958 resultados para least limiting water range
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The excess enthalpy of mixing of DMF-water was measured at 25° C in the 0-1 molar fraction range. The maximum of heat is developed for a 0.33 DMF molar fraction. The excess partial molar and other excess quantities were also calculated for the DMF-water system at 25° C. The results suggest a strong interaction between DMF and water. © 1983.
Resumo:
From the 18O hydrograph separation method, it was found that groundwater contribution is the principal component of the total discharge produced by these two catchment areas. The weighted mean of the 18O concentration in the precipitation, obtained for a four year period, was close to -6.0‰, with a variation in range of +2.3‰ to -16.3‰. For Bufalos stream water the weighted mean of 18O values during the same period (1984-1987) was -6.3‰, with a variation from -2.5‰ to -10.1‰, whereas for Paraiso this mean was -6.4‰, with extreme values of -3.1‰ and -9.8‰. From these values it was found that the amplitude damping (Ariver/Aprecipitation) was 0.41 for the Bufalos watershed and 0.36 for Paraiso. Using the appropriate equation to estimate the mean residence time of water in the subsurface reservoir of the Bufalos and Paraiso watersheds, the results of 4.3 and 5.0 months, respectively, were obtained. -from Authors
Resumo:
The excess enthalpy of mixing of acetone-water was measured at 25°C in the 0-1 molar fraction range. The minimum and the maximum in the H E (X 2) curve occurred at X 2 = 0.18 and X 2 = 0.85, respectively. The excess partial molar and other excess quantities were also calculated for the acetone-water system at 25°C. The results are interpreted in view of the influence of acetone on the structure of water. © 1983.
Resumo:
Low-density seedings of yeast cells of Paracoccidioides brasiliensis give poor growth (as assessed by plating efficiency test) on conventional mycological agar media, and therefore growth-promoting factors for this fungus were sought. Water-extracts of yeast cells of six P. brasiliensis isolates were all considerably effective in promoting the growth of low-density seedings of P. brasiliensis isolates Pb-18 and Hachisuga, but had little effect on isolate Bt-4. Horse serum, at a concentration range of 2-4%, moderately or considerably promoted the growth of these P. brasiliensis isolates. Combinations of the fungus cell extracts with horse serum were highly effective in promoting the growth of all of the fungal isolates. The fungus cell extracts showed siderophore (microbial iron carrier) activity. An iron-chelator, ethylenediaminetetraacetic acid, at a concentration of 100 μM also highly promoted the growth of the fungal isolates in the presence of horse serum, and ferric ion added to culture medium was considerably effective in the growth promotion. These results suggest that deficient utilization of external iron by the fungus cell is one of the growth-limiting processes for low-density seedings of yeast cells of P. brasiliensis on conventional mycological agar media.
Resumo:
The specific heat, thermal conductivity, thermal diffusivity and density of Brazilian orange juice were determined between 0.34 and 0.73 (w/w) water content and with temperatures from 0.5 to 62°C. The experimental data were fitted as functions of temperature and water content and all properties showed a linear dependency with these variables. In the tested range, the water content exhibited a greater influence on the analyzed properties than temperature. © 1998 Elsevier Science Limited. All rights reserved.
Resumo:
Moisture equilibrium data of persimmon skin and pulp were determined using the static gravimetric method. Adsorption and desorption isotherms were obtained in the range of 20-70°C, to water activities (a w) from 0.02 to 0.85. The application of the GAB model to the experimental results, using direct nonlinear regression analysis, provided a good agreement between experimental and calculated values. The net isosteric heat of sorption was estimated from equilibrium sorption data, using the Clausius-Clapeyron equation. Isosteric heats of sorption were found to increase with increasing temperature and could be well adjusted by an exponential relationship. The enthalpy-entropy compensation theory was applied to sorption isotherms and plots of ΔH versus ΔS for skin and pulp provided the isokinetic temperatures, indicating an enthalpy controlled sorption process. © 2000 Elsevier Science B.V.
Resumo:
We report in situ and remote observations proving occasional occurrence of solid particles in the tropical lowest stratosphere, 200km from deep convective events. The particles were found during field campaigns in Southeast Brazil (49.03 W 22.36 S). They occur in the altitude range from 17.5 to 20.8 km, at temperatures up to at least 10 K above the expected frost point temperature. While stability of ice particles at these altitudes is unexpected from a theoretical point of view, it is argued that these observations are indications of tropospheric air masses penetrating into the stratosphere during convective overshoots. It is argued that the intrusion of tropospheric air must have carried a large amount of water with it, which effectively hydrated the lowest stratosphere, and consequently suppressed sublimation. This conclusion is further supported by a separate water vapor mixing ratio profile obtained at the same observation site.
