784 resultados para hardness measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to invert the ionospheric electron density profile from Riometer (Relative Ionospheric opacity meter) measurement. The newly Riometer instrument KAIRA (Kilpisjärvi Atmospheric Imaging Receiver Array) is used to measure the cosmic HF radio noise absorption that taking place in the D-region ionosphere between 50 to 90 km. In order to invert the electron density profile synthetic data is used to feed the unknown parameter Neq using spline height method, which works by taking electron density profile at different altitude. Moreover, smoothing prior method also used to sample from the posterior distribution by truncating the prior covariance matrix. The smoothing profile approach makes the problem easier to find the posterior using MCMC (Markov Chain Monte Carlo) method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several methods have been described to measure intraocular pressure (IOP) in clinical and research situations. However, the measurement of time varying IOP with high accuracy, mainly in situations that alter corneal properties, has not been reported until now. The present report describes a computerized system capable of recording the transitory variability of IOP, which is sufficiently sensitive to reliably measure ocular pulse peak-to-peak values. We also describe its characteristics and discuss its applicability to research and clinical studies. The device consists of a pressure transducer, a signal conditioning unit and an analog-to-digital converter coupled to a video acquisition board. A modified Cairns trabeculectomy was performed in 9 Oryctolagus cuniculus rabbits to obtain changes in IOP decay parameters and to evaluate the utility and sensitivity of the recording system. The device was effective for the study of kinetic parameters of IOP, such as decay pattern and ocular pulse waves due to cardiac and respiratory cycle rhythm. In addition, there was a significant increase of IOP versus time curve derivative when pre- and post-trabeculectomy recordings were compared. The present procedure excludes corneal thickness and error related to individual operator ability. Clinical complications due to saline infusion and pressure overload were not observed during biomicroscopic evaluation. Among the disadvantages of the procedure are the requirement of anesthesia and the use in acute recordings rather than chronic protocols. Finally, the method described may provide a reliable alternative for the study of ocular pressure dynamic alterations in man and may facilitate the investigation of the pathogenesis of glaucoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Significant improvements have been noted in heart transplantation with the advent of cyclosporine. However, cyclosporine use is associated with significant side effects, such as chronic renal failure. We were interested in evaluating the incidence of long-term renal dysfunction in heart transplant recipients. Fifty-three heart transplant recipients were enrolled in the study. Forty-three patients completed the entire evaluation and follow-up. Glomerular (serum creatinine, creatinine clearance measured, and creatinine clearance calculated) and tubular functions (urinary retinol-binding protein, uRBP) were re-analyzed after 18 months. At the enrollment time, the prevalence of renal failure ranged from 37.7 to 54% according to criteria used to define it (serum creatinine > or = 1.5 mg/dL and creatinine clearance <60 mL/min). Mean serum creatinine was 1.61 ± 1.31 mg/dL (range 0.7 to 9.8 mg/dL) and calculated and measured creatinine clearances were 67.7 ± 25.9 and 61.18 ± 25.04 mL min-1 (1.73 m²)-1, respectively. Sixteen of the 43 patients who completed the follow-up (37.2%) had tubular dysfunction detected by increased levels of uRBP (median 1.06, 0.412-6.396 mg/dL). Eleven of the 16 patients (68.7%) with elevated uRBP had poorer renal function after 18 months of follow-up, compared with only eight of the 27 patients (29.6%) with normal uRBP (RR = 3.47, P = 0.0095). Interestingly, cyclosporine trough levels were not different between patients with or without tubular and glomerular dysfunction. Renal function impairment is common after heart transplantation. Tubular dysfunction, assessed by uRBP, correlates with a worsening of glomerular filtration and can be a useful tool for early detection of renal dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this research – which is to critically analyze current theories and methods of intangible assets evaluation and potentially develop and test new methodology based on the practical example(s) in the IT industry. Having this goal in mind the main research questions in this paper will be: What are advantages and disadvantages of the current practices of measurement intellectual capital or valuation of intangible assets? How to properly measure intellectual capital in IT? Resulting method exhibits a new unique approach to the IC measurement and potentially even larger field of application. Despite the fact that in this particular research, I focused my attention on IT (Software and Internet services cluster – to be exact), the logic behind the method is applicable within any industry since the method is designed to be fully compliant with measurement theory and thus can be properly scaled for any application. Building a new method is a difficult and iterative process: in the current iteration the method stands out as rather a theoretical concept rather than a business tool, however even current concept totally fulfills its purpose as a benchmarking tool for measuring intellectual capital in IT industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel, rapid and cost-effective trifluoperazine dihydrochloride (TFPH) decolorization assay is described for the screening of antioxidant activity. A chromogenic reaction between TFPH and potassium persulfate at low pH produces an orange-red radical cation with maximum absorption at 502 nm in its first-order derivative spectrum. TFPH was dissolved in distilled water to give a 100 mM solution. The TFPH radical cation solution was made by reacting 0.5 mL of the solution with K2S2O8 (final concentration: 0.1 mM) and diluting to 100 mL with 4 M H2SO4 solution. A linear inhibition of color production was observed with linearly increasing amounts of antioxidants, with correlation coefficients (R²) ranging from 0.999 to 0.983. The antioxidant capacity of standard solutions of an antioxidant was evaluated by comparing with the inhibition curve using Trolox as the standard. Comparison of antioxidant capacity determined with this newly developed TFPH assay and with the well-known 2,2'-azinobis-[3-ethylbenzthiazoline-6-sulfonic acid] (ABTS)-persulfate