835 resultados para REDUCING SUGARS
Resumo:
Human Immunodeficiency Virus (HIV) is a retrovirus that can result in rare opportunistic infections occurring in humans. The onset of these infections is known as Acquired Immune Deficiency Syndrome (AIDS). Sexual transmission is responsible for the majority of infections 1, resulting in transmission of HIV due to infected semen or vaginal and cervical secretions containing infected lymphocytes. HIV microbicides are formulations of chemical or biological agents that can be applied to the vagina or rectum with the intention of reducing the acquisition of HIV. Tenofovir is an NRTI that is phosphorylated by adenylate kinase to tenofovir diphosphate, which in turn competes with deoxyadeosine 5’-triphosphate for incorporation into newly synthesized HIV DNA. Once incorporated, tenofovir diphosphate results in chain termination, thus inhibiting viral replication. Tenofovir has been formulated into a range of vaginal formulations, such as rings, tablets gels and films. It has been shown to safe and effective in numerous animal models, while demonstrating safety and acceptability in numerous human trials. The most encouraging results came from the CAPRISA 004 clinical trial which demonstrated that a 1% Tenofovir vaginal gel reduced HIV infection by approximately 39%.
Resumo:
The water and sewerage sectors' combined emissions account for just over 1% of total UK emissions, while household water heating accounts for a further 5%. Energy use, particularly electricity, is the largest source of emissions in the sector. Water efficiency measures should therefore result in reduced emissions from a lower demand for water and wastewater treatment and pumping, as well as from decreased domestic water heating. Northern Ireland Water (NI Water) is actively pursuing measures to reduce its carbon footprint. This paper investigated the carbon impacts of implementing a household water efficiency programme in Northern Ireland. Assuming water savings of 59.6 L/prop/day and 15% uptake among households, carbon savings of 0.6% of NI Water's current net operational emissions are achievable from reduced treatment and pumping. Adding the carbon savings from reduced household water heating gives savings equivalent to 6.2% of current net operational emissions. Cost savings to NI Water are estimated as 300,000 per year. The cost of the water efficiency devices is approximately 1.6 million, but may be higher depending on the number of devices distributed relative to the number installed. This paper has shown clear carbon benefits to water efficiency, but further research is needed to examine social and cost impacts. © IWA Publishing 2013.
Resumo:
Background: This is an update of a review last published in Issue 5, 2010, of The Cochrane Library. Reducing weaning time is desirable in minimizing potential complications from mechanical ventilation. Standardized weaning protocols are purported to reduce time spent on mechanical ventilation. However, evidence supporting their use in clinical practice is inconsistent. Objectives: The first objective of this review was to compare the total duration of mechanical ventilation of critically ill adults who were weaned using protocols versus usual (non-protocolized) practice.The second objective was to ascertain differences between protocolized and non-protocolized weaning in outcomes measuring weaning duration, harm (adverse events) and resource use (intensive care unit (ICU) and hospital length of stay, cost).The third objective was to explore, using subgroup analyses, variations in outcomes by type of ICU, type of protocol and approach to delivering the protocol (professional-led or computer-driven). Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library Issue 1, 2014), MEDLINE (1950 to January 2014), EMBASE (1988 to January 2014), CINAHL (1937 to January 2014), LILACS (1982 to January 2014), ISI Web of Science and ISI Conference Proceedings (1970 to February 2014), and reference lists of articles. We did not apply language restrictions. The original search was performed in January 2010 and updated in January 2014.Selection criteriaWe included randomized controlled trials (RCTs) and quasi-RCTs of protocolized weaning versus non-protocolized weaning from mechanical ventilation in critically ill adults. Data collection and analysis: Two authors independently assessed trial quality and extracted data. We performed a priori subgroup and sensitivity analyses. We contacted study authors for additional information. Main results: We included 17 trials (with 2434 patients) in this updated review. The original review included 11 trials. The total geometric mean duration of mechanical ventilation in the protocolized weaning group was on average reduced by 26% compared with the usual care group (N = 14 trials, 95% confidence interval (CI) 13% to 37%, P = 0.0002). Reductions were most likely to occur in medical, surgical and mixed ICUs, but not in neurosurgical ICUs. Weaning duration was reduced by 70% (N = 8 trials, 95% CI 27% to 88%, P = 0.009); and ICU length of stay by 11% (N = 9 trials, 95% CI 3% to 19%, P = 0.01). There was significant heterogeneity among studies for total duration of mechanical ventilation (I2 = 67%, P < 0.0001) and weaning duration (I2 = 97%, P < 0.00001), which could not be explained by subgroup analyses based on type of unit or type of approach. Authors' conclusions: There is evidence of reduced duration of mechanical ventilation, weaning duration and ICU length of stay with use of standardized weaning protocols. Reductions are most likely to occur in medical, surgical and mixed ICUs, but not in neurosurgical ICUs. However, significant heterogeneity among studies indicates caution in generalizing results. Some study authors suggest that organizational context may influence outcomes, however these factors were not considered in all included studies and could not be evaluated. Future trials should consider an evaluation of the process of intervention delivery to distinguish between intervention and implementation effects. There is an important need for further development and research in the neurosurgical population.
