975 resultados para Desorption


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This investigation focused on the development, test and validation of methodologies for mercury fractionation and speciation in soil and sediment. After an exhaustive review of the literature, several methods were chosen and tested in well characterised soil and sediment samples. Sequential extraction procedures that divide mercury fractions according to their mobility and potential availability in the environment were investigated. The efficiency of different solvents for fractionation of mercury was evaluated, as well as the adequacy of different analytical instruments for quantification of mercury in the extracts. Kinetic experiments to establish the equilibrium time for mercury release from soil or sediment were also performed. It was found that in the studied areas, only a very small percentage of mercury is present as mobile species and that mobility is associated to higher aluminium and manganese contents, and that high contents of organic matter and sulfur result in mercury tightly bound to the matrix. Sandy soils tend to release mercury faster that clayey soils, and therefore, texture of soil or sediment has a strong influence on the mobility of mercury. It was also understood that analytical techniques for quantification of mercury need to be further developed, with lower quantification limits, particularly for mercury quantification of less concentrated fractions: water-soluble e exchangeable. Although the results provided a better understanding of the distribution of mercury in the sample, the complexity of the procedure limits its applicability and robustness. A proficiency-testing scheme targeting total mercury determination in soil, sediment, fish and human hair was organised in order to evaluate the consistency of results obtained by different laboratories, applying their routine methods to the same test samples. Additionally, single extractions by 1 mol L-1 ammonium acetate solution, 0.1 mol L-1 HCl and 0.1 mol L-1 CaCl2, as well as extraction of the organometallic fraction were proposed for soil; the last was also suggested for sediment and fish. This study was important to update the knowledge on analytical techniques that are being used for mercury quantification, the associated problems and sources of error, and to improve and standardize mercury extraction techniques, as well as to implement effective strategies for quality control in mercury determination. A different, “non chemical-like” method for mercury species identification was developed, optimised and validated, based on the thermo-desorption of the different mercury species. Compared to conventional extraction procedures, this method has advantages: it requires little to no sample treatment; a complete identification of species present is obtained in less than two hours; mercury losses are almost neglectable; can be considered “clean”, as no residues are produced; the worldwide comparison of results obtained is easier and reliable, an important step towards the validation of the method. Therefore, the main deliverables of this PhD thesis are an improved knowledge on analytical procedures for identification and quantification of mercury species in soils and sediments, as well as a better understanding of the factors controlling the behaviour of mercury in these matrices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The paper presents the results of a laboratory investigation on the hygric properties of five hemp insulation materials commercially available in the UK. The hemp fibre content varies between 30-95% in the total fibre content of the insulation materials examined. The adsorption-desorption isotherm, moisture buffer value, vapour diffusion resistance factor and water absorption coefficient were determined for the insulation materials investigated. The results showed that the hygric properties of the hemp insulation materials could vary widely depending on the constituents and fibrous structure. The considerable differences noted in the hygric properties of the insulation materials examined could potentially influence their hygrothermal performance as part of a building thermal envelope.