979 resultados para high-bandwidth LCL filter
Resumo:
A simple method for the measurement of pindolol enantiomers by HPLC is presented. Alkalinized serum or urine is extracted with ethyl acetate and the residue remaining after evaporation of the organic layer is then derivatised with (S)-(-)-alpha-methylbenzyl isocyanate. The diastereoisomers of derivatised pindolol and metoprolol (internal standard) are separated by high-performance liquid chromatography (HPLC) using a C-18 silica column and detected using fluorescence (excitation lambda: 215 nm, emission lambda: 320 nm). The assay displays reproducible linearity for pindolol enantiomers with a correlation coefficient of r(2) greater than or equal to 0.998 over the concentration range 8-100 ng ml(-1) for plasma and 0.1-2.5 mu g ml(-1) for urine. The coefficient of variation for accuracy and precision of the quality control samples for both plasma and urine are consistently
Resumo:
Mycophenolic acid is an immunosuppressant administered as a bioavailable ester, mycophenolate mofetil. The pharmacokinetics of mycophenolic acid have been reported to be variable. Accurate measurement of concentrations of this drug could be important to adjust doses. The aim of this study was to compare the enzyme-multiplied immunoassay technique (EMIT [Dade Behring; San Jose, CA, U.S.A.]) for mycophenolic acid with a high-performance liquid chromatographic (HPLC) assay using samples collected from renal transplant recipients. The HPLC assay used solid phase extraction and a C18 stationary phase with ultraviolet (UV) detection (254 nm). The immunoassay required no manual sample preparation. Plasma samples (n = 102) from seven patients, collected at various times after a dose, were analyzed using both methods. Both assays fulfilled quality-control criteria. Higher concentrations were consistently measured in patient samples when using EMIT. The mean (+/- standard deviation [SD]) bias (EMIT-HPLC) was 1.88 +/- 0.86 mg/L. The differences in concentrations were higher in the middle of a dosage interval, suggesting that a metabolite might have been responsible for overestimation. Measurement of glucuronide concentrations by HPLC demonstrated only a weak correlation between assay differences and glucuronide concentrations. If the crossreacting substance is active, EMIT could provide a superior measure of immunosuppression; if inactive, further work is needed to improve antibody specificity. In conclusion, it was found that EMIT overestimates the concentration of mycophenolic acid in plasma samples from renal transplant recipients compared with HPLC analysis.
Resumo:
Multilevel converters can achieve an overall effective switch frequency multiplication and consequent ripple reduction through the cancellation of the lowest order switch frequency terms. This paper investigates the harmonic content and the frequency response of these multimodulator converters. It is shown that the transfer function of uniformly sampled modulators is a bessel function associated with the inherent sampling process. Naturally sampled modulators have a flat transfer function, but multiple switchings per switch cycle will occur unless the input is slew-rate limited. Lower sideband harmonics of the effective carrier frequency and, in uniform converters, harmonics of the input signal also limit the useful bandwidth. Observations about the effect of the number of converters, their type (naturally or uniformly sampled), and the ratio of modulating frequency and switch frequency are made.
Resumo:
A sensitive high-performance liquid chromatographic assay has been developed for measuring plasma concentrations of methotrexate and its major metabolite, 7-hydroxymethotrexate. Methotrexate and metabolite were extracted from plasma using solid-phase extraction. An internal standard, aminopterin was used. Chromatographic separation was achieved using a 15-cm poly(styrene-divinylbenzene) (PRP-1(R)) column. This column is more robust than a silica-based stationary phase. Post column, the eluent was irradiated with UV light, producing fluorescent photolytic degradation products of methotrexate and the metabolite. The excitation and emission wavelengths of fluorescence detection were at 350 and 435 nm, respectively. The mobile phase consisted of 0.1 M phosphate buffer (pH 6.5), with 6% N,N-dimethylformamide and 0.2% of 30% hydrogen peroxide. The absolute recoveries for methotrexate and 7-hydroxymethotrexate were greater than 86%. Precision, expressed as a coefficient of variation (n=6), was
Resumo:
In this paper, a solution method is presented to deal with fully coupled problems between medium deformation, pore-fluid flow and heat transfer in fluid-saturated porous media having supercritical Rayleigh numbers. To validate the present solution method, analytical solutions to a benchmark problem are derived for some special cases. After the solution method is validated, a numerical study is carried out to investigate the effects of medium thermoelasticity on high Rayleigh number steady-state heat transfer and mineralization in fluid-saturated media when they are heated from below. The related numerical results have demonstrated that: (1) medium thermoelasticity has a little influence on the overall pattern of convective pore-fluid flow, but it has a considerable effect on the localization of medium deformation, pore-fluid flow, heat transfer and mineralization in a porous medium, especially when the porous medium is comprised of soft rock masses; (2) convective pore-fluid flow plays a very important role in the localization of medium deformation, heat transfer and mineralization in a porous medium. (C) 1999 Elsevier Science S.A. All rights reserved.
