886 resultados para Resonant Frequency.
Resumo:
Self-sustained time-dependent current oscillations under dc voltage bias have been observed in recent experiments on n-doped semiconductor superlattices with sequential resonant tunneling. The current oscillations are caused by the motion and recycling of the domain wall separating low- and high-electric-field regions of the superlattice, as the analysis of a discrete drift model shows and experimental evidence supports. Numerical simulation shows that different nonlinear dynamical regimes of the domain wall appear when an external microwave signal is superimposed on the dc bias and its driving frequency and driving amplitude vary. On the frequency-amplitude parameter plane, there are regions of entrainment and quasiperiodicity forming Arnold tongues. Chaos is demonstrated to appear at the boundaries of the tongues and in the regions where they overlap. Coexistence of up to four electric-field domains randomly nucleated in space is detected under ac+dc driving.
Resumo:
Spatiotemporal chaos is predicted to occur in n-doped semiconductor superlattices with sequential resonant tunneling as their main charge transport mechanism. Under dc voltage bias, undamped time-dependent oscillations of the current (due to the motion and recycling of electric field domain walls) have been observed in recent experiments. Chaos is the result of forcing this natural oscillation by means of an appropriate external microwave signal.
Resumo:
Tot i que el cacau i la xocolata són una gran font de polifenols, aquests aliments no es troben entre les fonts alimentàries de polifenols més consumides. Algunes dades suggereixen un aport inferior al 10% de polifenols a través d’aquests. Aquest fet podria ser causa de les diferents metodologies i l'enfocament dels qüestionaris de freqüència de consum d'aliments (FFQ) utilitzats en aquests estudis. La majoria de FFQ validats utilitzen una extensa llista d'aliments per a les fruites i verdures, però no distingeixen adequadament les diverses fonts de xocolata i cacau. Aquests fets recolzen la necessitat d'una avaluació del consum de productes de cacau per tal de poder conèixer la ingesta real de cacau, especialment en la població jove, on la xocolata és un aliment consumit freqüentment.
Resumo:
Normaalisti radiovastaanottimet on luokiteltavissa suoriin vastaanottimiin ja superheterodynevastaanottimiin. Jälkimmäistä nimitetään tavallisesti supervastaanottimeksi. Molemman vastaanottimen oleellisiin osiin kuuluu antennin virityspiiri, supervastaanottimelle lisäksi paikallisoskillaattorin virityspiiri, mikä pitää virittää antennipiirin kanssa samanaikaisesti. Pienillä taajuuksilla, taajuudet luokassa kilo-Hertzejä tai pienemmillä, on antennipiirin viritys resonanssipiirin ominaisuuksista johtuen sitä kapeammalla kaistalla ja sitä hitaampaa mitä pienemmällä taajuudella vastaanotto tapahtuu. Lisäksi virityspiiri hyvyysluku Q on vaikea saada sopivaksi, mikäli viritys on muuten käytännöllinen, säädettävä resonanssipiiri. Vaadittaessa kiinteätaajuista viritystä on käytännöllistä hyödyntää sähkömekaanisia osia, siis keraamisia tai kvartsikiteitä. Koska kiteitten ja korkean hyvyysluvun piirin värähtely jatkuu useita värähtelyjaksoja ennen saapuneitten värähtelyjen sammumista, kestää myös kauan aikaa, ennen kuin värähtely piirissä on loppu. Pienitaajuinen resonanssipiiri saavuttaa maksimivirtansa hitaasti, jos hyvyysluku on iso, kun piiri alkaa johtaa resonanssitaajuista virtaa. Tässä työssä pyritään vastaanotinjärjestelyyn ongelmallisen, pientaajuisen virityspiirin käytön välttämiseksi. Toisena tavoitteena on saada aikaan vastaanotto siten, että tietty pienitaajuinen radiotaajuusalue voidaan kokonaisuudessaan vastaanottaa jatkuva-aikaisesti, ilman antennipiirin jatkuvaa virittämistä erillisille taajuuksille. Laaditaan kytkentä, joka mitoitetaan, simuloidaan ja mitataan.
