930 resultados para X-ray computed tomography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

An x-ray photoelectron spectroscopy (XPS) analysis of Nb/Al wedge bilayers, oxidized by both plasma and natural oxidation, is reported. The main goal is to show that the oxidation state¿i.e., O:(oxidize)Al ratio¿, structure and thickness of the surface oxide layer, as well as the thickness of the metallic Al leftover, as functions of the oxidation procedure, can be quantitatively evaluated from the XPS spectra. This is relevant to the detailed characterization of the insulating barriers in (magnetic) tunnel junctions

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report on a patient with Marfan syndrome who presented a Stanford type B dissection of the descending thoracic aorta in late pregnancy. After a cesarean section, the patient presented a severe obstruction of the mesenteric superior artery. An endovascular fenestration was performed (balloon and guidewire based fenestration). Computed tomography (CT) angiography revealed an intussusception 'like' image of the abdominal aortic layers as a consequence of the fenestration procedure. Because of aneurismal progression in the abdominal aorta, surgical repair of the abdominal aorta and intussusception material removal was achieved six weeks later. The patient is currently in good condition. We conclude that the intussusception could be induced by a guidewire. This fenestration procedure is not recommended in patients with structural aortic disorders.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sweet syndrome is a non infectious febrile disease with a neutrophilic infiltrate of dermis. Extracutaneous involvement can occur. We report two cases of Sweet syndrome with cutaneous and pulmonary involvement and give a short review of the literature of pulmonary involvement in Sweet syndrome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two cases of idiopathic sclerochoroidal calcification are reported with follow-up of two and ten years. In addition we have reviewed 102 cases of choroidal osteoma, including six misleading case reports which actually described idiopathic sclerochoroidal calcification and not choroidal osteoma. Clinical manifestation and the angiographic features of idiopathic sclerochoroidal calcification are outlined. The differential diagnosis of intraocular deposition of calcium salts is discussed in detail.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate the diagnostic performance of abdominal radiography in the detection of illegal intracorporeal containers (hereafter, packets), with low-dose computed tomography (CT) as the reference standard. MATERIALS AND METHODS: This study was approved by the institutional ethical review board, with written informed consent. From July 2007 to July 2010, 330 people (296 men, 34 women; mean age, 32 years [range, 18-55 years]) suspected of having ingested drug packets underwent supine abdominal radiography and low-dose CT. The presence or absence of packets at abdominal radiography was reported, with low-dose CT as the reference standard. The density and number of packets (≤ 12 or >12) at low-dose CT were recorded and analyzed to determine whether those variables influence interpretation of results at abdominal radiography. RESULTS: Packets were detected at low-dose CT in 53 (16%) suspects. Sensitivity of abdominal radiography for depiction of packets was 0.77 (41 of 53), and specificity was 0.96 (267 of 277). The packets appeared isoattenuated to the bowel contents at low-dose CT in 16 (30%) of the 53 suspects with positive results. Nineteen (36%) of the 53 suspects with positive low-dose CT results had fewer than 12 packets. Packets that were isoattenuated at low-dose CT and a low number of packets (≤12) were both significantly associated with false-negative results at abdominal radiography (P = .004 and P = .016, respectively). CONCLUSION: Abdominal radiography is mainly limited by low sensitivity when compared with low-dose CT in the screening of people suspected of carrying drug packets. Low-dose CT is an effective imaging alternative to abdominal radiography.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When abdominal imaging reveals the existence of unsuspected adrenal masses, a diagnostic strategy is necessary. We report the case of a woman presenting with pulmonary embolism, in whom abdominal ultrasound revealed voluminous masses in both adrenals without clinical or biological signs of hormone hypersecretion, but with mild primary adrenal failure. From a CT scan-directed needle biopsy of the right adrenal mass and subsequent staging we were able to diagnose a primary bilateral adrenal lymphoma, diffuse large B-cell type (REAL/WHO). On CHOP chemotherapy both adrenal masses decreased dramatically and the patient is in remission 18 months later. Primary adrenal lymphoma is a rare condition, since 65 cases have been reported to date. Histological diagnosis is nevertheless important, in view of the excellent response to specific therapy observed in some cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Our objective is to describe pouchography, CT, and MRI features of the J-shaped pouch, both normal and with pouch-related complications. CONCLUSION: Pouchography is performed before closure of the loop ileostomy to assess the integrity of the ileal pouch and anastomosis. CT