140 resultados para 3672


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The increasing of afluence demands the companies to be competitive and have a deep knowledge about the area wich they are participating. Through the search of management and produtive information, and the analisys of internal and external information, the company could identify strong and weak points , threats and oportunities, alowing the obtaince of competitive advantages. This research shows the result of a close search study about the usage of strategic planning and management technics, setting in evidence the necessity of micro and small furniture companies and furniture supply chain, represented in this case by sub-contract companies. Still looking to accentuate the importance that this study will represent to the setorial development, specially to the furniture companies wich have a big importance due to the report of small utilization of management technics in the sub-contract companies. Through analisys, it was possible to find out some common caracteristics in all 171 conmpanies evaluated, wich are showing likely 'sinalization', such as: - lower level os scholarship (96,5% elementary school, 3% until high school, 0,5% university/college graduration); - external market from Brazilian MPE¿s (5% export products to Mercosul and just 1% export products to Latin America, absenting exportations to other markets); - carefree with modern technics of management, certificates ISO 9000, 14000, MRP, CQT, among others; - carefree with strategic planning; - lower utilization of operacionl procedures, rules and function description; - ignoring the participating of market; - lower utilization of human resources index as a management form; - Small utilization of costs tabs (31%), with a small informatization level (8%) and apllying with non-management form; - low utilization of quality statistics (4%), re-working index (9%), among others. In syntesis, the basis expose that the great marjority of companies don¿t have knowledge about planning and the modern technics of management.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho objetivou avaliar o valor de resistência à penetração limitante à produtividade de arroz de sequeiro (Oryza sativa cv. IAC 165) no conteúdo de água retida, na tensão de 0,05 e 0,01 MPa. Foram utilizadas amostras de Latossolo Vermelho, textura média (LVd) e, Latossolo Vermelho, textura argilosa (LVef), coletadas na profundidade de 0,00-0,20m, passadas em peneira de 0,004m e compactados em camadas de 0,03m, em vasos de 0,20m de altura e 0,25m de diâmetro (0,00982m³). Os valores de resistência à penetração foram determinados com o penetrômetro de anel dinamométrico. Utilizou-se o delineamento inteiramente casualizado, em esquema fatorial 4 x 2, com três repetições. No conteúdo de água retida, na tensão de 0,01MPa, o valor de resistência do solo à penetração limitante à produtividade de grãos de arroz de sequeiro foi de 2,38 e 2,07MPa, respectivamente, para o LVd e LVef. No conteúdo de água retida na tensão de 0,05MPa foram obtidas maiores produções no menor valor de resistência à penetração. O arroz de sequeiro foi menos produtivo no conteúdo de água retida na tensão de 0,05MPa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The isotherms of adsorption of MeX2 (Me = Cu2+, Co2+; X = Cl-, Br-, ClO4-) by silica gel chemically modified with 2-mercaptoimidazole (SiMI) were studied in acetone and ethanol solutions, at 25 degrees C. Covalently attached 2-mercaptoimidazole molecule to silica gel surface adsorbs MeX2 from solvent by forming a surface complex. The metal is bonded to the surface through the nitrogen atom of attached 2-mercaptoimidazole. At low loading, the electronic and ESR spectral parameters indicated that the Cu2+ complexes are in a distorted-tetragonal symmetry field. The d-d electronic transition spectra showed that for Cu(ClO4)(2) complex, the peak of absorption did not change for any degree of metal loading and for Cl- and Br- complexes, the peak maxima shifted to higher energy with lower metal loading. The CoX2(X = Cl-, Br-, ClO4-) analogues possess a distorted-tetrahedral field.