970 resultados para Ion Beam Deposition
Resumo:
Tantalum oxynitride thin films were produced by magnetron sputtering. The films were deposited usinga pure Ta target and a working atmosphere with a constant N2/O2ratio. The choice of this constant ratiolimits the study concerning the influence of each reactive gas, but allows a deeper understanding of theaspects related to the affinity of Ta to the non-metallic elements and it is economically advantageous.This work begins by analysing the data obtained directly from the film deposition stage, followed bythe analysis of the morphology, composition and structure. For a better understanding regarding theinfluence of the deposition parameters, the analyses are presented by using the following criterion: thefilms were divided into two sets, one of them produced with grounded substrate holder and the otherwith a polarization of −50 V. Each one of these sets was produced with different partial pressure of thereactive gases P(N2+ O2). All the films exhibited a O/N ratio higher than the N/O ratio in the depositionchamber atmosphere. In the case of the films produced with grounded substrate holder, a strong increaseof the O content is observed, associated to the strong decrease of the N content, when P(N2+ O2) is higherthan 0.13 Pa. The higher Ta affinity for O strongly influences the structural evolution of the films. Grazingincidence X-ray diffraction showed that the lower partial pressure films were crystalline, while X-rayreflectivity studies found out that the density of the films depended on the deposition conditions: thehigher the gas pressure, the lower the density. Firstly, a dominant -Ta structure is observed, for lowP(N2+ O2); secondly a fcc-Ta(N,O) structure, for intermediate P(N2+ O2); thirdly, the films are amorphousfor the highest partial pressures. The comparison of the characteristics of both sets of produced TaNxOyfilms are explained, with detail, in the text.
Resumo:
Aiming at biosignal acquisition for bioelectrodes application, Ti-Ag thin films were produced by GLAD, in order to tailor their electromechanical properties. The electrical behaviour of the sculptured Ti-Ag thin films was studied with increasing annealing temperatures. The results revealed a good correlation with the set of morphological features displayed. With the increase of the vapour flux angle, a more defined structure was obtained, as well as a more porous morphology, which increased the electrical resistivity of the coatings. An important point consists in the recrystallization of Ti-Ag intermetallic phases due to the temperature increase (between 558 K and 773 K), which resulted in a sharp decrease of the electrical resistivity values.
Resumo:
Dissertação de mestrado integrado em Engenharia de Materiais
Resumo:
Lithium-ion battery cathodes have been fabricated by screen-printing through the development of CLiFePO4 inks. It is shown that shear thinning polymer solutions in N-methyl-2-pyrrolidone (NMP) with Newtonian viscosity above 0.4 Pa s are the best binders for formulating a cathode paste with satisfactory film forming properties. The paste shows an elasticity of the order of 500 Pa and, after shear yielding, shows an apparent viscosity of the order of 3 Pa s for shear rates corresponding to those used during screen-printing. The screen-printed cathode produced with a thickness of 26 mm shows a homogeneous distribution of the active material, conductive additive and polymer binder. The total resistance and diffusion coefficient of the cathode are 450 V and 2.5 10 16cm2 s 1, respectively. The developed cathodes show an initial discharge capacity of 48.2 mAh g 1 at 5C and a discharge value of 39.8 mAh g 1 after 50 cycles. The capacity retention of 83% represents 23% of the theoretical value (charge and/or discharge process in twenty minutes), demonstrating the good performance of the battery. Thus, the developed C-LiFePO4 based inks allow to fabricate screen-printed cathodes suitable for printed lithium-ion batteries
Resumo:
Tese de Doutoramento (Programa doutoral em Engenharia de Materiais)
Resumo:
Biofilm adhesion to metals (copper, aluminium and brass) was studied at two different velocities and pH values of 7 and 9. Both bacteria and metals showed negative surface charges at those values of pH, which tends to slow down adhesion. Film densities increased with the fluid velocity and were also affected by the pH and by the growth rate of the bacteria. Long duration tests based on heat transfer measurements were run at five different fluid velocities and at pH = 7, showing in general an asymptotic behaviour and a control of deposition by adhesion and growth phenomena.