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Moisture and heat management properties of Hemp and Stone Wool insulations were studied by mounting them between a hot and a cold climate chamber. Both insulations were exposed to identical hygrothermal boundary conditions. Quasi steady state and dynamic tests were carried out at a range of relative humidity exposures. The likelihood of interstitial condensation was assessed and equivalent thermal conductivity values of the insulations were determined. The adsorption-desorption isotherms of the insulations were also determined in a dynamic vapour sorption (DVS) instrument. It was observed that the likelihood of condensation was higher in Stone Wool insulation than in Hemp insulation. Hemp insulation performed better in managing moisture due to its high hygric inertia and water absorption capacity. It was observed that the equivalent thermal conductivity of Stone Wool insulation was dependent on enthalpy flow and phase change of moisture. The equivalent thermal conductivity of Hemp insulation was close to its declared thermal conductivity in dynamic conditions when high relative humidity exposures were transient. In quasi steady state boundary conditions, when the insulation was allowed to reach the equilibrium moisture content at ranges of relative humidity, there was a moisture dependent increase of thermal conductivity in Hemp insulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de doutoramento, Química (Química Analítica), Universidade de Lisboa, Faculdade de Ciências, 2014

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trihalomethanes (THMs) are widely referred and studied as disinfection by-products (DBPs). The THMs that are most commonly detected are chloroform (TCM), bromodichloromethane (BDCM), chlorodibromomethane (CDBM), and bromoform (TBM). Several studies regarding the determination of THMs in swimming pool water and air samples have been published. This paper reviews the most recent work in this field, with a special focus on water and air sampling, sample preparation and analytical determination methods. An experimental study has been developed in order to optimize the headspace solid-phasemicroextraction (HS-SPME) conditions of TCM, BDCM, CDBM and TBM from water samples using a 23 factorial design. An extraction temperature of 45 °C, for 25min, and a desorption time of 5 min were found to be the best conditions. Analysis was performed by gas chromatography with an electron capture detector (GC-ECD). The method was successfully applied to a set of 27 swimming pool water samples collected in the Oporto area (Portugal). TCM was the only THM detected with levels between 4.5 and 406.5 μg L−1. Four of the samples exceeded the guideline value for total THMs in swimming pool water (100 μgL−1) indicated by the Portuguese Health Authority.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transthyretin amyloidosis is a conformational pathology characterized by the extracellular formation of amyloid deposits and the progressive impairment of the peripheral nervous system. Point mutations in this tetrameric plasma protein decrease its stability and are linked to disease onset and progression. Since non-mutated transthyretin also forms amyloid in systemic senile amyloidosis and some mutation bearers are asymptomatic throughout their lives, non-genetic factors must also be involved in transthyretin amyloidosis. We discovered, using a differential proteomics approach, that extracellular chaperones such as fibrinogen, clusterin, haptoglobin, alpha-1-anti-trypsin and 2-macroglobulin are overrepresented in transthyretin amyloidosis. Our data shows that a complex network of extracellular chaperones are over represented in human plasma and we speculate that they act synergistically to cope with amyloid prone proteins. Proteostasis may thus be as important as point mutations in transthyretin amyloidosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die Differenzierung von Tinten erweist sich oft als wichtig in der Echtheitsprüfung von Dokumenten. Sie wird üblicherweise durch optische Vergleiche und Dünnschicht Chromatographie durchgeführt (TLC). Laser Desorption Ionisation Massenspektrometrie (LDI-MS) ist auch als nützlich gefunden worden und besonders leistungsfähig um Farbstoffe aus Kugelschreibertinte zu analysieren. Diese analytische Methode ist mit Hochleistungs Dünnschichtchromatografie TLC (HPTLC) verglichen worden, mit dem Ziel deren Tinten-Differenzierungskapazität zu testen. Tinteneinträge von 31 blauen Kugelschreibern sind analysiert worden und gemäß deren Farbstoffzusammensetzung klassifiziert worden. Typische Farbstoffe sind durch beide Methoden identifiziert worden und mehrere sind in vielen Tinten-Zusammensetzungen gefunden worden. LDI-MS ist leistungsfähiger als HPTLC um Tinten zu differenzieren, weil es Informationen über Farbstoffstrukturen (Molekular Gewicht) enthält und eine präzise relative Quantifizierung (Signalfläche) erlaubt. Dazu ist für LDI-MS Proben die Vorbereitung minimal und die Analysezeit kurz im Vergleich zu HPTLC mehr komplexen Schritte, wie Extraktionen, Spots Applikationen und Lösungsmittelelution. Allerdings sind mit LDI-MS zwei Analysen nötig um kationische und anionische Farbstoffe zu analysieren, während mit HPTLC nur eine Analyse nötig ist.