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the synthesis and characterization of 2-aminothiazole modified silica gel (SiAT) and the studies of adsorption and pre-concentration (in batch and using a flow-injection system coupled with optical emission spectrometer) of Cd(II), Cu(II) and Ni(II) in aqueous medium. The adsorption capacity for each metal ions in mmolg(-1) was: Cu(II) = 1.18, Ni(II) = 1.15 and Cd(II) = 1.10. The results obtained in the flow experiments showed about 100% of recovering of the metal ions adsorbed in a mini-column packed with 100 mg of SiAT, using 100 mu L of 2.0 mol L-1 HCl solution as eluent. The quantitative sorption-desorption of the metal ions made possible the application of a flow-injection system in the pre-concentration and quantification by ICP-OES of metal ions at trace level in natural water samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of Saccharomyces cerevisiae as a substrate to selectively retain Sn(II) and Sn(IV) has been investigated. Several factors affecting the retention of the analytes by yeast, such as pH, amount of biomass, temperature and time of contact were evaluated. Based on this study, a method for determination of Sn(II) and Sn(IV) combining inductively coupled plasma optical emission spectrometry (ICP OES) and solid phase extraction using Saccharomyces cerevisiae is proposed. The procedure consists of the selective retention of Sn(IV) by yeast at pH = 2.0 while Sn(II) remains in solution. Determination of tin in the solid phase was easily carried out by submitting a slurry of the yeast (0.5 g/40 mL) directly to ICP OES. The precision of the extraction procedure was characterized by an RSD lower than 4%. The detection limits of tin (3 sigma) in the solid phase and the liquid phase were 1.1 and 0.7 mu g L-1, respectively. The proposed approach was evaluated for determination of Sn(II) and Sn(IV) in spiked river water and real samples of industrial waste water (untreated and treated). For all samples, recoveries of spiked Sn(II) and Sn(IV) were between 85 and 112%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of Saccharomyces cerevisiae as a sorbent material to separate Cd(II) and Cd-metallothionein complex (Cd-MT) has been explored. Solid-liquid phase extractions were carried out in batch mode and the main parameters of the process (pH, temperature, time of incubation, amount of biomass and analyte) were evaluated. Under optimized conditions, the yeast quantitatively retain (94 +/- 5%) the Cd(II) while 97 +/- 2% of the Cd-MT remain in the supernatant. on base of the findings of this study, a simple method is proposed to determine Cd(II) and Cd-MT in cytosols extracted from mouse kidney and crab hepatopancreas. Inductively coupled plasma optical emission spectrometry was used to quantify the analytes in solid and liquid phase. Determination of Cd in the solid phase was carried out by introducing a slurry of the yeast (0.0625 g/10 mL) directly to the inductively coupled plasma optical emission spectrometer. Mixed standards solutions, which also have been submitted to the extraction procedure, were used to quantify the analytes in the samples. Thus, matrix effects due to nebulization of the slurry were overcame. Limits of detection (3 sigma) for Cd(II) and Cd-MT were 1.5 and 1.2 mu g L-1, respectively. Relative standard deviations of signals were 4.2% for measurements in the slurry of solid phase and 2.1% for measurements in the liquid phase. Recoveries of the analytes in cytosol samples were between 76 and 114%. The concentrations of Cd(II) (2.4 +/- 0.5 mu g L-1) and Cd-MT (3.0 +/- 0.5 mu g L-1) found by using the proposed approach were close to those found by tangential-flow ultrafiltration technique (2.6 +/- 0.7 mu g L-1 for Cd(II) and 3.7 +/- 1.7 mu g L-1 for Cd-MT).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A mercury-free electrode chemically modified with carbon paste containing dimethylglyoxime was used for determination of nickel in fuel ethanol. The instrumental parameters and composition of the modified paste were optimized. The analytical curve for nickel determination from 5.0 x 10(-9) to 5.0 x10(-7) mol(-1) was obtained using 25 min of accumulation time. The detection limit and amperometric sensitivity obtained for this method were 2.7 x 10 mol(-1) and 5.2 x 10(8) mu A mol(-1) L, respectively. The values for nickel concentration in four commercial samples of fuel ethanol were obtained in the range of 