decolorization assay indicated the efficacy and sensitivity of the procedure. The proposed assay is less expensive (costs about US$4 per 100 assays) and requires only 20 min for preparation of radical cation solution in comparison with ABTS assay, in which almost 12-16 h are required for preparation of a stable ABTS radical cation solution. The present assay has the advantage over ABTS assay that it can be used to measure the antioxidant activity of the samples, which are naturally found at a pH as low as 1, because the radical cation itself has been stabilized at low pH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phosphatidylserine (PS) exposure occurs during the cell death program and fluorescein-labeled lactadherin permits the detection of PS exposure earlier than annexin V in suspended cell lines. Adherent cell lines were studied for this apoptosis-associated phenomenon to determine if PS probing methods are reliable because specific membrane damage may occur during harvesting. Apoptosis was induced in the human tongue squamous carcinoma cell line (Tca8113) and the adenoid cystic carcinoma cell line (ACC-2) by arsenic trioxide. Cells were harvested with a modified procedure and labeled with lactadherin and/or annexin V. PS exposure was localized by confocal microscopy and apoptosis was quantified by flow cytometry. The detachment procedure without trypsinization did not induce cell damage. In competition binding experiments, phospholipid vesicles competed for more than 95 and 90% of lactadherin but only about 75 and 70% of annexin V binding to Tca8113 and ACC-2 cells. These data indicate that PS exposure occurs in three stages during the cell death program and that fluorescein-labeled lactadherin permitted the detection of early PS exposure. A similar pattern of PS exposure has been observed in two malignant cell lines with different adherence, suggesting that this pattern of PS exposure is common in adherent cells. Both lactadherin and annexin V could be used in adherent Tca8113 and ACC-2 cell lines when an appropriate harvesting procedure was used. Lactadherin is more sensitive than annexin V for the detection of PS exposure as the physical structure of PS in these blebs and condensed apoptotic cell surface may be more conducive to binding lactadherin than annexin V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Caco-2 cell line has been used as a model to predict the in vitro permeability of the human intestinal barrier. The predictive potential of the assay relies on an appropriate in-house validation of the method. The objective of the present study was to develop a single HPLC-UV method for the identification and quantitation of marker drugs and to determine the suitability of the Caco-2 cell permeability assay. A simple chromatographic method was developed for the simultaneous determination of both passively (propranolol, carbamazepine, acyclovir, and hydrochlorothiazide) and actively transported drugs (vinblastine and verapamil). Separation was achieved on a C18 column with step-gradient elution (acetonitrile and aqueous solution of ammonium acetate, pH 3.0) at a flow rate of 1.0 mL/min and UV detection at 275 nm during the total run time of 35 min. The method was validated and found to be specific, linear, precise, and accurate. This chromatographic system can be readily used on a routine basis and its utilization can be extended to other permeability models. The results obtained in the Caco-2 bi-directional transport experiments confirmed the validity of the assay, given that high and low permeability profiles were identified, and P-glycoprotein functionality was established.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous assessment of verticality by means of rod and rod and frame tests indicated that human subjects can be more (field dependent) or less (field independent) influenced by a frame placed around a tilted rod. In the present study we propose a new approach to these tests. The judgment of visual verticality (rod test) was evaluated in 50 young subjects (28 males, ranging in age from 20 to 27 years) by randomly projecting a luminous rod tilted between -18 and +18° (negative values indicating left tilts) onto a tangent screen. In the rod and frame test the rod was displayed within a luminous fixed frame tilted at +18 or -18°. Subjects were instructed to verbally indicate the rod’s inclination direction (forced choice). Visual dependency was estimated by means of a Visual Index calculated from rod and rod and frame test values. Based on this index, volunteers were classified as field dependent, intermediate and field independent. A fourth category was created within the field-independent subjects for whom the amount of correct guesses in the rod and frame test exceeded that of the rod test, thus indicating improved performance when a surrounding frame was present. In conclusion, the combined use of subjective visual vertical and the rod and frame test provides a specific and reliable form of evaluation of verticality in healthy subjects and might be of use to probe changes in brain function after central or peripheral lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although 17β-estradiol (E2) deficiency has been linked to the development of osteoarthritis (OA) in middle-aged women, there are few studies relating other estrogens and estrogen metabolites (EMs) to this condition. We developed a high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) method to measure the levels of six EMs (i.e., estrone, E2, estriol, 2-hydroxyestrone, 2-hydroxyestradiol, and 16a-hydroxyestrone) in healthy pre- and postmenopausal women and women with OA. This method had a precision ranging from 1.1 to 3.1% and a detection limit ranging from 10 to 15 pg. Compared to healthy women, serum-free E2 was lower in the luteal and postmenopausal phases in women with OA, and total serum E2 was lower in postmenopausal women with OA. Moreover, compared to healthy women, total serum 2-hydroxyestradiol was higher in postmenopausal women with OA and total serum 2-hydroxyestrone was lower in both the luteal and follicular phases in women with OA. In conclusion, our HPLC-ESI-MS/MS method allowed the measurement of multiple biochemical targets in a single assay, and, given its increased cost-effectiveness, simplicity, and speed relative to previous methods, this method is suitable for clinical studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis the basic structure and operational principals of single- and multi-junction solar cells are considered and discussed. Main properties and characteristics of solar cells are briefly described. Modified equipment for measuring the quantum efficiency for multi-junction solar cell is presented. Results of