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study investigated promoter hypermethylation of TP53 regulatory pathways providing a potential link between epigenetic changes and mitochondrial DNA (mtDNA) alterations in breast cancer patients lacking a TP53 mutation. The possibility of using the cancer-specific alterations in serum samples as a blood-based test was also explored. Triple-matched samples (cancerous tissues, matched adjacent normal tissues and serum samples) from breast cancer patients were screened for TP53 mutations, and the promoter methylation profile of P14(ARF), MDM2, TP53 and PTEN genes was analyzed as well as mtDNA alterations, including D-loop mutations and mtDNA content. In the studied cohort, no mutation was found in TP53 (DNA-binding domain). Comparison of P14(ARF) and PTEN methylation patterns showed significant hypermethylation levels in tumor tissues (P < 0.05 and <0.01, respectively) whereas the TP53 tumor suppressor gene was not hypermethylated (P < 0.511). The proportion of PTEN methylation was significantly higher in serum than in the normal tissues and it has a significant correlation to tumor tissues (P < 0.05). mtDNA analysis revealed 36.36% somatic and 90.91% germline mutations in the D-loop region and also significant mtDNA depletion in tumor tissues (P < 0.01). In addition, the mtDNA content in matched serum was significantly lower than in the normal tissues (P < 0.05). These data can provide an insight into the management of a therapeutic approach based on the reversal of epigenetic silencing of the crucial genes involved in regulatory pathways of the tumor suppressor TP53. Additionally, release of significant aberrant methylated PTEN in matched serum samples might represent a promising biomarker for breast cancer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An impaired glutathione (GSH) synthesis was observed in several multifactorial diseases, including schizophrenia and myocardial infarction. Genetic studies revealed an association between schizophrenia and a GAG trinucleotide repeat (TNR) polymorphism in the catalytic subunit (GCLC) of the glutamate cysteine ligase (GCL). Disease-associated genotypes of this polymorphism correlated with a decrease in GCLC protein expression, GCL activity and GSH content. To clarify consequences of a decreased GCL activity at the proteome level, three schizophrenia patients and three controls have been selected based on the GCLC GAG TNR polymorphism. Fibroblast cultures were obtained by skin biopsy and were challenged with tert-butylhydroquinone (t-BHQ), a substance known to induce oxidative stress. Proteome changes were analyzed by two dimensional gel electrophoresis (2-DE) and results revealed 10 spots that were upregulated in patients following t-BHQ treatment, but not in controls. Nine corresponding proteins could be identified by MALDI mass spectrometry and these proteins are involved in various cellular functions, including energy metabolism, oxidative stress response, and cytoskeletal reorganization. In conclusion, skin fibroblasts of subjects with an impaired GSH synthesis showed an altered proteome reaction in response to oxidative stress. Furthermore, the study corroborates the use of fibroblasts as an additional mean to study vulnerability factors of psychiatric diseases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Carbapenemases should be accurately and rapidly detected, given their possible epidemiological spread and their impact on treatment options. Here, we developed a simple, easy and rapid matrix-assisted laser desorption ionization-time of flight (MALDI-TOF)-based assay to detect carbapenemases and compared this innovative test with four other diagnostic approaches on 47 clinical isolates. Tandem mass spectrometry (MS-MS) was also used to determine accurately the amount of antibiotic present in the supernatant after 1 h of incubation and both MALDI-TOF and MS-MS approaches exhibited a 100% sensitivity and a 100% specificity. By comparison, molecular genetic techniques (Check-MDR Carba PCR and Check-MDR CT103 microarray) showed a 90.5% sensitivity and a 100% specificity, as two strains of Aeromonas were not detected because their chromosomal carbapenemase is not targeted by probes used in both kits. Altogether, this innovative MALDI-TOF-based approach that uses a stable 10-μg disk of ertapenem was highly efficient in detecting carbapenemase, with a sensitivity higher than that of PCR and microarray.