1.1 x 10(-8) to 6.9 x 10(-8) mol(-1). A comparison to graphite furnace atomic absorption spectrometry (GFAAS) was performed for nickel determination in commercial samples of ethanol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Different kinds of modifiers and coatings on the integrated platform of transversely heated graphite atomizer (THGA) have been tested for the simultaneous determination of two group of elements: the first, the more volatile, formed by arsenic, bismuth, lead, antimony and selenium; the second, the less volatile, formed by cobalt, chromium, cupper, iron and manganese in milk by electrothermal atomic absorption spectrometry. Different Rh-modifiers were studied, such as Rh-coated platforms (Rh), carbide plus rhodium coated platforms (W-Rh, Zr-Rh), carbide-coated platforms (W and Zr) with co-injection of RhCl3, solutions and uncoated platforms with injection of solutions of Pd(NO3)(2), Mg(NO3)(2), and RhCl3. Milk samples were diluted 1:10 in 1.0% HNO3 and injected into the tube. The mass of modifier deposited and co-injected in the tube and the use of end capped tubes were also evaluated in order to improve the electrothermal behavior of analytes. Integrated platform pretreated with W plus co-injection RhCl3 for first group and pretreated with W-Rh for second group were elected. For 20 mu L injected samples the analytical curves in the 5.0-20.0 mu g L-1 concentration range have good linear correlation coefficients (r > 0.998). Relative standard deviations (n = 12) are < 6% and the calculated characteristic masses are between 5 pg and 62 pg.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The chemically modified silica, obtained by reacting 2-mercaptobenz-imidazole with 3-chloropropyl silica gel, was used to adsorb Cu(II), Zn(II), Cd(II) and Pb(II) from aqueous solutions at various pH. Between pH 3-5, the order of selectivity was Hg(II) > Cd(II) ≫ Cu(II) ∼ Zn(II) ∼ Pb(II). Under batch conditions retentions of 100% were achieved for all metals except for Pb(II) where 93% was attained. Under column conditions recoveries of 100% were obtained for all metals. © 1990 Springer-Verlag.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A potentiometric sensor for the perchlorate anion was developed by mixing chemically modified silicagel with pyridinium perchlorate, with an epoxy polymer and graphite. The electrode showed Nernstian response between 1.0 × 10-2 and 1.0 × 10-3M perchlorate concentrations. The electrode showed high selectivity to this ion at solutions pH between 5.5 and 8.0. The presence of IO4 -, NO3 -,Br-, IO3 -, Cl- and SO4 2- ions in the solutions, had only small interference in the electrode response in the range mentioned. © 1995 Springer-Verlag.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Incluye Bibliografía

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: avaliar as alterações de cor ocorridas em elastômeros estéticos de quatro marcas comerciais, quando expostos ao meio bucal. MÉTODOS: foram examinadas as quatro marcas comerciais mais citadas por ortodontistas — Morelli, Uniden, American Orthodontics (AO) e TP —, em 25 pacientes consecutivos. Os elastômeros foram distribuídos de forma aleatória e ordenados nas quatro hemiarcadas de cada paciente, permanecendo no meio bucal por 30 dias. Após esse período, duas unidades de cada marca em todos os pacientes foram fotografadas de forma padronizada para, posteriormente, serem analisadas através de avaliação visual quanto à variação de cor, por escores (0, 1, 2, 3), por um painel de quatro examinadores. Os escores médios dos examinadores foram analisados estatisticamente por meio da ANOVA e teste de Tukey, com p<0,05. RESULTADOS: os escores médios de pigmentação, após 30 dias no meio intrabucal, obtidos para os elastômeros Morelli (1,80±0,78) e Uniden (1,92±0,66) não foram estatisticamente diferentes entre si. Entretanto, essas marcas estavam significativamente mais pigmentadas após 30 dias no meio intrabucal (p<0,01) quando comparadas às marcas importadas, American Orthodontics (0,97±0,6) e TP (0,83±0,79). CONCLUSÃO: apesar de todas as quatro marcas apresentarem uma indesejável pigmentação após 30 dias no meio intrabucal, as marcas American Orthodontics e TP apresentaram alterações de cor menos significativas do que as marcas Morelli e Uniden.