954 resultados para scintillation detectors
Resumo:
We describe an experimental system designed for single-shot photoelectron spectroscopy on free atoms and molecules at the Free Electron Laser in Hamburg (FLASH at DESY). The combination of the extreme ultra-violet (EUV) Free Electron Laser and a temporally synchronized optical fs laser (Ti:Sapphire) enables a variety of two-color pump-probe experiments. The spectral, temporal and spatial characteristics of both the EUV FEL and the optical laser pulses, the experimental procedure to control their overlap as well as the performance of an electron spectrometer used to obtain single-shot photoelectron spectra are discussed. As an illustration of the capabilities of this set-up, some results on two-photon two-color ionization of rare gases are presented. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
The generation of an entangled coherent state is one of the most important ingredients of quantum information processing using coherent states. Recently, numerous schemes to achieve this task have been proposed. In order to generate travelling-wave entangled coherent states, cross-phase-modulation, optimized by optical Kerr effect enhancement in a dense medium in an electromagnetically induced transparency (EIT) regime, seems to be very promising. In this scenario, we propose a fully quantized model of a double-EIT scheme recently proposed [D. Petrosyan and G. Kurizki, Phys. Rev. A 65, 33 833 (2002)]: the quantization step is performed adopting a fully Hamiltonian approach. This allows us to write effective equations of motion for two interacting quantum fields of light that show how the dynamics of one field depends on the photon-number operator of the other. The preparation of a Schrodinger cat state, which is a superposition of two distinct coherent states, is briefly exposed. This is based on nonlinear interaction via double EIT of two light fields (initially prepared in coherent states) and on a detection step performed using a 50:50 beam splitter and two photodetectors. In order to show the entanglement of an entangled coherent state, we suggest to measure the joint quadrature variance of the field. We show that the entangled coherent states satisfy the sufficient condition for entanglement based on quadrature variance measurement. We also show how robust our scheme is against a low detection efficiency of homodyne detectors.
Resumo:
MALDI (matrix-assisted laser desorption/ionization) is one of the most important techniques used to produce large biomolecular ions in the gas phase. Surprisingly, the exact ionization mechanism is still not well understood and absolute values for the ion yields are scarce. This is in part due to the unknown efficiencies of typical detectors, especially for heavy biomolecular ions. As an alternative, charged particles can be non-destructively detected using an image-charge detector where the output voltage signal is proportional to the total charge within the device. In this paper, we report an absolute calibration which provides the voltage output per detected electronic charge in our experimental arrangement. A minimum of 3 x 10(3) ions were required to distinguish the signal above background noise in a single pass through the device, which could be further reduced using filtering techniques. The calibration results have been applied to raw MALDI spectra to measure absolute ion yields of both matrix and analyte ions.
A new algorithm for spectral and spatial reconstruction of proton beams from dosimetric measurements
Resumo:
We report on a new algorithm developed for the dosimetric analysis of broad-spectrum, multi-MeV laser-accelerated proton beams. The algorithm allows the reconstruction of the proton beam spectrum from radiochromic film data. This processing technique makes dosimetry measurements a viable alternative to the use of track detectors for spatially and spectrally resolved proton beam analysis. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
We consider an electrostatic qubit located near a Bose-Einstein condensate (BEC) of noninteracting bosons in a double-well potential, which is used for qubit measurements. Tracing out the BEC variables we obtain a simple analytical expression for the qubit's density matrix. The qubit's evolution exhibits a slow (proportional to 1/root t) damping of the qubit's coherence term, which however turns to be a Gaussian one in the case of static qubit. This is in contrast to the exponential damping produced by most classical detectors. The decoherence is, in general, incomplete and strongly depends on the initial state of the qubit.
Resumo:
A novel method of obtaining high-quality Raman spectra of luminescent samples was tested using cyclohexane solutions which had been treated with a fluorescent dye. The method involves removing the fixed pattern irregularity found in the spectra taken with CCD detectors by subtracting spectra taken at several different, closely spaced spectrometer positions. It is conceptually similar to SERDS (shifted excitation Raman difference spectroscopy) but has the distinct experimental advantage that it does not require a tunable laser source. The subtracted spectra obtained as the raw data are converted into a more recognisable and conventional form by iterative fitting of appropriate double Lorentzian functions whose peak parameters are then used to 'reconstruct' a conventional representation of the spectrum. Importantly, it is shown that the degree of uncertainty in the resultant 'reconstructed' spectra can be gauged reliably by comparing reconstructed spectra obtained at two different spectrometer shifts (delta and 2 delta), The method was illustrated and validated using a solvent (cyclohexane) the spectrum of which is well known and which contains both regions with complex overlapping bands and regions with isolated bands, Possible sources of error are discussed and it is shown that, provided the degree of uncertainty in the data is correctly characterised, it is completely valid to draw conclusions about the spectra of the sample on the basis of the reconstructed data. The acronym SSRS (subtracted shifted Raman spectroscopy; pronounced scissors) is proposed for this method, to distinguish it from the SERDS technique.
The effect of triclabendazole ("Fasinex") on protein synthesis by the liver fluke, Fasciola hepatica
Resumo:
The effect of the active sulphoxide metabolite of the anthelmintic triclabendazole (TCBZ-SX, 15-50 mu g ml(-1)) on the incorporation of radioactively labelled [C-14] leucine by adult Fasciola hepatica tissue slices was measured by liquid scintillation counting. In addition, the ability of the microfilament-disrupting drug, cytochalasin B, and the microtubule-disrupting drug, tubulozole-C, to inhibit protein synthesis, was assessed by similar methods and compared with TCBZ-SX. The established protein synthesis inhibitors, cycloheximide and actinomycin D were used as positive controls. All the drugs showed a significant inhibition of protein synthesis, albeit to different extents; however, TCBZ-SX was the most potent, with no significant difference between its effect and that of cycloheximide or actinomycin D. Moreover, the concentration of TCBZ-SX, above 15 mu g ml(-1), had little further influence on incorporation of [C-14] leucine. This investigation demonstrates the inhibitory effect of TCBZ-SX, cytochalasin B and tubulozole-C on protein synthesis in F. hepatica and confirms the qualitative observations made in several previous ultrastructural studies.
