982 resultados para retrograde orbit


Relevância:

10.00% 10.00%

Publicador:

Resumo:

An electronic theory is developed, which describes the ultrafast demagnetization in itinerant ferromagnets following the absorption of a femtosecond laser pulse. The present work intends to elucidate the microscopic physics of this ultrafast phenomenon by identifying its fundamental mechanisms. In particular, it aims to reveal the nature of the involved spin excitations and angular-momentum transfer between spin and lattice, which are still subjects of intensive debate. In the first preliminary part of the thesis the initial stage of the laser-induced demagnetization process is considered. In this stage the electronic system is highly excited by spin-conserving elementary excitations involved in the laser-pulse absorption, while the spin or magnon degrees of freedom remain very weakly excited. The role of electron-hole excitations on the stability of the magnetic order of one- and two-dimensional 3d transition metals (TMs) is investigated by using ab initio density-functional theory. The results show that the local magnetic moments are remarkably stable even at very high levels of local energy density and, therefore, indicate that these moments preserve their identity throughout the entire demagnetization process. In the second main part of the thesis a many-body theory is proposed, which takes into account these local magnetic moments and the local character of the involved spin excitations such as spin fluctuations from the very beginning. In this approach the relevant valence 3d and 4p electrons are described in terms of a multiband model Hamiltonian which includes Coulomb interactions, interatomic hybridizations, spin-orbit interactions, as well as the coupling to the time-dependent laser field on the same footing. An exact numerical time evolution is performed for small ferromagnetic TM clusters. The dynamical simulations show that after ultra-short laser pulse absorption the magnetization of these clusters decreases on a time scale of hundred femtoseconds. In particular, the results reproduce the experimentally observed laser-induced demagnetization in ferromagnets and demonstrate that this effect can be explained in terms of the following purely electronic non-adiabatic mechanism: First, on a time scale of 10–100 fs after laser excitation the spin-orbit coupling yields local angular-momentum transfer between the spins and the electron orbits, while subsequently the orbital angular momentum is very rapidly quenched in the lattice on the time scale of one femtosecond due to interatomic electron hoppings. In combination, these two processes result in a demagnetization within hundred or a few hundred femtoseconds after laser-pulse absorption.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The magnetic properties and interactions between transition metal (TM) impurities and clusters in low-dimensional metallic hosts are studied using a first principles theoretical method. In the first part of this work, the effect of magnetic order in 3d-5d systems is addressed from the perspective of its influence on the enhancement of the magnetic anisotropy energy (MAE). In the second part, the possibility of using external electric fields (EFs) to control the magnetic properties and interactions between nanoparticles deposited at noble metal surfaces is investigated. The influence of 3d composition and magnetic order on the spin polarization of the substrate and its consequences on the MAE are analyzed for the case of 3d impurities in one- and two-dimensional polarizable hosts. It is shown that the MAE and easy- axis of monoatomic free standing 3d-Pt wires is mainly determined by the atomic spin-orbit (SO) coupling contributions. The competition between ferromagnetic (FM) and antiferromagnetic (AF) order in FePtn wires is studied in detail for n=1-4 as a function of the relative position between Fe atoms. Our results show an oscillatory behavior of the magnetic polarization of Pt atoms as a function of their distance from the magnetic impurities, which can be correlated to a long-ranged magnetic coupling of the Fe atoms. Exceptionally large variations of the induced spin and orbital moments at the Pt atoms are found as a function of concentration and magnetic order. Along with a violation of the third Hund’s rule at the Fe sites, these variations result in a non trivial behavior of the MAE. In the case of TM impurities and dimers at the Cu(111), the effects of surface charging and applied EFs on the magnetic properties and substrate-mediated magnetic interactions have been investigated. The modifications of the surface electronic structure, impurity local moments and magnetic exchange coupling as a result of the EF-induced metallic screening and charge rearrangements are analysed. In a first study, the properties of surface substitutional Co and Fe impurities are investigated as a function of the external charge per surface atom q. At large inter-impurity distances the effective magnetic exchange coupling ∆E between impurities shows RKKY-like oscillations as a function of the distance which are not significantly affected by the considered values of q. For distances r < 10 Å, important modifications in the magnitude of ∆E, involving changes from FM to AF coupling, are found depending non-monotonously on the value and polarity of q. The interaction energies are analysed from a local perspective. In a second study, the interplay between external EF effects, internal magnetic order and substrate-mediated magnetic coupling has been investigated for Mn dimers on Cu(111). Our calculations show that EF (∼ 1eV/Å) can induce a switching from AF to FM ground-state magnetic order within single Mn dimers. The relative coupling between a pair of dimers also shows RKKY-like oscillations as a function of the inter-dimer distance. Their effective magnetic exchange interaction is found to depend significantly on the magnetic order within the Mn dimers and on their relative orientation on the surface. The dependence of the substrate-mediated interaction on the magnetic state of the dimers is qualitatively explained in terms of the differences in the scattering of surface electrons. At short inter-dimer distances, the ground-state configuration is determined by an interplay between exchange interactions and EF effects. These results demonstrate that external surface charging and applied EFs offer remarkable possibilities of manipulating the sign and strength of the magnetic coupling of surface supported nanoparticles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

