576 resultados para photoelectrochemical disinfection


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The year so far has been a slow start for many businesses, but at least we have not seen the collapse of as many businesses that we were seeing around two years ago. We are, however, still well and truly in the midst of a global recession. Interest rates are still at an all time low, UK house prices seem to be showing little signs of increase (except in London where everyone still seems to want to live!) and for the ardent shopper there are bargains to be had everywhere. It seems strange that prices on the high street do not seem to have increased in over ten years. Mobile phones, DVD players even furniture seems to be cheaper than they used to be. Whist much of this is down to cheaper manufacturing and the rest could probably be explained by competition within the market place. Does this mean that quality suffered too? Now that we live in a world when if a television is not working it is thrown away and replaced. There was a time when you would take it to some odd looking man that your father would know who could fix it for you. (I remember our local television fix-it man, with his thick rimmed bifocal spectacles and a poor comb-over; he had cardboard boxes full of resistors and electrical wires on the floor of his front room that smelt of soldering irons!) Is this consumerism at an extreme or has this move to disposability made us a better society? Before you think these are just ramblings there is a point to this. According to latest global figures of contact lens sales the vast majority of contact lenses fitted around the world are daily, fortnightly or monthly disposable hydrogel lenses. Certainly in the UK over 90% of lenses are disposable (with daily disposables being the most popular, having a market share of over 50%). This begs the question – is this a good thing? Maybe more importantly, do our patients benefit? I think it is worth reminding ourselves why we went down the disposability route with contact lenses in the first place, and unlike electrical goods it was not just so we did not have to take them for repair! There are the obvious advantages of overcoming problems of breakage and tearing of lenses and the lens deterioration with age. The lenses are less likely to be contaminated and the disinfection is either easier or not required at all (in the case of daily disposable lenses). Probably the landmark paper in the field was the work more commonly known as the ‘Gothenburg Study’. The paper, entitled ‘Strategies for minimizing the Ocular Effects of Extended Contact Lens Wear’ published in the American Journal of Optometry in 1987 (volume 64, pages 781-789) by Holden, B.A., Swarbrick, H.A., Sweeney, D.F., Ho, A., Efron, N., Vannas, A., Nilsson, K.T. They suggested that contact lens induced ocular effects were minimised by: •More frequently removed contact lenses •More regularly replaced contact lenses •A lens that was more mobile on the eye (to allow better removal of debris) •Better flow of oxygen through the lens All of these issues seem to be solved with disposability, except the oxygen issue which has been solved with the advent of silicone hydrogel materials. Newer issues have arisen and most can be solved in practice by the eye care practitioner. The emphasis now seems to be on making lenses more comfortable. The problems of contact lens related dry eyes symptoms seem to be ever present and maybe this would explain why in the UK we have a pretty constant contact lens wearing population of just over three million but every year we have over a million dropouts! That means we must be attracting a million new wearers every year (well done to the marketing departments!) but we are also losing a million wearers every year. We certainly are not losing them all to the refractive surgery clinics. We know that almost anyone can now wear a contact lens and we know that some lenses will solve problems of sharper vision, some will aid comfort, and some will be useful for patients with dry eyes. So if we still have so many dropouts then we must be doing something wrong! I think the take home message has to be ‘must try harder’! I must end with an apology for two errors in my editorial of issue 1 earlier this year. Firstly there was a typo in the first sentence; I meant to state that it was 40 years not 30 years since the first commercial soft lens was available in the UK. The second error was one that I was unaware of until colleagues Geoff Wilson (Birmingham, UK) and Tim Bowden (London, UK) wrote to me to explain that soft lenses were actually available in the UK before 1971 (please see their ‘Letters to the Editor’ in this issue). I am grateful to both of them for correcting the mistake.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The persistence of Salmonella spp. in low moisture foods is a challenge for the food industry as despite control strategies already in place, notable outbreaks still occur. The aim of this study was to characterise isolates of Salmonella, known to be persistent in the food manufacturing environment, by comparing their microbiological characteristics with a panel of matched clinical and veterinary isolates. The gross morphology of the challenge panel was phenotypically characterised in terms of cellular size, shape and motility. In all the parameters measured, the factory isolates were indistinguishable from the human, clinical and veterinary strains. Further detailed metabolic profiling was undertaken using the biolog Microbial ID system. Multivariate analysis of the metabolic microarray revealed differences in metabolism of the factory isolate