951 resultados para Combustion Ignition


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Glass fibre-reinforced plastics (GFRP), nowadays commonly used in the construction, transportation and automobile sectors, have been considered inherently difficult to recycle due to both: cross-linked nature of thermoset resins, which cannot be remolded, and complex composition of the composite itself, which includes glass fibres, matrix and different types of inorganic fillers. Presently, most of the GFRP waste is landfilled leading to negative environmental impacts and supplementary added costs. With an increasing awareness of environmental matters and the subsequent desire to save resources, recycling would convert an expensive waste disposal into a profitable reusable material. There are several methods to recycle GFR thermostable materials: (a) incineration, with partial energy recovery due to the heat generated during organic part combustion; (b) thermal and/or chemical recycling, such as solvolysis, pyrolisis and similar thermal decomposition processes, with glass fibre recovering; and (c) mechanical recycling or size reduction, in which the material is subjected to a milling process in order to obtain a specific grain size that makes the material suitable as reinforcement in new formulations. This last method has important advantages over the previous ones: there is no atmospheric pollution by gas emission, a much simpler equipment is required as compared with ovens necessary for thermal recycling processes, and does not require the use of chemical solvents with subsequent environmental impacts. In this study the effect of incorporation of recycled GFRP waste materials, obtained by means of milling processes, on mechanical behavior of polyester polymer mortars was assessed. For this purpose, different contents of recycled GFRP waste materials, with distinct size gradings, were incorporated into polyester polymer mortars as sand aggregates and filler replacements. The effect of GFRP waste treatment with silane coupling agent was also assessed. Design of experiments and data treatment were accomplish by means of factorial design and analysis of variance ANOVA. The use of factorial experiment design, instead of the one-factor-at-a-time method is efficient at allowing the evaluation of the effects and possible interactions of the different material factors involved. Experimental results were promising toward the recyclability of GFRP waste materials as aggregates and filler replacements for polymer mortar, with significant gain of mechanical properties with regard to non-modified polymer mortars.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work was to assess the influence of meteorological conditions on the dispersion of particulate matter from an industrial zone into urban and suburban areas. The particulate matter concentration was related to the most important meteorological variables such as wind direction, velocity and frequency. A coal-fired power plant was considered to be the main emission source with two stacks of 225 m height. A middle point between the two stacks was taken as the centre of two concentric circles with 6 and 20 km radius delimiting the sampling area. About 40 sampling collectors were placed within this area. Meteorological data was obtained from a portable meteorological station placed at approximately 1.7 km to SE from the stacks. Additional data was obtained from the electrical company that runs the coal power plant. These data covers the years from 2006 to the present. A detailed statistical analysis was performed to identify the most frequent meteorological conditions concerning mainly wind speed and direction. This analysis revealed that the most frequent wind blows from Northwest and North and the strongest winds blow from Northwest. Particulate matter deposition was obtained in two sampling campaigns carried out in summer and in spring. For the first campaign the monthly average flux deposition was 1.90 g/m2 and for the second campaign this value was 0.79 g/m2. Wind dispersion occurred predominantly from North to South, away from the nearest residential area, located at about 6 km to Northwest from the stacks. Nevertheless, the higher deposition fluxes occurred in the NW/N and NE/E quadrants. This study was conducted considering only the contribution of particulate matter from coal combustion, however, others sources may be present as well, such as road traffic. Additional chemical analyses and microanalysis are needed to identify the source linkage to flux deposition levels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coal contains trace elements and naturally occurring radionuclides such as 40K, 232Th, 238U. When coal is