinical applications. By combining information from various experimental conditions, a better knowledge of glass dissolution and the suitability of different glasses for different medical applications can be obtained. Thus, two traditional and one novel approach were utilized in this thesis to study glass dissolution. The chemical durability of silicate glasses was tested in water and TRIS-buffered solution at static and dynamic conditions. The traditional in vitro testing with a TRISbuffered solution under static conditions works well with bioactive or with readily dissolving glasses, and it is easy to follow the ion dissolution reactions. However, in the buffered solution no marked differences between the more durable glasses were observed. The hydrolytic resistance of the glasses was studied using the standard procedure ISO 719. The relative scale given by the standard failed to provide any relevant information when bioactive glasses were studied. However, the clear differences in the hydrolytic resistance values imply that the method could be used as a rapid test to get an overall idea of the biodegradability of glasses. The standard method combined with the ion concentration and pH measurements gives a better estimate of the hydrolytic resistance because of the high silicon amount released from a glass. A sensitive on-line analysis method utilizing inductively coupled plasma optical emission spectrometer and a flow-through micro-volume pH electrode was developed to study the initial dissolution of biocompatible glasses. This approach was found suitable for compositions within a large range of chemical durability. With this approach, the initial dissolution of all ions could be measured simultaneously and quantitatively, which gave a good overall idea of the initial dissolution rates for the individual ions and the dissolution mechanism. These types of results with glass dissolution were presented for the first time during the course of writing this thesis. Based on the initial dissolution patterns obtained with the novel approach using TRIS, the experimental glasses could be divided into four distinct categories. The initial dissolution patterns of glasses correlated well with the anticipated bioactivity. Moreover, the normalized surface-specific mass loss rates and the different in vivo models and the actual in vivo data correlated well. The results suggest that this type of approach can be used for prescreening the suitability of novel glass compositions for future clinical applications. Furthermore, the results shed light on the possible bioactivity of glasses. An additional goal in this thesis was to gain insight into the phase changes occurring during various heat treatments of glasses with three selected compositions. Engineering-type T-T-T curves for glasses 1-98 and 13-93 were stablished. The information gained is essential in manufacturing amorphous porous implants or for drawing of continuous fibers of the glasses. Although both glasses can be hot worked to amorphous products at carefully controlled conditions, 1-98 showed one magnitude greater nucleation and crystal growth rate than 13-93. Thus, 13-93 is better suited than 1-98 for working processes which require long residence times at high temperatures. It was also shown that amorphous and partially crystalline porous implants can be sintered from bioactive glass S53P4. Surface crystallization of S53P4, forming Na2O∙CaO∙2SiO2, was observed to start at 650°C. The secondary crystals of Na2Ca4(PO4)2SiO4, reported for the first time in this thesis, were detected at higher temperatures, from 850°C to 1000°C. The crystal phases formed affected the dissolution behavior of the implants in simulated body fluid. This study opens up new possibilities for using S53P4 to manufacture various structures, while tailoring their bioactivity by controlling the proportions of the different phases. The results obtained in this thesis give valuable additional information and tools to the state of the art for designing glasses with respect to future clinical applications. With the knowledge gained we can identify different dissolution patters and use this information to improve the tuning of glass compositions. In addition, the novel online analysis approach provides an excellent opportunity to further enhance our knowledge of glass behavior in simulated body conditions.