of S.Montevideo, based on its upregulated ability to utilise glucose and the sugar alcohol groups. The remainder of the serotype-matched isolates were metabolically indistinguishable. Temperature and humidity are known to influence bacterial survival and through environmental monitoring experimental parameters were defined. The results revealed Salmonella survival on stainless steel was affected by environmental temperatures that may be experienced in a food processing environment; with higher survival rates (D25=35.4) at temperatures at 25°C and lower humidity levels of 15% RH, however a rapid decline in cell count (D10=3.4) with lower temperatures of 10°C and higher humidity of 70% RH. Several resident factories strains survived in higher numbers on stainless steel (D25=29.69) compared to serotype matched clinical and veterinary isolates (D25=22.98). Factory isolates of Salmonella did not show an enhanced growth rate in comparison to serotype matched solates grown in Luria broth, Nutrient broth and M9 minimal media indicating that as an independent factor, growth was unlikely to be a major factor driving Salmonella persistence. Using a live / dead stain coupled with fluorescence microscopy revealed that when no longer culturable, isolates of S.Schwarzengrund entered into a viable nonculturable state. The biofilm forming capacity of the panel was characterised and revealed that all were able to form biofilms. None of the factory isolates showed an enhanced capability to form biofilms in comparison to serotype-matched isolates. In disinfection studies, planktonic cells were more susceptible to disinfectants than cells in biofilm and all the disinfectants tested were successful in reducing bacterial load. Contact time was one of the most important factors for reducing bacterial populations in a biofilm. The genomes of eight strains were sequenced. At the nucleotide and amino acid level the food factory isolates were similar to those of isolates from other environments; no major genomic rearrangements were observed, supporting the conclusions of the phenotypic and metabolic analysis. In conclusion, having investigated a variety of morphological, biochemical and genomic factors, it is unlikely that the persistence of Salmonella in the food manufacturing environment is attributable to a single phenotypic, metabolic or genomic factor. Whilst a combination of microbiological factors may be involved it is also possible that strain persistence in the factory environment is a consequence of failure to apply established hygiene management principles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The treatment of wastewater is essential to human health. One of the most important steps is the disinfection treatment which uses chlorine to eliminate bacteria as required by environmental agencies. However, the identification of potentially toxic byproducts generated by this method, such as trihalomethanes, has stimulated the development of new alternative disinfection technologies. Among them, heterogeneous photocatalysis, TiO2 photocatalysis and electrochemical disinfection are considered suitable alternatives to the chlorination method. Thus, the present dissertation analyzes the evolution of active chlorine species in a synthetic NaCl solution and it is tested to treat a synthetic solution of the dye Reactive Blue 19 using boron-doped diamond (BDD) and ruthenium oxide (Ti/Ru0.3Ti0.7O2) as anodes. The indirect electrochemical process was discussed in terms of mineralization of the total organic load and percentage of color removal in order to evaluate the applicability of electrochemical technology. Electrochemical experiments were carried out with different current densities (25, 50 and 75 mA.cm-2) during 120 minutes. On the other hand, other important parameter in this study was the influence of the proportion sp3/sp2 on BDD anode on the performance of the evolution of active chlorine species which was investigated by electrolytic techniques (linear polarization), with the intention of determining the related training oxidizing species and consumption energy to chemical or electrochemical reactions. From the results, it can be noted that the BDD electrode showed better efficiency throughout the electrochemical process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The treatment of wastewater is essential to human health. One of the most important steps is the disinfection treatment which uses chlorine to eliminate bacteria as required by environmental agencies. However, the identification of potentially toxic byproducts generated by this method, such as trihalomethanes, has stimulated the development of new alternative disinfection technologies. Among them, heterogeneous photocatalysis, TiO2 photocatalysis and electrochemical disinfection are considered suitable alternatives to the chlorination method. Thus, the present dissertation analyzes the evolution of active chlorine species in a synthetic NaCl solution and it is tested to treat a synthetic solution of the dye Reactive Blue 19 using boron-doped diamond (BDD) and ruthenium oxide (Ti/Ru0.3Ti0.7O2) as anodes. The indirect electrochemical process was discussed in terms of mineralization of the total organic load and percentage of color removal in order to evaluate the applicability of electrochemical technology. Electrochemical experiments were carried out with different current densities (25, 50 and 75 mA.cm-2) during 120 minutes. On the other hand, other important parameter in this study was the influence of the proportion sp3/sp2 on BDD anode on the performance of the evolution of active chlorine species which was investigated by electrolytic