Resumo:
IntroductionAutomated weaning systems may improve adaptation of mechanical support for a patient’s ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. Our objective was to compare mechanical ventilator weaning duration for critically ill adults and children when managed with automated systems versus non-automated strategies. Secondary objectives were to determine differences in duration of ventilation, intensive care unit (ICU) and hospital length of stay (LOS), mortality, and adverse events.MethodsElectronic databases were searched to 30 September 2013 without language restrictions. We also searched conference proceedings; trial registration websites; and article reference lists. Two authors independently extracted data and assessed risk of bias. We combined data using random-effects modelling.ResultsWe identified 21 eligible trials totalling 1,676 participants. Pooled data from 16 trials indicated that automated systems reduced the geometric mean weaning duration by 30% (95% confidence interval (CI) 13% to 45%), with substantial heterogeneity (I2 = 87%, P <0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not with surgical populations or using other systems. Automated systems reduced ventilation duration with no heterogeneity (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of effect on mortality, hospital LOS, reintubation, self-extubation and non-invasive ventilation following extubation. Automated systems reduced prolonged mechanical ventilation and tracheostomy. Overall quality of evidence was high.ConclusionsAutomated systems may reduce weaning and ventilation duration and ICU stay. Due to substantial trial heterogeneity an adequately powered, high quality, multi-centre randomized controlled trial is needed.
Resumo:
Background Automated closed loop systems may improve adaptation of mechanical support for a patient's ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. This review was originally published in 2013 with an update published in 2014. Objectives The primary objective for this review was to compare the total duration of weaning from mechanical ventilation, defined as the time from study randomization to successful extubation (as defined by study authors), for critically ill ventilated patients managed with an automated weaning system versus no automated weaning system (usual care). Secondary objectives for this review were to determine differences in the duration of ventilation, intensive care unit (ICU) and hospital lengths of stay (LOS), mortality, and adverse events related to early or delayed extubation with the use of automated weaning systems compared to weaning in the absence of an automated weaning system. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 8); MEDLINE (OvidSP) (1948 to September 2013); EMBASE (OvidSP) (1980 to September 2013); CINAHL (EBSCOhost) (1982 to September 2013); and the Latin American and Caribbean Health Sciences Literature (LILACS). Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles. The original search was run in August 2011, with database auto-alerts up to August 2012. Selection criteria We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an ICU. Data collection and analysis Two authors independently extracted study data and assessed risk of bias. We combined data in forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria. Main results We included 21 trials (19 adult, two paediatric) totaling 1676 participants (1628 adults, 48 children) in this updated review. Pooled data from 16 eligible trials reporting weaning duration indicated that automated closed loop systems reduced the geometric mean duration of weaning by 30% (95% confidence interval (CI) 13% to 45%), however heterogeneity was substantial (I2 = 87%, P < 0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of an effect on mortality rates, hospital LOS, reintubation rates, self-extubation and use of non-invasive ventilation following extubation. Prolonged mechanical ventilation > 21 days and tracheostomy were reduced in favour of automated systems (relative risk (RR) 0.51, 95% CI 0.27 to 0.95 and RR 0.67, 95% CI 0.50 to 0.90 respectively). Overall the quality of the evidence was high with the majority of trials rated as low risk. Authors' conclusions Automated closed loop systems may result in reduced duration of weaning, ventilation and ICU stay. Reductions are more likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.
