983 resultados para 321023 Radiotherapy and Nuclear Medicine
Resumo:
Objective To evaluate and compare the intraobserver and interobserver reliability and agreement for the biparietal diameter (BPD), abdominal circumference (AC), femur length (FL) and estimated fetal weight (EFW) obtained by two-dimensional ultrasound (2D-US) and three-dimensional ultrasound (3D-US). Methods Singleton pregnant women between 24 and 40 weeks were invited to participate in this study. They were examined using 2D-US in a blinded manner, twice by one observer, intercalated by a scan by a second observer, to determine BPD, AC and FL. In each of the three examinations, three 3D-US datasets (head, abdomen and thigh) were acquired for measurements of the same parameters. We determined EFW using Hadlock's formula. Systematic errors between 3D-US and 2D-US were examined using the paired t-test. Reliability and agreement were assessed by intraclass correlation coefficients (ICCs), limits of agreement (LoA), SD of differences and proportion of differences below arbitrary points. Results We evaluated 102 singleton pregnancies. No significant systematic error between 2D-US and 3D-US was observed. The ICC values were higher for 3D-US in both intra- and interobserver evaluations; however, only for FL was there no overlap in the 95% CI. The LoA values were wider for 2D-US, suggesting that random errors were smaller when using 3D-US. Additionally, we observed that the SD values determined from 3D-US differences were smaller than those obtained for 2D-US. Higher proportions of differences were below the arbitrarily defined cut-off points when using 3D-US. Conclusion 3D-US improved the reliability and agreement of fetal measurements and EFW compared with 2D-US.
Resumo:
Objective To evaluate the intra- and interobserver reliability of assessment of three-dimensional power Doppler (3D-PD) indices from single spherical samples of the placenta. Methods Women with singleton pregnancies at 2440 weeks' gestation were included. Three scans were independently performed by two observers; Observer 1 performed the first and third scan, intercalated by the scan of Observer 2. The observers independently analyzed the 3D-PD datasets that they had previously acquired using four different methods, each using a spherical sample: random sample extending from basal to chorionic plate; random sample with 2 cm3 of volume; directed sample to the region subjectively determined as containing more color Doppler signals extending from basal to chorionic plate; or directed sample with 2 cm3 of volume. The vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were evaluated in each case. The observers were blinded to their own and each other's results. Additional evaluation was performed according to placental location: anterior, posterior and fundal or lateral. Intra- and interobserver reliability was assessed by intraclass correlation coefficients (ICC). Results Ninety-five pregnancies were included in the analysis. All three placental 3D-PD indices showed only weak to moderate reliability (ICC < 0.66 and ICC < 0.48, intra- and interobserver, respectively). The highest values of ICC were observed when using directed spherical samples from basal to chorionic plate. When analyzed by placental location, we found lower ICCs for lateral and fundal placentae compared to anterior and posterior ones. Conclusion Intra- and interobserver reliability of assessment of placental 3D-PD indices from single spherical samples in pregnant women greater than 24 weeks' gestation is poor to moderate, and clinical usefulness of these indices is likely to be limited. Copyright (c) 2012 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
A computational pipeline combining texture analysis and pattern classification algorithms was developed for investigating associations between high-resolution MRI features and histological data. This methodology was tested in the study of dentate gyrus images of sclerotic hippocampi resected from refractory epilepsy patients. Images were acquired using a simple surface coil in a 3.0T MRI scanner. All specimens were subsequently submitted to histological semiquantitative evaluation. The computational pipeline was applied for classifying pixels according to: a) dentate gyrus histological parameters and b) patients' febrile or afebrile initial precipitating insult history. The pipeline results for febrile and afebrile patients achieved 70% classification accuracy, with 78% sensitivity and 80% specificity [area under the reader observer characteristics (ROC) curve: 0.89]. The analysis of the histological data alone was not sufficient to achieve significant power to separate febrile and afebrile groups. Interesting enough, the results from our approach did not show significant correlation with histological parameters (which per se were not enough to classify patient groups). These results showed the potential of adding computational texture analysis together with classification methods for detecting subtle MRI signal differences, a method sufficient to provide good clinical classification. A wide range of applications of this pipeline can also be used in other areas of medical imaging. Magn Reson Med, 2012. (c) 2012 Wiley Periodicals, Inc.
