982 resultados para Veia central da supra-renal
Resumo:
OBJETIVO: Validar métodos de estimativas da gordura corporal (somatória de espessura de dobras cutâneas, circunferência da cintura (CC) e razão cintura-quadril (RCQ)) em portadores do HIV/Aids, tendo como padrão ouro a absortometria por dupla emissão de raios-X (Dexa) e a tomografia computadorizada de abdômen (TCA). MÉTODOS: Foram estudados 15 portadores do HIV/Aids tratados em uma unidade de saúde coligada a um hospital público universitário, São Paulo. Foram medidas a gordura subcutânea total (GST) mediante a somatória da espessura de sete dobras (bíceps, tríceps, subescapular, axilar média, supra-ilíaca, abdominal e panturrilha medial), a gordura subcutânea central (GSC) (somatória da espessura de quatro dobras) e a gordura subcutânea de membros (GSM) (somatória da espessura de três dobras). A GST, GSC e GSM foram comparadas com as medidas de gordura obtidas pela Dexa. A CC, a RCQ e a GSC foram comparadas com as medidas de gordura obtidas pela TCA. Na análise estatística, utilizou-se o coeficiente de correlação de Pearson (r) e foi utilizado o teste de Mann-Whitney. RESULTADOS: A gordura medida pela Dexa foi correlacionada com GST, a GSC e GSM, mesmo após o ajuste pela idade (r>0,80 para todos). A gordura total de abdômen medida pela TCA foi correlacionada com a CC, RCQ e a GSC após o ajuste pela idade (r>0,80 para todos). CONCLUSÕES: Os métodos de estimativa da gordura corporal devem ser escolhidos de acordo com o tipo de gordura a ser avaliada e podem ser utilizados em pesquisas e nos serviços de saúde como alternativa à Dexa e TCA para portadores do HIV/Aids.
Resumo:
A marcha é influenciada por um conjunto de factores que resultam da interacção e organização própria de sistemas neurais e mecânicos, entre os quais, da dinâmica músculo-esquelética, da modulação pelos centros nervosos superiores, pela modulação aferente e é, também, assumida como sendo controlada pelo Gerador de Padrão Central (GPC), que se define como um programa central baseado num circuito espinal geneticamente determinado, capaz de produzir um ritmo associado a cada marcha. Apresenta-se como objectivo deste trabalho abordar quais os modelos explicativos para o funcionamento do GPC e qual a evidência científica, que continua a ter muitas divergências.
Resumo:
Development of Dual Source Computed Tomography (Definition, Siemens Medical Solutions, Erlanger, Germany) allowed advances in temporal resolution, with the addition of a second X-ray source and an array of detectors to the TCM 64 slices. The ability to run exams on Dual Energy, allows greater differentiation of tissues, showing differences between closer attenuation coefficients. In terms of renal applications, the distinction of kidney stones and masses become one of the main advantages of the use of dual-energy technology. This article pretends to demonstrate operating principles of this equipment, as its main renal applications.
Resumo:
Introdução: No Centro Hospitalar de São João, EPE a partir de 2008, foi implementado o sistema semi-automático de reposição de stocks nivelados de medicamentos, Pyxis®, atualmente implementado em 16 serviços clínicos. Atendendo ao crescimento verificado na implementação deste sistema automatizado na instituição, este trabalho pretende dar a conhecer a realidade de preparação da medicação para reposição no sistema semi-automático Pyxis®, por avaliação do número de unidades de medicamentos repostos diariamente e por dia da semana. Material e Métodos: Desenvolveu-se um estudo longitudinal retrospetivo onde se analisou a totalidade de serviços com implementação Pyxis® através do registo diário de reposição dos diferentes Serviços Clínicos num período de 41 dias consecutivos. Numa segunda fase, os dados foram sintetizados sob a forma de tabelas em Microsoft Office Excel®, tendo posteriormente sido construídos os respetivos gráficos para análise. Resultados: Os resultados, representados graficamente, mostram que a segunda-feira é o dia da semana com maior número de reposições de medicamentos, sendo os serviços com maior número de reposições totais UCI Geral, UCI Neurocríticos, Cirurgia Cardiotorácica e UCIPU. Discussão / Conclusões: Os resultados obtidos permitiram verificar uma sobrecarga de referências de medicamentos e unidades repostas às segundas-feiras, atingindo, em muitos serviços, valores de unidades repostas duas vezes superior à média de reposições do serviço (por ex. UCI Neurocíticos). Contudo, apesar do reduzido período de análise, os dados parecem evidenciar que o facto de haver reposições ao domingo agiliza o processo de reposição dos Pyxis® às segundas-feiras.
