877 resultados para Stationary
Resumo:
The emergence of chirality in enantioselective autocatalysis for compounds unable to transform according to the Frank-like reaction network is discussed with respect to the controversial limited enantioselectivity (LES) model composed of coupled enantioselective and non-enantioselective autocatalyses. The LES model cannot lead to spontaneous mirror symmetry breaking (SMSB) either in closed systems with a homogeneous temperature distribution or in closed systems with a stationary non-uniform temperature distribution. However, simulations of chemical kinetics in a two-compartment model demonstrate that SMSB may occur if both autocatalytic reactions are spatially separated at different temperatures in different compartments but coupled under the action of a continuous internal flow. In such conditions, the system can evolve, for certain reaction and system parameters, toward a chiral stationary state; that is, the system is able to reach a bifurcation point leading to SMSB. Numerical simulations in which reasonable chemical parameters have been used suggest that an adequate scenario for such a SMSB would be that of abyssal hydrothermal vents, by virtue of the typical temperature gradients found there and the role of inorganic solids mediating chemical reactions in an enzyme-like role.
Resumo:
Enantiomeerit ovat yhdisteitä, jotka ovat toistensa peilikuvamuotoja. Enantiomeerien erotusmenetelmiä ovat neste-nesteuutto, kalvotekniikka, kiteytys, kromatografia ja kapillaarielektroforeesi. Nestekromatografinen erotus perustuu joko suoraan erotukseen tai epäsuoraan erotukseen. Kiraaliset stationaarifaasit erottavat yhdisteet kolonnissa suoralla erotuksella. Derivoimattomia aminohappojen enantiomeerejä on erotettu käyttäen ligandinvaihto-, kruunueetteri-, antibiootti- ja polysakkaridistationaarifaaseja. Epäsuora erotus vaatii erotettavan enantiomeeriparin esikäsittelyn ennen kolonnia. Markkinoilta löytyy niukasti preparatiiviseen mittakaavaan soveltuvia enantiomeerien erotusmateriaaleja. Työn kokeellisessa osassa enantiomeerien erotuksia tehtiin sekä analyyttisessä mittakaavassa että preparatiivisessa mittakaavassa. Tutkittavina pääkomponentteina aminohapoista olivat metioniinin, proliinin ja seriinin enantiomeeriparit. Analyyttisessä mittakaavassa kuparimuotoisella ligandinvaihtokolonnilla tehty erotus onnistui erittäin hyvin. Piikkien resoluutioiden arvot vaihtelivat tyypillisesti välillä 2,0-35 ja erotustekijöiden arvot välillä 1,5-30. Parhaiten onnistuttiin erottamaan metioniinin enantiomeerit toisistaan. Prepatatiivisen mittakaavan erotusmateriaalin tutkimus keskittyi materiaalin kokeiluun ja kehitykseen aminohappojen enantiomeerien erotukseen soveltuvaksi. Erotusmateriaalilla onnistuttiin erottamaan aminohappoja toisistaan, mutta aminohappojen enantiomeerien erottumista ei onnistuttu selkeästi havaitsemaan. Erotusmateriaali toimi parhaiten muunnettuna alkaalisissa olosuhteissa kuparimuotoiseksi. Kuparin pysymättömyys erotusmateriaalissa aiheutti kuitenkin ongelmia kokeiden toistettavuuteen.