Resumo:
Background: Despite advances in supportive care, sepsis-related mortality remains high, especially in patients with acute kidney injury (AKI). Erythropoietin can protect organs against ischemia and sepsis. This effect has been linked to activation of intracellular survival pathways, although the mechanism remains unclear. Continuous erythropoietin receptor activator (CERA) is an erythropoietin with a unique pharmacologic profile and long half-life. We hypothesized that pretreatment with CERA would be renoprotective in the cecal ligation and puncture (CLP) model of sepsis-induced AKI. Methods: Rats were randomized into three groups: control; CLP; and CLP+CERA (5 mu g/kg body weight, i.p. administered 24 h before CLP). At 24 hours after CLP, we measured creatinine clearance, biochemical variables, and hemodynamic parameters. In kidney tissue, we performed immunoblotting-to quantify expression of the Na-K-2Cl cotransporter (NKCC2), aquaporin 2 (AQP2), Toll-like receptor 4 (TLR4), erythropoietin receptor (EpoR), and nuclear factor kappa B (NF-kappa B)-and immunohistochemical staining for CD68 (macrophage infiltration). Plasma interleukin (IL)-2, IL-1 beta, IL-6, IL-10, interferon gamma, and tumor necrosis factor alpha were measured by multiplex detection. Results: Pretreatment with CERA preserved creatinine clearance and tubular function, as well as the expression of NKCC2 and AQP2. In addition, CERA maintained plasma lactate at normal levels, as well as preserving plasma levels of transaminases and lactate dehydrogenase. Renal expression of TLR4 and NF-kappa B was lower in CLP+CERA rats than in CLP rats (p<0.05 and p<0.01, respectively), as were CD68-positive cell counts (p<0.01), whereas renal EpoR expression was higher (p<0.05). Plasma levels of all measured cytokines were lower in CLP+CERA rats than in CLP rats. Conclusion: CERA protects against sepsis-induced AKI. This protective effect is, in part, attributable to suppression of the inflammatory response.
Resumo:
Objective To evaluate whether the presence of polycystic ovary syndrome (PCOS) alters multiple ultrasonographic and laboratory markers of metabolic and cardiovascular disease risk in obese women without any other health condition that could interfere with combined oral contraceptive (COC) eligibility criteria. Methods This was a case- control study evaluating 90 obese women ( body mass index ( BMI) = 30.0 kg/m2 and < 40 kg/m2) aged between 18 and 40 years without any other health condition that could interfere with COC eligibility criteria, of whom 45 had PCOS and 45 were age- matched controls. BMI, waist and hip circumference, arterial blood pressure, fasting insulin and glucose, quantitative insulin sensitivity check index ( QUICKI), highdensity lipoprotein cholesterol, low- density lipoprotein cholesterol, total cholesterol, triglycerides, testosterone, sex hormone- binding globulin, free androgen index ( FAI), carotid stiffness index, intima media thickness, flowmediated dilatation ( FMD) of the brachial artery and non- alcoholic fatty liver disease ( NAFLD) were assessed. Results In women with PCOS, we observed a higher frequency of NAFLD ( 73.3 vs. 46.7%, P < 0.01) and higher FAI ( 10.4 vs. 6.8%, P < 0.01). We also observed a trend towards increased insulin levels ( 10.06 +/- 6.66 vs. 7.45 +/- 5.88 mu IU/mL, P = 0.05), decreased QUICKI ( 0.36 +/- 0.06 vs. 0.39 +/- 0.07, P = 0.05) and decreased FMD ( 7.00 +/- 3.87 vs. 8.41 +/- 3.79%, P = 0.08). No other significant difference was observed. Conclusions NAFLD is frequent in obese women without any other health condition that could interfere with COC eligibility criteria, especially in those with PCOS. This should be considered when choosing the best contraceptive option. Copyright (C) 2012 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
Objectives To evaluate the accuracy and probabilities of different fetal ultrasound parameters to predict neonatal outcome in isolated congenital diaphragmatic hernia (CDH). Methods Between January 2004 and December 2010, we evaluated prospectively 108 fetuses with isolated CDH (82 left-sided and 26 right-sided). The following parameters were evaluated: gestational age at diagnosis, side of the diaphragmatic defect, presence of polyhydramnios, presence of liver herniated into the fetal thorax (liver-up), lung-to-head ratio (LHR) and observed/expected LHR (o/e-LHR), observed/expected contralateral and total fetal lung volume (o/e-ContFLV and o/e-TotFLV) ratios, ultrasonographic fetal lung volume/fetal weight ratio (US-FLW), observed/expected contralateral and main pulmonary artery diameter (o/e-ContPA