burned, minerals, including most of the radionuclides, do not burn and concentrate in the ash several times in comparison with their content in coal. Usually, a small fraction of the fly ash produced (2-5%) is released into the atmosphere. The activities released depend on many factors (concentration in coal, ash content and inorganic matter of the coal, combustion temperature, ratio between bottom and fly ash, filtering system). Therefore, marked differences should be expected between the by-products produced and the amount of activity discharged (per unit of energy produced) from different coal-fired power plants. In fact, the effects of these releases on the environment due to ground deposition have been received some attention but the results from these studies are not unanimous and cannot be understood as a generic conclusion for all coal-fired power plants. In this study, the dispersion modelling of natural radionuclides was carried out to assess the impact of continuous atmospheric releases from a selected coal plant. The natural radioactivity of the coal and the fly ash were measured and the dispersion was modelled by a Gaussian plume estimating the activity concentration at different heights up to a distance of 20 km in several wind directions. External and internal doses (inhalation and ingestion) and the resulting risk were calculated for the population living within 20 km from the coal plant. In average, the effective dose is lower than the ICRP’s limit and the risk is lower than the U.S. EPA’s limit. Therefore, in this situation, the considered exposure does not pose any risk. However, when considering the dispersion in the prevailing wind direction, these values are significant due to an increase of 232Th and 226Ra concentrations in 75% and 44%, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Engenharia Química – Ramo Optimização Energética na Indústria Química

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A presente dissertação centrou-se no estudo técnico-económico de dois cenários futuros para a continuação de fornecimento de energia térmica a um complexo de piscinas existente na região do vale do Tâmega. Neste momento a central de cogeração existente excedeu a sua licença de utilização e necessita de ser substituída. Os dois cenários em estudo são a compra de uma nova caldeira, a gás natural, para suprir as necessidades térmicas da caldeira existente a fuelóleo, ou o uso de um sistema de cogeração compacto que poderá estar disponível numa empresa do grupo. No primeiro cenário o investimento envolvido é cerca de 456 640 € sem proveitos de outra ordem para além dos requisitos térmicos, mas no segundo cenário os resultados são bem diferentes, mesmo que tenha de ser realizado o investimento de 1 000 000 € na instalação. Para este cenário foi efetuado um levantamento da legislação nacional no que toca à cogeração, recolheram-se dados do edifício como: horas de funcionamento, número de utentes, consumos de energia elétrica, térmica, água, temperatura da água das piscinas, temperatura do ar da nave, assim como as principais características da instalação de cogeração compacta. Com esta informação realizou-se o balanço de massa e energia e criou-se um modelo da nova instalação em software de modelação processual (Aspen Plus® da AspenTech). Os rendimentos térmico e elétrico obtidos da nova central de cogeração compacta foram, respetivamente, de 38,1% e 39,8%, com uma percentagem de perdas de 12,5% o que determinou um rendimento global de 78%. A avaliação da poupança de energia primária para esta instalação de cogeração compacta foi de 19,6 % o que permitiu concluir que é de elevada eficiência. O modelo criado permitiu compreender as necessidades energéticas, determinar alguns custos associados ao processo e simular o funcionamento da unidade com diferentes temperaturas de ar ambiente (cenários de verão e inverno com temperaturas médias de 20ºC e 5ºC). Os resultados revelaram uma diminuição de 1,14 €/h no custo da electricidade e um aumento do consumo de gás natural de 62,47 €/h durante o período mais frio no inverno devido ao aumento das perdas provocadas pela diminuição da temperatura exterior. Com esta nova unidade de cogeração compacta a poupança total anual pode ser, em média, de 267 780 € admitindo um valor para a manutenção de 97 698 €/ano. Se assim for, o projeto apresenta um retorno do investimento ao fim de 5 anos, com um VAL de 1 030 430 € e uma taxa interna de rentabilidade (TIR) de 14% (positiva, se se considerar a taxa de atualização do investimento de 3% para 15 anos de vida). Apesar do custo inicial ser elevado, os parâmetros económicos mostram que o projeto tem viabilidade económica e dará lucro durante cerca de 9 