techniques (linear polarization), with the intention of determining the related training oxidizing species and consumption energy to chemical or electrochemical reactions. From the results, it can be noted that the BDD electrode showed better efficiency throughout the electrochemical process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The production of KPC (Klebsiella pneumoniae carbapenemase) has become an important mechanism of carbapenem-resistance among Enterobacteriaceae strains. In Brazil, KPC is already widespread and its incidence has increased significantly, reducing treatment options. The “perfect storm” combination of the absence of new drug developmentand the emergence of multidrug-resistant strains resulted in the need for the use of older drugs, with greater toxicity, such as polymyxins. Aims: To determine the occurrence of carbapenemase-producing strains in carbapenem-resistant Enterobacteriaceae isolated from patients with nosocomial infection/colonization during September/2014 to August/2015, to determine the risk factors associated with 30-day- mortality and the impact of inappropriate therapy. Materials and Methods: We performed a case control study to assess the risk factors (comorbidities, invasive procedures and inappropriate antimicrobial therapy) associated with 30-day-mortality, considering the first episode of infection in 111 patients. The resistance genes blaKPC, blaIMP, blaVIM and blaNDM-1 were detected by polymerase chain reaction technique. Molecular typing of the strains involved in the outbreak was performed by pulsed field gel electrophoresis technique. The polymyxin resistance was confirmed by the microdilution broth method. Results: 188 episodes of carbapenem-resistant Enterobacteriaceae infections/colonizations were detected; of these, 122 strains were recovered from the hospital laboratory. The presence of blaKPC gene were confirmed in the majority (74.59%) of these isolates. It was not found the presence of blaIMP , blaVIM and blaNDM-1 genes. K. pneumoniae was the most frequent microorganism (77,13%), primarily responsible for urinary tract infections (21,38%) and infections from patients of the Intensive Care Unit (ICU) (61,38%). Multivariate statistical analysis showed as predictors independently associated with mortality: dialysis and bloodstream infection. The Kaplan-Meier curve showed a lower probability of survival in the group of patients receiving antibiotic therapy inappropriately. Antimicrobial use in adult ICU varied during the study period, but positive correlation between increased incidence of strains and the consumption was not observed. In May and July 2015, the occurrence rates of carbapenem-resistant Enterobacteriaceae KPC-producing per 1000 patient-days were higher than the control limit established, confirming two outbreaks, the first caused by colistin-susceptible KPC-producing K. pneumoniae isolates, with a polyclonal profile and the second by a dominant clone of colistin-resistant (≥ 32 μg/mL) KPC-producing K. pneumoniae. The cross transmission between patients became clear by the temporal and spatial relationships observed in the second outbreak, since some patients occupied the same bed, showing problems in hand hygiene adherence among healthcare workers and inadequate terminal disinfection of environment. The outbreak was contained when the ICU was closed to new admissions. Conclusions: The study showed an endemicity of K. pneumoniae KPC-producing in adult ICU, progressing to an epidemic monoclonal expansion, resulted by a very high antibiotic consumption of carbapenems and polymyxins and facilitated by failures in control measures the unit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The realization of an energy future based on safe, clean, sustainable, and economically viable technologies is one of the grand challenges facing modern society. Electrochemical energy technologies underpin the potential success of this effort to divert energy sources away from fossil fuels, whether one considers alternative energy conversion strategies through photoelectrochemical (PEC) production of chemical fuels or fuel cells run with sustainable hydrogen, or energy storage strategies, such as in batteries and supercapacitors. This dissertation builds on recent advances in nanomaterials design, synthesis, and characterization to develop novel electrodes that can electrochemically convert and store energy.

Chapter 2 of this dissertation focuses on refining the properties of TiO2-based PEC water-splitting photoanodes used for the direct electrochemical conversion of solar energy into hydrogen fuel. The approach utilized atomic layer deposition (ALD); a growth process uniquely suited for the conformal and uniform deposition of thin films with angstrom-level thickness precision. ALD’s thickness control enabled a better understanding of how the effects of nitrogen doping via NH3 annealing treatments, used to reduce TiO2’s bandgap, can have a strong dependence on TiO2’s thickness and crystalline quality. In addition, it was found that some of the negative effects on the PEC performance typically associated with N-doped TiO2 could be mitigated if the NH3-annealing was directly preceded by an air-annealing step, especially for ultrathin (i.e., < 10 nm) TiO2 films. ALD was also used to conformally coat an ultraporous conductive fluorine-doped tin oxide nanoparticle (nanoFTO) scaffold with an ultrathin layer of TiO2. The integration of these ultrathin films and the oxide nanoparticles resulted in a heteronanostructure design with excellent PEC water oxidation photocurrents (0.7 mA/cm2 at 0 V vs. Ag/AgCl) and charge transfer efficiency.