Resumo:
Alikriittisellä vedellä tarkoitetaan paineistettua vettä, joka on kriittisen lämpötilansa (374 °C) alapuolella nestemäisessä tilassa. Veden tiheys pienenee lämpötilan kasvaessa Veden liuotinominaisuuksia voidaan säädellä lämpötilan avulla. Veden pintajännitys, viskositeetti, tiheys ja polaarisuus pienenevät lämpötilan kasvaessa, ja alikriittisen veden aineominaisuudet muuttuvat lähemmäksi orgaanista liuotinta. Alikriittisen veden dielektrisyysvakion aleneminen johtuu pääasiassa lämpötilan vaikutuksesta ja vain vähän paineen vaikutuksesta. Alikriittistä vettä on käytetty liuottimena uutossa, mutta nyt myös alikriittinen kromatografia on kehittymässä oleva erotusmenetelmä. Työn kokeellisessa osassa kehitettiin kromatografinen laitteisto alikriittiselle vedelle, jolla tutkittiin sokerialkoholien ja sokerien kromatografista erotusta alikriittisen veden avulla. Lisäksi tutkittiin sokerialkoholien, sokereiden ja stationäärifaasien termistä kestävyyttä. Tutkittavina komponentteina olivat sorbitoli, mannitoli, ksylitoli, arabinoosi, mannoosi, ksyloosi, maltoosi ja ramnoosi. Stationäärifaaseina käytettiin makrohuokoista funktionalisoimatonta polystyreenidivinyylibentseenikopolymeeriä, sekä vahvoja ja heikkoja divinyylibentseenillä ristisilloitettuja kationinvaihtohartseja, jotka olivat joko Na+- tai Ca2+-ionimuodoissa. Veden lämpötilan nostaminen vaikuttaa sekä kromatografisen stationäärifaasin tilavuusmuutoksiin että näytekomponenttien ominaisuuksiin. Vahvoilla kationinvaihtimilla havaittiin termisten tilavuusmuutosten riippuvan ionimuodosta: Na+-muotoiset hartsit turpoavat ja Ca2+-muotoiset kutistuvat lämpötilan noustessa. Heikot kationinvaihtimet kutistuvat molemmissa ionimuodoissa, mutta Ca2+-muoto kutistuu Na+-muotoa voimakkaammin. Näytekomponenteista sokerialkoholien havaittiin kestävän paremmin korkeita lämpötiloja kuin sokerien. Sokerialkoholeista kestävimmäksi havaittiin ksylitoli ja sokereista ramnoosi. Tutkittavien komponenttien piikkien havaittiin kapenevan, häntimisen vähenevän, ja piikkien eluoituvan aikaisemmin riippuen käytettävästä stationäärifaasista. Ca2+-muotoisen vahvan kationinvaihtimen kompleksinmuodostuskyky heikkeni lämpötilan kasvaessa. Näytekomponenttien erotus ei kuitenkaan parantunut lämpötilan noustessa tutkituilla stationäärifaaseilla.
Resumo:
Neljännen sukupolven mobiiliverkot yhdistävät saumattomasti televerkot, Internetin ja niiden palvelut. Alkuperin Internetiä käytettiin vain paikallaan pysyviltä tietokoneilta perinteisten televerkkojen tarjotessa puhelin- ja datapalveluita. Neljännen sukupolven mobiiliverkkojen käyttäjät voivat käyttää sekä Internetiin perustuvia että perinteisten televerkkojen palveluita liikkuessaankin. Tämä diplomityö esittelee neljännen sukupolven mobiiliverkon yleisen arkkitehtuurin. Arkkitehtuurin perusosat kuvaillaan ja arkkitehtuuria verrataan toisen ja kolmannen sukupolven mobiiliverkkoihin. Aiheeseen liittyvät Internet-standardit esitellään ja niiden soveltuvuutta mobiiliverkkoihin pohditaan. Langattomia, lyhyen kantaman nopeita liitäntäverkkotekniikoita esitellään. Neljännen sukupolven mobiiliverkoissa tarvittavia päätelaitteiden ja käyttäjien liikkuvuuden hallintamenetelmiä esitellään. Esitelty arkkitehtuuri perustuu langattomiin, lyhyen kantaman nopeisiin liitäntäverkkotekniikoihin ja Internet-standardeihin. Arkkitehtuuri mahdollistaa yhteydet toisiin käyttäjiin ilman tietoa heidän senhetkisestä päätelaitteesta tai sijainnista. Internetin palveluitavoidaan käyttää missä tahansa neljännen sukupolven mobiiliverkon alueella. Yleiskäytöistä liikkuvuuden hallintamenetelmää yhden verkon alueelle ehdotetaan. Menetelmää voidaan käyttää yhdessä esitellyn arkkitehtuurin kanssa.