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An analytical model for bacterial accumulation in a discrete fractllre has been developed. The transport and accumlllation processes incorporate into the model include advection, dispersion, rate-limited adsorption, rate-limited desorption, irreversible adsorption, attachment, detachment, growth and first order decay botl1 in sorbed and aqueous phases. An analytical solution in Laplace space is derived and nlln1erically inverted. The model is implemented in the code BIOFRAC vvhich is written in Fortran 99. The model is derived for two phases, Phase I, where adsorption-desorption are dominant, and Phase II, where attachment-detachment are dominant. Phase I ends yvhen enollgh bacteria to fully cover the substratllm have accllillulated. The model for Phase I vvas verified by comparing to the Ogata-Banks solution and the model for Phase II was verified by comparing to a nonHomogenous version of the Ogata-Banks solution. After verification, a sensitiv"ity analysis on the inpllt parameters was performed. The sensitivity analysis was condllcted by varying one inpllt parameter vvhile all others were fixed and observing the impact on the shape of the clirve describing bacterial concentration verSllS time. Increasing fracture apertllre allovvs more transport and thus more accllffilliation, "Vvhich diminishes the dllration of Phase I. The larger the bacteria size, the faster the sllbstratum will be covered. Increasing adsorption rate, was observed to increase the dllration of Phase I. Contrary to the aSSllmption ofllniform biofilm thickness, the accllffilliation starts frOll1 the inlet, and the bacterial concentration in aqlleous phase moving towards the olitiet declines, sloyving the accumulation at the outlet. Increasing the desorption rate, redllces the dliration of Phase I, speeding IIp the accllmlilation. It was also observed that Phase II is of longer duration than Phase I. Increasing the attachment rate lengthens the accliffililation period. High rates of detachment speeds up the transport. The grovvth and decay rates have no significant effect on transport, althollgh increases the concentrations in both aqueous and sorbed phases are observed. Irreversible adsorption can stop accllillulation completely if the vallIes are high.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Immobilized lipase B from Candida antarctica (Novozym® 435, N435) was utilized as part of a chemoenzymatic strategy for the synthesis of branched polyesters based on a cyclotetrasiloxane core in the absence of solvent. Nuclear magnetic resonance spectroscopy and matrix-assisted laser desorption ionization time-of-flight mass spectrometry were utilized to monitor the reactions between tetraester cyclotetrasiloxanes and aliphatic diols. The enzyme-mediated esterification reactions can achieve 65– 80% consumption of starting materials in 24–48 h. Longer reaction times, 72–96 h, resulted in the formation of cross-linked gel-like networks. Gel permeation chromatography of the polymers indicated that the masses were Mw ¼ 11 400, 13 100, and 19 400 g mol 1 for the substrate pairs of C7D4 ester/ octane-1,8-diol, C10D4 ester/pentane-1,5-diol and C10D4 ester/octane-1,8-diol respectively, after 48 h. Extending the polymerization for an additional 24 h with the C10D4 ester/octane-1,8-diol pair gave Mw ¼ 86 800 g mol 1. To the best of our knowledge this represents the first report using lipase catalysis to produce branched polymers that are built from a cyclotetrasiloxane core.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Avec la hausse mondiale de la fréquence des floraisons de cyanobactéries (CB), dont certaines produisent des cyanotoxines (CT), le développement d’une méthode de détection/quantification rapide d’un maximum de CT s’impose. Cette méthode permettrait de faire un suivi quotidien de la toxicité de plans d’eau contaminés par des CB et ainsi d’émettre rapidement des avis d’alerte appropriés afin de protéger la santé publique. Une nouvelle technologie utilisant la désorption thermique induite par diode laser (LDTD) couplée à l’ionisation chimique sous pression atmosphérique (APCI) et reliée à la spectrométrie de masse en tandem (MS/MS) a déjà fait ses preuves avec des temps d'analyse de l’ordre de quelques secondes. Les analytes sont désorbés par la LDTD, ionisés en phase gazeuse par APCI et détectés par la MS/MS. Il n’y a donc pas de séparation chromatographique, et la préparation de l’échantillon avant l’analyse est minimale selon la complexité de la matrice contenant les analytes. Parmi les quatre CT testées (microcystine-LR, cylindrospermopsine, saxitoxine et anatoxine-a (ANA-a)), seule l’ANA-a a généré une désorption significative nécessaire au développement d’une méthode analytique avec l’interface LDTD-APCI. La forte polarité ou le poids moléculaire élevé des autres CT empêche probablement leur désorption. L’optimisation des paramètres instrumentaux, tout en tenant compte de l’interférence isobarique de l’acide aminé phénylalanine (PHE) lors de la détection de l’ANA-a par MS/MS, a généré une limite de détection d’ANA-a de l’ordre de 1 ug/L. Celle-ci a été évaluée à partir d’une matrice apparentée à une matrice réelle, démontrant qu’il serait possible d’utiliser la LDTD pour effectuer le suivi de l’ANA-a dans les eaux naturelles selon les normes environnementales applicables (1 à 12 ug/L). Il a été possible d’éviter l’interférence isobarique de la PHE en raison de sa très faible désorption avec l’interface LDTD-APCI. En effet, il a été démontré qu’une concentration aussi élevée que 500 ug/L de PHE ne causait aucune interférence sur le signal de l’ANA-a.