and MRI can be performed when postoperative complications, such as small-bowel obstruction, pouchitis, leakage, abscess, intramural hematoma, desmoid tumor, or recurrent Crohn's disease, are suspected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Left recurrent laryngeal nerve palsy usually results from invasion or compression of the nerve caused by diseases localized within the aortopulmonary window. This study reports the case of a 76-yr-old male with vocal cord paralysis due to lymph node involvement by silicosis. This rare entity was identified by video-mediastinoscopy, which revealed a granulomatous and fibrosed recurrent lymph node encasing the nerve. The nerve was dissected and released from scar tissues. Progressive clinical improvement was observed followed by total and durable recovery of the voice after 15 weeks follow-up.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tuberculous spondylitis is rare in economically well-developed countries. MRI is the most sensitive radiologic method of diagnosis. CT-guided fine needle aspiration can be an appropriate method for obtaining samples for culture, with positive cultures in 25 to 89% of cases. However, it can take >6 weeks for specimens to grow, and it is essential to have adequate culture and sensitivity studies for the diagnosis and treatment of mycobacterial diseases. We propose a minimally invasive diagnostic approach that ensures that adequate surgical specimens are obtained prior to initiating treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this article was to review the strategies to control patient dose in adult and pediatric computed tomography (CT), taking into account the change of technology from single-detector row CT to multi-detector row CT. First the relationships between computed tomography dose index, dose length product, and effective dose in adult and pediatric CT are revised, along with the diagnostic reference level concept. Then the effect of image noise as a function of volume computed tomography dose index, reconstructed slice thickness, and the size of the patient are described. Finally, the potential of tube current modulation CT is discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present the result of polar angle resolved x¿ray photoemission spectroscopy on Al(111)/O and cluster calculations of the O(1s) binding energy (BE) for various model situations. In the experimental data two O(1s) peaks are observed, separated by 1.3 eV. The angular behavior (depth¿resolution) could indicate that the lower BE peak is associated with an O atom under the surface, and the higher BE peak with an O atom above the surface. Equally, it could indicate oxygen islands on the surface where the perimeter atoms have a higher O(1s) BE than the interior atoms. The cluster calculations show that the former interpretation cannot be correct, since an O ads below the surface has a higher calculated O(1s) BE than one above. Cluster calculations simulating oxygen islands are, however, consistent with the experimental data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In a patient with Hyper-IgE-syndrome multiple liver abscesses developed in spite of prophylactic treatment with trimethoprim and sulfamethoxazol. Ultrasound confirmed the clinical diagnosis and percutaneous needle aspiration under ultrasonographic guidance and culture of the aspirated pus allowed specific antibiotic treatment by oral chloramphenicol alone without surgical drainage. The isolated Staph.aureus strain was resistant to trimethoprim and sulfamethoxazol.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The O 1s x-ray photoelectron spectroscopy spectrum for Al(111)/O at 300 K shows two components whose behavior as a function of time and variation of detection angle are consistent with either (a) a surface species represented by the higher binding-energy (BE) component and a subsurface species represented by the lower BE component, or (b) small close-packed oxygen islands with the interior atoms represented by the lower BE component and the perimeter atoms by the higher BE component. We have modeled both situations using ab initio Hartree-Fock wave functions for clusters of Al and O atoms. For an O atom in a threefold site, it was found that a below-surface position gave a higher O 1s BE than an above-surface position, incompatible with interpretation (a). This change in the O 1s BE could arise because the bond for O to Al may have a more covalent character when the O is below the surface than when it is above the surface. We present evidence consistent with this view. An O adatom island with all the O atoms in threefold sites gives calculated O 1s BE's which are significantly higher for the perimeter O atoms. Further, the results for an isolated O island without the Al substrate present also give higher BE¿s for the perimeter atoms. Both these results are consistent with interpretation (b). Published scanning-tunneling-microscopy data supports the suggestion that the chemisorbed state consists of small, close-packed islands, whereas the presence of two vibrational modes in high-resolution electron-energy-loss spectroscopy data has been interpreted as representing surface and subsurface oxygen atoms. In light of the present results, we suggest that a vibrational interpretation in terms of interior and perimeter adatoms should be considered.