Resumo:
Työssä tutkittiin kahden silikapohjaisen erotusmateriaalin soveltuvuutta nikkelin ja koboltin poistoon sinkkisulfaattiliuoksista. Suurin osa kokeista tehtiin ioninvaihtimella, jonka funktionaalinen ryhmä on iminodietikkahappo. Vertailuerotusmateriaalin toiminta perustui adsorptioon. Liuoksina käytettiin sekä autenttista prosessiliuosta että synteettistä ZnSO4-liousta. Ioninvaihtimen kestävyyskokeissa selvisi, että tutkittu ioninvaihdin kestää hyvin sekä 60 oC lämpötilan että happamia olosuhteita. Emäksisissä liuoksissa silikarunko ei kestä. Jo 0,1 M NaOH-liuos liuottaa merkittävästi hartsia vuorokauden aikana. Vaihtimen vetyionikapasiteetiksi saatiin titrauksella 2,3 mekv/g. Tasapainokokeilla saatiin selville, että ioninvaihdin on selektiivinen nikkelille sinkin suhteen ja että selektiivisyys kasvaa liuoksen pH:n laskiessa. Koboltille ioninvaihdin ei ole selektiivinen sinkin suhteen. Mikäli sinkin pitoisuus on tuhansia kertoja nikkelin pitoisuutta suurempi, ei ioninvaihtimen Ni-selektiivisyys riitä myöskään nikkelille. Synteettisillä ZnSO4-liuoksilla tehtyjen kolonnikokeiden perusteella havaittiin, että tutkitulla ioninvaihtimella voidaan laimeista ZnSO4-liuoksista poistaa nikkeliä selektiivisesti. Nikkelin eluointi onnistui helposti 1 M H2SO4:lla. Vertailukokeen perusteella oli ioninvaihtimen Ni/Zn-selektiivisyys referenssiadsorbentin Ni/Zn-selektiivisyyttä pienempi. Ioninvaihtokolonnin mallintaminen ei onnistunut riittävän hyvin kuvaamaan ioninvaihtimessa tapahtuvaa samanaikaista ioninvaihtoa ja adsorptiota. Sen sijaan kun kolonnissa oli vertailumateriaalina käytetty adsorbentti, saatiin kolonnikokeiden tulokset mallilla hyvin ennustettua.
Resumo:
Teollisessa kromatografiassa kolonnia pyritään kuormittamaan mahdollisimman paljon, jotta saataisiin maksimoitua erotetun komponentin määrä aikayksikköä kohden. Tässä työssä kuormitusta tutkittiin nostamalla syöttöliuoksen, synteettisen melassin, näyteväkevyyttä 80-125 ºC:ssa. Eluenttina oli paineistettu kuumaa vesi ja hartsina vahva Na-muotoinen PS-DVB pohjainen vahva kationinvaihtohartsi. Lämpötilaa nostamalla piikit kapenivat ja tulivat symmetrisemmiksi, erotus nopeutui sekä suola erottui usein paremmin sokereista. Syöttöliuoksen kuiva-ainetta lisättiin asteittain 55 p-% saakka, jolloin ei vielä havaittu ongelmia erotuksessa. Lämpötilassa 125 ºC havaittiin erotuksen aikana kuormituksesta riippumatonta sakkaroosin invertoitumista. Vertailtaessa eri stationäärifaaseja havaittiin Na-muotoisen PS-DVB pohjaisen kationinvaihtohartsin erottavan yleensä sokereita, sokerialkoholeja, oligosakkarideja ja betaiinia lähes poikkeuksetta paremmin alhaisilla pitoisuuksilla kuin neutraalihartsi ja Na-muotoinen zeoliitti. Erottuminen ei yleensä parantunut lämpötilaa nostamalla, mutta piikit kapenivat ja erotus nopeutui. Monosakkaridien erotus huononi 125 ºC:ssa kationinvaihtohartsilla. Tutkittaessa terveysvaikutteisten ksylo-oligosakkaridien soveltuvuutta alikriittiseen erotukseen, niiden havaittiin huomattavasti hydrolysoituvan happamissa olosuhteissa koeputkessa 100 ºC:ssa kahdessa tunnissa. Näytteessä olevien epäpuhtauksien havaittiin katalysoineen hydrolyysiä. Hydrolysoituminen oli hitaampaa neutraaleissa olosuhteissa korotetussa lämpötilassa. Tästä voitiin tehdä johtopäätös, että alikriittiset olosuhteet eivät sovi ksylo-oligosakkaridien erotukseen.
