892 resultados para HVDC Multilevel Converters
When culture does (not) matter: role models and self-efficacy as drivers of entrepreneurial behavior
Resumo:
The correlation between facets of national culture and startup activities has received confirmation in empirical research while many mechanisms behind the correlation remain unclear. We study the interplay between the individualism-collectivism orientation of national culture, the incidence of entrepreneurial role models and selfefficacy understood as the perception of possessing relevant skills and knowledge to become a successful entrepreneur. We find that exposure to entrepreneurial role models offsets self-efficacy as a driver of entrepreneurial intentions. The effect is magnified by the individualistic character of the national culture. Key words: entrepreneurial intentions, role models, self-efficacy, individualism, multilevel regressions
Resumo:
Tässä työssä tarkastellaan taajuusmuuttajan vanhenemista syklisissä käytöissä puolijohdetehokomponenttien osalta. Laitteiden vikaantumisprosessien analysoimiseksi työssä suunnitellaan syklinen kestotestausjärjestelmä, joka mahdollistaa useamman taajuusmuuttajan yhtäaikaisen vanhentamisen. Jaksottaisesti toistuvat kuormitussyklit rasittavat termomekaanisesti taajuusmuuttajan tehomoduulin sisäisiä rakenteita suurten lämpötilavaihtelujen johdosta. Teoriaosuuden pääpaino kohdistuu puolijohdetehokomponenttien rakenteeseen, vikaantumisprosesseihin ja eliniän kartoittamiseen. Työssä käydään läpi yleisimpien pienijännitteisten moottorinohjausinverttereiden tehomoduulien mekaaniset rakenteet, tyypillisemmät syklisestä kuormituksesta johtuvat vikaantumisprosessit sekä puolijohdetehokomponenttivalmistajien käyttämät syklisen eliniän testausmenetelmät. Loppuosassa työtä suunnitellaan taajuusmuuttajan syklinen kestotestausjärjestelmä laitteiden keinotekoista vanhentamista varten. Testausjärjestelmällä voidaan kuormittaa useampaa taajuusmuuttajaa vuorottain mielivaltaisella kuormitusvirtaprofiililla. Laitteita vanhennettiin kaksi testierää kuormittamalla niitä jaksottaisesti hissikäytön tyypillisellä kuormitusprofiililla. Puolijohdetehokomponentin vanhenemisen edistystä seurattiin termisen impedanssiketjun mittausmenetelmällä, joka perustuu IGBT:n kollektoriemitterijännitteen lämpötilariippuvuuteen. Testilaitteiden puolijohdetehokomponentit hajosivat syklisen eliniän päättymiseen teoriassa esitettyjen vikaantumisprosessien seurauksesta. Tehomoduulien vika-analyysi osoittaa syklisen kestotestausjärjestelmän soveltuvaksi menetelmäksi tutkia erilaisten kuormitusprofiilien vaikutusta taajuusmuuttajan vanhenemiseen.
Resumo:
This Master's thesis deals with a Micro Scale Wind Wind Turbine application. The thesis consists of nine chapters. The first chapter is an introduction to the philosophy of a small scale wind turbine application. The second defines concepts, and lists the requirements. The third presents the whole application for an On-Grid , and for an Off-Grid arrangement, with main concentration on lighting, heating, and energy storage. The fourth deals with the Inverter's technology, which are used for the conversion of the produced power. The fifth chapter presents the available storage technology and it's possibilities. The sixth deals with the system, and the technological means used for the implementation. The seventh presents the PLC device, which was used as the controller for the management of the whole application. The eighth deals with the concept and the control application philosophy that the PLC involves. And the final chapter presents conclusions and ideas for further considerations.
Resumo:
Technical analysis of Low Voltage Direct Current (LVDC) distribution systems shows that in LVDC transmission the customer voltage quality is higher. One of the problems in LVDC distribution networks that converters both ends of the DC line are required. Because of the converters produce not pure DC voltage, but some fluctuations as well, the huge electrolytic capacitors are required to reduce voltage distortions in the DC-side. This thesis master’s thesis is focused on calculating required DC-link capacitance for LVDC transmission and estimation of the influence of different parameters on the voltage quality. The goal is to investigate the methods of the DC-link capacitance estimation and location in the transmission line.