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La fumée du tabac est un aérosol extrêmement complexe constitué de milliers de composés répartis entre la phase particulaire et la phase vapeur. Il a été démontré que les effets toxicologiques de cette fumée sont associés aux composés appartenant aux deux phases. Plusieurs composés biologiquement actifs ont été identifiés dans la fumée du tabac; cependant, il n’y a pas d’études démontrant la relation entre les réponses biologiques obtenues via les tests in vitro ou in vivo et les composés présents dans la fumée entière du tabac. Le but de la présente recherche est de développer des méthodes fiables et robustes de fractionnement de la fumée à l’aide de techniques de séparation analytique et de techniques de détection combinés à des essais in vitro toxicologiques. Une étude antérieure réalisée par nos collaborateurs a démontré que, suite à l’étude des produits de combustion de douze principaux composés du tabac, l’acide chlorogénique s’est avéré être le composé le plus cytotoxique selon les test in vitro du micronoyau. Ainsi, dans cette étude, une méthode par chromatographie préparative en phase liquide a été développée dans le but de fractionner les produits de combustion de l’acide chlorogénique. Les fractions des produits de combustion de l’acide chlorogénique ont ensuite été testées et les composés responsables de la toxicité de l’acide chlorogénique ont été identifiés. Le composé de la sous-fraction responsable en majeure partie de la cytoxicité a été identifié comme étant le catéchol, lequel fut confirmé par chromatographie en phase liquide/ spectrométrie de masse à temps de vol. Des études récentes ont démontré les effets toxicologiques de la fumée entière du tabac et l’implication spécifique de la phase vapeur. C’est pourquoi notre travail a ensuite été focalisé principalement à l’analyse de la fumée entière. La machine à fumer Borgwaldt RM20S® utilisée avec les chambres d’exposition cellulaire de British American Tobacco permettent l’étude in vitro de l’exposition de cellules à différentes concentrations de fumée entière du tabac. Les essais biologiques in vitro ont un degré élevé de variabilité, ainsi, il faut prendre en compte toutes les autres sources de variabilité pour évaluer avec précision la finalité toxicologique de ces essais; toutefois, la fiabilité de la génération de la fumée de la machine n’a jamais été évaluée jusqu’à maintenant. Nous avons donc déterminé la fiabilité de la génération et de la dilution (RSD entre 0,7 et 12 %) de la fumée en quantifiant la présence de deux gaz de référence (le CH4 par détection à ionisation de flamme et le CO par absorption infrarouge) et d’un composé de la phase particulaire, le solanesol (par chromatographie en phase liquide à haute performance). Ensuite, la relation entre la dose et la dilution des composés de la phase vapeur retrouvée dans la chambre d’exposition cellulaire a été caractérisée en utilisant une nouvelle technique d’extraction dite par HSSE (Headspace Stir Bar Sorptive Extraction) couplée à la chromatographie en phase liquide/ spectrométrie de masse. La répétabilité de la méthode a donné une valeur de RSD se situant entre 10 et 13 % pour cinq des composés de référence identifiés dans la phase vapeur de la fumée de cigarette. La réponse offrant la surface maximale d’aire sous la courbe a été obtenue en utilisant les conditions expérimentales suivantes : intervalle de temps d’exposition/ désorption de 10 0.5 min, température de désorption de 200°C pour 2 min et température de concentration cryogénique (cryofocussing) de -75°C. La précision de la dilution de la fumée est linéaire et est fonction de l’abondance des analytes ainsi que de la concentration (RSD de 6,2 à 17,2 %) avec des quantités de 6 à 450 ng pour les composés de référence. Ces résultats démontrent que la machine à fumer Borgwaldt RM20S® est un outil fiable pour générer et acheminer de façon répétitive et linéaire la fumée de cigarette aux cultures cellulaires in vitro. Notre approche consiste en l’élaboration d’une méthodologie permettant de travailler avec un composé unique du tabac, pouvant être appliqué à des échantillons plus complexes par la suite ; ex : la phase vapeur de la fumée de cigarette. La méthodologie ainsi développée peut potentiellement servir de méthode de standardisation pour l’évaluation d’instruments ou de l’identification de produits dans l’industrie de tabac.