976 resultados para HPLC-ESI-MSn
Resumo:
2016
Resumo:
Abstract: The area near the Araguaia River, between Goiás and Mato Grosso States, is the location of a portion of the recharging of the Guarani Aquifer, which is one of the world¿s largest aquifer systems and an important source of drinking water. This reservoir could be threatened by the widespread use of pesticides in maize and soybean cultivation in this area. Thus, this work developed analytical methods for the determination of imazethapyr, nicosulfuron, imazaquin, carbofuran, atrazine, linuron, clorimuronethyl and diflubenzuron, pesticides used in maize and soybean cultivation. Pesticide separation, identification and quantification were performed using High-Performance Liquid Chromatography with Diode Array Detection (HPLC-DAD) and Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry (LC-ESI-MS/MS). Solid Phase Extraction (SPE) with C18 sorbents was optimized for sample extraction from water. Soil samples were extracted by mechanical shaking, sonication or microwave-assisted extraction with industrial and home microwave ovens. Methods were validated resulting in limits of quantification (LOQ) for the pesticides in water in the range of 0.015-0.1 ng mL, using SPE-HPLC-DAD, and 0.01 ng mL using LC-ESI-MS/MS. LOQ of 1 ng mL for all pesticides in soil were achieved using the home microwave oven and LC-ESI-MS/MS. Recoveries for pesticides with all methods were in the range 70-120 %. Relative standard deviations for repeatability and intermediate precision were less than 15 %. SPEHPLC- DAD and LC-ESI-MS/MS were employed for the analysis of samples of water from the recharge area and most of the pesticides were detected at concentrations below the minimum residue limit (MRL) of 0.1 ng mL established by the European Community. The home microwave oven and LC-ESI-MS/MS were used for the analysis of soil samples from two other regions of Brazil and the pesticides were not detected in these samples. Adsorption and desorption parameters were determined for imazethapyr, imazaquin, nicosulfuron and chlorimuron-ethyl, indicating that these pesticides have little affinity for the soil of the region of the Guarani Aquifer recharge, and show significant leaching potential, according to the ground water ubiquity score (GUS index) for these pesticides.
Resumo:
Este estudio se realizó con el objeto de conocer el nivel de aflatoxina M1 (AFM1) presenteen quesillos artesanales comercializados en los mercados 9 de Octubre, 12 de Abril, 10 de Agosto y Feria Libre de la Ciudad de Cuenca mediante la técnica de Cromatografía Líquida de Alta Resolución (HPLC)y su grado de adecuación con la normativa de Brasilcorrespondiente a 2.5 ug/Kg de AFM1 en quesos. Se analizaron 33 muestras, donde 7 muestras fueron positivas de las cuales 4 estaban entre el límite de detección y cuantificación (0,04 – 0,08ug/kg), 3 fueron cuantificables, siendo la máxima concentración 0.83 ug/kg.Los valores de AFM1 fueron inferiores al límite máximo permitido por la normativa , por lo tanto, las distintas muestras de quesillos artesanales comercializados en los mercados 9 de Octubre, 12 de Abril, 10 de Agosto y Feria Libre de la Ciudad de Cuenca estudiadas en esta investigación podrían considerarse aptas para el consumo humanoen cuanto a exposición a AFM1.
Resumo:
2009
Resumo:
2009
Resumo:
The drugs studied in this work have been reportedly used to commit drug-facilitated sexual assault (DFSA), commonly known as "date rape". Detection of the drugs was performed using high-performance liquid chromatography with ultraviolet detection (HPLC/UV) and identified with high performance-liquid chromatography mass spectrometry (HPLC/MS) using selected ion monitoring (SIM). The objective of this study was to develop a single HPLC method for the simultaneous detection, identification and quantitation of these drugs. The following drugs were simultaneously analyzed: Gamma-hydroxybutyrate (GHB), scopolamine, lysergic acid diethylamide, ketamine, flunitrazepam, and diphenhydramine. The results showed increased sensitivity with electrospray (ES) ionization versus atmospheric pressure chemical ionization (APCI) using HPLC/MS. HPLC/ES/MS was approximately six times more sensitive than HPLC/APCI/MS and about fifty times more sensitive than HPLC/UV. A limit of detection (LOD) of 100 ppb was achieved for drug analysis using this method. The average linear regression coefficient of correlation squared (r2) was 0.933 for HPLC/UV and 0.998 for HPLC/ES/MS. The detection limits achieved by this method allowed for the detection of drug dosages used in beverage tampering. This method can be used to screen beverages suspected of drug tampering. The results of this study demonstrated that solid phase microextraction (SPME) did not improve sensitivity as an extraction technique when compared to direct injections of the drug standards.