Resumo:
Polymeeriadsorbentteja valmistetaan silloittamalla styreeniä, akrylaattia tai fenoliformaldehydiä. Useimmiten ristisilloittajana toimii divinyylibentseeni. Polymeeriadsorbenteissa ei itsessään ole ioninvaihtoryhmiä, joten ne sopivat ionittomien ja heikosti ionisoitujen aineiden adsorptioon. Usein polymeeriadsorbentteja käytetään vaihtoehtona aktiivihiilelle eri sovelluksissa. Työn kirjallisuusosassa on katsaus polymeeriadsorbenttien sovelluksiin lähinnä elintarviketeollisuudessa. Lisäksi siinä selvitetään polymeeriadsorbenttien rakennetta ja synteesimenetelmiä. Kokeellisessa osassa tutkittiin valittujen styreeni- ja akrylaattipohjaisten polymeeriadsorbenttien soveltuvuutta kromatografisen erotuksen stationaarifaasiksi. Kromatografia-ajoissa käytettiin eluenttina vettä, jonka lämpötila oli pääasiassa joko 75 tai 125 °C. Jälkimmäisessä lämpötilassa vesi on paineistettua neste, jota kutsutaan myös alikriittiseksi vedeksi. Malliaineina oli eri sokereita, aminohappoja sekä bentsoehappoa ja bentsyylialkoholia. Kromatografisen soveltuvuuden lisäksi selvitettiin adsorbenttien termistä kestävyyttä ja rakennetta. Termisesti polymeeriadsorbentit kestivät hyvin lämpötiloja 125 °C:eseen saakka. Polymeeriadsorbenteilla, joilla on suuri ominaispinta-ala, on myös suuri adsorptiokapasiteetti. Styreenipohjaiset adsorbentit erottivat kaikkia tutkittuja malliaineita akrylaattipohjaisia paremmin. Jotkut adsorbentit eivät erottaneet mitään tutkituista yhdisteistä. Lämpötilan nostaminen kavensi piikkejä ja nopeutti malliaineiden retentoitumista, mutta ei parantanut erottumista.
Resumo:
In this paper we consider a stochastic process that may experience random reset events which suddenly bring the system to the starting value and analyze the relevant statistical magnitudes. We focus our attention on monotonic continuous-time random walks with a constant drift: The process increases between the reset events, either by the effect of the random jumps, or by the action of the deterministic drift. As a result of all these combined factors interesting properties emerge, like the existence (for any drift strength) of a stationary transition probability density function, or the faculty of the model to reproduce power-law-like behavior. General formulas for two extreme statistics, the survival probability, and the mean exit time, are also derived. To corroborate in an independent way the results of the paper, Monte Carlo methods were used. These numerical estimations are in full agreement with the analytical predictions.
Resumo:
It is axiomatic that our planet is extensively inhabited by diverse micro-organisms such as bacteria, yet the absolute diversity of different bacterial species is widely held to be unknown. Different bacteria can be found from the depths of the oceans to the top of the mountains; even the air is more or less colonized by bacteria. Most bacteria are either harmless or even advantageous to human beings but there are also bacteria, which can cause severe infectious diseases or spoil the supplies intended for human consumption. Therefore, it is vitally important not only to be able to detect and enumerate bacteria but also to assess their viability and possible harmfulness. Whilst the growth of bacteria is remarkably fast under optimum conditions and easy to detect by cultural methods, most bacteria are believed to lie in stationary phase of growth in which the actual growth is ceased and thus bacteria may simply be undetectable by cultural techniques. Additionally, several injurious factors such as low and high temperature or deficiency of nutrients can turn bacteria into a viable but non-culturable state (VBNC) that cannot be detected by cultural methods. Thereby, various noncultural techniques developed for the assessment of bacterial viability and killing have widely been exploited in modern microbiology. However, only a few methods are suitable for kinetic measurements, which enable the real-time detection of bacterial growth and viability. The present study describes alternative methods for measuring bacterial viability and killing as well as detecting the effects of various antimicrobial agents on bacteria on a real-time basis. The suitability of bacterial (lux) and beetle (luc) luciferases as well as green fluorescent protein (GFP) to act as a marker of bacterial viability and cell growth was tested. In particular, a multiparameter microplate assay based on GFP-luciferase combination as well as a flow cytometric measurement based on GFP-PI combination were developed to perform divergent viability analyses. The results obtained suggest that the antimicrobial activities of various drugs against bacteria could be successfully measured using both of these methods. Specifically, the data reliability of flow cytometric viability analysis was notably improved as GFP was utilized in the assay. A fluoro-luminometric microplate assay enabled kinetic measurements, which significantly improved and accelerated the assessment of bacterial viability compared to more conventional viability assays such as plate counting. Moreover, the multiparameter assay made simultaneous detection of GFP fluorescence and luciferase bioluminescence possible and provided extensive information about multiple cellular parameters in single assay, thereby increasing the accuracy of the assessment of the kinetics of antimicrobial activities on target bacteria.