KAM is a computer program that can automatically plan, monitor, and interpret numerical experiments with Hamiltonian systems with two degrees of freedom. The program has recently helped solve an open problem in hydrodynamics. Unlike other approaches to qualitative reasoning about physical system dynamics, KAM embodies a significant amount of knowledge about nonlinear dynamics. KAM's ability to control numerical experiments arises from the fact that it not only produces pictures for us to see, but also looks at (sic---in its mind's eye) the pictures it draws to guide its own actions. KAM is organized in three semantic levels: orbit recognition, phase space searching, and parameter space searching. Within each level spatial properties and relationships that are not explicitly represented in the initial representation are extracted by applying three operations ---(1) aggregation, (2) partition, and (3) classification--- iteratively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present an experimental study on the behavior of bubbles captured in a Taylor vortex. The gap between a rotating inner cylinder and a stationary outer cylinder is filled with a Newtonian mineral oil. Beyond a critical rotation speed (ω[subscript c]), Taylor vortices appear in this system. Small air bubbles are introduced into the gap through a needle connected to a syringe pump. These are then captured in the cores of the vortices (core bubble) and in the outflow regions along the inner cylinder (wall bubble). The flow field is measured with a two-dimensional particle imaging velocimetry (PIV) system. The motion of the bubbles is monitored by using a high speed video camera. It has been found that, if the core bubbles are all of the same size, a bubble ring forms at the center of the vortex such that bubbles are azimuthally uniformly distributed. There is a saturation number (N[subscript s]) of bubbles in the ring, such that the addition of one more bubble leads eventually to a coalescence and a subsequent complicated evolution. Ns increases with increasing rotation speed and decreasing bubble size. For bubbles of non-uniform size, small bubbles and large bubbles in nearly the same orbit can be observed to cross due to their different circulating speeds. The wall bubbles, however, do not become uniformly distributed, but instead form short bubble-chains which might eventually evolve into large bubbles. The motion of droplets and particles in a Taylor vortex was also investigated. As with bubbles, droplets and particles align into a ring structure at low rotation speeds, but the saturation number is much smaller. Moreover, at high rotation speeds, droplets and particles exhibit a characteristic periodic oscillation in the axial, radial and tangential directions due to their inertia. In addition, experiments with non-spherical particles show that they behave rather similarly. This study provides a better understanding of particulate behavior in vortex flow structures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La coledocolitiasis es una patología que requiere una aproximación adecuada para determinar su manejo dadas las posibles complicaciones por omisión en su diagnostico o la realización de procedimientos terapéuticos. La colangiopancreatografía retrógrada endoscópica (CPRE) es una opción en su manejo, pero es un procedimiento invasivo con riesgos de morbilidad y mortalidad considerables. El objetivo del estudio es determinar la correlación existente entre los resultados de pruebas serológicas, el diámetro hallado de la vía biliar por ecografía, así como el diagnostico radiológico de coledocolitiasis y las CPRE realizadas en el Hospital Universitario de la Samaritana (HUS) entre el 01/05/2009 y 31/08/2010. Materiales y Método: Estudio de concordancia de pruebas diagnósticas. Donde a través de la recolección de la información a través de un cuestionario sobre identificación de pacientes con diagnóstico presuntivo de coledocolitiasis, resultados serológicos, hallazgos ecográficos de la vía biliar y el reporte de CPRE se realizo un análisis descriptivo de la población, se calcularon los valores de sensibilidad, especificidad y cocientes de probabilidades, además de determinar el grado de concordancia entre las pruebas utilizando los paquetes estadísticos Stata v. 11 (StataCorp; Tx, USA) y SPSS v. 18 (SPSS Inc.; Ill, USA) Dada la evidencia actual ningún indicador utilizado de forma única (historia clínica, ecografía, marcadores serológicos) es capaz de determinar el diagnostico de coledocolitiasis con suficiente precisión, sin embargo en pacientes mayores cuya clínica sugiere patología biliar obstructiva, existen algunos puntos de corte que hacen parte de algoritmos en la literatura, los cuales son una guía para determinar la necesidad de CPRE y se pueden utilizar en nuestra institución