anos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O consumo energético verificado nas refinarias petrolíferas é muito elevado, sendo as fornalhas os equipamentos que mais contribuem para esse consumo. Neste estudo foi efetuada uma avaliação e otimização energética às fornalhas da Fábrica de Aromáticos da Refinaria de Matosinhos. Numa primeira fase foi efetuado um levantamento exaustivo de dados de todas as correntes de entrada e saída dos equipamentos para posteriormente efetuar os balanços de massa e energia a cada uma das fornalhas. Os dados relativos ao levantamento compreenderam dois períodos de funcionamento distintos da unidade fabril, o período de funcionamento normal e o período relativo ao arranque. O período de funcionamento normal foi relativo ao ano de 2012 entre os meses de janeiro a setembro, por sua vez o período de arranque foi de dezembro de 2012 a março de 2013. Na segunda fase foram realizados os balanços de massa e energia quantificando todas as correntes de entrada e saída das fornalhas em termos mássicos e energéticos permitindo o cálculo do rendimento térmico das fornalhas para avaliar a sua performance. A avaliação energética permitiu concluir que existe um consumo maior de energia proveniente da combustão do Fuel Gás do que do Fuel Óleo, tanto no período de funcionamento normal como no arranque. As fornalhas H0101, H0301 e a H0471 possuem os consumos mais elevados, sendo responsáveis por mais de 70% do consumo da Fábrica de Aromáticos. Na terceira fase foram enunciadas duas medidas para a otimização energética das três fornalhas mais consumidoras de energia, a limpeza mensal e o uso exclusivo de Fuel Gás como combustível. As poupanças energéticas obtidas para uma limpeza mensal foram de 0,3% na fornalha H0101, 0,7% na fornalha H0301 e uma poupança de 0,9 % na fornalha H0471. Para o uso exclusivo de Fuel Gás obteve-se uma poupança de 0,9% na fornalha H0101 e uma poupança de 1,3% nas fornalhas H0301 e H0471. A análise económica efetuada à sugestão de alteração do combustível mostra que os custos de operação sofrerão um aumento anual de 621 679 €. Apesar do aumento dos custos, a redução na emissão de 24% de dióxido de carbono, poderá justificar este aumento na despesa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the smart grids context, distributed energy resources management plays an important role in the power systems’ operation. Battery electric vehicles and plug-in hybrid electric vehicles should be important resources in the future distribution networks operation. Therefore, it is important to develop adequate methodologies to schedule the electric vehicles’ charge and discharge processes, avoiding network congestions and providing ancillary services. This paper proposes the participation of plug-in hybrid electric vehicles in fuel shifting demand response programs. Two services are proposed, namely the fuel shifting and the fuel discharging. The fuel shifting program consists in replacing the electric energy by fossil fuels in plug-in hybrid electric vehicles daily trips, and the fuel discharge program consists in use of their internal combustion engine to generate electricity injecting into the network. These programs are included in an energy resources management algorithm which integrates the management of other resources. The paper presents a case study considering a 37-bus distribution network with 25 distributed generators, 1908 consumers, and 2430 plug-in vehicles. Two scenarios are tested, namely a scenario with high photovoltaic generation, and a scenario without photovoltaic generation. A sensitivity analyses is performed in order to evaluate when each energy resource is required.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfilment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A gestão de energia é um dos factores chave do sucesso de uma empresa e como qualquer outro factor de produção deve ser gerido continuamente e eficazmente. A gestão correcta do consumo de energia assume-se como crucial nas empresas do sector cerâmico pois exigem grande consumo de gás natural. Também a tendência de aumento do custo do gás natural tem induzido a necessidade de minimização do consumo de combustível nas indústrias e favorecido o desenvolvimento de novas abordagens para a optimização deste recurso natural. O trabalho apresentado nesta tese teve como objectivo a optimização da energia nas estufas de secagem na Fábrica de Cerâmica de Valadares S.A. A actividade desta empresa consiste na produção de louça sanitária envolvendo um consumo elevado de energia. Realizou-se um levantamento das condições técnicas/operacionais dos equipamentos em estudo e elaborou-se uma ferramenta de simulação que foi aplicada para realizar um balanço energético