Resumo:
A novel three-axis gradient set and RF resonator for orthopedic MRT has been designed and constructed. The set is openable and may be wrapped around injured joints. The design methodology used was the minimization of magnetic field spherical harmonics by simulated annealing. Splitting of the longitudinal coil presents the major design challenge to a fully openable gradient set and in order to efficiently design such coils, we have developed a new fast algorithm for determining the magnetic field spherical harmonics generated by an are of multiturn wire. The algorithm allows a realistic impression of the effect of split longitudinal designs. A prototype set was constructed based on the new designs and tested in a 2-T clinical research system. The set generated 12 mT/m/A with a linear region of 12 cm and a switching time of 100 mu s, conforming closely with theoretical predictions. Preliminary images from the set are presented. (C) 1999 Academic Press.
Resumo:
We describe a strategy for the selection and amplification of foreign gene expression in Chinese hamster ovary (CHO) cells employing a metallothionein gene-containing expression vector. This report describes an amplification procedure that results in an enrichment of clones exhibiting high levels of recombinant protein production and reduces the labour required for screening recombinant cell lines.
Resumo:
An increased degree of utilization of the potential N-glycosylation site In the fourth repeat unit of the human tau protein may be involved in the inability of tau to bind to the corresponding tubulin sequence(s) and in the subsequent development of the paired helical filaments of Alzheimer's disease. To model these processes, we synthesized the octadecapeptide spanning this region without sugar, and with the addition of an N-acetyl-glucosamine moiety. The carbohydrate-protected, glycosylated asparagine was incorporated as a building block during conventional Fmoc-solid phase peptide synthesis. While the crude non-glycosylated analog was obtained as a single peptide, two peptides with, the identical, expected masses, in approximately equal amounts, were detected after the cleavage of the peracetylated glycopeptide. Surprisingly, the two glycopeptides switched positions on the reversed-phase high performance liquid chromatogram after removal of the sugar-protecting acetyl groups. Nuclear magnetic resonance spectroscopy and peptide sequencing identified the more hydrophobic deprotected peak as the target peptide, and the more hydrophilic deprotected peak as a peptide analog in which the aspartic acid-bond just preceding the glycosylated asparagine residue was isomerized resulting in the formation of a beta-peptide. The anomalous chromatographic behavior of the acetylated beta-isomer could be explained on the basis of the generation of an extended hydrophobic surface which is not present in any of the other three glycopeptide variants. Repetition of the syntheses, with altered conditions and reagents, revealed reproducibly high levels of aspartic acid-bond isomerization of the glycopeptide as well as lack of isomerization for the non-glycosylated parent analog. If similar increased aspartic acid-bond isomerization occurs in vivo, a protein modification well known to take place for both the amyloid deposits and the neurofibrillary tangles in Alzheimer's disease, this process may explain the aggregation of glycosylated tau into the paired helical filaments in the affected brains. Copyright (C) 1999 European Peptide Society and John Wiley & Sons, Ltd.