Resumo:
A fines de la década del '60 un grupo de investigadores rusos pudo obtener diamante a partir de experimentos con reacciones en fase vapor a bajas presiones de los gases envueltos en el proceso. En 1976 Derjagin et al. mostraron que la nucleación de diamante es posible sobre sustratos de Cu y en 1982 Matsumoto demuestra que la nucleación y crecimiento continuo a bajas presiones de diamante es posible sobre diversos substratos. Las especiales propiedades del diamante (D): dureza, elevado punto de fusión, inercia química, así como elevada conductividad del calor, sonido y de señales ópticas, ubican a este material como una de las prioridades de desarrollo e investigación de grupos de excelencia en el mundo entero. (...) Objetivos Generales y Específicos: El objetivo de este proyecto se basa en la construcción de un reactor para CVD (Chemical Vapour Deposition) y de los elementos auxiliares necesarios para producir diamante sintético por este método. Determinando los parámetros que controlan el proceso: mezcla de gases adecuada, temperatura de substrato, temperatura del plasma, presión parcial de los gases, vacío necesario y otros. En la primera etapa de 2 años se priorizará la puesta a punto del método, para luego pasar al estudio de las diferentes aplicaciones tecnológicas necesarias para la región. Específicamente, en el tercer año se tratará de generar diamantes como recubrimientos para herramientas de corte, así como para trapanos de velocidad, aprovechando residuos para la industria de abrasivos. Los objetivos generales no se cirscuncriben sólo al hecho de montar un reactor en laboratorio para CVD, sino una vez encontrados los parámetros que gobiernan esta técnica, producir diamante sintético para aplicaciones en la industria de herramientas de corte, micrófonos y óptica. Otro objetivo general de importancia es la formación de recursos humanos en técnicas de vacío, ingeniería de superficie y tecnología de plasma a través del personal y de los estudiantes involucrados en el proyecto, así como los participantes en cátedras del Departamento de Mecánica. En cuanto a los objetivos específicos para los dos primeros años, es preparar, construir y poner a punto un reactor de laboratorio de filamento caliente (Hot filament) por tecnología de plasma tipo CVD para obtener diamante sintético a partir de gases.
Resumo:
Vacuum arc, deposition, ion current, plasma properties, power electronics, bias voltage
Resumo:
Vacuum arc, magnetic field, pulsed process, spot movement, ion current, plasma properties, deposition rate
Resumo:
This work presents the results of an investigation of processes in the melting zone during Electron Beam Welding(EBW) through analysis of the secondary current in the plasma.The studies show that the spectrum of the secondary emission signal during steel welding has a pronounced periodic component at a frequency of around 15–25 kHz. The signal contains quasi-periodic sharp peaks (impulses). These impulses have stochastically varying amplitude and follow each other inseries, at random intervals between series. The impulses have a considerable current (up to 0.5 A). It was established that during electron-beam welding with the focal spot scanning these impulses follow each other almost periodically. It was shown that the probability of occurrence of these high-frequency perturbation increases with the concentration of energy in the interaction zone. The paper also presents hypotheses for the mechanism of the formation of the high-frequency oscillations in the secondary current signal in the plasma.
Resumo:
The aim of this paper is to find normative foundations of Approval Voting. In order to show that Approval Voting is the only social choice function that satisfies anonymity, neutrality, strategy-proofness and strict monotonicity we rely on an intermediate result which relates strategy-proofness of a social choice function to the properties of Independence of Irrelevant Alternatives and monotonicity of the corresponding social welfare function. Afterwards we characterize Approval Voting by means of strict symmetry, neutrality and strict monotonicity and relate this result to May's Theorem. Finally, we show that it is possible to substitute the property of strict monotonicity by the one efficiency of in the second characterization.
Resumo:
Estudi elaborat a partir d’una estada al Paul Scherrer Institut del Maig a l’Octubre del 2006 amb l’ajuda i supervisió dels Dr. Konstantins Jefimovs i Dr. Christian David. Focalitzar raigs X tous és una necessitat essencial per al microanàlisis, la microscopia, i fer imatges en moltes Instal·lacions de Radiació Sincrotró. Les Lents Zonals de Fresnel (FZP, de la denominació anglesa “Fresnel Zone Plates”) han demostrat donar uns punts focals amb una resolució espacial destacada i una baixa il·luminació de fons. Tanmateix, la fabricació de FZP és complexa i no totalment reproduïble. A més a més, el temps de vida de les FZP és força curt, ja que estant situades sobre membranes de nitrur de silici molt fines i altament absorbents. Per tant, hem fet esforços per implementar FZP de silici, que s’espera que siguin més resistents. L’element està fet d’una oblia de cristall de silici poc absorbent, i no presenta cap interfase entre materials. Així doncs, aquestes lents són especialment adequades per a aguantar les extremes càrregues de radiació de les fonts de raigs X més brillants. Particularment, això és molt important per a les aplicacions a les pròximes generacions de fonts de raigs X, com els Làsers d’Electrons Lliures (FEL, de la denominació anglesa “Free Electron Laser”). El silici també garanteix que no hi hagi cap banda d’absorció en el rang d’energies de la finestra de l’aigua (200-520 eV), fent aquestes lents ideals per a fer imatges de mostres biològiques. En aquest informe, hi ha una descripció detallada de tots els passos involucrats en la fabricació de les Lents Zonals de Fresnel de silici. En resum, les estructures de FZP es modelen sobre una resina utilitzant litografia per feix d’electrons i llavors el patró es transmet al silici mitjançant un gravat d’ions reactius (RIE, de la denominació anglesa ‘Reactive Ion Etching’) utilitzant una fina (20 nm) màscara de Crintermitja. Les membranes de silici es poden aprimar després de la fabricació de les estructures per a garantir una transmissió suficient fins i tot a baixes energies. Aquest informe també inclou l’anàlisi i la discussió d’alguns experiments preliminars per avaluar el rendiment de les Si FZPs fets a la línia de llum PolLux del Swiss Ligth Source amb l’ajuda dels Dr. Jörg Raabe i Dr. George Tzvetkov.