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Exercises and solutions in PDF

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Exercises and solutions in PDF

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Exercises and solutions in LaTex

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Exercises and solutions in LaTex

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La pancreatitis aguda (PA) es una patología clínica común que abarca un espectro desde leve hasta fatal, donde se produce una inflamación del páncreas por auto digestión enzimática con grado variable de compromiso sistémico. Es una emergencia abdominal grave con una mortalidad del 9-23%. En el 40% de los casos de pancreatitis aguda se encuentra que es de origen biliar. La prevalencia de enfermedad biliar a nivel mundial en adultos varía entre 5,9% y 21,9%, con grandes variaciones geográficas y regionales, se encuentran en el 12% de los hombres y el 24% de las mujeres. La prevalencia aumenta con la edad. Latinoamérica es una región con alta prevalencia. En pacientes con colelitiasis del 5-15 % tienen coledocolitiasis. La alta prevalencia de la patología biliar en nuestro país hace que esta sea una causa frecuente de consulta médica por dolor abdominal. El factor común presente en la gran mayoría de las enfermedades de la vía biliar es la Colelitiasis. La complicación más frecuente, la Coledocolitiasis, se ha reportado con cifras hasta de un 20% y como complicación de esta la pancreatitis. La pancreatitis aguda de origen biliar (PAB) es causada por una obstrucción transitoria o persistente de la ampolla de Váter por barro biliar o por cálculos. En el diagnostico de la PAB se emplean métodos invasivos como la colangiopancreaticografia endoscópica retrograda (CPRE) la cual trae consigo morbilidad y mortalidad asociada y métodos no invasivos como la colangiopancreaticografia magnética (CRM) que emerge como modalidad prometedora en el diagnostico y manejo de la PAB en centros de tercer y cuarto nivel de complejidad. El manejo actual de la PAB es la remoción de la obstrucción del conducto biliar común (CBC) seguida de su tratamiento definitivo, la colecistectomía o CPRE con papilotomia. En nuestro país no se han publicado estudios con datos locales acerca de la utilidad de la CRM para la detección de coledocolitiasis, en las guías de manejo de coledocolitiasis de la asociación colombiana de cirugía publicadas en el año 2004, hace referencia de la utilidad de la CRM para el diagnostico de esta entidad tomando como base una revisión sistemática de estudios publicados en Medline, Pubmed y Cocrane los cuales no incluyen experiencia a nivel nacional. En este estudio pretendimos determinar cuáles son los pacientes que se benefician de la realización de CRM temprana en el marco de la PAB leve para la detección de coledocolitiasis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCCION: La obstrucción biliar es la principal causa de pancreatitis aguda y su curso es moderado a leve aunque un 20% desarrollan formas severas. La remoción de los cálculos por CPRE se ha empleado como terapéutica aunque su rol es controversial y no se ha demostrado su utilidad en forma temprana. El propósito de este estudio es observar la evolución de los pacientes con PASB en quienes se realice CPRE con respecto al curso de la enfermedad. METODOLOGIA: Estudio retrospectivo observacional descriptivo en pacientes con PASB llevados a CPRE. Entre junio y octubre de 2012 se encontraron 72 pacientes con PASB y patrón biliar obstructivo, 49 (68.06%) en los cuales se realizo de forma temprana (antes de 72 horas) y 23 (31,94 %) de forma tardía (después de las 72 horas). RESULTADOS: No se encontraron diferencias en la morbilidad entre los dos