Resumo:
Using the coupled-system approach we calculate the optical spectra of the fluorescence and transmitted fields of a two-level atom driven by a squeezed vacuum of bandwidths smaller than the natural atomic linewidth. We find that in this regime of squeezing bandwidths the spectra exhibit unique features, such as a hole burning and a three-peak structure, which do not appear for a broadband excitation. We show that the features are unique to the quantum nature of the driving squeezed vacuum field and donor appear when the atom is driven by a classically squeezed field. We find that a quantum squeezed-vacuum field produces squeezing in the emitted fluorescence field which appears only in the squeezing spectrum while there is no squeezing in the total field. We also discuss a nonresonant excitation and find that depending on the squeezing bandwidth there is a peak or a hole in the spectrum at a frequency corresponding to a three-wave-mixing process. The hole appears only for a broadband excitation and results from the strong correlations between squeezed-vacuum photons.
Resumo:
Concern about the neurotoxicity of lead, particularly in infants and young children, has led to a revision of blood lead levels which are considered to involve an acceptable level of human exposure. Drinking water guidelines have also been reviewed in order to reduce this source of population exposure to lead. In the last 20 years, guidelines have been reduced from 100 to 50 to 10 mu g/litre. Lead in tap water used to be a major public health problem in Glasgow because of the high prevalence of houses with lead service pipes, the low pH of the public water supply and the resulting high levels of lead in water used for public consumption. Following two separate programmes of water treatment, involving the addition of lime and, a decade later, lime supplemented with orthophosphate, it is considered that maximal measures have been taken to reduce lead exposure by chemical treatment of the water supply. Any residual problem of public exposure would require large scale replacement of lead service pipes. In anticipation of the more stringent limits for lead in drinking water, we set out to measure current lead exposure From tap water in the population of Glasgow served by the Loch Katrine water supply. to compare the current situation with 12 years previously and to assess the public health implications of different limits. The study was based on mothers of young children since maternal blood lead concentrations and the domestic water that mothers use to prepare bottle feeds are the principal sources of foetal and infant lead exposure. An estimated 17% of mothers lived in households with tap water lead concentrations of 10 mu g/litre (the WHO guideline) or above in 1993 compared with 49% in 1981. Mean maternal blood lead concentrations fell by 69% in 12 years. For a given water lead concentration, maternal blood lead concentrations were 67% lower. The mean maternal blood lead concentration was 3.7 mu g/litre in the population at large, compared with 3.3 mu g/litre in households with negligible or absent tap water lead. Nevertheless, between 63% and 76% of cases of mothers with blood lead concentrations of 10 mu g/dl or above were attributable to tap water lead. The study found that maternal blood lead concentrations were well within limits currently considered safe for human health. About 15% of infants may be exposed via bottle feeds to tap water lead concentrations that exceed the WHO guideline of 10 mu g/litre. In the context of the health and social problems which affect the well-being and development of infants and children in Glasgow, however, current levels of lend exposure are considered to present a relatively minor health problem. (C) 2000 Elsevier Science Ltd. All rights reserved.
Resumo:
OBJECTIVE: To evaluate a diagnostic algorithm for pulmonary tuberculosis based on smear microscopy and objective response to trial of antibiotics. SETTING: Adult medical wards, Hlabisa Hospital, South Africa, 1996-1997. METHODS: Adults with chronic chest symptoms and abnormal chest X-ray had sputum examined for Ziehl-Neelsen stained acid-fast bacilli by light microscopy. Those with negative smears were treated with amoxycillin for 5 days and assessed. Those who had not improved were treated with erythromycin for 5 days and reassessed. Response was compared with mycobacterial culture. RESULTS: Of 280 suspects who completed the diagnostic pathway, 160 (57%) had a positive smear, 46 (17%) responded to amoxycillin, 34 (12%) responded to erythromycin and 40 (14%) were treated as smear-negative tuberculosis. The sensitivity (89%) and specificity (84%) of the full algorithm for culture-positive tuberculosis were high. However, 11 patients (positive predictive value [PPV] 95%) were incorrectly diagnosed with tuberculosis, and 24 cases of tuberculosis (negative predictive value [NPV] 70%) were not identified. NPV improved to 75% when anaemia was included as a predictor. Algorithm performance was independent of human immunodeficiency virus status. CONCLUSION: Sputum smear microscopy plus trial of antibiotic algorithm among a selected group of tuberculosis suspects may increase diagnostic accuracy in district hospitals in developing countries.