Resumo:
The exhaust emissions of vehicles greatly contribute to environmental pollution. Diesel engines are extremely fuel-efficient. However, the exhaust compounds emitted by diesel engines are both a health hazard and a nuisance to the public. This paper gives an overview of the emission control of particulates from diesel exhaust compounds. The worldwide emission standards are summarized. Possible devices for reducing diesel pollutants are discussed. It is clear that after-treatment devices are necessary. Catalytic converters that collect particulates from diesel exhaust and promote the catalytic burn-off are examined. Finally, recent trends in diesel particulate emission control by novel catalysts are presented.
Resumo:
In the context of autonomous sensors powered by small-size photovoltaic (PV) panels, this work analyses how the efficiency of DC/DC-converter-based power processing circuits can be improved by an appropriate selection of the inductor current that transfers the energy from the PV panel to a storage unit. Each component of power losses (fixed, conduction and switching losses) involved in the DC/DC converter specifically depends on the average inductor current so that there is an optimal value of this current that causes minimal losses and, hence, maximum efficiency. Such an idea has been tested experimentally using two commercial DC/DC converters whose average inductor current is adjustable. Experimental results show that the efficiency can be improved up to 12% by selecting an optimal value of that current, which is around 300-350 mA for such DC/DC converters.
Resumo:
Työyhteisön sosiaalinen pääoma ja työntekijöiden terveys Monien tutkimusten mukaan sosiaalinen pääoma vaikuttaa terveyteen. Vaikka työssä käyvä väestönosa on merkittävän osan valveillaoloajastaan työyhteisössä, siellä kertyvää sosiaalista pääomaa on toistaiseksi tutkittu vähän. Tässä tutkimuksessa selvitettiin työyhteisön sosiaalisen pääoman ja kuntatyöntekijöiden terveyden välistä yhteyttä pitkittäisasetelmassa hyödyntäen Kuntasektorin henkilöstön seurantatutkimuksen aineistoa vuosilta 2000–2005. Yhteensä 48592 kuntatyöntekijää vastasi kyselyyn vuosina 2000–02 (vastausprosentti 68 %). Heistä 35914 (77 %) osallistui myös seurantatutkimukseen vuosina 2004–05. Tutkimuksessa kehitettiin kyselyyn perustuva työyhteisön sosiaalisen pääoman mittausmenetelmä. Työntekijän omaan arvioon perustuvan sosiaalisen pääoman lisäksi mitattiin työyhteisön sosiaalista pääomaa käyttämällä samassa työyhteisössä työskentelevien muiden työntekijöiden keskimääräistä arviota sosiaalisesta pääomasta. Terveyttä mitattiin kysymyksellä koetusta terveydestä. Masennusta arvioitiin sekä kysymällä lääkärin toteamasta masennuksesta että masennuslääkeostoilla Kelan lääkerekistereistä. Analyyseihin otettiin mukaan vain ne kuntatyöntekijät, jotka olivat lähtötilanteissa terveitä eli kokivat terveytensä hyväksi tai heillä ei ollut aiempaa diagnosoitua tai lääkehoitoa vaatinutta masennusta. Tulosten analysointiin käytettiin monitasomallinnusta. Tulokset vakioitiin sosiodemografisten tekijöiden ja terveyskäyttäytymisen suhteen. Neljän vuoden seurannassa sekä jatkuvasti vähäinen että vähenevä yksilön sosiaalinen pääoma työssä lisäsi riskiä koetun terveyden heikkenemiseen niillä kuntatyöntekijöillä, jotka eivät vaihtaneet työpaikkaa seurannan aikana ja jotka seurannan