Resumo:
Suomessa sähkönjakeluverkko koostuu pääasiassa 20 kV ja 400 V jännitetasoista. Tällöin sähkö viedään lähelle kuluttajia suuremmalla jännitetasolla ja muunnetaan alhaisemmaksi lähellä asiakkaita. Haittapuolena on se, että haja-asutusalueilla jakelumuuntajien määrä kasvaa suureksi, koska ne täytyy sijoittaa lähelle kuluttajaa. Vaihtoehtona on toteuttaa osa sähkönjakelusta tasajännitteellä, jolloin tehollinen jännite olisi suurempi. Tällöin sähköä voitaisiin siirtää pidempiä matkoja ilman, että asiakaskohtaisia tai muutaman asiakkaan kattavia 20 kV siirtolinjoja tarvitsisi käyttää. Tämä taasen edellyttää asiakaskohtaisien vaihtosuuntaajien käyttöä. Tässä työssä esiteltävällä 1 kVA vaihtosuuntaajalla muodostetaan tasasähköjakeluverkosta saatavasta 750 V tasasähköstä yksivaiheista (230 VRMS, 50 Hz) verkkojännitettä. Laite on suunniteltu toteuttamaan galvaaninen erotus mahdollisimman hyvän hyötysuhteen puitteissa. Vaihtosuuntaaja on toteutettu käyttämällä resonanssikonvertteria, joka vaihtosuuntaa jakelujännitteen korkeataajuiseksi vaihtojännitteeksi. Tämän jälkeen toteutetaan galvaaninen erotus käyttäen suurtaajuusmuuntajaa. Tätä seuraa syklokonvertteri, joka pulssintiheysmodulaatiota soveltaen muodostaa lähtöjännitteen. Tämä suodatetaan lopuksi LC- alipäästösuotimella säröltään standardin mukaiseksi. Laite on jaettu työssä kolmeen osaan, joista jokaisen toiminta on selitetty ja simuloitu itsenäisesti. Lopussa koko järjestelmä on simuloitu yhtenä kokonaisuutena. Hyötysuhteeksi arvioitiin karkeasti 94 % ja lopullisista tuloksista voidaan päätellä, että laitteen toteuttaminen prototyypiksi voisi olla kannattavaa.
Resumo:
The aim of the thesis is to investigate the hybrid LC filter behavior in modern power drives; to analyze the influence of such a du/dt filter on the control system stability. With the implementation of the inverter output RLC filter the motor control becomes more complicated. And during the design process the influence of the filter on the motor should be considered and the filter RLC parameters should be constrained.
Resumo:
This master’s thesis is focused on power supply network disturbances and their effects on the frequency converter – one of the components of modern process crane electrical system. The most critical disturbance types, their causes and the effect they bring to crane electrical system was determined in this work. Variety of protective devices used for mitigation of disturbances is investigated. Device protection solutions for the frequency converter used in crane applications are presented. Analyses of the power supply requirements for frequency converter and various components of crane electrical system were carried out and as a result the crane power supply requirements list that guarantees normal crane operation was built. This list is to be included in crane projects for troubleshooting purposes in order to determine potentially dangerous network.
Resumo:
The increasing power demand and emerging applications drive the design of electrical power converters into modularization. Despite the wide use of modularized power stage structures, the control schemes that are used are often traditional, in other words, centralized. The flexibility and re-usability of these controllers are typically poor. With a dedicated distributed control scheme, the flexibility and re-usability of the system parts, building blocks, can be increased. Only a few distributed control schemes have been introduced for this purpose, but their breakthrough has not yet taken place. A demand for the further development offlexible control schemes for building-block-based applications clearly exists. The control topology, communication, synchronization, and functionality allocationaspects of building-block-based converters are studied in this doctoral thesis. A distributed control scheme that can be easily adapted to building-block-based power converter designs is developed. The example applications are a parallel and series connection of building blocks. The building block that is used in the implementations of both the applications is a commercial off-the-shelf two-level three-phase frequency converter with a custom-designed controller card. The major challenge with the parallel connection of power stages is the synchronization of the building blocks. The effect of synchronization accuracy on the system performance is studied. The functionality allocation and control scheme design are challenging in the seriesconnected multilevel converters, mainly because of the large number of modules. Various multilevel modulation schemes are analyzed with respect to the implementation, and this information is used to develop a flexible control scheme for modular multilevel inverters.