Resumo:
Renal scintigraphy with 99mTc-dimercaptosuccinic acid (99mTc-DMSA) is performed with the aim of detect cortical abnormalities related to urinary tract infection and accurately quantify relative renal function (RRF). For this quantitative assessment Nuclear Medicine Technologist should draw regions of interest (ROI) around each kidney (KROI) and peri-renal background (BKG) ROI although controversy still exists about BKG-ROI. The aim of this work was to evaluate the effect of the normalization procedure, number and location of BKG-ROI on the RRF in 99mTc-DMSA scintigraphy.
Resumo:
OBJECTIVE: To identify potential prognostic factors for neonatal mortality among newborns referred to intensive care units. METHODS: A live-birth cohort study was carried out in Goiânia, Central Brazil, from November 1999 to October 2000. Linked birth and infant death certificates were used to ascertain the cohort of live born infants. An additional active surveillance system of neonatal-based mortality was implemented. Exposure variables were collected from birth and death certificates. The outcome was survivors (n=713) and deaths (n=162) in all intensive care units in the study period. Cox's proportional hazards model was applied and a Receiver Operating Characteristic curve was used to compare the performance of statistically significant variables in the multivariable model. Adjusted mortality rates by birth weight and 5-min Apgar score were calculated for each intensive care unit. RESULTS: Low birth weight and 5-min Apgar score remained independently associated to death. Birth weight equal to 2,500g had 0.71 accuracy (95% CI: 0.65-0.77) for predicting neonatal death (sensitivity =72.2%). A wide variation in the mortality rates was found among intensive care units (9.5-48.1%) and two of them remained with significant high mortality rates even after adjusting for birth weight and 5-min Apgar score. CONCLUSIONS: This study corroborates birth weight as a sensitive screening variable in surveillance programs for neonatal death and also to target intensive care units with high mortality rates for implementing preventive actions and interventions during the delivery period.
Resumo:
Mestrado em Controlo e Gestão dos Negócios
Resumo:
A marcha é influenciada por um conjunto de factores que resultam da interacção e organização própria de sistemas neurais e mecânicos, entre os quais, da dinâmica músculo-esquelética, da modulação pelos centros nervosos superiores, pela modulação aferente e é, também, assumida como sendo controlada pelo Gerador de Padrão Central (GPC), que se define como um programa central baseado num circuito espinal geneticamente determinado, capaz de produzir um ritmo associado a cada marcha. Apresenta-se como objectivo deste trabalho abordar quais os modelos explicativos para o funcionamento do GPC e qual a evidência científica, que continua a ter muitas divergências.
Resumo:
OBJECTIVE: To assess the association between dietary intake and central obesity among people living with HIV/AIDS and receiving highly active antiretroviral therapy. METHODS: A cross-sectional study was conducted involving 223 adult individuals in the city of São Paulo city in 2002. The study population was classified according to central obesity, defined as waist-to-hip ratio >0.95 for men and >0.85 for women. The dietary variables studied were energy consumption (in calories and calories/kilo of body weight), macronutrients (in grams and % of energy intake), total fiber (grams) and fruit and vegetables intake (grams). The potential confounders examined were sex, skin color, age, schooling, income, body mass index, physical activity, smoking habits, peripheral CD4+ T lymphocyte count and length of protease inhibitor use. The multiple logistic regression model was performed in order to evaluate the association between central obesity and dietary intake. RESULTS: The prevalence of central obesity was 45.7% and it was associated with greater consumption of lipids: for every increase of 10g of lipid intake the odds of central obesity increased 1.28 times. Carbohydrate consumption showed negative association (OR=0.93) with central obesity after adjustment for control variables. CONCLUSIONS: The results suggest that the amount of carbohydrates and lipids in the diet, regardless of total energy intake, may modify the chance of developing central obesity in the studied population. Nutritional interventions may be beneficial for preventing central obesity among HIV/AIDS patients.