Resumo:
The effect of the deacetylated (amine) metabolite of diamphenethide (DAMD, 10 mug ml-1) on the uptake and incorporation by adult Fasciola hepatica of radioactively labelled precursors of DNA, RNA and protein synthesis ([H-3]thymidine, [H-3]uridine and [H-3]leucine, respectively) was measured by liquid scintillation counting. Comparison was made between the effects of DAMD and those of specific inhibitors of DNA, RNA and protein synthesis, namely, 5-fluorouracil, cordycepin and cycloheximide, respectively. DAMD caused a significant decrease in the overall uptake and incorporation of [H-3]uridine by F. hepatica, decreased the incorporation of [H-3]leucine and also caused a significant decrease in the overall protein content of the flukes. The effect of DAMD was similar to that of cycloheximide (I x 10(-3) M), a potent inhibitor of protein synthesis, which also caused a significant decrease in the incorporation of [H-3]leucine by the fluke and a decrease in the overall protein content of the fluke. Cordycepin(100 mug ml-1) caused a significant decrease in the protein content of the fluke, but had no effect on the uptake or incorporation of [H-3]uridine. 5-Fluorouracil (I x 10(-4) m) did not affect the uptake or incorporation of VH]thymidine, nor did it decrease the protein content of the fluke. The results indicate that DAMD inhibits protein synthesis by F. hepatica, possibly by inhibiting RNA synthesis. The results are also consistent with previous morphological investigations involving DAMD.
Resumo:
The propagation of a 1-ps laser pulse at intensities exceeding 10(19) Wcm(-2) in a low-density plasma channel was experimentally tested. The channel was produced by a lower intensity preceding pulse of the same duration. Plasma electrons were accelerated during the propagation of the main pulse, and high energy gamma -ray detectors were used to detect their bremsstrahlung emission. The gamma -ray yield was studied for different channel conditions, by varying the delay between the channel forming pulse and the high intensity pulse. These results are correlated with the interferograms of the propagation region into the plasma.
Resumo:
Proton imaging has become a common diagnostic technique for use in laser-plasma research experiments due to their ability to diagnose electric field effects and to resolve small density differences caused through shock effects. These interactions are highly dependent on the use of radiochromic film (RCF) as a detection system for the particle probe, and produces very high-resolution images. However, saturation effects, and in many cases, damage to the film limits the usefulness of this technique for high-flux particle probing. This paper outlines the use of a new technique using contact radiography of (p,n)-generated isotopes in activation samples to produce high dynamic range 2D images with high spatial resolution and extremely high dynamic range, whilst maintaining both energy resolution and absolute flux measurements. (C)007 Elsevier B.V. All rights reserved.
Resumo:
As a diagnostic of high-intensity laser interactions (> 10(19) W cm(-2)), the detection of radioactive isotopes is regularly used for the characterization of proton, neutron, ion, and photon beams. This involves sample removal from the interaction chamber and time consuming post shot analysis using NaI coincidence counting or Ge detectors. This letter describes the use of in situ detectors to measure laser-driven (p,n) reactions in Al-27 as an almost real-time diagnostic for proton acceleration. The produced Si-27 isotope decays with a 4.16 s half-life by the predominantly beta+ emission, producing a strong 511 keV annihilation peak. (c) 2006 American Institute of Physics.
Resumo:
The application of high intensity laser-produced gamma rays is discussed with regard to picosecond resolution deep-penetration radiography. The spectrum and angular distribution of these gamma rays is measured using an array of thermoluminescent detectors for both an underdense (gas) target and an overdense (solid) target. It is found that the use of an underdense target in a laser plasma accelerator configuration produces a much more intense and directional source. The peak dose is also increased significantly. Radiography is demonstrated in these experiments and the source size is also estimated. (C) 2002 American Institute of Physics.
Resumo:
A simple Langmuir probe technique has been used to measure the electron density, electron temperature, and plasma potential in the late stages (>5 mu s) of a laser ablated plasma plume. In the plasma, formed following 248 nm laser irradiation of a copper target, in vacuum at a laser fluence of 2.5 J cm(-2), electron densities of similar to 10(18) m(-3) and temperatures of similar to 0.5 eV were measured. These values are comparable with those reported previously using Faraday cup detectors and optical emission spectroscopy, respectively. (C) 1997 American Institute of Physics.
Resumo:
It has been suggested that the symptoms of flatulent dyspepsia are caused by a functional disturbance of the upper gastrointestinal tract. The aim of this study was to investigate delayed gastric emptying as the basis of symptoms in patients with and without gallbladder disease and after cholecystectomy. There were 13 dyspeptic patients with gallbladder disease, 12 with normal gallbladders, and 13 post-cholecystectomy patients. Gastric emptying was measured by means of a 99mTc-labelled scrambled egg meal and external scintillation counter. The rate of emptying in the symptomatic groups was compared with that in 24 asymptomatic normal control subjects and 12 non-dyspeptic patients with gallbladder disease. Delayed gastric emptying tended to occur in patients with gallbladder disease with and without dyspepsia and was not specifically associated with symptoms.