Determination of pindolol enantiomers in human plasma and urine by simple liquid-liquid extraction and high-performance liquid chromatography


Autoria(s): Beal, J. L.; Tett, S. E.
Data(s)

01/01/1998

Resumo

A simple method for the measurement of pindolol enantiomers by HPLC is presented. Alkalinized serum or urine is extracted with ethyl acetate and the residue remaining after evaporation of the organic layer is then derivatised with (S)-(-)-alpha-methylbenzyl isocyanate. The diastereoisomers of derivatised pindolol and metoprolol (internal standard) are separated by high-performance liquid chromatography (HPLC) using a C-18 silica column and detected using fluorescence (excitation lambda: 215 nm, emission lambda: 320 nm). The assay displays reproducible linearity for pindolol enantiomers with a correlation coefficient of r(2) greater than or equal to 0.998 over the concentration range 8-100 ng ml(-1) for plasma and 0.1-2.5 mu g ml(-1) for urine. The coefficient of variation for accuracy and precision of the quality control samples for both plasma and urine are consistently

Identificador

http://espace.library.uq.edu.au/view/UQ:35150

Idioma(s)

eng

Publicador

Elsevier.

Palavras-Chave #Biochemical Research Methods #Chemistry, Analytical #Enantiomer Separation #Pindolol #Blocking-agents #Beta-blockers #Sotalol #Column #320300 Medical Biochemistry and Clinical Chemistry #250401 Separation Science
Tipo

Journal Article