Resumo:
Throughout the world, epidemiological studies were established to examine the relationship between air pollution and mortality rates and adverse respiratory health effects. However, despite the years of discussion the correlation between adverse health effects and atmospheric pollution remains controversial, partly because these studies are frequently restricted to small and well-monitored areas. Monitoring air pollution is complex due to the large spatial and temporal variations of pollution phenomena, the high costs of recording instruments, and the low sampling density of a purely instrumental approach. Therefore, together with the traditional instrumental monitoring, bioindication techniques allow for the mapping of pollution effects over wide areas with a high sampling density. In this study, instrumental and biomonitoring techniques were integrated to support an epidemiological study that will be developed in an industrial area located in Gijon in the coastal of central Asturias, Spain. Three main objectives were proposed to (i) analyze temporal patterns of PM10 concentrations in order to apportion emissions sources, (ii) investigate spatial patterns of lichen conductivity to identify the impact of the studied industrial area in air quality, and (iii) establish relationships amongst lichen conductivity with some site-specific characteristics. Samples of the epiphytic lichen Parmelia sulcata were transplanted in a grid of 18 by 20 km with an industrial area in the center. Lichens were exposed for a 5-mo period starting in April 2010. After exposure, lichen samples were soaked in 18-MΩ water aimed at determination of water electrical conductivity and, consequently, lichen vitality and cell damage. A marked decreasing gradient of lichens conductivity relative to distance from the emitting sources was observed. Transplants from a sampling site proximal to the industrial area reached values 10-fold higher than levels far from it. This finding showed that lichens reacted physiologically in the polluted industrial area as evidenced by increased conductivity correlated to contamination level. The integration of temporal PM10 measurements and analysis of wind direction corroborated the importance of this industrialized region for air quality measurements and identified the relevance of traffic for the urban area.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
O trabalho de avaliação de projecto de investimento que apresentamos é constituído por duas peças de análise: - O presente relatório, onde é feito um enquadramento do projecto e do mercado onde ele se insere, onde são descritos os pressupostos assumidos na avaliação, as metodologias de avaliação seguidas e a análise dos resultados a que a avaliação conduz. - Uma folha de calculo, fornecida em formato digital (“CTBF_Modelo Avaliacao_Caso Base_v02.xls”), onde se desenvolve o Modelo de Avaliação Económico, designado de “Caso Base”, e onde se procedeu ao calculo dos vários indicadores da avaliação, sendo possível simular os efeitos de alterações nos vários inputs do modelo. Toda a análise é desenvolvida a preços correntes e os valores apresentados estão em todos os casos líquidos de IVA.
Produção de bioetanol a partir de um resíduo orgânico proveniente da central de compostagem da LIPOR
Resumo:
Mestrado em Engenharia Química
Resumo:
Dissertação de Mestrado em Engenharia e Gestão de Sistemas de Água.
Resumo:
Neste trabalho estuda-se a geração de trajectórias em tempo real de um robô quadrúpede. As trajectórias podem dividir-se em duas componentes: rítmica e discreta. A componente rítmica das trajectórias é modelada por uma rede de oito osciladores acoplados, com simetria 4 2 Z Z . Cada oscilador é modelado matematicamente por um sistema de Equações Diferenciais Ordinárias. A referida rede foi proposta por Golubitsky, Stewart, Buono e Collins (1999, 2000), para gerar os passos locomotores de animais quadrúpedes. O trabalho constitui a primeira aplicação desta rede à geração de trajectórias de robôs quadrúpedes. A derivação deste modelo baseia-se na biologia, onde se crê que Geradores Centrais de Padrões de locomoção (CPGs), constituídos por redes neuronais, geram os ritmos associados aos passos locomotores dos animais. O modelo proposto gera soluções periódicas identificadas com os padrões locomotores quadrúpedes, como o andar, o saltar, o galopar, entre outros. A componente discreta das trajectórias dos robôs usa-se para ajustar a parte rítmica das trajectórias. Este tipo de abordagem é útil no controlo da locomoção em terrenos irregulares, em locomoção guiada (por exemplo, mover as pernas enquanto desempenha tarefas discretas para colocar as pernas em localizações específicas) e em percussão. Simulou-se numericamente o modelo de CPG usando o oscilador de Hopf para modelar a parte rítmica do movimento e um modelo inspirado no modelo VITE para modelar a parte discreta do movimento. Variou-se o parâmetro g e mediram-se a amplitude e a frequência das soluções periódicas identificadas com o passo locomotor quadrúpede Trot, para variação deste parâmetro. A parte discreta foi inserida na parte rítmica de duas formas distintas: (a) como um offset, (b) somada às equações que geram a parte rítmica. Os resultados obtidos para o caso (a), revelam que a amplitude e a frequência se mantêm constantes em função de g. Os resultados obtidos para o caso (b) revelam que a amplitude e a frequência aumentam até um determinado valor de g e depois diminuem à medida que o g aumenta, numa curva quase sinusoidal. A variação da amplitude das soluções periódicas traduz-se numa variação directamente proporcional na extensão do movimento do robô. A velocidade da locomoção do robô varia com a frequência das soluções periódicas, que são identificadas com passos locomotores quadrúpedes.