experimental research single- and multi-junction solar cells are described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The power is still today an issue in wearable computing applications. The aim of the present paper is to raise awareness of the power consumption of wearable computing devices in specific scenarios to be able in the future to design energy efficient wireless sensors for context recognition in wearable computing applications. The approach is based on a hardware study. The objective of this paper is to analyze and compare the total power consumption of three representative wearable computing devices in realistic scenarios such as Display, Speaker, Camera and microphone, Transfer by Wi-Fi, Monitoring outdoor physical activity and Pedometer. A scenario based energy model is also developed. The Samsung Galaxy Nexus I9250 smartphone, the Vuzix M100 Smart Glasses and the SimValley Smartwatch AW-420.RX are the three devices representative of their form factors. The power consumption is measured using PowerTutor, an android energy profiler application with logging option and using unknown parameters so it is adjusted with the USB meter. The result shows that the screen size is the main parameter influencing the power consumption. The power consumption for an identical scenario varies depending on the wearable devices meaning that others components, parameters or processes might impact on the power consumption and further study is needed to explain these variations. This paper also shows that different inputs (touchscreen is more efficient than buttons controls) and outputs (speaker sensor is more efficient than display sensor) impact the energy consumption in different way. This paper gives recommendations to reduce the energy consumption in healthcare wearable computing application using the energy model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The value that the customer perceives from a supplier’s offering, impacts customer’s decision making and willingness to pay at the time of the purchase, and the overall satisfaction. Thus, for a business supplier, it is critical to understand their customers’ value perceptions. The objective of this thesis is to understand what measurement and monitoring system customers value, by examining their key purchasing criteria and perceived benefits. Theoretical part of this study consists on reviewing relevant literature on organizational buying behavior and customer perceived value. This study employs a qualitative interview research method. The empirical part of this research consisted of conducting 20 in-depth interviews with life science customers in USA and in Europe. Quality and technical features are the most important purchasing criteria, while product-related benefits seem to be the most important perceived benefits. At the marketing of the system, the emphasis should be at which regulations the system complies with, references of supplier’s prior experience, the reliability and usability of the system, and total costs. The benefits that should be emphasized are the better control of customer’s process, and the proof of customer’s product quality

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, technological advancements in microelectronics and sensor technologies have revolutionized the field of electrical engineering. New manufacturing techniques have enabled a higher level of integration that has combined sensors and electronics into compact and inexpensive systems. Previously, the challenge in measurements was to understand the operation of the electronics and sensors, but this has now changed. Nowadays, the challenge in measurement instrumentation lies in mastering the whole system, not just the electronics. To address this issue, this doctoral dissertation studies whether it would be beneficial to consider a measurement system as a whole from the physical phenomena to the digital recording device, where each piece of the measurement system affects the system performance, rather than as a system consisting of small independent parts such as a sensor or an amplifier that could be designed separately. The objective of this doctoral dissertation is to describe in depth the development of the measurement system taking into account the challenges caused by the electrical and mechanical requirements and the measurement environment. The work is done as an empirical case study in two example applications that are both intended for scientific studies. The cases are a light sensitive biological sensor used in imaging and a gas electron multiplier detector for particle physics. The study showed that in these two cases there were a number of different parts of the measurement system that interacted with each other. Without considering these interactions, the reliability of the measurement may be compromised, which may lead to wrong conclusions about the measurement. For this reason it is beneficial to conceptualize the measurement system as a whole from the physical phenomena to the digital recording device where each piece of the measurement system affects the system performance. The results work as examples of how a measurement system can be successfully constructed to support a study of sensors and electronics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main goal of this master’s thesis was to find out, how to improve customer experience management and measurement. This study is a qualitative case study, in which the data collection method has been interviews. In addition, some of the company’s customer experience measurement methods have been analyzed. The theoretical background is applied in practice by interviewing 5 representatives from the case company. In the case company, the management has launched a customer experience focused program, and given guidelines for customer experience improvement. In the case company, customer experience is measured with different methods, one example is asking the recommendation readiness from a customer. In order to improve the customer experience management, the case company should define, what the company means with customer experience and what kind of customer experience the company is aiming to create. After the encounter, the customer should be left with feelings of satisfaction, positivity and trust. The company should focus on easiness in its processes, on top of which the processes should work fluently. The customer experience management should be improved through systematic planning, and by combining and standardizing different measures. In addition, some channel-based measures should be used. The measurement conducted should be more customer focused, and the case company should form an understanding, which touch points are the most relevant to measure.