Resumo:
Networks often represent systems that do not have a long history of study in traditional fields of physics; albeit, there are some notable exceptions, such as energy landscapes and quantum gravity. Here, we consider networks that naturally arise in cosmology. Nodes in these networks are stationary observers uniformly distributed in an expanding open Friedmann-Lemaitre-Robertson-Walker universe with any scale factor and two observers are connected if one can causally influence the other. We show that these networks are growing Lorentz-invariant graphs with power-law distributions of node degrees. These networks encode maximum information about the observable universe available to a given observer.
Resumo:
Reversed phase liquid chromatography (RPLC) coupled to mass spectrometry (MS) is the gold standard technique in bioanalysis. However, hydrophilic interaction chromatography (HILIC) could represent a viable alternative to RPLC for the analysis of polar and/or ionizable compounds, as it often provides higher MS sensitivity and alternative selectivity. Nevertheless, this technique can be also prone to matrix effects (ME). ME are one of the major issues in quantitative LC-MS bioanalysis. To ensure acceptable method performance (i.e., trueness and precision), a careful evaluation and minimization of ME is required. In the present study, the incidence of ME in HILIC-MS/MS and RPLC-MS/MS was compared for plasma and urine samples using two representative sets of 38 pharmaceutical compounds and 40 doping agents, respectively. The optimal generic chromatographic conditions in terms of selectivity with respect to interfering compounds were established in both chromatographic modes by testing three different stationary phases in each mode with different mobile phase pH. A second step involved the assessment of ME in RPLC and HILIC under the best generic conditions, using the post-extraction addition method. Biological samples were prepared using two different sample pre-treatments, i.e., a non-selective sample clean-up procedure (protein precipitation and simple dilution for plasma and urine samples, respectively) and a selective sample preparation, i.e., solid phase extraction for both matrices. The non-selective pretreatments led to significantly less ME in RPLC vs. HILIC conditions regardless of the matrix. On the contrary, HILIC appeared as a valuable alternative to RPLC for plasma and urine samples treated by a selective sample preparation. Indeed, in the case of selective sample preparation, the compounds influenced by ME were different in HILIC and RPLC, and lower and similar ME occurrence was generally observed in RPLC vs. HILIC for urine and plasma samples, respectively. The complementary of both chromatographic modes was also demonstrated, as ME was observed only scarcely for urine and plasma samples when selecting the most appropriate chromatographic mode.
Resumo:
This study shows the possibility offered by modern ultra-high performance supercritical fluid chromatography combined with tandem mass spectrometry in doping control analysis. A high throughput screening method was developed for 100 substances belonging to the challenging classes of anabolic agents, hormones and metabolic modulators, synthetic cannabinoids and glucocorticoids, which should be detected at low concentrations in urine. To selectively extract these doping agents from urine, a supported liquid extraction procedure was implemented in a 48-well plate format. At the tested concentration levels ranging from 0.5 to 5 ng/mL, the recoveries were better than 70% for 48-68% of the compounds and higher than 50% for 83-87% of the tested substances. Due to the numerous interferences related to isomers of steroids and ions produced by the loss of water in the electrospray source, the choice of SFC separation conditions was very challenging. After careful optimization, a Diol stationary phase was employed. The total analysis time for the screening assay was only 8 min, and interferences as well as susceptibility to matrix effect (ME) were minimized. With the developed method, about 70% of the compounds had relative ME within the range ±20%, at a concentration of 1 and 5 ng/mL. Finally, limits of detection achieved with the above-described strategy including 5-fold preconcentration were below 0.1 ng/mL for the majority of the tested compounds. Therefore, LODs were systematically better than the minimum required performance levels established by the World anti-doping agency, except for very few metabolites.