and o/eMPA) ratios and the contralateral vascularization index (Cont-VI). The outcomes were neonatal death and severe postnatal pulmonary arterial hypertension (PAH). Results Neonatal mortality was 64.8% (70/108). Severe PAH was diagnosed in 68 (63.0%) cases, of which 63 died neonatally (92.6%) (P < 0.001). Gestational age at diagnosis, side of the defect and polyhydramnios were not associated with poor outcome (P > 0.05). LHR, o/eLHR, liver-up, o/e-ContFLV, o/e-TotFLV, US-FLW, o/eContPA, o/e-MPA and Cont-VI were associated with both neonatal death and severe postnatal PAH (P < 0.001). Receiver-operating characteristics curves indicated that measuring total lung volumes (o/e-TotFLV and US-FLW) was more accurate than was considering only the contralateral lung sizes (LHR, o/e-LHR and o/e-ContFLV; P < 0.05), and Cont-VI was the most accurate ultrasound parameter to predict neonatal death and severe PAH (P < 0.001). Conclusions Evaluating total lung volumes is more accurate than is measuring only the contralateral lung size. Evaluating pulmonary vascularization (Cont-VI) is the most accurate predictor of neonatal outcome. Estimating the probability of survival and severe PAH allows classification of cases according to prognosis. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
Modifications in low-density lipoprotein (LDL) have emerged as a major pathogenic factor of atherosclerosis, which is the main cause of morbidity and mortality in the western world. Measurements of the heat diffusivity of human LDL solutions in their native and in vitro oxidized states are presented by using the Z-Scan (ZS) technique. Other complementary techniques were used to obtain the physical parameters necessary to interpret the optical results, e. g., pycnometry, refractometry, calorimetry, and spectrophotometry, and to understand the oxidation phase of LDL particles. To determine the sample's thermal diffusivity using the thermal lens model, an iterative one-parameter fitting method is proposed which takes into account several characteristic ZS time-dependent and the position-dependent transmittance measurements. Results show that the thermal diffusivity increases as a function of the LDL oxidation degree, which can be explained by the increase of the hydroperoxides production due to the oxidation process. The oxidation products go from one LDL to another, disseminating the oxidation process and caring the heat across the sample. This phenomenon leads to a quick thermal homogenization of the sample, avoiding the formation of the thermal lens in highly oxidized LDL solutions. (C) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.JBO.17.10.105003]
Resumo:
Purpose: Myelodysplastic syndromes (MDS) are a group of disorders characterized by cytopenias, with a propensity for evolution into acute myeloid leukemias (AML). This transformation is driven by genomic instability, but mechanisms remain unknown. Telomere dysfunction might generate genomic instability leading to cytopenias and disease progression. Experimental Design: We undertook a pilot study of 94 patients with MDS (56 patients) and AML (38 patients). The MDS cohort consisted of refractory cytopenia with multilineage dysplasia (32 cases), refractory anemia (12 cases), refractory anemia with excess of blasts (RAEB) 1 (8 cases), RAEB2 (1 case), refractory anemia with ring sideroblasts (2 cases), and MDS with isolated del(5q) (1 case). The AML cohort was composed of AML-M4 (12 cases), AML-M2 (10 cases), AML-M5 (5 cases), AML-M0 (5 cases), AML-M1 (2 cases), AML-M4eo (1 case), and AML with multidysplasia-related changes (1 case). Three-dimensional quantitative FISH of telomeres was carried out on nuclei from bone marrow samples and analyzed using TeloView. Results: We defined three-dimensional nuclear telomeric profiles on the basis of telomere numbers, telomeric aggregates, telomere signal intensities, nuclear volumes, and nuclear telomere distribution. Using these parameters, we blindly subdivided the MDS patients into nine subgroups and the AML patients into six subgroups. Each of the parameters showed significant differences between MDS and AML. Combining all parameters revealed significant differences between all subgroups. Three-dimensional telomeric profiles are linked to the evolution of telomere dysfunction, defining a model of progression from MDS to AML. Conclusions: Our results show distinct three-dimensional telomeric profiles specific to patients with MDS and AML that help subgroup patients based on the severity of telomere dysfunction highlighted in the profiles. Clin Cancer Res; 18(12); 3293-304. (C) 2012 AACR.