Centralized Motion Control of a Linear Tooth Belt Drive: Analysis of the Performance and Limitations
Resumo:
A centralized robust position control for an electrical driven tooth belt drive is designed in this doctoral thesis. Both a cascaded control structure and a PID based position controller are discussed. The performance and the limitations of the system are analyzed and design principles for the mechanical structure and the control design are given. These design principles are also suitable for most of the motion control applications, where mechanical resonance frequencies and control loop delays are present. One of the major challenges in the design of a controller for machinery applications is that the values of the parameters in the system model (parameter uncertainty) or the system model it self (non-parametric uncertainty) are seldom known accurately in advance. In this thesis a systematic analysis of the parameter uncertainty of the linear tooth beltdrive model is presented and the effect of the variation of a single parameter on the performance of the total system is shown. The total variation of the model parameters is taken into account in the control design phase using a Quantitative Feedback Theory (QFT). The thesis also introduces a new method to analyze reference feedforward controllers applying the QFT. The performance of the designed controllers is verified by experimentalmeasurements. The measurements confirm the control design principles that are given in this thesis.
Resumo:
The purpose of this study was to evaluate the efficiency of integrated managements on white mold control on common bean. Initially, in vitro testing was made to assess the antagonism of 11 Trichoderma isolates against Sclerotinia sclerotiorum and to investigate fungicides (fluazinam and procymidone) inhibitory effects on those fungi. In two field experiments the following combinations were tested: irrigation frequencies (seven or 14 days), plant densities (six or 12 plants per meter), and three disease controls (untreated control, fungicide or Trichoderma spp.). In a third experiment plant densities were replaced by grass mulching treatments (with or without mulching). Fluazinam was applied at 45 and 55 days after emergence (DAE). The antagonists T. harzianum (experiments 1 and 3) and T. stromatica (experiment 2) were applied through sprinkler irrigation at 10 and 25 DAE, respectively. Most of the Trichoderma spp. were effective against the pathogen in vitro. Fluazinam was more toxic than procymidone to both the pathogen and the antagonist. Fungicide applications increased yield between 32 % and 41 %. In field one application of Trichoderma spp. did not reduce disease intensity and did not increase yield. The reduction from 12 to six plants per meter did not decrease yield, and disease severity diminished in one of the two experiments. It is concluded that of the strategies for white mold control just reduction of plant density and applications of fungicide were efficient.
Resumo:
Centrifugal pumps are widely used in industrial and municipal applications, and they are an important end-use application of electric energy. However, in many cases centrifugal pumps operate with a significantly lower energy efficiency than they actually could, which typically has an increasing effect on the pump energy consumption and the resulting energy costs. Typical reasons for this are the incorrect dimensioning of the pumping system components and inefficiency of the applied pump control method. Besides the increase in energy costs, an inefficient operation may increase the risk of a pump failure and thereby the maintenance costs. In the worst case, a pump failure may lead to a process shutdown accruing additional costs. Nowadays, centrifugal pumps are often controlled by adjusting their rotational speed, which affects the resulting flow rate and output pressure of the pumped fluid. Typically, the speed control is realised with a frequency converter that allows the control of the rotational speed of an induction motor. Since a frequency converter can estimate the motor rotational speed and shaft torque without external measurement sensors on the motor shaft, it also allows the development and use of sensorless methods for the estimation of the pump operation. Still today, the monitoring of pump operation is based on additional measurements and visual check-ups, which may not be applicable to determine the energy efficiency of the pump operation. This doctoral thesis concentrates on the methods that allow the use of a frequency converter as a monitoring and analysis device for a centrifugal pump. Firstly, the determination of energy-efficiency- and reliability-based limits for the recommendable operating region of a variable-speed-driven centrifugal pump is discussed with a case study for the laboratory pumping system. Then, three model-based estimation methods for the pump operating location are studied, and their accuracy is determined by laboratory tests. In addition, a novel method to detect the occurrence of cavitation or flow recirculation in a centrifugal pump by a frequency converter is introduced. Its sensitivity compared with known cavitation detection methods is evaluated, and its applicability is verified by laboratory measurements for three different pumps and by using two different frequency converters. The main focus of this thesis is on the radial flow end-suction centrifugal pumps, but the studied methods can also be feasible with mixed and axial flow centrifugal pumps, if allowed by their characteristics.