Resumo:
Objective: To measure prevalence and model incidence of HIV infection. Setting: 2013 consecutive pregnant women attending public sector antenatal clinics in 1997 in Hlabisa health district, South Africa. Historical seroprevalence data, 1992-1995. Methods: Serum remaining from syphilis testing was tested anonymously for antibodies to HIV to determine seroprevalence. Two models, allowing for differential mortality between HIV-positive and HIV-negative people, were used. The first used serial seroprevalence data to estimate trends in annual incidence. The second, a maximum likelihood model, took account of changing force of infection and age-dependent risk of infection, to estimate age-specific HIV incidence in 1997. Multiple logistic regression provided adjusted odds ratios (OR) for risk factors for prevalent HIV infection. Results: Estimated annual HIV incidence increased from 4% in 1992/1993 to 10% in 1996/1997. In 1997, highest age-specific incidence was 16% among women aged between 20 and 24 years. in 1997, overall prevalence was 26% (95% confidence interval [CI], 24%-28%) and at 34% was highest among women aged between 20 and 24 years. Young age (<30 years; odds ratio [OR], 2.1; p = .001), unmarried status (OR 2.2; p = .001) and living in less remote parts of the district (OR 1.5; p = .002) were associated with HIV prevalence in univariate analysis. Associations were less strong in multivariate analysis. Partner's migration status was not associated with HIV infection. Substantial heterogeneity of HIV prevalence by clinic was observed (range 17%-31%; test for trend, p = .001). Conclusions: This community is experiencing an explosive HIV epidemic. Young, single women in the more developed parts of the district would form an appropriate cohort to test, and benefit from, interventions such as vaginal microbicides and HIV vaccines.
Resumo:
We propose a single optical photon source for quantum cryptography based on the acoustoelectric effect. Surface acoustic waves (SAWs) propagating through a quasi-one-dimensional channel have been shown to produce packets of electrons that reside in the SAW minima and travel at the velocity of sound. In our scheme, the electron packets are injected into a p-type region, resulting in photon emission. Since the number of electrons in each packet can be controlled down to a single electron, a stream of single- (or N-) photon states, with a creation time strongly correlated with the driving acoustic field, should be generated.
Resumo:
The measurement of organic carbon in soils has traditionally used dichromate oxidation procedures including the Wakley and Black and the Heanes methods. The measurement of carbon in soils by high temperature combustion is now widely used providing a rapid automated procedure without the use of toxic chemicals. This procedure however measures total carbon thus requiring some means of correction for soil samples containing carbonate and charcoal forms of carbon. This paper examines the effects of known additions of charcoal to a range of soil types on the results obtained by the Walkley and Black, Heanes and combustion methods. The results show, that while the charcoal carbon does not react under Walkley and Black conditions, some proportion does so with the Heanes method. A comparison of six Australian Soil and Plant Analysis Council reference soil samples by the three methods showed good agreement between the Heanes method, the combustion method and only slightly lower recoveries by the Walkley and Black procedure. Carbonate carbon will cause an overestimation of soil organic carbon by the combustion method thus requiring a separate determination of carbonate carbon to be applied as a correction. This work shows that a suitable acid pre-treatment of alkaline soils in the sample boats followed by a drying step eliminates the carbonate carbon prior to combustion and the need for an additional measurement. The measurement of carbon in soils by high temperature combustion in an oxygen atmosphere has been shown to be a rapid and reliable method capable of producing results in good agreement with one of the established dichromate oxidation procedures.
Resumo:
To facilitate the investigation of free mycophenolic acid concentrations we developed a high-performance liquid chromatography tandem mass spectrometry method using indomethacin as an internal standard. Free drug was isolated from plasma samples (500 mul) using ultrafiltration, The analytes were extracted from the ultrafiltrate (200 mul) using C-18 solid-phase extraction. Detection was by selected reactant monitoring of mycophenolic acid (m/z 318.9-->190.9) and the internal standard (m/z 356.0-->297.1) with an atmospheric pressure chemical ionisation interface. The total chromatographic analysis time was 12 min. The method was found to be linear over the range investigated, 2.5-200 mug/l (r>0.990, n=6). The relative recovery of the method for the control samples studied (7.5, 40.0 and 150 mug/l) ranged from 95 to 104%. The imprecision of the method, expressed in terms of intra- and inter-day coefficients of variation, was