Resumo:
Simulations of overshooting, tropical deep convection using a Cloud Resolving Model with bulk microphysics are presented in order to examine the effect on the water content of the TTL (Tropical Tropopause Layer) and lower stratosphere. This case study is a subproject of the HIBISCUS (Impact of tropical convection on the upper troposphere and lower stratosphere at global scale) campaign, which took place in Bauru, Brazil (22° S, 49° W), from the end of January to early March 2004. Comparisons between 2-D and 3-D simulations suggest that the use of 3-D dynamics is vital in order to capture the mixing between the overshoot and the stratospheric air, which caused evaporation of ice and resulted in an overall moistening of the lower stratosphere. In contrast, a dehydrating effect was predicted by the 2-D simulation due to the extra time, allowed by the lack of mixing, for the ice transported to the region to precipitate out of the overshoot air. Three different strengths of convection are simulated in 3-D by applying successively lower heating rates (used to initiate the convection) in the boundary layer. Moistening is produced in all cases, indicating that convective vigour is not a factor in whether moistening or dehydration is produced by clouds that penetrate the tropopause, since the weakest case only just did so. An estimate of the moistening effect of these clouds on an air parcel traversing a convective region is made based on the domain mean simulated moistening and the frequency of convective events observed by the IPMet (Instituto de Pesquisas Meteorológicas, Universidade Estadual Paulista) radar (S-band type at 2.8 Ghz) to have the same 10 dBZ echo top height as those simulated. These suggest a fairly significant mean moistening of 0.26, 0.13 and 0.05 ppmv in the strongest, medium and weakest cases, respectively, for heights between 16 and 17 km. Since the cold point and WMO (World Meteorological Organization) tropopause in this region lies at ∼ 15.9 km, this is likely to represent direct stratospheric moistening. Much more moistening is predicted for the 15-16 km height range with increases of 0.85-2.8 ppmv predicted. However, it would be required that this air is lofted through the tropopause via the Brewer Dobson circulation in order for it to have a stratospheric effect. Whether this is likely is uncertain and, in addition, the dehydration of air as it passes through the cold trap and the number of times that trajectories sample convective regions needs to be taken into account to gauge the overall stratospheric effect. Nevertheless, the results suggest a potentially significant role for convection in determining the stratospheric water content. Sensitivity tests exploring the impact of increased aerosol numbers in the boundary layer suggest that a corresponding rise in cloud droplet numbers at cloud base would increase the number concentrations of the ice crystals transported to the TTL, which had the effect of reducing the fall speeds of the ice and causing a ∼13% rise in the mean vapour increase in both the 15-16 and 16-17 km height ranges, respectively, when compared to the control case. Increases in the total water were much larger, being 34% and 132% higher for the same height ranges, but it is unclear whether the extra ice will be able to evaporate before precipitating from the region. These results suggest a possible impact of natural and anthropogenic aerosols on how convective clouds affect stratospheric moisture levels.
Resumo:
Includes bibliography
Resumo:
Incluye Bibliografía
Resumo:
This work describes a method to determine Cu at wide range concentrations in a single run without need of further dilutions employing high-resolution continuum source flame atomic absorption spectrometry. Different atomic lines for Cu at 324. 754 nm, 327. 396 nm, 222. 570 nm, 249. 215 nm and 224. 426 nm were evaluated and main figures of merit established. Absorbance measurements at 324. 754 nm, 249. 215 nm and 224. 426 nm allows the determination of Cu in the 0. 07-5. 0 mg L -1, 5. 0-100 mg L -1 and 100-800 mg L -1 concentration intervals respectively with linear correlation coefficients better than 0. 998. Limits of detection were 21 μg L -1, 310 μg L -1 and 1400 μg L -1 for 324. 754 nm, 249. 215 nm and 224. 426 nm, respectively and relative standard deviations (n = 12) were ≤ 2. 7%. The proposed method was applied to water samples spiked with Cu and the results were in agreement at a 95% of confidence level (paired t-test) with those obtained by line-source flame atomic absorption spectrometry.