Resumo:
Este trabalho teve como objectivo, o desenvolvimento de um método electroquímico, para quantificação do fármaco carbamazepina (CBZ) em águas contaminadas. Neste trabalho foram utilizados quatro métodos voltamétricos: a voltametria cíclica, a voltametria de varrimento linear, a voltametria de onda quadrada e a voltametria de impulso diferencial. Os eléctrodos de trabalho utilizados foram, o eléctrodo de mercúrio de gota suspensa, o eléctrodo de carbono vítreo clássico e um eléctrodo de carbono vítreo modificado com um filme de nanotubos de carbono de paredes múltiplas (MWCNTs). O eléctrodo de mercúrio de gota suspensa permitiu o estudo da redução da CBZ numa região de potencial mais catódico, e os eléctrodos de carbono vítreo, com e sem modificação, permitiram o estudo da oxidação da CBZ numa região de potencial mais anódico. Nas condições experimentais estudadas, o eléctrodo de mercúrio de gota suspensa revelou ser um sensor voltamétrico pouco eficaz na determinação quantitativa da carbamazepina, em amostras com uma matriz complexa. Entre os eléctrodos de carbono vítreo, o eléctrodo de carbono vítreo modificado com os MWCNTs revelou ser o sensor voltamétrico mais eficaz e sensível, na detecção e determinação da carbamazepina. Modificado com um filme de nanotubos de carbono de paredes múltiplas, que previamente foram dispersos em dihexadecilhidrogenofosfato (DHP) e água, este novo eléctrodo permitiu obter uma resposta electroquímica da CBZ, consideravelmente superior ao eléctrodo não modificado. Utilizando a voltametria de varrimento linear e as condições experimentais consideradas óptimas, o eléctrodo nanoestruturado permitiu obter uma relação linear entre o sinal medido e a concentração da CBZ no intervalo 0.13- 1.60 M (30.7- 378 g -1), com os limites de detecção e quantificação mais baixos, até à data reportados com métodos electroquímicos (0.04 e 0.14M, respectivamente). O eléctrodo modificado foi aplicado na quantificação da CBZ, em formulações farmacêuticas, em águas naturais tratadas e em amostras de águas residuais, ambas dopadas, obtendo-se taxas de recuperação consideravelmente elevadas (100.6%, 98.0%,95.8%, respectivamente). Os resultados obtidos, na análise da CBZ em amostras ambientais, com o eléctrodo modificado, foram comparados com resultados obtidos por HPLC-UV e LC ESI-MS/MS, validando o método electroquímico desenvolvido neste trabalho. ABSTRACT: The aim of this work was to develop a new electrochemical method for the quantification of carbamazepine (CBZ) in contaminated waters. ln this study, four voltammetric methods were used: cyclic voltammetry, linear sweep voltammetry, square wave voltammetry and differential pulse voltammetry. the working electrodes used were the hanging mercury drop electrode (HMDE), the classical glassy carbon electrode (GCE), and a glassy carbon electrode modified with a film of multi-walled carbon nanotubes (MWCNls). Using HMDE, the reduction of CBZ was studied in the cathodic potential region. the CGE sensors, with or without modification, allowed the study of CBZ oxidation in the anodic potential region. ln the tested conditions, the results obtained for the quantification of CBZ using the HMDE sensor were not very satisfactory, especially when more complex samples were analysed. When the MWCNls-dihexadecyl hydrogen phosphate (DHP) film coated GCE was used for the voltammetric determination of CBZ, the results obtained showed that this modified electrode exhibits excellent enhancement effects on the electrochemical oxidation of CBZ. the oxidation peak current of CBZ at this film modified electrode increased significantly, when compared with that at a bare glassy carbon electrode. The enhanced electrooxidation and voltammetry of CBZ at the surface of MWCNTs-DHP film coated GCE in phosphate buffer solution (pH 6.71) was attributed to the unique properties of MWCNTs such as large specific surface area and strong adsorptive properties providing more reaction sites. The proposed method was applied to the quantification of CBZ in pharmaceutical formulations, drinking water and wastewater samples with good recoveries and low limits of detection and quantification (0.04 and 0.14 M, respectively), and was positively compared with chromatographic techniques usually used in the quantification of pharmaceutical compounds in environmental samples. HPLC-UV and LC-ESI-MS/MS were also used in the quantification of CBZ in pharmaceutical formulations and wastewater samples to prove the importance and accuracy of his voltammetric method.