grupos observados. Se encontró una mayor incidencia de PASB en mujeres, no hubo complicaciones asociadas al procedimiento y no hubo mortalidad asociada en ninguno de los grupos. DISCUSION: El estudio no muestra que la realización de CPRE tardía influya de forma desfavorable en los pacientes con PASB. Se encontró mayor incidencia de PASB en mujeres y edad media de 61 años. Deben realizarse mas estudios como el presente con un mayor número de pacientes para demostrar que no hay aumento en la morbimortalidad en los pacientes que sean llevados a CPRE después de 72 horas de inicio de los síntomas y poder generar recomendaciones de manejo locales.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La prevalencia de coledocolitiasis es de un 10 a 20%. 10-20% tienen coledocolitiasis gigante, es decir presencia de cálculos mayores de 15 mm, aumentando la morbimortalidad por complicaciones. El objetivo principal fue determinar la frecuencia de coledocolitiasis gigante, la presencia de factores predictores del éxito o fracaso del manejo endoscópico. El éxito en el manejo endoscópico está entre 80 y 90%, un 20% requieren cirugía de exploración biliar. Se realizó la búsqueda de las variables utilizando el instrumento para la recolección de la información. Se realizó un análisis univariado y bivariado de las variables medidas y se utilizo STATA versión 10. Como principal resultado, se encontró que la frecuencia de coledocolitiasis gigante en nuestra población fue del 10%, el éxito del manejo endoscopio fue del 89.23% y el factor predictor mas fuerte para el éxito fue el diámetro del cálculo, siendo mayor para cálculos de menos de 19.09 mm. Como conclusión, en nuestro estudio, la frecuencia de coledocolitiasis gigante es cercana a la conocida en la literatura mundial. El manejo endoscópico en nuestro estudio es el pilar en estos casos, teniendo probabilidad de éxito en el manejo que es igual a la publicada en los estudios mundiales, que existe la probabilidad que el tamaño del cálculo mayor a 19 mm de diámetro indique mayor tasa de fracaso y requerimiento de técnicas endoscópicas avanzadas para su éxito. Se requieren estudios, con mayor número de pacientes para determinar la validez estadística de estos resultados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introducción: El conocimiento actual de la fisiopatología del envejecimiento periorbitario justifica la aplicación de materiales de relleno inyectables, dado que se enfocan en la restauración del volumen perdido en esta zona, convirtiéndose en una excelente alternativa a procedimientos quirúrgicos que remueven el tejido excedente. Sin embargo los efectos y la seguridad de esta naciente tendencia terapéutica aún no se sustentan en una sólida base científica. El objetivo de esta revisión es identificar el material de relleno inyectable más adecuado para el manejo de los defectos volumétricos estéticos de la región periorbitaria. Metodología: Se realizó una búsqueda exhaustiva de los artículos indexados publicados del 1º de enero de 2.000 al 30 de septiembre de 2.013, en diversas bases de datos electrónicas, se seleccionaron catorce publicaciones, se extrajo la información referente a datos demográficos, la intervención, el seguimiento y los desenlaces y se realizó un análisis de 14 estudios que cumplieron los criterios. Resultados: Todos los artículos incluidos poseían un bajo nivel de evidencia y del grado de recomendación. Todos los materiales de relleno se asociaron a altos niveles de satisfacción para el paciente, adecuada mejoría de la apariencia estética y similares efectos colaterales, el ácido hialurónico fue el material de relleno inyectable más utilizado en la región periorbitaria. Discusión: Los materiales de relleno inyectable mejoran los defectos volumétricos estéticos de la región periorbitaria pero es necesaria mayor evidencia para determinar el tipo relleno más apropiado para esta condición.