Resumo:
Objectives: Previous evidence supports a direct relationship between the calcium burden (volume) on post-contrast CT with the percent internal carotid artery (ICA) stenosis at the carotid bifurcation. We sought to further investigate this relationship by comparing non-enhanced CT (NECT) and digital subtraction angiography (DSA). Methods: 50 patients (aged 41-82 years) were retrospectively identified who had undergone cervical NECT and DSA. A 64-multidetector array CT (MDCT) scanner was utilised and the images reviewed using preset window widths/levels (30/300) optimised to calcium, with the volumes measured via three-dimensional reconstructive software. Stenosis measurements were performed on DSA and luminal diameter stenoses >40% were considered "significant". Volume thresholds of 0.01, 0.03, 0.06, 0.09 and 0.12 cm(3) were utilised and Pearson's correlation coefficient (r) was calculated to correlate the calcium volume with percent stenosis. Results: Of 100 carotid bifurcations, 88 were available and of these 7 were significantly stenotic. The NECT calcium volume moderately correlated with percent stenosis on DSA r=0.53 (p<0.01). A moderate-strong correlation was found between the square root of calcium volume on NECT with percent stenosis on DSA (r=0.60, p<0.01). Via a receiver operating characteristic curve, 0.06 cm(3) was determined to be the best threshold (sensitivity 100%, specificity 90.1%, negative predictive value 100% and positive predictive value 46.7%) for detecting significant stenoses. Conclusion: This preliminary investigation confirms a correlation between carotid bifurcation calcium volume and percent ICA stenosis and is promising for the optimal threshold for stenosis detection. Future studies could utilise calcium volumes to create a "score" that could predict high grade stenosis.
Resumo:
Abstract Background In patients with advanced non-ischemic cardiomyopathy (NIC), right-sided cardiac disturbances has prognostic implications. Right coronary artery (RCA) flow pattern and flow reserve (CFR) are not well known in this setting. The purpose of this study was to assess, in human advanced NIC, the RCA phasic flow pattern and CFR, also under right-sided cardiac disturbances, and compare with left coronary circulation. As well as to investigate any correlation between the cardiac structural, mechanical and hemodynamic parameters with RCA phasic flow pattern or CFR. Methods Twenty four patients with dilated severe NIC were evaluated non-invasively, even by echocardiography, and also by cardiac catheterization, inclusive with Swan-Ganz catheter. Intracoronary Doppler (Flowire) data was obtained in RCA and left anterior descendent coronary artery (LAD) before and after adenosine. Resting RCA phasic pattern (diastolic/systolic) was compared between subgroups with and without pulmonary hypertension, and with and without right ventricular (RV) dysfunction; and also with LAD. RCA-CFR was compared with LAD, as well as in those subgroups. Pearson's correlation analysis was accomplished among echocardiographic (including LV fractional shortening, mass index, end systolic wall stress) more hemodynamic parameters with RCA phasic flow pattern or RCA-CFR. Results LV fractional shortening and end diastolic diameter were 15.3 ± 3.5 % and 69.4 ± 12.2 mm. Resting RCA phasic pattern had no difference comparing subgroups with vs. without pulmonary hypertension (1.45 vs. 1.29, p = NS) either with vs. without RV dysfunction (1.47 vs. 1.23, p = NS); RCA vs. LAD was 1.35 vs. 2.85 (p < 0.001). It had no significant correlation among any cardiac mechanical or hemodynamic parameter with RCA-CFR or RCA flow pattern. RCA-CFR had no difference compared with LAD (3.38 vs. 3.34, p = NS), as well as in pulmonary hypertension (3.09 vs. 3.10, p = NS) either in RV dysfunction (3.06 vs. 3.22, p = NS) subgroups. Conclusion In patients with chronic advanced NIC, RCA phasic flow pattern has a mild diastolic predominance, less marked than in LAD, with no effects from pulmonary artery hypertension or RV dysfunction. There is no significant correlation between any cardiac mechanical-structural or hemodynamic parameter with RCA-CFR or RCA phasic flow pattern. RCA flow reserve is still similar to LAD, independently of those right-sided cardiac disturbances.