Resumo:
2012
Resumo:
2008
Resumo:
2016
Resumo:
2008
Resumo:
2012
Resumo:
Propolis is a resin that bees collect from different plant sources and use in the defense of the bee community. The intricate composition of propolis varies depending on plant sources from different geographic regions and many types have been reported. Red coloured propolis found in several states in Brazil and in other countries has known antimicrobial and antioxidant activity. Different analytical methods have been applied to studies regarding the chemical composition and plant origins of red propolis. In this study samples of red propolis from different regions have been characterised using direct infusion electrospray ionisation mass spectrometry (ESI(-)-MS) fingerprinting. Data from the fingerprints was extracted and analysed by multivariate analysis to group the samples according to their composition and marker compounds. Despite similar colour, the red coloured propolis samples were divided into three groups due to contrasting chemical composition, confirming the need to properly characterise the chemical composition of propolis.
Resumo:
The segment of the world population showing permanent or temporary lactose intolerance is quite significant. Because milk is a widely consumed food with an high nutritional value, technological alternatives have been sought to overcome this dilemma. Microfiltration combined with pasteurization can not only extend the shelf life of milk but can also maintain the sensory, functional, and nutritional properties of the product. This studied developed a pasteurized, microfiltered, lactose hydrolyzed (delactosed) skim milk (PMLHSM). Hydrolysis was performed using β-galactosidase at a concentration of 0.4mL/L and incubation for approximately 21h at 10±1°C. During these procedures, the degree of hydrolysis obtained (>90%) was accompanied by evaluation of freezing point depression, and the remaining quantity of lactose was confirmed by HPLC. Milk was processed using a microfiltration pilot unit equipped with uniform transmembrane pressure (UTP) ceramic membranes with a mean pore size of 1.4 μm and UTP of 60 kPa. The product was submitted to physicochemical, microbiological, and sensory evaluations, and its shelf life was estimated. Microfiltration reduced the aerobic mesophilic count by more than 4 log cycles. We were able to produce high-quality PMLHSM with a shelf life of 21 to 27d when stored at 5±1°C in terms of sensory analysis and proteolysis index and a shelf life of 50d in regard to total aerobic mesophile count and titratable acidity.
Resumo:
Negative-ion mode electrospray ionization, ESI(-), with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) was coupled to a Partial Least Squares (PLS) regression and variable selection methods to estimate the total acid number (TAN) of Brazilian crude oil samples. Generally, ESI(-)-FT-ICR mass spectra present a power of resolution of ca. 500,000 and a mass accuracy less than 1 ppm, producing a data matrix containing over 5700 variables per sample. These variables correspond to heteroatom-containing species detected as deprotonated molecules, [M - H](-) ions, which are identified primarily as naphthenic acids, phenols and carbazole analog species. The TAN values for all samples ranged from 0.06 to 3.61 mg of KOH g(-1). To facilitate the spectral interpretation, three methods of variable selection were studied: variable importance in the projection (VIP), interval partial least squares (iPLS) and elimination of uninformative variables (UVE). The UVE method seems to be more appropriate for selecting important variables, reducing the dimension of the variables to 183 and producing a root mean square error of prediction of 0.32 mg of KOH g(-1). By reducing the size of the data, it was possible to relate the selected variables with their corresponding molecular formulas, thus identifying the main chemical species responsible for the TAN values.