877 resultados para High Performance liquid chromatography coupled with mass spectrometry (LC-MS)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, new method permitting the simultaneous determination and confirmation of trace residues of 24 different growth promoters and metabolites using liquid chromatography-mass spectrometry was developed and validated. The compounds were extracted from bovine tissue using acetonitrile; sodium sulphate was also added at this stage to aid with purification. The resulting mixture was then evaporated to approximately 1 ml and subsequently centrifuged at high speed and an aliquot injected onto the LC-MS/MS system. The calculated CC values ranged between 0.11 and 0.46 mu g kg-1; calculated CC were in the range 0.19-0.79 mu g kg-1. Accuracy, measurement of uncertainty, repeatability and linearity were also determined for each analyte. The analytical method was applied to a number of bovine tissue samples imported into Ireland from third countries. Levels of progesterone were found in a number of samples at concentrations ranging between 0.28 and 30.30 mu g kg-1. Levels of alpha- and beta-testosterone were also found in a number of samples at concentrations ranging between 0.22 and 8.63 mu g kg-1 and between 0.16 and 2.08 mu g kg-1 respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method is described for the analysis of deuterated and undeuterated alpha-tocopherol in blood components using liquid chromatography coupled to an orthogonal acceleration time-of-flight (TOF) mass spectrometer. Optimal ionisation conditions for undeuterated (d0) and tri- and hexadeuterated (d3 or d6) alpha-tocopherol standards were found with negative ion mode electrospray ionisation. Each species produced an isotopically resolved single ion of exact mass. Calibration curves of pure standards were linear in the range tested (0-1.5 muM, 0-15 pmol injected). For quantification of d0 and d6 in blood components following a standard solvent extraction, a stable-isotope-labelled internal standard (d3-alpha-tocopherol) was employed. To counter matrix ion suppression effects, standard response curves were generated following identical solvent extraction procedures to those of the samples. Within-day and between-day precision were determined for quantification of d0- and d6-labelled alpha-tocopherol in each blood component and both averaged 3-10%. Accuracy was assessed by comparison with a standard high-performance liquid chromatography (HPLC) method, achieving good correlation (r(2) = 0.94), and by spiking with known concentrations of alpha-tocopherol (98% accuracy). Limits of detection and quantification were determined to be 5 and 50 fmol injected, respectively. The assay was used to measure the appearance and disappearance of deuterium-labelled alpha-tocopherol in human blood components following deuterium-labelled (d6) RRR-alpha-tocopheryl acetate ingestion. The new LC/TOFMS method was found to be sensitive, required small sample volumes, was reproducible and robust, and was capable of high throughput when large numbers of samples were generated. Copyright (C) 2003 John Wiley Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article presents a method employing stir bar sorptive extraction (SBSE) with in situ derivatization, in combination with either thermal or liquid desorption on-line coupled to gas chromatography-mass spectrometry for the analysis of fluoxetine in plasma samples. Ethyl chloroformate was employed as derivatizing agent producing symmetrical peaks. Parameters such as solvent polarity, time for analyte desorption, and extraction time, were evaluated. During the validation process, the developed method presented specificity, linearity (R-2 > 0.99), precision (R.S.D. < 15%), and limits of quantification (LOQ) of 30 and 1.37 pg mL(-1), when liquid and thermal desorption were employed, respectively. This simple and highly sensitive method showed to be adequate for the measurement-of fluoxetine in typical and trace concentration levels. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A fast, simple and environmentally friendly ultrasound-assisted dispersive liquid-liquid microextraction (USA-DLLME) procedure has been developed to preconcentrate eight cyclic and linear siloxanes from wastewater samples prior to quantification by gas chromatography-mass spectrometry (GC-MS). A two-stage multivariate optimization approach has been developed employing a Plackett-Burman design for screening and selecting the significant factors involved in the USA-DLLME procedure, which was later optimized by means of a circumscribed central composite design. The optimum conditions were: extractant solvent volume, 13 µL; solvent type, chlorobenzene; sample volume, 13 mL; centrifugation speed, 2300 rpm; centrifugation time, 5 min; and sonication time, 2 min. Under the optimized experimental conditions the method gave levels of repeatability with coefficients of variation between 10 and 24% (n=7). Limits of detection were between 0.002 and 1.4 µg L−1. Calculated calibration curves gave high levels of linearity with correlation coefficient values between 0.991 and 0.9997. Finally, the proposed method was applied for the analysis of wastewater samples. Relative recovery values ranged between 71–116% showing that the matrix had a negligible effect upon extraction. To our knowledge, this is the first time that combines LLME and GC-MS for the analysis of methylsiloxanes in wastewater samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The deposition of biological material (biofouling) onto polymeric contact lenses is thought to be a major contributor to lens discomfort and hence discontinuation of wear. We describe a method to characterize lipid deposits directly from worn contact lenses utilizing liquid extraction surface analysis coupled to tandem mass spectrometry (LESA-MS/MS). This technique effected facile and reproducible extraction of lipids from the contact lens surfaces and identified lipid molecular species representing all major classes present in human tear film. Our data show that LESA-MS/MS is a rapid and comprehensive technique for the characterization of lipid-related biofouling on polymer surfaces.