Resumo:
Micelles composed of amphiphilic copolymers linked to a radioactive element are used in nuclear medicine predominantly as a diagnostic application. A relevant advantage of polymeric micelles in aqueous solution is their resulting particle size, which can vary from 10 to 100 nm in diameter. In this review, polymeric micelles labeled with radioisotopes including technetium (99mTc) and indium (111In), and their clinical applications for several diagnostic techniques, such as single photon emission computed tomography (SPECT), gamma-scintigraphy, and nuclear magnetic resonance (NMR), were discussed. Also, micelle use primarily for the diagnosis of lymphatic ducts and sentinel lymph nodes received special attention. Notably, the employment of these diagnostic techniques can be considered a significant tool for functionally exploring body systems as well as investigating molecular pathways involved in the disease process. The use of molecular modeling methodologies and computer-aided drug design strategies can also yield valuable information for the rational design and development of novel radiopharmaceuticals.
Resumo:
Radiometals play an important role in nuclear medicine as involved in diagnostic or therapeutic agents. In the present work the radiochemical aspects of production and processing of very promising radiometals of the third group of the periodic table, namely radiogallium and radiolanthanides are investigated. The 68Ge/68Ga generator (68Ge, T½ = 270.8 d) provides a cyclotron-independent source of positron-emitting 68Ga (T½ = 68 min), which can be used for coordinative labelling. However, for labelling of biomolecules via bifunctional chelators, particularly if legal aspects of production of radiopharmaceuticals are considered, 68Ga(III) as eluted initially needs to be pre-concentrated and purified. The first experimental chapter describes a system for simple and efficient handling of the 68Ge/68Ga generator eluates with a cation-exchange micro-chromatography column as the main component. Chemical purification and volume concentration of 68Ga(III) are carried out in hydrochloric acid – acetone media. Finally, generator produced 68Ga(III) is obtained with an excellent radiochemical and chemical purity in a minimised volume in a form applicable directly for the synthesis of 68Ga-labelled radiopharmaceuticals. For labelling with 68Ga(III), somatostatin analogue DOTA-octreotides (DOTATOC, DOTANOC) are used. 68Ga-DOTATOC and 68Ga-DOTANOC were successfully used to diagnose human somatostatin receptor-expressing tumours with PET/CT. Additionally, the proposed method was adapted for purification and medical utilisation of the cyclotron produced SPECT gallium radionuclide 67Ga(III). Second experimental chapter discusses a diagnostic radiolanthanide 140Nd, produced by irradiation of macro amounts of natural CeO2 and Pr2O3 in natCe(3He,xn)140Nd and 141Pr(p,2n)140Nd nuclear reactions, respectively. With this produced and processed 140Nd an efficient 140Nd/140Pr radionuclide generator system has been developed and evaluated. The principle of radiochemical separation of the mother and daughter radiolanthanides is based on physical-chemical transitions (hot-atom effects) of 140Pr following the electron capture process of 140Nd. The mother radionuclide 140Nd(III) is quantitatively absorbed on a solid phase matrix in the chemical form of 140Nd-DOTA-conjugated complexes, while daughter nuclide 140Pr is generated in an ionic species. With a very high elution yield and satisfactory chemical and radiolytical stability the system could able to provide the short-lived positron-emitting radiolanthanide 140Pr for PET investigations. In the third experimental chapter, analogously to physical-chemical transitions after the radioactive decay of 140Nd in 140Pr-DOTA, the rapture of the chemical bond between a radiolanthanide and the DOTA ligand, after the thermal neutron capture reaction (Szilard-Chalmers effect) was evaluated for production of the relevant radiolanthanides with high specific activity at TRIGA II Mainz nuclear reactor. The physical-chemical model was developed and first quantitative data are presented. As an example, 166Ho could be produced with a specific activity higher than its limiting value for TRIGA II Mainz, namely about 2 GBq/mg versus 0.9 GBq/mg. While free 166Ho(III) is produced in situ, it is not forming a 166Ho-DOTA complex and therefore can be separated from the inactive 165Ho-DOTA material. The analysis of the experimental data shows that radionuclides with half-life T½ < 64 h can be produced on TRIGA II Mainz nuclear reactor, with specific activity higher than any available at irradiation of simple targets e.g. oxides.