alussa kokivat terveytensä hyväksi. Tulos ei selittynyt sosiodemografisilla tekijöillä tai terveyskäyttäytymisen eroilla. Tuloksen merkittävyyttä tuki havainto, että myös työtoverien arvioon perustuva sosiaalinen pääoma ennusti oman terveyden huononemista seuranta-aikana. Niillä työntekijöillä, jotka työskentelivät sellaisissa työyhteisöissä, joissa koko seurannan ajan oli vähiten sosiaalista pääomaa, oli lähes 1.3 -kertainen riski terveyden heikentymiseen. Vähäinen omaan arvioon perustuva sosiaalinen pääoma työssä ennusti myös masennuksen ilmaantuvuutta lähtötilanteessa ei-masentuneilla lähes neljän vuoden seurannassa. Matalaan sosiaaliseen pääomaan liittyi 20–50 % suurempi todennäköisyys sairastua masennukseen seurannan aikana niin itseraportoidun lääkärin totea-man masennuksen kuin masennuslääkeostojen perusteella. Tätä tulosta ei kuitenkaan pystytty toistamaan käyttämällä oman arvion sijasta työtoverien arviota työyhteisön sosiaalisesta pääomasta. Tutkimusta sosiaalisen pääoman vaikutusta masennuksen ilmaantumiseen jatkettiin selvittämällä miten sosiaalisen pääoman eri ulottuvuudet vaikuttivat masennuksen ilmaantumiseen. Tulosten mukaan sosiaalisen pääoman vertikaalinen komponentti (työntekijöiden ja esimiesten välinen luottamus, vastavuoroisuus ja jaetut arvot ja normit, jotka edesauttavat yhteistyötä) sekä horisontaalinen komponentti (työntekijöiden välisissä suhteissa yhteistyöstä, luottamuksesta ja vastavuoroisuudesta syntyvä sosiaalinen pääoma) vaikuttivat itsenäisesti masennusriskiin. Tutkimuksen perusteella korkea työyhteisön sosiaalinen pääoma saattaa vaikuttaa edullisesti työntekijöiden terveyteen. Jos näin on, olisi tärkeää edistää työyhteisöjen sosiaalista pääomaa ja kannustaa sellaiseen toimintaan, joka lisää suvaitsevaisuutta, luottamusta ja vastavuoroisuutta sekä työntekijöiden kesken että työntekijöiden ja esimiesten välillä.
Resumo:
El treball presentat ve motivat per la necessitat d’instal•lació d’un pàrquing públic i privat de nova construcció a nivell d’il•luminació i ventilació. Per poder satisfer les necessitats del nostre client d’estalvi energètic i confort en l’edifici es decideix d’implementar una instal•lació immòtica que és l’aplicació de tècniques de gestió i control automatitzat a un edifici terciari amb bus de comunicació KNX/EIB. Per a la il•luminació s’han utilitzat fluorescents amb balasts DALI, que permeten la seva regulació i control, per així poder adequar en tot moment l’encesa i intensitat de llum d’aquests. En quant a la ventilació s’han utilitzat variadors de freqüència per també poder optimitzar el funcionament dels ventiladors podent posar-los en marxa quan realment sigui necessari i a la potència que calgui. Per enllaçar tots els elements de la instal•lació, detectors i actuadors, sorgeig la necessitat d’implementar xarxes de comunicació com el KNX/EIB, DALI, Modbus i Ethernet. Per gestionar variables, comunicacions i controlar elements, s´hi han implementen dos autòmats programables a més d’un PC integrat per la visualització i el control del pàrquing. S’ha aconseguit de realitzar un pàrquing totalment automàtic on no és necessaria l’actuació dels operaris i amb les principals càrregues elèctriques totalment regulables en potència. S’ha comprovat que la instal•lació funciona per sota de la potència nominal de les càrregues amb l’estalvi energètic que això suposa.