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method for the determination of imidacloprid in paddy water and soil was developed using liquid chromatography electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS). Separation of imidacloprid was carried out on a Shimadzu C18 column (150 mm × 4.6 mm, 4.6 μm) with an acetonitrile?water (50 : 50, v/v) mobile phase containing 0.1% of acetic acid. The flow rate was 0.3 mL/min in isocratic mode. The product ion at 209 m/z was selected for quantification in multiple-reaction monitoring scan mode. Imidacloprid residues in soil were extracted by a solid-liquid extraction method with acetonitrile. Water samples were filtered and directly injected for analysis without extraction. Detection limits of 0.5 μg/kg and 0.3 μg/L were achieved for soil and water samples, respectively. The method had recoveries of 90 ± 2% (n = 4) for soil samples and 100 ± 2% (n = 4) for water samples. A linear relationship was observed throughout the investigated range of concentrations (1-200 μg/L), with the correlation coefficients ranging from 0.999 to 1.000. © Pleiades Publishing, Ltd., 2010.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fluorinated surfactant-based aqueous film-forming foams (AFFFs) are made up of per- and polyfluorinated alkyl substances (PFAS) and are used to extinguish fires involving highly flammable liquids. The use of perfluorooctanesulfonic acid (PFOS) and other perfluoroalkyl acids (PFAAs) in some AFFF formulations has been linked to substantial environmental contamination. Recent studies have identified a large number of novel and infrequently reported fluorinated surfactants in different AFFF formulations. In this study, a strategy based on a case-control approach using quadrupole time-of-flight tandem mass spectrometry (QTOF-MS/MS) and advanced statistical methods has been used to extract and identify known and unknown PFAS in human serum associated with AFFF-exposed firefighters. Two target sulfonic acids [PFOS and perfluorohexanesulfonic acid (PFHxS)], three non-target acids [perfluoropentanesulfonic acid (PFPeS), perfluoroheptanesulfonic acid (PFHpS), and perfluorononanesulfonic acid (PFNS)], and four unknown sulfonic acids (Cl-PFOS, ketone-PFOS, ether-PFHxS, and Cl-PFHxS) were exclusively or significantly more frequently detected at higher levels in firefighters compared to controls. The application of this strategy has allowed for identification of previously unreported fluorinated chemicals in a timely and cost-efficient way.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A sensitive and selective liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method was developed to determine olanzapine (OLZ) in human urine. After solid-phase extraction with SPE cartridge, the urine sample was analysed on a C-18 column (Symmetry 3.5 mu m, 50 x 4.6 mm i.d) interfaced with a triple quadrupole tandem mass spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase consisted of ammonium acetate (pH 7.8)-acetonitrile (10:90, v/v). The method was linear over a concentration range of 1-100 ngml(-1). The lower limit of quantitation was 1 ngml(-1). The intra-day and inter-day relative standard deviation across three validation runs over the entire concentration range was < 11.5 %. The accuracy determined at three concentrations (8.0, 50.0 and 85.0 ngml(-1) OLZ) was within +/- 1.21 % in terms of relative errors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A lectin from phloem exudates of Luffa acutangula (ridge gourd) was purified on chitin affinity chromatography and characterized for its amino acid sequence and to study the role of tryptophan in its activity. The purified lectin was subjected to various proteolytic digestions, and the resulting peptides were analyzed by liquid chromatography coupled electrospray ionization ion trap mass spectrometer. The peptide precursor ions were fragmented by collision-induced dissociation or electron transfer dissociation experiments, and a manual interpretation of MS/MS was performed to deduce amino acid sequence. This gave rise to almost complete sequence coverage of the lectin which showed high-sequence similarity with deduced sequences of phloem lectins present in the database. Chemical modification of lysine, tyrosine, histidine, arginine, aspartic acid, and glutamic acid residues did not inhibit the hemagglutinating activity. However, the modification of tryptophan residues using N-bromosuccinimide showed the loss of hemagglutinating activity. Additionally, the mapping of tryptophan residues was performed to determine the extent and number of residues modified, which revealed that six residues per molecule were oxidized suggesting their accessibility. The retention of the lectin activity was seen when the modifications were performed in the presence of chitooligosaccharides due to protection of a tryptophan residue (W-102) in the protein. These studies taken together have led to the identification of a particular tryptophan residue (W-102) in the activity of the lectin. (c) 2015 IUBMB Life, 67(12):943-953, 2015