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: Analizar los resultados de 111 pacientes pediátricos sometidos a enucleación o evisceración en la Clínica Barraquer durante 11 años (1990-2000), determinando tipo de corrección realizada y complicaciones asociadas al procedimiento quirúrgico. Métodos: Estudio retrospectivo de las historias clínicas de todos los pacientes menores de 18 años que fueron sometidos a los procedimientos mencionados, obteniendo datos demográficos,diagnóstico, cirugías oftalmológicas asociadas, características de implantes o injertos, seguimiento y complicaciones postoperatorias en todos los pacientes. Resultados: Se realizaron 55 enucleaciones y 56 evisceraciones. Sólo en un caso no se colocó algún implante o injerto. Durante los primeros 4 años del análisis los injertos lipodérmicos correspondían a un 25,45% y los implantes de Nylon a un 72,72% de las correcciones realizadas, mientras que en los últimos 7 años el implante de hidroxiapatita constituyó el 78,57% de los casos intervenidos. En 17 (15,32%) pacientes se observaron complicaciones que requirieron algún tipo de corrección quirúrgica, sin diferencias estadísticamente significativas entre las distintas correcciones utilizadas. Conclusiones: Para la población pediátrica los implantes de hidroxiapatita, además de brindar una excelente reconstrucción de la órbita anoftálmica, mejoran los resultados estéticos y de motilidad. Sin embargo otro tipo de correcciones como los injertos lipodérmicos siguen constituyendo una excelente alternativa en nuestro medio, teniendo en cuenta que sus costos son mucho menores. Aunque se observaron algunas complicaciones con los diferentes tipos de corrección, muy pocas requirieron una nueva intervención quirúrgica. La tasa de complicaciones se incrementa en pacientes de menos edad.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introducción: Las fracturas de fémur en pediatría son una causa de discapacidad por requerir una inmovilización prolongada, convirtiendo su manejo en un reto para el ortopedista. El tratamiento depende de muchos factores, como la edad, el peso, el tipo de fractura y mecanismo de trauma. El estudio evaluará los desenlaces clínicos y radiológicos del paciente pediátrico con fracturas diafisiaria de fémur manejadas quirúrgicamente con clavos elásticos endomedulares. Materiales y métodos: Estudio observacional descriptivo, serie de casos, recolección de información a través de revisión de historias clínicas en pacientes sometidos quirúrgicamente con clavos elásticos. Resultados: Un total de 13 casos; promedio de edad de 8,2±2,86 años; relación hombre mujer es 3: 1. Principal mecanismo de trauma baja energía (9 casos). Con un seguimiento de 12.5±2,82 meses, el postoperatorio evidenció complicaciones menores relacionadas con irritación del punto de entrada del clavo (9 casos). Solo un caso presentó no unión de la fractura. No se documentaron otras complicaciones, existen diferencias estadísticamente significativas en la anteversión femoral del miembro fracturado y el sano (p=0,001) relacionado con problemas rotacionales, igual que la angulación en el plano sagital (p=0,030) sin repercusión para la consolidación ni la marcha. Conclusiones: El análisis de resultados clínicos y radiológicos concuerda con lo descrito en la literatura mundial, los clavos elásticos endomedulares es una técnica reproducible con resultados excelentes y satisfactorios, bajas tasas de complicaciones. Éste estudio presenta limitaciones debido al tamaño de muestra, no podemos hacer recomendaciones definitivas.