Resumo:
The ability of Mycobacterium tuberculosis to establish a latent infection (LTBI) in humans confounds the treatment of tuberculosis. Consequently, there is a need to discover new therapeutic agents that can kill M. tuberculosis both during active disease and LTBI. The streptomycin-dependent strain of M. tuberculosis, 18b, provides a useful tool for this purpose since upon removal of streptomycin (STR) it enters a non-replicating state that mimics latency both in vitro and in animal models. The 4.41 Mb genome sequence of M. tuberculosis 18b was determined and this revealed the strain to belong to clade 3 of the ancient ancestral lineage of the Beijing family. STR-dependence was attributable to insertion of a single cytosine in the 530 loop of the 16S rRNA and to a single amino acid insertion in the N-terminal domain of initiation factor 3. RNA-seq was used to understand the genetic programme activated upon STR-withdrawal and hence to gain insight into LTBI. This revealed reconfiguration of gene expression and metabolic pathways showing strong similarities between non-replicating 18b and M. tuberculosis residing within macrophages, and with the core stationary phase and microaerophilic responses. The findings of this investigation confirm the validity of 18b as a model for LTBI, and provide insight into both the evolution of tubercle bacilli and the functioning of the ribosome.
Resumo:
The importance of chromatographic separation of enantiomers has been acknowledged. This review surveys the development, application and perspectives of polysaccharide carbamates as chiral stationary phase for HPLC.
Resumo:
Suomen ympäristönsuojelulaki (86/200) velvoittaa toiminnanharjoittajia olemaan selvillä päästöistään ja hakemaan ympäristöluvan ympäristön pilaantumisen vaaraa aiheuttavalle toiminnalle. Sellutehtaat tuottavat tietoa merkittävimmistä ilmaan johdettavista päästöistään mittaamalla niitä jatkuvatoimisesti. Tuloksia käytetään tiedottamisessa ja päätöksenteossa. Yksi tärkeimmistä käyttökohteista on ympäristöluvan ehtojen täyttymisen seuranta. Mittaustulosten on oltava luotettavia. Luotettavuutta voidaan arvioida vertailumittauksien ja mittausepävarmuustarkastelujen avulla. Tässä työssä määritettiin mittausepävarmuudet Imatran tehtaiden kuorikattilan (LCP-kattila) NOX-mittaukselle sekä sellutehtaan meesauunien ja soodakattiloiden mittauksille. Tämän jälkeen tarkasteltiin, kuinka mittausepävarmuus huomioidaan ympäristö¬luparajaseurannassa. Lopuksi arviointiin, kuinka jatkuvatoimisten mittalaitteiden laadunvarmistusstandardia SFS-EN 141481 voidaan soveltaa Imatran tehtailla. Tarkastellut jatkuvatoimiset mittaukset todettiin varsin luotettaviksi. Etenkin NOx¬mittaukset ovat luotettavia. Kuorikattila 2:lla luotettavuutta heikentää mittauspaikan epä¬edustavuus. Rikin yhdisteiden (SO2 ja TRS) mittausten luotettavuus on alhaisempi, koska mitattavat pitoisuudet ovat pieniä. Mittausten luotettavuus on kuin vertailumittausten. Kuorikattila 2:lla Mittausepävarmuus huomioidaan NOX-pitoisuuden lupaseurannassa LCP-asetuksen mukaisesti. Sellutehtaan TRS-päästöillä mittausepävarmuus voidaan huomioida joko LCP-asetuksen mukaisesti tai tilastomatemaattisesti. Kummallakin tavalla saadaan negatiivisia luparajaan verrattavia keskiarvoja. Standardia SFS-EN 141481 voidaan soveltaa kuorikattilalla mutta sellutehtaalla se voi olla epäkäytännöllistä, eikä välittömästi paranna mittausten luotettavuutta