Resumo:
Suomessa sähkönjakeluverkon pääasialliset jännitetasot ovat 20 kV ja 400 V. 20 kV jännitetasolla sähkö viedään lähelle kuluttajia ja muunnetaan pienemmäksi lähellä asiakkaita. Haittapuolena on se, että 20 kV avojohtosähkönsiirtoverkko on hyvin vika-altis ja usein yhden haaran vikaantuessa monta muutakin jää ilman sähköä. Lisäksi hintavien ja suurien jakelumuuntajien määrä on suuri. Vaihtoehtona on toteuttaa osa sähkönjakelusta tasajännitteellä, jolloin tehollinen pienjännite olisi 400 V:a suurempi. Tällöin sähköä voitaisiin siirtää pidempiä matkoja ilman, että asiakaskohtaisia tai muutaman asiakkaan kattavia 20 kV siirtolinjoja tarvitsisi käyttää. Tämä edellyttää vaihtosuuntauksen toteuttamista kuluttajan päässä. Tässä työssä esiteltävällä 1 kVA:n tehoisella vaihtosuuntaajalla muodostetaan tasasähköjakeluverkosta saatavasta 750 V tasasähköstä yksivaiheista (230 VRMS, 50 Hz) verkkojännitettä. Laite on suunniteltu toteuttamaan galvaaninen erotus mahdollisimman hyvällä hyötysuhteella. Suurtaajuusmuuntajan mitoitus mahdollisimman hyvälle hyötysuhteelle on haastava tehtävä, koska vaatimuksia sille asettavat sekä syöttävä resonanssikonvertteri että syötettävä syklokonvertteri. Mitoituksessa on pyrittävä löytämään mahdollisimman hyvä hyötysuhde kustannusten ja toteutettavuuden suhteen.
Resumo:
Resonance energy transfer (RET) is a non-radiative transfer of the excitation energy from the initially excited luminescent donor to an acceptor. The requirements for the resonance energy transfer are: i) the spectral overlap between the donor emission spectrum and the acceptor absorption spectrum, ii) the close proximity of the donor and the acceptor, and iii) the suitable relative orientations of the donor emission and the acceptor absorption transition dipoles. As a result of the RET process the donor luminescence intensity and the donor lifetime are decreased. If the acceptor is luminescent, a sensitized acceptor emission appears. The rate of RET depends strongly on the donor–acceptor distance (r) and is inversely proportional to r6. The distance dependence of RET is utilized in binding assays. The proximity requirement and the selective detection of the RET-modified emission signal allow homogeneous separation free assays. The term lanthanide-based RET is used when luminescent lanthanide compounds are used as donors. The long luminescence lifetimes, the large Stokes’ shifts and the intense, sharply-spiked emission spectra of the lanthanide donors offer advantages over the conventional organic donor molecules. Both the organic lanthanide chelates and the inorganic up-converting phosphor (UCP) particles have been used as donor labels in the RET based binding assays. In the present work lanthanide luminescence and lanthanide-based resonance energy transfer phenomena were studied. Luminescence lifetime measurements had an essential role in the research. Modular frequency-domain and time-domain luminometers were assembled and used successfully in the lifetime measurements. The frequency-domain luminometer operated in the low frequency domain ( 100 kHz) and utilized a novel dual-phase lock-in detection of the luminescence. One of the studied phenomena was the recently discovered non-overlapping fluorescence resonance energy transfer (nFRET). The studied properties were the distance and temperature dependences of nFRET. The distance dependence was found to deviate from the Förster theory and a clear temperature dependence was observed whereas conventional RET was completely independent of the temperature. Based on the experimental results two thermally activated mechanisms were proposed for the nFRET process. The work with the UCP particles involved the measurement of the luminescence properties of the UCP particles synthesized in our laboratory. The goal of the UCP particle research is to develop UCP donor labels for binding assays. In the present work the effect of the dopant concentrations and the core–shell structure on the total up-conversion luminescence intensity, the red–green emission ratio, and the luminescence lifetime was studied. Also the non-radiative nature of the energy transfer from the UCP particle donors to organic acceptors was demonstrated for the first time in aqueous environment and with a controlled donor–acceptor distance.
Resumo:
The intensity-duration-frequency occurrence ratio (IDF) is a tool commonly used for precipitation-runoff data transformation, which is established from observations of intense precipitations over a period sufficiently long as to allow the occurrence of extremes at the observation site. This study focused on verifying the existence or absence of new data, in terms of IDF ratio, by using partial duration records produced from data on maximum daily disaggregated rainfall for pre determined durations. The partial duration records considered a base value of 55 mm, totaling 279 values. After the rainfall series were established, their independence and seasonality were assessed. Using the Student's t-test statistics, it was established that no new data, as IDF ratio, emerged from the analysis of the partial duration series with the recommended base value of precipitation, as compared to the historical records.