Resumo:
PURPOSE: To evaluate the efficacy of first-line chemotherapy (CT) in preventing external-beam radiotherapy (EBR) and/or enucleation in patients with retinoblastoma (Rbl). PATIENTS AND METHODS: Twenty-four patients with newly diagnosed unilateral or bilateral Rbl received CT associated with local treatment (LT). Two to five courses of etoposide and carboplatin were administered at 3- to 4-week intervals, depending on tumor response, and were completed each time by LT. RESULTS: Tumor response was observed in all eyes. Twenty-one of 24 patients showed a complete response (CR) that persisted at a median follow-up (FU) of 31 months (range, 4 to 41 months). Among the three patients who relapsed, two were lost to FU and one died of progressive disease. CR was achieved by CT and LT alone in 15 (71.4%) of 21 patients with less advanced disease (groups I to III). Six other patients with advanced disease (groups IV and V) experienced treatment failure and needed salvage treatment by EBR and/or enucleation. The difference between the two patient groups with regard to disease stage was statistically significant (P <.0001). EBR could be avoided in 13 (68.4%) of 19 patients, who presented with groups I to III (15 eyes) and group V (one eye) disease, whereas enucleation could be avoided in only two (40%) of five. CONCLUSION: CT combined with intensive LT is effective in patients with groups I to III Rbl, permitting the avoidance of EBR in the majority of these young children and, thus, reducing the risk of long-term sequelae. This is in contrast with the disappointing results for patients with groups IV and V Rbl, in whom EBR and/or enucleation was needed.
Resumo:
AbstractBACKGROUND: KRAB-ZFPs (Krüppel-associated box domain-zinc finger proteins) are vertebrate-restricted transcriptional repressors encoded in the hundreds by the mouse and human genomes. They act via an essential cofactor, KAP1, which recruits effectors responsible for the formation of facultative heterochromatin. We have recently shown that KRAB/KAP1 can mediate long-range transcriptional repression through heterochromatin spreading, but also demonstrated that this process is at times countered by endogenous influences.METHOD: To investigate this issue further we used an ectopic KRAB-based repressor. This system allowed us to tether KRAB/KAP1 to hundreds of euchromatic sites within genes, and to record its impact on gene expression. We then correlated this KRAB/KAP1-mediated transcriptional effect to pre-existing genomic and chromatin structures to identify specific characteristics making a gene susceptible to repression.RESULTS: We found that genes that were susceptible to KRAB/KAP1-mediated silencing carried higher levels of repressive histone marks both at the promoter and over the transcribed region than genes that were insensitive. In parallel, we found a high enrichment in euchromatic marks within both the close and more distant environment of these genes.CONCLUSION: Together, these data indicate that high levels of gene activity in the genomic environment and the pre-deposition of repressive histone marks within a gene increase its susceptibility to KRAB/KAP1-mediated repression.
Resumo:
Metabolic labeling techniques have recently become popular tools for the quantitative profiling of proteomes. Classical stable isotope labeling with amino acids in cell cultures (SILAC) uses pairs of heavy/light isotopic forms of amino acids to introduce predictable mass differences in protein samples to be compared. After proteolysis, pairs of cognate precursor peptides can be correlated, and their intensities can be used for mass spectrometry-based relative protein quantification. We present an alternative SILAC approach by which two cell cultures are grown in media containing isobaric forms of amino acids, labeled either with 13C on the carbonyl (C-1) carbon or 15N on backbone nitrogen. Labeled peptides from both samples have the same nominal mass and nearly identical MS/MS spectra but generate upon fragmentation distinct immonium ions separated by 1 amu. When labeled protein samples are mixed, the intensities of these immonium ions can be used for the relative quantification of the parent proteins. We validated the labeling of cellular proteins with valine, isoleucine, and leucine with coverage of 97% of all tryptic peptides. We improved the sensitivity for the detection of the quantification ions on a pulsing instrument by using a specific fast scan event. The analysis of a protein mixture with a known heavy/light ratio showed reliable quantification. Finally the application of the technique to the analysis of two melanoma cell lines yielded quantitative data consistent with those obtained by a classical two-dimensional DIGE analysis of the same samples. Our method combines the features of the SILAC technique with the advantages of isobaric labeling schemes like iTRAQ. We discuss advantages and disadvantages of isobaric SILAC with immonium ion splitting as well as possible ways to improve it