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A liquid chromatography electrospray mass spectrometry (LC/ESI/MS) method working in multiple reactions monitoring mode for the determination of trace amounts of microcystin variants (MC-LR and [Dha(7)] MC-LR) in waters was developed. The limit of quantification was 0.05 mu g/L and the limit of detection was 0.015 mu g/L for MC-LR and [Dha(7)] MC-LR, respectively. Recoveries for MCs were in the range of 68%-81%. MC-LR and [Dha(7)] MC-LR were chemically stable with similar physiochemical behavior.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, sensitive, and accurate method for determination of polybrominated diphenyl ethers (PBDEs) in soil has been developed based on headspace solid-phase microextraction (HS-SPME) followed by gas chromatography-mass spectrometry (GC-MS). Permethylated-beta-cyclodextrin/hydroxyl-termination silicone oil (PM-beta-CD/OH-TSO) fiber was first prepared by sol-gel technology and employed in SPME procedure. By exploiting the superiorities of sot-gel coating technique and the advantages of the high hydrophobic doughnut-shaped cavity of PM-beta-CD, the novel fiber showed desirable operational stability and extraction ability. After optimization on extraction conditions like water addition, extraction temperature, extraction time, salts effect, and solvents addition, the method was validated in soil samples, achieving good linearity (r>0.999), precision (R.S.D. < 10%), accuracy (recovery>78%), and detection limits (S/N =3) raging from 13.0 to 78.3 pg/g. (c) 2007 Published by Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

1:1 complexes of beta-cyclodextrin (CD) with three amino acids (Gly, Phe and Trp) have been detected as ions in the gas phase using infusion positive and negative ion electrospray ionization mass spectrometry (ESI-MS). In contrast with the positive ion ESI mass spectra of simple aqueous solutions, the aggregates and adducts usually formed in the ESI process did not appear in the positive ion ESI spectra of solutions buffered with ammonium acetate (NH4Ac), even at higher analyte concentrations, These studies suggest that addition of buffer and/or use of a low analyte concentration should be used to overcome formation of aggregates and metal ion adducts in such mass spectrometry studies. Also, the deprotonated complexes are dissociated by collision induced dissociation (CID) to form an abundant product ion, the deprotonated CD, requiring transfer of a proton to the amino acid carboxyl group, To understand formation of complexes in the gas phase, gel permeation chromatography (GPC) was used to separate free amino acids (AAs) from complexes in an incubated solution. The ESI mass spectra of the GPC fractions show the presence of 1:1 complexes of both CD-aromatic amino acids and CD-aliphatic amino acids. Compared with CD-aliphatic amino acid complexes, CD-aromatic amino acid complexes appear to be destabilized in the gas phase, possibly because the hydrophobic interaction which binds the aromatic group of amino acids in the CD cavity in solution may become repulsive when solvent evaporates from the droplets during the electrospray process, whereas those complex ions formed as proton bound dimers are stabilized by electrostatic forces, the major binding force for such complexes in the gas phase. In addition, the GPC technique coupled with off-line ESI-MS can rapidly separate CD complexes by size, and provides some information on the character of the complexes in solution. (C) 1998 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and sensitive method for the determination of free fatty acids (FFAs) using acridone-9-ethyl-p-toluenesulfonate (AETS) as a fluorescence derivatization reagent by high performance liquid chromatography (HPLC) has been developed. Free fatty acid derivatives were separated on an Eclipse XDB-C-8 column with a good baseline resolution and detected with the fluorescence of which excitation and emission wavelengths of derivatives were set at lambda(ex) 404 and lambda(em) 440 nm, respectively. Identification of 19 fatty acid derivatives was carried out by online post-column mass spectrometry with an atmospheric pressure chemical ionization (APCI) source under positive-ion detection mode. Nineteen FFAs from the extract of Lomatogonium rotatum are sensitively determined. The results indicate that the plant Lomatogonium rotatum is enriched with an abundance of FFAs and FFAs of higher contents, which mainly focus on even carbon atoms, C-14, C-16, and C-18. The validation of the method including linearity, repeatability, and detection limits was examined. Most linear correlation coefficients for fatty acid derivatives are > 0.9989, and detection limits (at signal-to-noise of 3: 1) are 12.3-43.7 fmol. The relative standard deviations (RSDs) of the peak areas and retention times for 19 FFAs standards are < 2.24% and 0.45%, respectively. The established method is rapid and reproducible for the separation determination of FFAs from the extract of Lomatogonium rotatum with satisfactory results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An immunoaffinity chromatographic (IAC) method for the selective extraction and concentration of 13 organophosphorus pesticides (OPs, including coumaphos, parathion, phoxim, quinalphos, dichlofenthion, triazophos, azinphos-ethyl, phosalone, isochlorthion, parathion-methyl, cyanophos, disulfoton, and phorate) prior to analysis by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed. The IAC column was prepared by covalently immobilizing a monoclonal antibody with broad specificity for OPs on CNBr-activated Sephrose 4B. The column capacity ranged from 884 to 2641 ng/mL of gel. The optimum elution solvent was 0.01 M phosphate-buffered saline containing 80% methanol. The breakthrough volume of the IAC column was found to be 400 mL. Recoveries of OPs from spiked environmental samples by IAC cleanup and HPLC-MS/MS analysis ranged from 60.2 to 107.1%, with a relative standard deviation below 11.1%. The limit of quantitation for 13 OPs ranged from 0.01 to 0.13 ng/mL (ng/g). The application of IAC cleanup coupled to HPLC-MS/MS in real environmental samples demonstrated the potential of this method for the determination of OP residues in environmental samples at trace levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)