Resumo:
Succeeding in small board lot (0-20 tons) deliveries, is not always prosperous and failures as well as extra costs compared to standard costs arise. Failure deliveries from converting plants to customer locations tie a lot of unwanted and unexpected costs. Extra costs are handled as quality costs and more precise, internal failure costs. These costs revolve from unsuccessful truck payloads, redundant warehousing or unfavorable routing as examples. Quality costs are becoming more and more important factor in company’s financial decision making. Actual, realized truck payload correlates with the extra costs occurring, so filling the truck payload all get-out well is a key to lower the extra costs. Case company in this study is Corporation A, business segment Boards. Boards have outsourced half of their converting in order to gain better customer service via flexibility, lead time reductions and logistics efficiency improvements. Examination period of the study is first two quarters of year 2008 and deliveries examined are from converters to the customer locations. In Corporation A’s case, the total loss in failure deliveries is hundreds of thousands of Euros during the examination period. So, the logistics goal of getting the right product to the right place and right time for the least cost, does not completely realize.
Resumo:
The maximum realizable power throughput of power electronic converters may be limited or constrained by technical or economical considerations. One solution to this problemis to connect several power converter units in parallel. The parallel connection can be used to increase the current carrying capacity of the overall system beyond the ratings of individual power converter units. Thus, it is possible to use several lower-power converter units, produced in large quantities, as building blocks to construct high-power converters in a modular manner. High-power converters realized by using parallel connection are needed for example in multimegawatt wind power generation systems. Parallel connection of power converter units is also required in emerging applications such as photovoltaic and fuel cell power conversion. The parallel operation of power converter units is not, however, problem free. This is because parallel-operating units are subject to overcurrent stresses, which are caused by unequal load current sharing or currents that flow between the units. Commonly, the term ’circulatingcurrent’ is used to describe both the unequal load current sharing and the currents flowing between the units. Circulating currents, again, are caused by component tolerances and asynchronous operation of the parallel units. Parallel-operating units are also subject to stresses caused by unequal thermal stress distribution. Both of these problemscan, nevertheless, be handled with a proper circulating current control. To design an effective circulating current control system, we need information about circulating current dynamics. The dynamics of the circulating currents can be investigated by developing appropriate mathematical models. In this dissertation, circulating current models aredeveloped for two different types of parallel two-level three-phase inverter configurations. Themodels, which are developed for an arbitrary number of parallel units, provide a framework for analyzing circulating current generation mechanisms and developing circulating current control systems. In addition to developing circulating current models, modulation of parallel inverters is considered. It is illustrated that depending on the parallel inverter configuration and the modulation method applied, common-mode circulating currents may be excited as a consequence of the differential-mode circulating current control. To prevent the common-mode circulating currents that are caused by the modulation, a dual modulator method is introduced. The dual modulator basically consists of two independently operating modulators, the outputs of which eventually constitute the switching commands of the inverter. The two independently operating modulators are referred to as primary and secondary modulators. In its intended usage, the same voltage vector is fed to the primary modulators of each parallel unit, and the inputs of the secondary modulators are obtained from the circulating current controllers. To ensure that voltage commands obtained from the circulating current controllers are realizable, it must be guaranteed that the inverter is not driven into saturation by the primary modulator. The inverter saturation can be prevented by limiting the inputs of the primary and secondary modulators. Because of this, also a limitation algorithm is proposed. The operation of both the proposed dual modulator and the limitation algorithm is verified experimentally.
Resumo:
A coupled system simulator, based on analytical circuit equations and a finite element method (FEM) model of the motor has been developed and it is used to analyse a frequency-converterfed industrial squirrel-cage induction motor. Two control systems that emulate the behaviour of commercial direct-torque-controlled (DTC) and vector-controlled industrial frequency converters have been studied, implemented in the simulation software and verified by extensive laboratory tests. Numerous factors that affect the operation of a variable speed drive (VSD) and its energy efficiency have been investigated, and their significance in the simulation of the VSD results has been studied. The dependency of the frequency converter, induction motor and system losses on the switching frequency is investigated by simulations and measurements at different speeds for both the vector control and the DTC. Intensive laboratory measurements have been carried out to verify the simulation results.