In Chapter 3, two innovative nanoarchitectures were engineered in order to enhance the pseudocapacitive energy storage of next generation supercapacitor electrodes. The morphology and quantity of MnO2 electrodeposits was controlled by adjusting the density of graphene foliates on a novel graphenated carbon nanotube (g-CNT) scaffold. This control enabled the nanocomposite supercapacitor electrode to reach a capacitance of 640 F/g, under MnO2 specific mass loading conditions (2.3 mg/cm2) that are higher than previously reported. In the second engineered nanoarchitecture, the electrochemical energy storage properties of a transparent electrode based on a network of solution-processed Cu/Ni cores/shell nanowires (NWs) were activated by electrochemically converting the Ni metal shell into Ni(OH)2. Furthermore, an adjustment of the molar percentage of Ni plated onto the Cu NWs was found to result in a tradeoff between capacitance, transmittance, and stability of the resulting nickel hydroxide-based electrode. The nominal area capacitance and power performance results obtained for this Cu/Ni(OH)2 transparent electrode demonstrates that it has significant potential as a hybrid supercapacitor electrode for integration into cutting edge flexible and transparent electronic devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Boron-doped diamond is a promising electrode material for a number of applications providing efficient carrier transport, a high stability of the electrolytic performance with time, a possibility for dye-sensitizing with photosensitive molecules, etc. It can be functionalized with electron donor molecules, like phthalocyanines or porphyrins, for the development of light energy conversion systems. For effective attachment of such molecules, the diamond surface has to be modified by plasma- or photo-chemical processes in order to achieve a desired surface termination. In the present work, the surface modifications of undoped and boron-doped nanocrystalline diamond (NCD) films and their functionalization with various phthalocyanines (Pcs) were investigated. The NCD films have been prepared by hot filament chemical vapor deposition (HFCVD) on silicon substrates and were thereafter subjected to modifications with O2 or NH3 plasmas or UV/O3 treatments for exchange of the H-termination of the as-grown surface. The effectiveness of the modifications and their stability with time during storage under different ambients were studied by contact angle measurements and X-ray photoelectron spectroscopy (XPS). Furthermore, the surface roughness after the modifications was investigated with atomic force microscopy (AFM) and compared to that of as-grown samples in order to establish the appearance of etching of the surface during the treatment. The as-grown and the modified NCD surfaces were exposed to phthalocyanines with different metal centers (Ti, Cu, Mn) or with different side chains. The results of the Pc grafting were investigated by XPS and Raman spectroscopy. XPS revealed the presence of nitrogen stemming from the Pc molecules and traces of the respective metal atoms with ratios close to those in the applied Pc. In a next step Raman spectra of Ti-Pc, Cu-Pc and Mn-Pc were obtained with two different excitation wavelengths (488 and 785 nm) from droplet samples on Si after evaporation of the solvent in order to establish their Raman fingerprints. The major differences in the spectra were assigned to the effect of the size of the metal ion on the structure of the phthalocyanine ring. The spectra obtained were used as references for the Raman spectra of NCD surfaces grafted with Pc. Finally, selected boron doped NCD samples were used after their surface modification and functionalization with Pc for the preparation of electrodes which were tested in a photoelectrochemical cell with a Pt counter electrode and an Ag/AgCl reference electrode. The light sources and electrolytes were varied to establish their influence on the performance of the dye-sensitized diamond electrodes. Cyclic voltammetry measurements revealed broad electrochemical potential window and high stability of the electrodes after several cycles. The open circuit potential (OCP) measurements performed in dark and after illumination showed fast responses of the electrodes to the illumination resulting in photocurrent generation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-08