detalhado e diagnóstico da situação existente. No seguimento, foi efectuada uma análise de mercado, para elaboração do estudo económico da implementação das medidas sugeridas, nomeadamente, a recuperação dos gases de combustão que saem das três estufas que secam os moldes para as estufas de louça cerâmica. Optou-se por esta medida uma vez que reduzirá significativamente, em cerca de 50%, o consumo de combustível (gás natural) nas estufas de secagem. O tempo de retorno do investimento necessário para adquirir o equipamento é de, aproximadamente, 10 meses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A definição de teores mínimos de incorporação de biocombustíveis, constitui objeto de discussão entre grupos pro-desenvolvimento e ambientalistas. Esses últimos argumentam que as consequências da utilização desta fonte energética ainda são desconhecidas. Além disso, alegam que a produção de biocombustíveis é, em parte, responsável pelo aumento no preço dos alimentos, encoraja a conversão de florestas em monoculturas e conduz à exploração de trabalhadores em países em desenvolvimento (PEDs). Para responder à dependência energética dos combustíveis de origem fóssil, e ajudar a reduzir as emissões de gases com efeito de estufa, sobretudo no sector dos transportes, o biodiesel produzido a partir de óleos alimentares usados têm sido apontado como uma “solução verde” capaz de minimizar o problema das alterações climáticas e valorizar um resíduo, e simultaneamente conferir ao setor energético um pouco mais de independência. De forma a desmistificar e clarificar um pouco estas premissas, a presente dissertação pretende fazer um estudo de avaliação do impacto da utilização do biodiesel, nomeadamente no que diz respeito às emissões gasosas. Posteriormente realizou-se, tomando como referência uma pequena frota industrial existente, uma análise comparativa dos consumos e emissões dos principais poluentes decorrentes da utilização do biodiesel em diferentes percentagens de incorporação no gasóleo, comparativamente ao gasóleo puro. O trabalho culmina com uma abordagem técnica sobre o comportamento de um veículo equipado com um motor de ignição por compressão, utilizando como biocombustível o biodiesel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A correta ventilação de locais afetos a serviços técnicos elétricos, nomeadamente postos de transformação e salas de grupos geradores, reveste-se de extrema importância como garantia da continuidade e qualidade do serviço prestado, durabilidade dos materiais e equipamentos e da segurança das instalações e utilizadores. A ventilação dos locais afetos a serviços técnicos elétricos pode ser natural ou mecânica, dependendo das suas caraterísticas e das necessidades de ar para ventilação e combustão, quando aplicável. Os técnicos responsáveis pelo projeto de instalações elétricas não detém, em regra, um conhecimento muito profundo sobre este tema, sendo os seus projetos realizados com base em especificações e metodologias gerais disponibilizadas pelos fabricantes e comercializadores dos materiais e equipamentos. O projeto de uma solução de ventilação para um local afeto a serviços técnicos eléctricos exige o conhecimento de todos os ganhos térmicos no interior do espaço, o conhecimento das soluções técnicas e tecnológicas de ventilação bem como as metodologias de dimensionamento aplicáveis a cada situação. Sendo a fase de projeto elétrico, em regra, uma atividade com prazos apertados, pode conduzir ao menosprezar de certos aspetos particulares que carecem de investigação e tempo para serem desenvolvidos, o que pode resultar em projetos e mapas de quantidades que apresentam desvios da solução ideal para o cliente, podendo resultar em investimentos mais elevados, quer na fase de execução, quer na fase de exploração das instalações. Neste sentido, pretendeu-se com o presente trabalho, tratar o tema da ventilação de locais afetos a serviços técnicos, atendendo ao enquadramento normativo e regulamentar das instalações, às soluções técnicas e tecnológicas disponíveis no mercado e às metodologias de dimensionamento, apresentadas pelos documentos normativos e regulamentares. Pretendeu-se também desenvolver uma ferramenta informática de auxilio ao dimensionamento das soluções de ventilação de locais afetos a serviços técnicas eléctricos destinados a postos de transformação e grupos geradores de modo a reduzir o tempo normalmente exigido por esta tarefa, o que se traduzirá numa maior rentabilidade do tempo de projeto, assim como a normalizar as soluções apresentadas e minimizar a probabilidade de erro do dimensionamento das soluções, reduzindo assim a probabilidade de gastos em “trabalhos a mais” provenientes de erros em projeto, poupança em materiais