Resumo:
Concerns about condition of the environment and rising fossil fuel prices have accelerated the research of finding new cheap and environmental friendly energy source. Fuel cells are one of the most promising green technologies, especially in the field of distributed energy generation, backup power systems, transportation and mobile power generation. In this bachelor’s thesis use of fuel cells is studied, especially from the DC-DC converter point of view. This bachelor’s thesis concentrates on study of two different DC-DC converters. The aim of this thesis is to study design and steering methods for proposed converters. The ultimate aim of this thesis is to determine which one of proposed converters is most suitable for fuel cell applications.
Resumo:
The objective of this master's thesis is to compare two different generator systems for wind turbines. It is the doubly fed induction generator system with three stage gearbox and the direct drive permanent magnet generator system. The comparison of generator systems is based on annual energy production for a given wind climate. For comparison a 3 MW, 15 rpm wind turbine is used. Modelling of a turbine rotor, gearbox and converters were done. Design of two generators was done and their performance was examined.
Resumo:
Centrifugal pumps are widely used in industrial and municipal applications, and they are an important end-use application of electric energy. However, in many cases centrifugal pumps operate with a significantly lower energy efficiency than they actually could, which typically has an increasing effect on the pump energy consumption and the resulting energy costs. Typical reasons for this are the incorrect dimensioning of the pumping system components and inefficiency of the applied pump control method. Besides the increase in energy costs, an inefficient operation may increase the risk of a pump failure and thereby the maintenance costs. In the worst case, a pump failure may lead to a process shutdown accruing additional costs. Nowadays, centrifugal pumps are often controlled by adjusting their rotational speed, which affects the resulting flow rate and output pressure of the pumped fluid. Typically, the speed control is realised with a frequency converter that allows the control of the rotational speed of an induction motor. Since a frequency converter can estimate the motor rotational speed and shaft torque without external measurement sensors on the motor shaft, it also allows the development and use of sensorless methods for the estimation of the pump operation. Still today, the monitoring of pump operation is based on additional measurements and visual check-ups, which may not be applicable to determine the energy efficiency of the pump operation. This doctoral thesis concentrates on the methods that allow the use of a frequency converter as a monitoring and analysis device for a centrifugal pump. Firstly, the determination of energy-efficiency- and reliability-based limits for the recommendable operating region of a variable-speed-driven centrifugal pump is discussed with a case study for the laboratory pumping system. Then, three model-based estimation methods for the pump operating location are studied, and their accuracy is determined by laboratory tests. In addition, a novel method to detect the occurrence of cavitation or flow recirculation in a centrifugal pump by a frequency converter is introduced. Its sensitivity compared with known cavitation detection methods is evaluated, and its applicability is verified by laboratory measurements for three different pumps and by using two different frequency converters. The main focus of this thesis is on the radial flow end-suction centrifugal pumps, but the studied methods can also be feasible with mixed and axial flow centrifugal pumps, if allowed by their characteristics.
Resumo:
Keskitaajuudella toimivia muuntajia käytetään laajalti tehoelektroniikkasovelluksissa kuten DC/DC-konverttereissa ja muissa hakkuriteholähteissä. Muuntaja on induktiivinen komponentti, jonka magneettisen tasapainon säilyttäminen hakkuriteholähteissä on laitteen virheettömän toiminnan kannalta tärkeää. Muuntajaa syöttävän virtapiirin on muodostettava symmetrinen syöttöjännite, jotta muuntajan vuo ei ajaudu positiiviseen tai negatiiviseen kyllästykseen. Tässä diplomityössä esitetään muuntajan sähkömagneettinen toimintaperiaate, kyllästymisen syyt hakkuriteholähteissä sekä kehitetään aktiivinen ohjaus vuotasapainon säilyttämiseksi. Hakkuriteholähteissä käytettävissä muuntajissa on monesti useampi kuin kaksi käämiä. Tässä työssä tutkittavassa muuntajassa on useita ensiöitä ja useita toisioita ja muuntajaa syötetään keskitaajuudella. Tämä tuo uusia ongelmia verrattuna perinteiseen yksivaiheiseen DC/DC-konvertteriin. Näihin ongelmiin esitetään ratkaisut diplomityön tutkimuksessa.