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: Ao longo do tempo o Tratamento Endodôntico Não Cirúrgico tem sido das áreas da Medicina Dentária que mais tem evoluído. Todos os passos do tratamento têm sido revistos de forma a aumentar a taxa de sucesso. O controlo microbiológico é crucial para que o tratamento seja um sucesso a curto, médio e longo prazo. A assepsia deve ser mantida em todas as fases deste tratamento para que este seja um sucesso. Objetivo: Ao longo do meu percurso académico pude concluir que a fase da descontaminação dos cones, aquando a obturação (fase final do Tratamento Endodôntico Não Cirúrgico) era desvalorizada, o que me levou a efetuar uma revisão bibliográfica de modo a poder melhorar os meus conhecimentos e técnica. Material e Métodos: Para a elaboração deste trabalho foi realizada uma pesquisa bibliográfica recorrendo aos seguintes motores de busca: B-on, PubMed, Scielo e ScienceDirect, com as seguintes palavras-chave: “decontamination in endodontics”;” disinfection in endodontics”; “root canal irrigants”; “endodontics microbiology”; “Candida albicans“; “Enterococcus faecalis”; “sodium hypochlorite ”; “alcohol”; “contamination during Obturation”; “clorohexidine”; “filling materials endodontics”; “termoplastic gutta-percha”; “obturation material”; “Mineral Trioxide Aggregate”; “resilon”; “resin cement”; “resin material for root canal obturation”; “resin sealer”; “root canal”; “root canal sealing”; “root canal filling materials”; “condensation in endodontics”; “lateral condensation”; “gutta-percha”; “microlekeage”; “system B”; “fluid filtration model”;“dye penetration”. Como critério de inclusão estabeleceu-se que os artigos deveriam ser em Português, Inglês ou Espanhol e publicados entre 1995 e 2015. Dos resultados apresentados foram utilizados 110 artigos, pesquisados entre Maio de 2015 e 20 de Outubro de 2015. Foram ainda consultados livros de referência nestes mesmos locais. Conclusão: a presença de bactérias e os seus subprodutos no sistema tridimensional de canais está diretamente implicado com o insucesso do Tratamento Endodôntico. A descontaminação dos cones de guta-percha, é, portanto, um processo importante no Tratamento Endodôntico pois impede que os cones sejam colocados nos canais radiculares, estando contaminados por microorganismos que inviabilizam o tratamento efetuado. A submersão dos cones durante um minuto em clorohexidina a 2% ou hipoclorito a 5,25% está indicado e comprovado como um processo eficiente de desinfeção dos cones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: O objetivo da terapia endodôntica é eliminar a infeção presente nos canais radiculares e prevenir a reinfeção dos mesmos, criando assim as condições para a manutenção da peça dentária em função e livre de patologia pulpar ou peri-apical. A complexa anatomia dos canais faz com que seja impossível uma limpeza completa dos mesmos. Para se conseguir um bom resultado clínico é de extrema importância utilizarmos técnicas e procedimentos que visem uma utilização combinada de instrumentação mecânica e desinfeção com soluções de irrigação. Objetivo: Revisão bibliográfica sobre sistemas auxiliares de desinfeção em Endodontia, abordando as suas principais vantagens e limitações e apresentando estudos que provam a sua importância para o sucesso do tratamento endodôntico. Materiais e métodos: Realizou-se uma pesquisa eletrónica nos principais motores de busca online tais como PubMed, B-On, Scielo e Science Direct e em livros científicos sobre a temática, utilizando palavras-chave em inglês tais como “irrigation techniques”, “sonic irrigation”, “EndoVac”, “EDTA”, “hypoclorite sodium”, “passive ultrasonic irrigation”, “apical negative pressure irrigation”, “root canal irrigation”, “EndoAtivator”, e ainda alguns termos em português tais como “insucesso em endodontia”, “hipoclorito de sódio” “ácido cítrico” e “irrigação sónica e ultrasónica”. Da pesquisa efectuada entre Junho e Novembro de 2015 e cujo critério de inclusão foram artigos datados de 2001 a 2015, escolheu-se 65 artigos em inglês, 4 em português e 1 em espanhol, dos quais se utilizaram 44 artigos. Além dos artigos analisou-se 2 livros, dos quais se utilizou 1. Resultados: Os artigos analisados apresentam como principais resultados que a combinação de instrumentação mecânica e a irrigação reduz mas não elimina totalmente as bactérias. Até à data não existem soluções de irrigação ideais. Têm-se desenvolvido técnicas capazes de combater as dificuldades encontradas e aumentar as potencialidades da irrigação, cada uma apresentando suas vantagens e desvantagens. Dos resultados constatados, a literatura científica aparenta reconhecer o Sistema EndoVac como o melhor em termos de