presentes no mapa de quantidades, maior eficácia na execução da empreitada, poupança em gastos durante a exploração e desta forma numa proximidade entre as partes interessadas com o dimensionamento da ventilação do espaço técnico elétrico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work a forest fire detection solution using small autonomous aerial vehicles is proposed. The FALCOS unmanned aerial vehicle developed for remote-monitoring purposes is described. This is a small size UAV with onboard vision processing and autonomous flight capabilities. A set of custom developed navigation sensors was developed for the vehicle. Fire detection is performed through the use of low cost digital cameras and near-infrared sensors. Test results for navigation and ignition detection in real scenario are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A presente dissertação foi realizada no âmbito do Mestrado em Engenharia Química no ramo de Otimização Energética na Indústria Química, do Instituto Superior de Engenharia do Porto. O estudo energético foi desenvolvido na empresa Petrogal, S.A, na Refinaria de Matosinhos, avaliando a possível racionalização energética do processo existente na Fábrica de Aromáticos. Os objetivos propostos basearam-se na realização de uma integração energética à unidade de pré-destilação, denominada por U-0100, que se encontra instalada na Fábrica de Aromáticos. Pretende-se, de uma forma geral, o reaproveitamento máximo da energia do processo, diminuindo o recurso a utilidades externas. Para tal recorreu-se à metodologia da análise do ponto de estrangulamento, designada por tecnologia Pinch. Numa primeira fase da otimização foi necessário conhecer todo o processo em causa e os conceitos associados à tecnologia aplicada. Após contactar com o processo procedeu-se ao levantamento energético do mesmo, referente ao ano 2013. Nesta etapa foram recolhidos todos os dados considerados relevantes para a quantificação energética das correntes e das utilidades empregues. Depois da recolha efetuou-se a integração energética estabelecendo um ∆Tmin ótimo para o processo de 5°C, após uma prévia análise da influência deste parâmetro sobre os consumos. Constatou-se que atualmente o processo de separação opera com uma taxa de recuperação energética de 16,8% da energia total, sendo a restante energia introduzida por utilidades externas. Com a análise do ponto de estrangulamento concluiu-se que a unidade de pré - destilação U-0100 se encontra integrada energeticamente, não sendo essencial proceder a qualquer modificação à mesma. No entanto sugere-se como trabalho futuro um estudo técnico e económico da implementação de um pré-aquecedor de ar, necessário ao processo de combustão que se dá na fornalha H-0101. Isto tendo em vista o reaproveitamento máximo da corrente, gases de combustão, que é desperdiçada para o meio ambiente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Proceedings of the 13th International UFZ-Deltares Conference on Sustainable Use and Management of Soil, Sediment and Water Resources - 9–12 June 2015 • Copenhagen, Denmark

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho realizou-se na empresa Continental – Indústria Têxtil do Ave, S.A (CITA) em colaboração com a empresa Cofely GDF Suez – Energia e Serviços Portugal, S.A. O principal objetivo desta dissertação foi a otimização energética da máquina de impregnar telas para pneus – a máquina ZELL, tendo em conta as principais utilidades envolvidas: eletricidade e gás natural. Deste modo foi feito um levantamento prévio das condições de operação desta máquina relativamente às telas mais representativas da produção da empresa. Tendo-se verificado que as telas em poliéster representam 65% da produção total da máquina ZELL. Para este tipo de produto, foi feita uma análise dos consumos energéticos anuais para avaliar qual das utilidades referidas corresponde à maior parcela energética. Verificou-se que o consumo de gás natural representa a maior parcela da fatura energética anual da empresa correspondendo a 47%. Além disso, da energia total consumida anualmente pela ZELL, que corresponde a 1360 tep, 32% é relativo à energia elétrica e os restantes 68% ao consumo de gás natural. Por fim, procedeu-se à otimização energética estudando as alterações possíveis no sentido de reduzir os consumos energéticos da máquina, sem prejuízo da qualidade do produto final. Para isso propôs-se a instalação de permutadores de fluxo cruzado para pré-aquecer quer o ar fresco quer o ar de combustão. A implementação desta medida tem um período de retorno à volta de três anos e pode levar a uma poupança anual entre 1.359.639 kWh e 2.370.114 kWh para o ar fresco e 393.523 kWh e 639.475 kWh para o ar de combustão.