Resumo:
Nuclear medicine imaging techniques such as PET are of increasing relevance in pharmaceutical research being valuable (pre)clinical tools to non-invasively assess drug performance in vivo. Therapeutic drugs, e.g. chemotherapeutics, often suffer from a poor balance between their efficacy and toxicity. Here, polymer based drug delivery systems can modulate the pharmacokinetics of low Mw therapeutics (prolonging blood circulation time, reducing toxic side effects, increasing target site accumulation) and therefore leading to a more efficient therapy. In this regard, poly-N-(2-hydroxypropyl)-methacrylamide (HPMA) constitutes a promising biocompatible polymer. Towards the further development of these structures, non-invasive PET imaging allows insight into structure-property relationships in vivo. This performant tool can guide design optimization towards more effective drug delivery. Hence, versatile radiolabeling strategies need to be developed and establishing 18F- as well as 131I-labeling of diverse HPMA architectures forms the basis for short- as well as long-term in vivo evaluations. By means of the prosthetic group [18F]FETos, 18F-labeling of distinct HPMA polymer architectures (homopolymers, amphiphilic copolymers as well as block copolymers) was successfully accomplished enabling their systematic evaluation in tumor bearing rats. These investigations revealed pronounced differences depending on individual polymer characteristics (molecular weight, amphiphilicity due to incorporated hydrophobic laurylmethacrylate (LMA) segments, architecture) as well as on the studied tumor model. Polymers showed higher uptake for up to 4 h p.i. into Walker 256 tumors vs. AT1 tumors (correlating to a higher cellular uptake in vitro). Highest tumor concentrations were found for amphiphilic HPMA-ran-LMA copolymers in comparison to homopolymers and block copolymers. Notably, the random LMA copolymer P4* (Mw=55 kDa, 25% LMA) exhibited most promising in vivo behavior such as highest blood retention as well as tumor uptake. Further studies concentrated on the influence of PEGylation (‘stealth effect’) in terms of improving drug delivery properties of defined polymeric micelles. Here, [18F]fluoroethylation of distinct PEGylated block copolymers (0%, 1%, 5%, 7%, 11% of incorporated PEG2kDa) enabled to systematically study the impact of PEG incorporation ratio and respective architecture on the in vivo performance. Most strikingly, higher PEG content caused prolonged blood circulation as well as a linear increase in tumor uptake (Walker 256 carcinoma). Due to the structural diversity of potential polymeric carrier systems, further versatile 18F-labeling strategies are needed. Therefore, a prosthetic 18F-labeling approach based on the Cu(I)-catalyzed click reaction was established for HPMA-based polymers, providing incorporation of fluorine-18 under mild conditions and in high yields. On this basis, a preliminary µPET study of a HPMA-based polymer – radiolabeled via the prosthetic group [18F]F-PEG3-N3 – was successfully accomplished. By revealing early pharmacokinetics, 18F-labeling enables to time-efficiently assess the potential of HPMA polymers for efficient drug delivery. Yet, investigating the long-term fate is essential, especially regarding prolonged circulation properties and passive tumor accumulation (EPR effect). Therefore, radiolabeling of diverse HPMA copolymers with the longer-lived isotope iodine-131 was accomplished enabling in vivo evaluation of copolymer P4* over several days. In this study, tumor retention of 131I-P4* could be demonstrated at least over 48h with concurrent blood clearance thereby confirming promising tumor targeting properties of amphiphilic HPMA copolymer systems based on the EPR effect.