biossegurança e o sistema de irrigação ultrasónica passiva como o melhor em termos de desinfecção e limpeza. Conclusão: Uma combinação de soluções com uma sequência específica é aparentemente necessária para atingir o sucesso endodôntico, bem como uma escolha adequada da técnica. As novas técnicas desenvolvidas tais como a ativação dinâmica manual, irrigação ultrasónica passiva, ativação sónica e sistemas de pressão apical negativa apresentam melhores resultados quando associados a irrigantes adequados como o hipoclorito, EDTA, ácido cítrico, clorohexidina e álcool. No entanto, concluiu-se que mais investigação é necessária para melhorar o sucesso do tratamento endodôntico não-cirúrgico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El presente trabajo de tesis tuvo como finalidad evaluar la flora micológica del maíz seco y su harina producidos en la parroquia San Juan - Cantón Gualaceo con el fin de aportar con información sobre la calidad de estos alimentos. Además se evaluaron los siguientes factores para el desarrollo de la flora micológica: temperatura, actividad acuosa, almacenamiento; así como también el crecimiento en distintos medios de cultivos y el uso de la desinfección del grano como parte de la técnica de siembra. La detección, recuento y aislamiento de hongos se realizó de acuerdo a la técnica de recuento en placa por siembra en profundidad para la harina y en el caso del grano por la técnica de siembra directa, con y sin desinfección de la superficie del grano utilizándose el agar MEA (Agar Extracto de Malta), PDA (Agar Papa Dextrosa) y DRBC (Agar Rosa de Bengala Diclorán) y sometiendo a dos tratamientos térmicos (18°C vs 25°C). Se encontró que la micoflora presente en las muestras analizadas corresponde a los géneros Penicillium, Fusarium, Rhizopus, Aspergillus y levaduras, siendo el género predominante Penicillium tanto en el grano como en la harina. La temperatura óptima para el crecimiento fue 25°C; y a su vez el crecimiento fue mejor sin desinfectar las superficies del grano. El crecimiento micológico varió dependiendo del medio, siendo PDA el más óptimo para Penicillium y Rhizopus, mientras que para Fusarium y Aspergillus no hubo diferencia. Igualmente se encontró que la actividad acuosa influyó en forma proporcional al crecimiento micológico y que el almacenamiento controlado influyó positivamente en su disminución.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A abordagem Endodôntica tem como grandes objetivos a manutenção funcional e estética do dente no sistema estomatognático. O sucesso desta abordagem terapêutica depende da realização eficiente da desinfeção, conformação e obturação do canal radicular. Estas etapas podem tornar-se difíceis de realizar na presença de dentes calcificados. A localização e manipulação dos canais calcificados são considerados um grande desafio durante a abordagem Endodôntica. Na tentativa de localização dos canais podem ocorrer erros de procedimento, como perfurações, fraturas de instrumentos e desvios do trajeto original do canal. Atualmente, vários recursos clínicos são utilizados para auxiliar estes procedimentos, como radiografias, microscópio operatório e o ultrassom. A calcificação pode ser resultado do processo fisiológico de envelhecimento, ou da deposição de dentina como mecanismo de defesa da polpa contra agentes agressores externos. Os dentes com calcificação não costumam apresentar sintomatologia, sendo o diagnóstico muitas vezes acidental. Clinicamente, a coroa dentária apresenta coloração alterada, e radiograficamente os canais apresentam os seus limites pulpares apagados, revelando obstrução parcial ou completa da câmara pulpar e dos canais, devido à deposição excessiva de dentina. A abordagem apropriada para dentes calcificados pode ser um dilema para o clínico. Esta deve ser feita a partir de decisão prudente entre a intervenção Endodôntica para o dente envolvido e outras intervenções restauradoras estéticas disponíveis. A maioria da literatura não apoia a intervenção Endodôntica a menos que seja detetado patologia apical ou sintomatologia do dente envolvido. A observação e o exame periódico do dente calcificado são as opções geralmente adotadas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O principal objetivo do tratamento endodôntico não cirúrgico reside na limpeza e desinfeção do sistema tridimensional de canais radiculares, removendo os microrganismos existentes e conseguindo restituir a função do dente, em vez de o extrair. É fácil compreender que o insucesso deste tratamento deve-se, essencialmente, à