Resumo:
Social work in the United Kingdom remains embroiled in concerns about child protection error. The serious injury or death of vulnerable children continues to evince much consternation in the public and private spheres. Governmental responses to these concerns invariably draw on technocratic solutions involving more procedures, case management systems, information technology and bureaucratic regulation. Such solutions flow from an implicit use of instrumental rationality based on a ‘means-end’ logic. While bringing an important perspective to the problem of child protection error, instrumental rationality has been overused limiting discretion and other modes of rational inquiry. This paper argues that the social work profession should apply an enlarged form of rationality comprising not only the instrumental-rational mode but also the critical-rational, affective-rational and communicative-rational forms. It is suggested that this combined, conceptual arsenal of rational inquiry leads to a gestalt which has been termed the holistic-rational perspective. It is also argued that embracing a more rounded perspective such as this might offer greater opportunities for reducing child protection error.
Resumo:
The advancement of telemetry control for the water industry has increased the difficulty of 14 managing large volumes of nuisance alarms (i.e. alarms that do not require a response). The aim 15 of this study was to identify and reduce the number of nuisance alarms that occur for Northern 16 Ireland (NI) Water by carrying-out alarm duration analysis to determine the appropriate length of 17 persistence (an advanced alarm management tool) that could be applied. All data was extracted 18 from TelemWeb (NI Water’s telemetry monitoring system) and analysed in Excel. Over a 6 19 week period, an average of 40,000 alarms occurred per week. The alarm duration analysis, which 20 has never been implemented before by NI Water, found that an average of 57% of NI Water 21 alarms had a duration of <5 minutes. Applying 5 minute persistence; therefore, could prevent an 22 average 26,816 nuisance alarms per week. Most of these alarms were from wastewater assets.
Resumo:
In this paper we explore ways to address the issue of dataset bias in person re-identification by using data augmentation to increase the variability of the available datasets, and we introduce a novel data augmentation method for re-identification based on changing the image background. We show that use of data augmentation can improve the cross-dataset generalisation of convolutional network based re-identification systems, and that changing the image background yields further improvements.
Resumo:
The assimilation of discrete higher fidelity data points with model predictions can be used to achieve a reduction in the uncertainty of the model input parameters which generate accurate predictions. The problem investigated here involves the prediction of limit-cycle oscillations using a High-Dimensional Harmonic Balance method (HDHB). The efficiency of the HDHB method is exploited to enable calibration of structural input parameters using a Bayesian inference technique. Markov-chain Monte Carlo is employed to sample the posterior distributions. Parameter estimation is carried out on both a pitch/plunge aerofoil and Goland wing configuration. In both cases significant refinement was achieved in the distribution of possible structural parameters allowing better predictions of their
true deterministic values.
Resumo:
The objective of this study was to evaluate the impact of restricting high-risk antibiotics on methicillin-resistant Staphylococcus aureus (MRSA) incidence rates in a hospital setting. A secondary objective was to assess the impact of reducing fluoroquinolone use in the primary-care setting on MRSA incidence in the community. This was an interventional, retrospective, ecological investigation in both hospital and community (January 2006 to June 2010). Segmented regression analysis of interrupted time-series was employed to evaluate the intervention. The restriction of high-risk antibiotics was associated with a significant change in hospital MRSA incidence trend (coefficient=-0·00561, P=0·0057). Analysis showed that the intervention relating to reducing fluoroquinolone use in the community was associated with a significant trend change in MRSA incidence in community (coefficient=-0·00004, P=0·0299). The reduction in high-risk antibiotic use and fluoroquinolone use contributed to both a reduction in incidence rates of MRSA in hospital and community (primary-care) settings.