Resumo:
Die Nuklearmedizin ist ein modernes und effektives Werkzeug zur Erkennung und Behandlung von onkologischen Erkrankungen. Molekulare Bildgebung, die auf dem Einsatz von Radiopharmaka basiert, beinhaltet die Einzel-Photonen-Emissions-Tomographie (SPECT) und Positronenemissions¬tomographie (PET) und ermöglicht die nicht-invasive Visualisierung von Tumoren auf nano-und picomolarer Ebene.rnDerzeit werden viele neue Tracer für die genauere Lokalisierung von kleinen Tumoren und Metastasen eingeführt und hinsichtlich ihrer Eignung untersucht. Die meisten von ihnen sind Protein-basierte Biomoleküle, die die Natur selbst als Antigene für die Tumorzellen produziert. Dabei spielen Antikörper und Antikörper-Fragmente eine wichtige Rolle in der Tumor-Diagnostik und Behandlung. Die PET-Bildgebung mit Antikörpern und Antikörperfragmenten bezeichnet man als immuno-PET. Ein wichtiger Aspekt hierbei ist, dass entsprechende Radiopharmaka benötigt werden, deren Halbwertszeit mit der Halbwertszeit der Biomoleküle korreliert ist.rnIn neueren Arbeiten wird 90Nb als potenzieller Kandidat für die Anwendung in der immuno-PET vorgeschlagen. Seine Halbwertszeit von 14,6 Stunden ist geeignet für die Anwendung mit Antikörperfragmenten und einige intakten Antikörpern. 90Nb hat eine relativ hohen Anteil an Positronenemission von 53% und eine optimale Energie für die β+-Emission von 0,35 MeV, die sowohl eine hohe Qualität der Bildgebung als auch eine niedrige Aktivitätsmenge des Radionuklids ermöglicht.rnErsten grundlegende Untersuchungen zeigten: i) dass 90Nb in ausreichender Menge und Reinheit durch Protonen-Bombardierung des natürlichen Zirkonium Targets produziert, ii) aus dem Targetmaterial in entsprechender radiochemischer Reinheit isoliert und iii) zur Markierung des monoklonalen Antikörpers (Rituximab) verwendet werden kann und iv) dieser 90Nb-markierte mAb eine hohe in vitro Stabilität besitzt. Desweiteren wurde eine alternative und schnelle Abtrennungsmethode entwickelt, die es erlaubt 90Nb, mit einer geeigneten radiochemischen und radionuklidischen Reinheit für eine anschließende Markierung von Biomolekülen in einer Stunde zu aufzureinigen. Schließlich wurden erstmals 90Nb-markierte Biomolekülen in vivo untersucht. Desweiteren wurden auch Experimente durchgeführt, um den optimalen bifunktionellen Chelatbildner (BFC) für 90Niob zu finden. Mehrere BFC wurden hinsichtlich Komplexbildung mit NbV untersucht. Desferrioxamin (Df) erwies sich als geeignetster Chelator für 90Nb. Der monoklonale Antikörper Bevacizumab (Avastin®) wurde mit 90Nb markiert und eine Biodistributionsstudie und eine PET-Untersuchung durchgeführt. Alle diese Ergebnisse zeigten, dass 90Nb ein vielversprechendes Radionuklid für die Immuno-PET ist, welches sogar für weitere kommerzielle Anwendungen in der klinischen Routine geeignet zu sein scheint.rn
Resumo:
In a minority of cases a definite diagnosis and stage grouping in cancer patients is not possible based on the imaging information of PET/CT. We report our experience with percutaneous PET/CT-guided bone biopsies to histologically verify the aetiology of hypermetabolic bone lesions.