sobrevivência dos microrganismos nos canais radiculares. Por isso, a irrigação e a desinfeção são essenciais para alcançar o sucesso do tratamento. Devido à morfologia do canal e à incapacidade de determinar a localização exata do ápice, as soluções irrigadoras têm de alcançar as ramificações dos canais radiculares e outras áreas inacessíveis à instrumentação. Após a pesquisa efetuada, concluiu-se que o irrigante mais utilizado universalmente é o hipoclorito de sódio. Para além disso, o hipoclorito de sódio, o EDTA e o ácido cítrico ajudam na instrumentação e no alargamento do canal, devido à desmineralização dentinária que provocam. Já a clorexidina, apesar de não provocar qualquer desmineralização, ao ser associada ao hipoclorito de sódio, origina um precipitado que vai interferir no selamento dos canais radiculares. Assim, com o presente trabalho, pretende-se realizar uma revisão bibliográfica sobre os diversos irrigantes e sistemas auxiliares de irrigação, que se encontram associados à desinfeção endodôntica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: O trabalho elaborado desenvolve o tema seguinte: Novas tecnologias associadas ao retratamento endodôntico não cirúrgico. Desde o início da medicina dentária que somos deparados com o insucesso nos tratamentos realizados, na endodôntia sendo um acontecimento regular na prática diária. Quando o tratamento Endodontico não cirúrgico não é eficaz na resolução de patologias pulpares e ocorre recidiva da patologia, é necessário a realização do retratamento endodôntico não cirúrgico. Uma vez que o retratamento endodôntico, respeita os mesmos princípios do tratamento Endodontico, sendo estes a desinfeção do sistema de canais radiculares, a sua instrumentação e obturação. Esta prática está indicada por vários motivos, anatómicos, microbiológicos, erros de instrumentação, erros de obturação e as próprias limitações dos materiais. Objetivos: Esta dissertação tem como objetivo analisar, e verificar as razões que levam a necessidade da realização de retratamentos endodônticos não cirúrgicos, aos métodos utilizados na realização de retratamentos comparando-os entre si. Tendo sido realizada uma revisão bibliográfica de modo a verificar: as causas de insucesso, limitações dos materiais, técnicas de obturação, agentes químicos e sistemas de instrumentação. Materiais e Métodos: Para a obtenção da informação necessária para a elaboração da presente dissertação, foi realizada uma pesquiza bibliográfica nas bases de dados da Pubmed, B-on, Scielo, Science Direct e no Google Académico. Através das seguintes palavras-chave: “Root canal treatment”, “Endodontic sucess”, “Endodontic retreatment”, “Endodontic Failure causes”, “Root canal retreatment materials”, “Endodontic retreatment metods”, “Chloroform”, “ProTaper, Reciproc”, “Haloten”, “Orange oil”, “Eucaliptol”, “Ultrassonic instrumentation”, “obturation material”, “root filling”. Conclusão: No trabalho realizado é possível concluir que o insucesso tem múltiplas causas, que hoje em dia existem novos métodos e técnicas que nos permitem a resolução das falhas nos tratamentos primários, sendo que estes novos métodos e técnicas se revelaram mais eficazes que os tradicionais, demonstrando uma maior probabilidade de eliminação dos fatores causais das reinfeções.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nos últimos anos, o processo de irrigação durante tratamento Endodôntico tem vindo a ganhar importância e a ser alvo de sucessivos estudos. Sabe-se agora que a única razão de instrumentar o sistema de canais radiculares é para se conseguir irrigar e consequentemente proceder-se à limpeza e desinfecção do dente. São vários os irrigantes utilizados durante a irrigação Endodôntica. Dentro das várias substancias químicas existentes, o Hipoclorito de Sódio, devido às suas características, é o mais utilizado mundialmente pelos Médicos Dentistas. As principais características que apresenta são o seu poder antimicrobiano assim como a sua capacidade de dissolução da matéria orgânica presente no interior dos canais radiculares. Dependentemente do caso clinico, o Médico Dentista deve saber selecionar qual o melhor irrigante a utilizar, se pode ou não utilizar o Hipoclorito de Sódio e, caso não seja possível, deve conhecer as alternativas para realizar de forma conveniente o tratamento endodôntico. É importante conhecerem-se os riscos e possíveis acidentes que podem ocorrer durante o manuseamento do Hipoclorito de Sódio e, caso o Médico Dentista se depare com uma situação destas, deve saber como actuar de forma eficaz.